The Cochrane Database of Systematic... Apr 2018Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life.
OBJECTIVES
To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people.
SEARCH METHODS
Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the same material and different techniques, or different materials and the same technique. In tooth- and tissue-supported RPD, we included trials comparing the same material and different dual-impression techniques, and different materials with different dual-impression techniques.
DATA COLLECTION AND ANALYSIS
Two review authors independently, and in duplicate, screened studies for eligibility, extracted data, and assessed the risk of bias for each included trial. We expressed results as risk ratios (RR) for dichotomous outcomes, and as mean differences (MD) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CI), using the random-effects model. We constructed 'Summary of findings' tables for the main comparisons and outcomes (participant-reported oral health-related quality of life, quality of the denture, and denture border adjustments).
MAIN RESULTS
We included nine studies in this review. Eight studies involved 485 participants with CD. We assessed six of the studies to be at high risk of bias, and two to be at low risk of bias. We judged one study on RPD with 72 randomised participants to be at high risk of bias.Overall, the quality of the evidence for each comparison and outcome was either low or very low, therefore, results should be interpreted with caution, as future research is likely to change the findings.Complete denturesTwo studies compared the same material and different techniques (one study contributed data to a secondary outcome only); two studies compared the same technique and different materials; and four studies compared different materials and techniques.One study (10 participants) evaluated two stage-two step, Biofunctional Prosthetic system (BPS) using additional silicone elastomer compared to conventional methods, and found no evidence of a clear difference for oral health-related quality of life, or quality of the dentures (denture satisfaction). The study reported that BPS required fewer adjustments. We assessed the quality of the evidence as very low.One study (27 participants) compared selective pressure final-impression technique using wax versus polysulfide elastomeric (rubber) material. The study did not measure quality of life or dentures, and found no evidence of a clear difference between interventions in the need for adjustments (RR 0.81, 95% CI 0.38 to 1.70). We assessed the quality of the evidence as very low.One study compared two stage-two step final impression with alginate versus silicone elastomer. Oral health-related quality of life measured by the OHIP-EDENT seemed to be better with silicone (MD 7.20, 95% CI 2.71 to 11.69; 144 participants). The study found no clear differences in participant-reported quality of the denture (comfort) after a two-week 'confirmation' period, but reported that silicone was better for stability and chewing efficiency. We assessed the quality of the evidence as low.Three studies compared single-stage impressions with alginate versus two stage-two step with elastomer (silicone, polysulfide, or polyether) impressions. There was no evidence of a clear difference in the OHIP-EDENT at one month (MD 0.05, 95% CI -2.37 to 2.47; two studies, 98 participants). There was no evidence of a clear difference in participant-rated general satisfaction with dentures at six months (MD 0.00, 95% CI -8.23 to 8.23; one study, 105 participants). We assessed the quality of the evidence as very low.One study compared single-stage alginate versus two stage-two step using zinc-oxide eugenol, and found no evidence of a clear difference in OHIP-EDENT (MD 0.50, 95% CI -2.67 to 3.67; 39 participants), or general satisfaction (RR 3.15, 95% CI 0.14 to 72.88; 39 participants) at six months. We assessed the quality of the evidence as very low.Removable partial denturesOne study randomised 72 participants and compared altered-cast technique versus one-piece cast technique. The study did not measure quality of life, but reported that most participants were satisfied with the dentures and there was no evidence of any clear difference between groups for general satisfaction at one-year follow-up (low-quality evidence). There was no evidence of a clear difference in number of intaglio adjustments at one year (RR 1.43, 95% CI 0.61 to 3.34) (very low-quality evidence).
AUTHORS' CONCLUSIONS
We conclude that there is no clear evidence that one technique or material has a substantial advantage over another for making complete dentures and removable partial dentures. Available evidence for the relative benefits of different denture fabrication techniques and final-impression materials is limited and is of low or very low quality. More high-quality RCTs are required.
Topics: Dental Impression Materials; Dental Impression Technique; Denture Design; Denture Retention; Denture, Partial, Removable; Dentures; Humans; Mouth, Edentulous; Quality of Life; Randomized Controlled Trials as Topic
PubMed: 29617037
DOI: 10.1002/14651858.CD012256.pub2 -
Journal of Prosthodontics : Official... Jan 2018To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. (Review)
Review
PURPOSE
To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques.
MATERIALS AND METHODS
Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search.
RESULTS
Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions.
CONCLUSIONS
Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions.
