Acta Biomaterialia Oct 2023Titanium (Ti) and Ti alloys are commonly used in dental implants, which have good biocompatibility, mechanical strength, processability, and corrosion resistance.... (Review)
Review
Titanium (Ti) and Ti alloys are commonly used in dental implants, which have good biocompatibility, mechanical strength, processability, and corrosion resistance. However, the surface inertia of Ti implants leads to delayed integration of Ti and new bone, as well as problems such as aseptic loosening and inadequate osseointegration. Magnesium (Mg) ions can promote bone regeneration, and many studies have used Mg-containing materials to modify the Ti implant surface. This systematic review summarizes the methods, effects, and clinical applications of surface modification of Ti implants with Mg-containing coatings. Database collection was completed on Janury 1, 2023, and a total of 29 relevant studies were ultimately included. Mg can be compounded with different materials and coated to the surface of Ti implants using different methods. In vitro and in vivo experiments have shown that Mg-containing coatings promote cell adhesion and osteogenic differentiation. On the one hand, the surface roughness of implants increases with the addition of Mg-containing coatings, which is thought to have an impact on the osseointegration of the implant. On the other hand, Mg ions promote cell attachment through binding interactions between the integrin family and FAK-related signaling pathways. And Mg ions could induce osseointegration by activating PI3K, Notch, ERK/c-Fos, BMP-4-related signaling pathways and TRPM7 protein channels. Overall, Mg-based coatings show great potential for the surface modification of Ti implants to promote osseointegration. STATEMENT OF SIGNIFICANCE: The inertia surface of titanium (Ti) implants leads to delayed osseointegration. Magnesium (Mg) ions, known for promoting bone regeneration, have been extensively studied to modify the surface of Ti implants. However, no consensus has been reached on the appropriate processing methods, surface roughness and effective concentration of Mg-containing coatings for osseointegration. This systematic review focus on the surface modification of Ti implants with Mg-containing compounds, highlighting the effects of Mg-containing coatings on the surface properties of Ti implants and its associated mechanisms. Besides, we also provide an outlook on future directions to promote the clinical application of Mg-modified implants.
Topics: Coated Materials, Biocompatible; Ions; Magnesium; Osseointegration; Osteogenesis; Surface Properties; Titanium
PubMed: 37517617
DOI: 10.1016/j.actbio.2023.07.048 -
Bioinorganic Chemistry and Applications 2022Magnesium alloys have great application prospects as ideal bone implant materials. However, their poor corrosion resistance limits their clinical orthopedic application.... (Review)
Review
Magnesium alloys have great application prospects as ideal bone implant materials. However, their poor corrosion resistance limits their clinical orthopedic application. Surface modification promotes the corrosion resistance of magnesium. Conversion coatings, such as calcium phosphate (Ca-P) coating, microarc oxidation (MAO) treatment, and fluoride (FLU) treatment, have been extensively investigated in in vivo studies. This systematic review and network meta-analysis compared the influence of different conversion coatings on bone repair, material properties, and systemic host response in orthopedic applications. Using the PICOS model, the inclusion criteria for biodegradable magnesium and its alloys were determined for in vivo studies. Four databases were used. The standard and weight mean differences with 95% confidence intervals were used to analyze new bone formation and degradation rate. Network structure and forest plots were created, and ranking probabilities were estimated. The risk of bias and quality of evidence were assessed using SYRCLE, CERQual, and GRADE tools. In the qualitative analysis, 43 studies were selected, and the evaluation of each outcome indicator was not entirely consistent from article to article. In the quantitative analysis, 21 articles were subjected to network meta-analysis, with 16 articles on implant degradation and 8 articles for new bone formation. Additionally, SUCRA indicated that Ca-P coating exhibited the highest corrosion resistance, followed by FLU treatment. MAO demonstrated the best capability for new bone formation, followed by Ca-P coating. Ca-P coating exhibited the highest overall performance. To conclude, coated Mg can promote better new bone formation than bare Mg and has considerable biocompatibility. Ca-P-coated Mg and MAO-coated Mg have the greatest potential to significantly promote corrosion resistance and bone regeneration, respectively. The findings of this study will provide a theoretical basis for the investigation of composite coatings and guidance for the orthopedic application of Mg bone implants.
PubMed: 35399618
DOI: 10.1155/2022/4529520 -
The Journal of Contemporary Dental... Aug 2023The present systematic review aimed to report the studies concerning the primers in improving bond strength and identifying pertinent primers for a particular dental... (Meta-Analysis)
Meta-Analysis
AIM
The present systematic review aimed to report the studies concerning the primers in improving bond strength and identifying pertinent primers for a particular dental alloy by adhering to PRISMA precepts.
