BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9 -
European Urology Open Science Jun 2023The incidence of urolithiasis is increasing year by year. Ureteral stents are a popular treatment option for this condition. Efforts to improve the material and... (Review)
Review
CONTEXT
The incidence of urolithiasis is increasing year by year. Ureteral stents are a popular treatment option for this condition. Efforts to improve the material and structure of stents to increase comfort and reduce complications have led to the introduction of magnetic stents.
OBJECTIVE
To evaluate differences in removal efficiency and safety for magnetic and conventional stents.
EVIDENCE ACQUISITION
This study was conducted and reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Data were extracted according to the PRISMA principles. We collected and combined data from randomized controlled trials on magnetic versus conventional stents to evaluate the efficiency of their removal and the associated effects. Data synthesis was performed using RevMan 5.4.1 and heterogeneity was evaluated using I tests. A sensitivity analysis was also performed. Key metrics included the stent removal time, Visual Analog Scale (VAS) pain scores, and Ureteral Stent Symptom Questionnaire (USSQ) scores for various domains.
EVIDENCE SYNTHESIS
Seven studies were included in the review. We found that magnetic stents had a shorter removal time (mean difference [MD] -8.28 min, 95% confidence interval [CI] -15.6 to -0.95; = 0.03) and their removal was associated with less pain (MD -3.01 points, 95% CI -3.83 to -2.19; < 0.01) in comparison to conventional stents. USSQ scores for urinary symptoms and sexual matters were higher for magnetic than for conventional stents. There were no other differences between the stent types.
CONCLUSIONS
Magnetic ureteral stents have the advantages of a shorter removal time, less pain during removal, and low cost in comparison to conventional stents.
PATIENT SUMMARY
For patients undergoing treatment of urinary stones, a thin tube called a stent is often temporarily inserted in the tube between the kidney and the bladder to allow stones to pass. Magnetic stents can be removed without any need for a second surgical procedure. Our review of studies comparing two types of stents suggests that magnetic stents are superior to conventional stents in terms of efficiency and comfort during removal.
PubMed: 37182117
DOI: 10.1016/j.euros.2023.04.004 -
Neuromodulation : Journal of the... Jun 2022Theta burst stimulation (TBS) is often used in clinical practice and research protocols for adults with neuropsychiatric disorders. There are substantial knowledge gaps... (Review)
Review
OBJECTIVES
Theta burst stimulation (TBS) is often used in clinical practice and research protocols for adults with neuropsychiatric disorders. There are substantial knowledge gaps related to the application of TBS in children and adolescents. This systematic review examined the safety and tolerability of TBS in children and adolescents.
MATERIALS AND METHODS
A systematic review of human TBS studies in children and adolescents was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The following inclusion criteria were applied: 1) articles in English language only; 2) studies that included child and adolescent participants (up to 21 years of age); 3) studies that administered intermittent TBS or continuous TBS or both to participants; 4) studies that had an outcome measure; and 5) availability of full text material. The primary outcome measures were tolerability and safety. When feasible, the clinical effects were reviewed.
RESULTS
Twenty relevant articles met the criteria for inclusion. The reported adverse events were mild and similar to what is noted in adult studies. The most common symptom was headache. One case report described a seizure induced by TBS. Collectively, the studies were heterogeneous but the methodologic quality of randomized trials was high.
CONCLUSIONS
TBS interventions in children may have similar safety, tolerability, and feasibility as compared to adults. However, long-term, follow-up studies of TBS are lacking. Future dose-ranging studies with systematic assessment of adverse events will be important in the translation of findings with TBS from adults to youth.
Topics: Adolescent; Adult; Child; Follow-Up Studies; Headache; Humans; Transcranial Magnetic Stimulation
PubMed: 35670061
DOI: 10.1111/ner.13455 -
Journal of Orthopaedic Surgery and... Jun 2021Extracorporeal shock wave therapy (ESWT) has been used for various pathologies associated with bone marrow oedema (BME). However, it is still not clear whether ESWT may... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Extracorporeal shock wave therapy (ESWT) has been used for various pathologies associated with bone marrow oedema (BME). However, it is still not clear whether ESWT may be favourable in the treatment of BME. Therefore, the aim of this systematic review was to assess the efficacy of ESWT for the treatment of BME.
METHODS
MEDLINE was searched for relevant literature with no time constraints. Both randomized and non-randomized trials were included. Case reports and conference abstracts were excluded. Titles and abstracts were screened and full-text articles of included studies were retrieved. Data on the effect of ESWT on pain, function, and the BME area on magnet resonance imaging were extracted.