Topics: Computer-Aided Design; Dental Impression Technique
PubMed: 27483210
DOI: 10.1111/jopr.12527 -
BMC Oral Health Sep 2017The continuous development in dental processing ensures new opportunities in the field of fixed prosthodontics in a complete virtual environment without any physical... (Review)
Review
BACKGROUND
The continuous development in dental processing ensures new opportunities in the field of fixed prosthodontics in a complete virtual environment without any physical model situations. The aim was to compare fully digitalized workflows to conventional and/or mixed analog-digital workflows for the treatment with tooth-borne or implant-supported fixed reconstructions.
METHODS
A PICO strategy was executed using an electronic (MEDLINE, EMBASE, Google Scholar) plus manual search up to 2016-09-16 focusing on RCTs investigating complete digital workflows in fixed prosthodontics with regard to economics or esthetics or patient-centered outcomes with or without follow-up or survival/success rate analysis as well as complication assessment of at least 1 year under function. The search strategy was assembled from MeSH-Terms and unspecific free-text words: {(("Dental Prosthesis" [MeSH]) OR ("Crowns" [MeSH]) OR ("Dental Prosthesis, Implant-Supported" [MeSH])) OR ((crown) OR (fixed dental prosthesis) OR (fixed reconstruction) OR (dental bridge) OR (implant crown) OR (implant prosthesis) OR (implant restoration) OR (implant reconstruction))} AND {("Computer-Aided Design" [MeSH]) OR ((digital workflow) OR (digital technology) OR (computerized dentistry) OR (intraoral scan) OR (digital impression) OR (scanbody) OR (virtual design) OR (digital design) OR (cad/cam) OR (rapid prototyping) OR (monolithic) OR (full-contour))} AND {("Dental Technology" [MeSH) OR ((conventional workflow) OR (lost-wax-technique) OR (porcelain-fused-to-metal) OR (PFM) OR (implant impression) OR (hand-layering) OR (veneering) OR (framework))} AND {(("Study, Feasibility" [MeSH]) OR ("Survival" [MeSH]) OR ("Success" [MeSH]) OR ("Economics" [MeSH]) OR ("Costs, Cost Analysis" [MeSH]) OR ("Esthetics, Dental" [MeSH]) OR ("Patient Satisfaction" [MeSH])) OR ((feasibility) OR (efficiency) OR (patient-centered outcome))}. Assessment of risk of bias in selected studies was done at a 'trial level' including random sequence generation, allocation concealment, blinding, completeness of outcome data, selective reporting, and other bias using the Cochrane Collaboration tool. A judgment of risk of bias was assigned if one or more key domains had a high or unclear risk of bias. An official registration of the systematic review was not performed.
RESULTS
The systematic search identified 67 titles, 32 abstracts thereof were screened, and subsequently, three full-texts included for data extraction. Analysed RCTs were heterogeneous without follow-up. One study demonstrated that fully digitally produced dental crowns revealed the feasibility of the process itself; however, the marginal precision was lower for lithium disilicate (LS2) restorations (113.8 μm) compared to conventional metal-ceramic (92.4 μm) and zirconium dioxide (ZrO2) crowns (68.5 μm) (p < 0.05). Another study showed that leucite-reinforced glass ceramic crowns were esthetically favoured by the patients (8/2 crowns) and clinicians (7/3 crowns) (p < 0.05). The third study investigated implant crowns. The complete digital workflow was more than twofold faster (75.3 min) in comparison to the mixed analog-digital workflow (156.6 min) (p < 0.05). No RCTs could be found investigating multi-unit fixed dental prostheses (FDP).
CONCLUSIONS
The number of RCTs testing complete digital workflows in fixed prosthodontics is low. Scientifically proven recommendations for clinical routine cannot be given at this time. Research with high-quality trials seems to be slower than the industrial progress of available digital applications. Future research with well-designed RCTs including follow-up observation is compellingly necessary in the field of complete digital processing.
Topics: Computer-Aided Design; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Humans; Workflow
PubMed: 28927393
DOI: 10.1186/s12903-017-0415-0 -
Clinical Oral Investigations Dec 2021The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures... (Review)
Review
OBJECTIVES
The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes.
MATERIALS AND METHODS
Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available.
RESULTS
Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS.
CONCLUSIONS
Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes.