MATERIALS AND METHODS
PubMed and Semantic Scholar databases were scoured for articles using 10 search terms. studies satisfying the inclusion criteria were probed which were meticulously screened and scrutinized for eligibility adhering to the 11 exclusion criteria. The quality assessment tool for studies (QUIN Tool) containing 12 criteria was employed to assess the risk of bias (RoB).
RESULTS
A total of 48 studies assessing shear bond strength (SBS) and 15 studies evaluating tensile bond strength (TBS) were included in the qualitative synthesis. Concerning SBS, 33.4% moderate and 66.6% high RoB was observed. Concerning TBS, 26.8% moderate and 73.2% high RoB was discerned. Seventeen and two studies assessing SBS and TBS, respectively, were included in meta-analyses.
CONCLUSIONS
Shear bond strength and TBS increased for the primed alloys. Cyclic disulfide primer is best-suited for noble alloys when compared with thiol/thione primers. Phosphoric acid- and phosphonic acid ester-based primers are opportune for base alloys.
CLINICAL SIGNIFICANCE
The alloy-resin interface (ARI) would fail if an inappropriate primer was selected. Therefore, the selection of an appropriate alloy adhesive primer for an alloy plays a crucial role in prosthetic success. This systematic review would help in the identification and selection of a congruous primer for a selected alloy.
Topics: Databases, Factual; Dental Alloys; Disulfides; Thiones; Dental Cements
PubMed: 38193174
DOI: 10.5005/jp-journals-10024-3514 -
International Journal of Implant... Jul 2023The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated.
METHODS
Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures.
RESULTS
Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36-141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients' reported increased satisfaction with ZIs.
CONCLUSIONS
ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use.
Topics: Humans; Dental Implantation, Endosseous; Dental Implants; Prosthesis Failure; Titanium; Treatment Outcome; Alloys
PubMed: 37405545
DOI: 10.1186/s40729-023-00479-x -
International Journal of Oral and... Jul 2016The use of titanium implants is well documented and they have high survival and success rates. However, when used as reduced-diameter implants, the risk of fracture is... (Meta-Analysis)
Meta-Analysis Review
The use of titanium implants is well documented and they have high survival and success rates. However, when used as reduced-diameter implants, the risk of fracture is increased. Narrow diameter implants (NDIs) of titanium-zirconium (Ti-Zr) alloy have recently been developed (Roxolid; Institut Straumann AG). Ti-Zr alloys (two highly biocompatible materials) demonstrate higher tensile strength than commercially pure titanium. The aim of this systematic review was to summarize the existing clinical evidence on dental NDIs made from Ti-Zr. A systematic literature search was performed using the Medline database to find relevant articles on clinical studies published in the English language up to December 2014. Nine clinical studies using Ti-Zr implants were identified. Overall, 607 patients received 922 implants. The mean marginal bone loss was 0.36±0.06mm after 1 year and 0.41±0.09mm after 2 years. The follow-up period ranged from 3 to 36 months. Mean survival and success rates were 98.4% and 97.8% at 1 year after implant placement and 97.7% and 97.3% at 2 years. Narrow diameter Ti-Zr dental implants show survival and success rates comparable to regular diameter titanium implants (>95%) in the short term. Long-term follow-up clinical data are needed to confirm the excellent clinical performance of these implants.
Topics: Dental Alloys; Dental Implants; Dental Prosthesis Design; Humans; Materials Testing; Tensile Strength; Titanium; Zirconium
PubMed: 26852292
DOI: 10.1016/j.ijom.2016.01.004 -
Clinical Oral Implants Research Sep 2023For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years.
MATERIALS AND METHODS
An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD.
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients).
CONCLUSIONS
After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.
Topics: Humans; Dental Implants; Prospective Studies; Retrospective Studies; Titanium; Bone Diseases, Metabolic
PubMed: 37750521
DOI: 10.1111/clr.14133 -
Journal of Dentistry Apr 2017The aim of this systematic review was to investigate the survival and complication rates of inlay-retainer fixed dental prostheses (IRFDPs). (Review)
Review
OBJECTIVES
The aim of this systematic review was to investigate the survival and complication rates of inlay-retainer fixed dental prostheses (IRFDPs).
DATA/SOURCES
A systematic search was conducted in the PubMed, EMBASE, and Cochrane Library databases in English and time filters (articles published from 1960) were used.
STUDY SELECTION
Randomized controlled trails (RCTs), controlled clinical trials (CCTs) and prospective cohort studies on IRFDPs with a mean follow-up period of at least 2 years were included. Among 501 screened articles, one RCT and ten prospective cohort studies were included in this study. Of the included studies, information on failure and complications was independently extracted by two reviewers in duplicate. The failure and complication rates of IRFDPs were pooled with a random effect model and Poisson regression was applied to further investigate the influence of framework materials. The estimated 3- and 5-year survival rates of IRFDPs were 92.6% (95% CI: 85.8-97.6%) and 87.9% (95% CI: 77.4-96.1%), respectively. Debonding, fracture, dentine hypersensitivity and secondary caries were primary complications. The estimated 5-year rates of debonding, veneer fracture and secondary caries were 5.3%, 15.2% and 2.7%, respectively. Additionally, fiber-reinforced composite IRFDPs exhibited a lower incidence of debonding and caries with a higher rate of veneer fracture compared with metal-based and all-ceramic IRFDPs (p<0.05).