RESULTS
Pain, function, and magnet resonance imaging results all improved across the studies - regardless of whether it was a randomized or non-randomized study. This effect was consistent across multiple pathologies such as osteonecrosis of the femoral head, BME associated with knee osteoarthritis, Kienböck's disease, and osteitis pubis. The meta-analysis showed that pain (after 1 month: weighted mean difference (WMD) = - 2.23, 95% CI - 2.58 to - 1.88, P < 0.0001; after 3-6 month: WMD = - 1.72, 95% CI - 2.52 to - 0.92, P < 0.00001) and function (after 1 month: WMD = - 1.59, 95% CI - 2.04 to - 1.14, P < 0.0001; after 3-6 month: WMD = - 2.06, 95% CI - 3.16 to - 0.96, P = 0.0002; after ≥ 12 month: WMD = - 1.20, 95% CI - 1.83 to - 0.56, P = 0.0002) was reduced in terms of ESWT treatment compared to a control group.
CONCLUSIONS
Based on the available evidence, ESWT may be an adequate option for conservative therapy in pathologies involving BME.
TRIAL REGISTRATION
PROSPERO, CRD42021201719 . Registered 23 December 2020.
Topics: Bone Diseases; Bone Marrow; Conservative Treatment; Edema; Extracorporeal Shockwave Therapy; Female; Femur Head Necrosis; Humans; Male; Osteoarthritis, Knee; Treatment Outcome
PubMed: 34107978
DOI: 10.1186/s13018-021-02484-5 -
Frontiers in Neuroscience 2021Magnetic control systems of micro-robots have recently blossomed as one of the most thrilling areas in the field of medical treatment. For the sake of learning how to...
Magnetic control systems of micro-robots have recently blossomed as one of the most thrilling areas in the field of medical treatment. For the sake of learning how to apply relevant technologies in medical services, we systematically review pioneering works published in the past and divide magnetic control systems into three categories: stationary electromagnet control systems, permanent magnet control systems and mobile electromagnet control systems. Based on this, we ulteriorly analyze and illustrate their respective strengths and weaknesses. Furthermore, aiming at surmounting the instability of magnetic control system, we utilize SolidWorks2020 software to partially modify the SAMM system to make its final overall thickness attain 111 mm, which is capable to control and observe the motion of the micro-robot under the microscope system in an even better fashion. Ultimately, we emphasize the challenges and open problems that urgently need to be settled, and summarize the direction of development in this field, which plays a momentous role in the wide and safe application of magnetic control systems of micro-robots in clinic.
PubMed: 34512256
DOI: 10.3389/fnins.2021.736730 -
The British Journal of Surgery Oct 2016The standard for sentinel lymph node biopsy (SLNB), the dual technique (radiolabelled tracer and blue dye), has several drawbacks. A novel magnetic technique without... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The standard for sentinel lymph node biopsy (SLNB), the dual technique (radiolabelled tracer and blue dye), has several drawbacks. A novel magnetic technique without these drawbacks has been evaluated in a number of clinical trials. It uses a magnetic tracer and a handheld magnetometer to identify and excise sentinel lymph nodes. A systematic review and meta-analysis was performed to assess the performance and utility of the magnetic in comparison to the standard technique.
METHODS
MEDLINE, PubMed, Embase and the Cochrane online literature databases were used to identify all original articles evaluating the magnetic technique for SLNB published up to April 2016. Studies were included if they were prospectively conducted clinical trials comparing the magnetic with the standard technique for SLNB in patients with breast cancer.
RESULTS
Seven studies were included. The magnetic technique was non-inferior to the standard technique (z = 3·87, P < 0·001), at a 2 per cent non-inferiority margin. The mean identification rates for the standard and magnetic techniques were 96·8 (range 94·2-99·0) and 97·1 (94·4-98·0) per cent respectively (risk difference (RD) 0·00, 95 per cent c.i. -0·01 to 0·01; P = 0·690). The total lymph node retrieval was significantly higher with the magnetic compared with the standard technique: 2113 (1·9 per patient) versus 2000 (1·8 per patient) (RD 0·05, 0·03 to 0·06; P = 0·003). False-negative rates were 10·9 (range 6-22) per cent for the standard technique and 8·4 (2-22) per cent for the magnetic technique (RD 0·03, 0·00 to 0·06; P = 0·551). The mean discordance rate was 3·9 (range 1·7-6·9) per cent.
CONCLUSION
The magnetic technique for SLNB is non-inferior to the standard technique, with a high identification rate but with a significantly higher lymph node retrieval rate.
Topics: Breast Neoplasms; Clinical Trials as Topic; Feasibility Studies; Female; Humans; Lymphatic Metastasis; Magnetometry; Magnets; Sensitivity and Specificity; Sentinel Lymph Node; Sentinel Lymph Node Biopsy
PubMed: 27611729
DOI: 10.1002/bjs.10283 -
The Journal of Prosthetic Dentistry Jun 2022A systematic review of the effect of different overdenture attachments with different loading protocols on peri-implant health is lacking. (Meta-Analysis)
Meta-Analysis Review
Effect of 2-implant mandibular overdenture with different attachments and loading protocols on peri-implant health and prosthetic complications: A systematic review and network meta-analysis.