CLINICAL RELEVANCE
Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Technique; Humans; Patient Comfort; Prospective Studies; Prosthodontics
PubMed: 34568955
DOI: 10.1007/s00784-021-04157-3 -
Gels (Basel, Switzerland) Mar 2022Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to... (Review)
Review
Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to delayed dentin sealing (DDS), a technique in which hybridization is performed following the provisional phase and just before the indirect restoration luting procedure. This study aimed to compare the bond strength of restorations to dentin of the IDS and the DDS techniques throughout a systematic review and meta-analysis. The following PICOS framework was used: population, indirect restorations; intervention, IDS; control, DDS; outcomes, bond strength; and study design, in vitro studies. PubMed (MedLine), The Cochrane Library, ISI Web of Science, Scielo, Scopus, and Embase were screened up to January 2022 by two reviewers (L.H. and R.B.). In vitro papers studying the bond strength to human dentin of the IDS technique compared to the DDS technique were considered. Meta-analyses were carried out by using a software program (Review Manager v5.4.1; The Cochrane Collaboration). Comparisons were made by considering the adhesive used for bonding (two-step etch-and-rinse, three step etch-and-rinse, one-step self-etch, two-step self-etch, and universal adhesives). A total of 3717 papers were retrieved in all databases. After full-text assessment, 22 potentially eligible studies were examined for qualitative analysis, leaving a total of 21 articles for the meta-analysis. For the immediate bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p < 0.001). Taking into account the subgroup analysis, it seems that the use of the IDS technique with a two-step etch-and-rinse or a one-step self-etch adhesive system does not represent any advantage over the DDS technique (p = 0.07, p = 0.15). On the other hand, for the aged bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p = 0.001). The subgroups analysis shows that this improvement is observed only when a three-step etch-and-rinse adhesive system (p < 0.001) or when a combination of an adhesive system plus a layer of flowable resin (p = 0.01) is used. The in vitro evidence suggests that the use of the IDS technique improves the bond strength of dentin to resin-based restorations regardless of the adhesive strategy used. The use of a three-step etch-and-rinse adhesive system or the combination of an adhesive system plus a layer of flowable resin seems to considerably enhance the bond strength in the long term.
PubMed: 35323288
DOI: 10.3390/gels8030175 -
Clinical Oral Investigations Sep 2022The purpose of this systematic review was to compare the accuracy of digital and conventional full-arch impressions in vivo. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The purpose of this systematic review was to compare the accuracy of digital and conventional full-arch impressions in vivo.
MATERIALS AND METHODS
This systematic review was conducted according to the PRISMA and registered at the PROSPERO (CRD42021232736). Electronic and hand searches were performed to identify in vivo studies comparing the linear or 3D accuracy of digital and conventional impressions. The risk of bias (ROB) of included studies was assessed by QUADAS-2, and the overall quality of evidence was assessed by GRADE.
RESULTS
Twenty-two studies met the inclusion criteria, and 13 studies were included in the meta-analysis. There was no significant difference between digital and conventional impressions in the linear measurements of tooth width, anterior Bolton ratio, overall Bolton ratio, intercanine distance (ICD), and intermolar distance (IMD). The repeated measurement mean errors (RMEs) were less than 0.1 mm, the intra-examiner intraclass correlation coefficient (ICC) values were more than 0.9, and the inter-examiner ICC values were more than 0.87 for both impression techniques. The 3D deviation between digital and alginate impressions was 0.09 mm. The 3D precision of both impression techniques was less than 0.1 mm.
CONCLUSIONS
The trueness of digital and alginate full-arch impressions was similar, and both impression techniques showed high precision. More research was needed to compare digital impressions and other conventional impression materials.
CLINICAL RELEVANCE
For patients with completely natural dentition, the digital impressions obtained directly from intraoral scanning can be considered a viable alternative to alginate impressions.
Topics: Alginates; Computer-Aided Design; Dental Arch; Dental Impression Materials; Dental Impression Technique; Humans; Imaging, Three-Dimensional; Models, Dental
PubMed: 35786783
DOI: 10.1007/s00784-022-04607-6 -
Journal of Prosthodontics : Official... Oct 2020To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant... (Meta-Analysis)
Meta-Analysis
PURPOSE
To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant impressions for partially and completely edentulous patients.
MATERIALS AND METHODS
Electronic and manual searches were conducted to identify in vitro and clinical studies, reporting on the 3D accuracy between digital and conventional implant impressions. Secondary outcomes were the effect of implant angulation, type of conventional impression technique, and type of intraoral scanner on the accuracy of implant impressions.