CONCLUSIONS
Compared with conventional fixed dental prostheses (FDPs) and implant-supported single crowns (ISCs), IRFDPs exhibited an acceptable 3-year survival rate but higher complication rates of debonding and veneer fracture.
CLINICAL SIGNIFICANCE
IRFDPs can be recommended as viable short- or middle-term minimally invasive alternatives to short-span conventional FDPs and ISCs, while the clinical outcome of IRFDPs as long-term definitive restorations still calls for further research. The indications of IRFDPs should be strictly controlled and monitored.
Topics: Ceramics; Controlled Clinical Trials as Topic; Crowns; Databases, Factual; Dental Abutments; Dental Alloys; Dental Materials; Dental Prosthesis Design; Dental Prosthesis Retention; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Dental Veneers; Denture, Partial, Fixed; Denture, Partial, Fixed, Resin-Bonded; Humans; Inlays; Randomized Controlled Trials as Topic; Treatment Outcome
PubMed: 28212978
DOI: 10.1016/j.jdent.2017.02.006 -
The Journal of Prosthetic Dentistry Mar 2023Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM)... (Review)
Review
STATEMENT OF PROBLEM
Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have shown promising clinical outcomes; however, the influence of manufacturing techniques on the properties of RPD components is unclear.
PURPOSE
The purpose of this systematic review was to determine the accuracy and mechanical properties of RPD components fabricated with conventional and digital methods.
MATERIAL AND METHODS
This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) and was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42022353993). An electronic search was conducted on PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library in August 2022. Only in vitro studies comparing the digital with the lost-wax casting technique were included. The quality of the studies was assessed by using the methodological index for nonrandomized studies (MINORS) scale.
RESULTS
Of the 17 selected studies, 5 evaluated the accuracy of RPD components as well as the mechanical properties, 5 studies evaluated only the component accuracy, and another 7 evaluated only the mechanical properties. The accuracy was similar regardless of the technique, with discrepancies within clinically acceptable values (50 to 426.3 μm). The surface roughness was higher for 3D-printed clasps and lower for milled clasps (P<.05). The metal alloy significantly influenced the porosity, with the highest number of pores obtained by casting for Ti clasps and by rapid prototyping for Co-Cr clasps.
CONCLUSIONS
In vitro studies showed that the digital technique provided similar accuracy to that of the conventional technique within a clinically acceptable range. The manufacturing technique influenced the mechanical properties of RPD components.
PubMed: 36870892
DOI: 10.1016/j.prosdent.2023.01.032 -
Materials (Basel, Switzerland) Sep 2021(1) Background: Hypersensitivity reactions to metals may arise in predisposed patients chronically exposed to metallic materials, including dental implants made of... (Review)
Review
(1) Background: Hypersensitivity reactions to metals may arise in predisposed patients chronically exposed to metallic materials, including dental implants made of titanium alloys. The purpose of this article was to systematically review titanium allergy manifestations in patients treated with dental implants and report a clinical case; (2) Methods: A systematic electronic search was performed for articles published in the English language until July 2021. The following eligibility criteria were adopted: (1) Population: individuals undergoing titanium and/or titanium alloy implant-supported rehabilitations; (2) Exposure: peri-implant soft tissue reactions attributable to implant insertion; (3) Outcome: evidence of titanium allergy, diagnostic methods, and forms of resolution; (3) Results: The included studies, in summary, presented evidence that titanium should not be considered an inert material, being able to trigger allergic reactions, and may be responsible for implant failure. A 55-year-old male patient received 3 implants in the posterior region of the left mandible and presented an epulis-like lesion developed from the peri-implant mucosa. The immunohistochemical analysis of the biopsy specimen confirmed the initial diagnosis of allergic reaction to titanium; (4) Conclusions: Although the evidence is weak, and titanium allergy has a low incidence, hypersensitivity reactions should not be underestimated. A rapid and conclusive diagnosis is mandatory to prevent further complications.
PubMed: 34576463
DOI: 10.3390/ma14185239 -
Clinical Oral Implants Research Sep 2023In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year?
MATERIALS AND METHODS
This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487).
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material.
CONCLUSIONS
Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Topics: Humans; Titanium; Dental Implants; Alloys; Aluminum Oxide
PubMed: 37750527
DOI: 10.1111/clr.14159