RESULTS
The inclusion criteria were met by 9 in vitro studies and 1 clinical study reporting on completely edentulous impressions, while 6 in vitro and 2 clinical studies reported on partially edentulous impressions. Quantitative meta-analysis was performed for 5 completely edentulous and 6 partially edentulous studies. The studies exhibited high values for heterogeneity. A random effects model was conducted to estimate the effect size. Based on 5 in vitro studies on completely edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 8.20 µm (95% CI: -53.56, 37.15) and the digital impressions had nominally less deviation (p = 0.72). Based on 1 clinical and 5 in vitro studies on partially edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 52.31 µm (95% CI: 6.30, 98.33) and the conventional impressions had nominally less deviation (p = 0.03). Five in vitro and 2 clinical studies were not included in the quantitative analysis due to heterogeneity in the methodology. Implant angulation affected the accuracy in favor of the partially edentulous conventional impressions whereas the effect of different scanners was not statistically significant on the completely edentulous impressions (p = 0.82).
CONCLUSIONS
Digital scans appear to have comparable 3D accuracy with conventional implant impressions based mainly on in vitro studies. However, clinical trials are recommended to investigate the clinical accuracy of digital scans and digitally fabricated interim or prototype prostheses, before digital implant scans can be recommended for routine clinical use.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Materials; Dental Impression Technique; Humans; Models, Dental; Mouth, Edentulous
PubMed: 32613641
DOI: 10.1111/jopr.13211 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case...
PURPOSE
This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
STUDY SELECTION
We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records.
RESULTS
A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs.
CONCLUSIONS
Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital RPDs.
Topics: Computer-Aided Design; Denture, Partial, Removable; Humans; Mouth, Edentulous; Randomized Controlled Trials as Topic
PubMed: 33504721
DOI: 10.2186/jpr.JPR_D_20_00116 -
Implant Dentistry Dec 2017The objective was to provide a comprehensive systematic review about the accuracy of digital implant impression in comparison with the conventional implant impression... (Review)
Review
PURPOSE
The objective was to provide a comprehensive systematic review about the accuracy of digital implant impression in comparison with the conventional implant impression approach.
MATERIALS AND METHODS
PubMed, Google Scholar and Cochrane databases were used to classify the related articles with no year limitation in 3 stages by 2 reviewers. Finally, 10 articles were included based on inclusion and exclusion criteria.
RESULTS
Five articles supported the use of intraoral scanners in implant dentistry. The two in vivo pilot studies showed that digital scanning is not reliable and could not be used in clinical routine.
CONCLUSION
Because each study included in this review has its unique methodology and design, it is therefore early to conclude whether to use digital scanners for clinical practice or not. More well-conducted in vitro and clinical trials studies are recommended to investigate the accuracy of intraoral scanners.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Materials; Dental Impression Technique; Humans; Models, Dental
PubMed: 29095786
DOI: 10.1097/ID.0000000000000683 -
Journal of Clinical and Diagnostic... Oct 2015Utility of various dental materials ranging from diagnosis to rehabilitation for the management of oral diseases are not devoid of posing a potential risk of inducing... (Review)
Review
INTRODUCTION
Utility of various dental materials ranging from diagnosis to rehabilitation for the management of oral diseases are not devoid of posing a potential risk of inducing allergic reactions to the patient, technician and dentist. This review aims to develop a systematic approach for the selection and monitoring of dental materials available in the market thereby giving an insight to predict their risk of inducing allergic reactions.
MATERIALS AND METHODS
Our data included 71 relevant articles which included 60 case reports, 8 prospective studies and 3 retrospective studies. The source of these articles was Pub Med search done with the following terms: allergies to impression materials, sodium hypochlorite, Ledermix paste, zinc oxide eugenol, formaldehyde, Latex gloves, Methyl methacrylate, fissure sealant, composites, mercury, Nickel-chromium, Titanium, polishing paste and local anaesthesia. All the relevant articles and their references were analysed. The clinical manifestations of allergy to different dental materials based on different case reports were reviewed.
RESULTS
After reviewing the literature, we found that the dental material reported to cause most adverse reactions in patients is amalgam and the incidence of oral lichenoid reactions adjacent to amalgam restorations occur more often than other dental materials.
CONCLUSION
The most common allergic reactions in dental staff are allergies to latex, acrylates and formaldehyde. While polymethylmethacrylates and latex trigger delayed hypersensitivity reactions, sodium metabisulphite and nickel cause immediate reactions. Over the last few years, due to the rise in number of patients with allergies from different materials, the practicing dentists should have knowledge about documented allergies to known materials and thus avoid such allergic manifestations in the dental clinic.
PubMed: 26557634
DOI: 10.7860/JCDR/2015/15640.6589