STATEMENT OF PROBLEM
A systematic review of the effect of different overdenture attachments with different loading protocols on peri-implant health is lacking.
PURPOSE
The purpose of this systematic review and network meta-analysis was to evaluate the effect of different overdenture attachments with delayed or immediately loaded 2-implant-retained mandibular overdentures on peri-implant tissue health.
MATERIAL AND METHODS
A comprehensive search of the PubMed, EMBASE, and Cochrane library was conducted to identify eligible randomized controlled trials (RCTs). The outcomes were marginal bone loss, probing depth, plaque index, bleeding on probing, implant survival rate, and prosthetic complications. The Bayesian network meta-analysis accompanied by a random effect model and 95% credible intervals was calculated.
RESULTS
Sixteen RCT (n=599 participants receiving 1198 dental implants) were included. Five common overdenture attachment systems with delayed or immediate loading were compared. The difference in marginal bone loss and probing depth was not statistically significant when comparing different overdenture attachments with different loading protocols. The rank probability test showed that bar+ immediate loading ranked highest (63.8%) in terms of marginal bone loss, whereas ball+ delayed loading (73.3%) ranked highest in terms of probing depth. The implant survival rate was 100% for the LOCATOR+ delayed loading, resilient telescopic+ delayed loading, and magnet+ immediate loading; however, bar+ delayed loading, ball+ delayed loading, magnet+ delayed loading, LOCATOR+ immediate loading, ball+ immediate loading, and bar+ immediate loading had survival rates of 99.1%, 98.8%, 96.0%, 94.7%, 93.1%, and 91.2%, respectively.
CONCLUSIONS
All types of overdenture attachment with immediate loading or delayed loading had a similar effect on peri-implant health. Bar+ immediate loading was associated with the least marginal bone loss, whereas ball+ delayed loading showed the least probing depth.
Topics: Dental Implants; Dental Prosthesis, Implant-Supported; Denture, Overlay; Humans; Immediate Dental Implant Loading; Jaw, Edentulous; Mandible; Network Meta-Analysis; Treatment Outcome
PubMed: 33546861
DOI: 10.1016/j.prosdent.2020.12.016 -
The Oncologist Sep 2017Circulating DNA can be detected and quantified in the blood of cancer patients and used for detection of tumor-specific genetic alterations. The clinical utility has... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Circulating DNA can be detected and quantified in the blood of cancer patients and used for detection of tumor-specific genetic alterations. The clinical utility has been intensively investigated for the past 10 years. The majority of reports focus on analyzing the clinical potential of tumor-specific mutations, whereas the use of total cell-free DNA (cfDNA) quantification is somehow controversial and sparsely described in the literature, but holds important clinical information in itself. The purpose of the present report was to present a systematic review and meta-analysis of the prognostic value of total cfDNA in patients with metastatic colorectal cancer (mCRC) treated with chemotherapy. In addition, we report on the overall performance of cfDNA as source for mutation detection.
MATERIALS AND METHODS
A systematic literature search of PubMed and Embase was performed by two independent investigators. Eligibility criteria were (a) total cfDNA analysis, (b) mCRC, and (c) prognostic value during palliative treatment. The preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines were followed, and meta-analysis applied on both aggregate data extraction and individual patients' data.
RESULTS
Ten eligible cohorts were identified, including a total of 1,076 patients. Seven studies used quantitative polymerase chain reaction methods, two BEAMing [beads, emulsification, amplification, and magnetics] technology, and one study digital droplet polymerase chain reaction. The baseline levels of cfDNA was similar in the presented studies, and all studies reported a clear prognostic value in favor of patients with lowest levels of baseline cfDNA. A meta-analysis revealed a combined estimate of favorable overall survival hazard ratio (HR) in patients with levels below the median cfDNA (HR = 2.39, 95% confidence interval 2.03-2.82, < .0001).
CONCLUSION
The total cfDNA levels are high in patients with mCRC and bear strong prognostic information, which should be tested prospectively by using a predefined cut-off value based on normal values in healthy cohorts. Finally, the potential use of cfDNA for detection of tumor-specific mutations was emphasized in a large individual patients' data meta-analysis.
IMPLICATIONS FOR PRACTICE
Reliable prognostic markers could help to guide patients and treating physicians regarding the relevance and choice of systemic therapy. Small fragments of circulating cell-free DNA (cfDNA) can be measured in a simple blood sample. This report presents the first meta-analysis of the prognostic value of total cfDNA measurement in patients with metastatic colorectal cancer. Data from 1,076 patients confirmed that patients with the lowest pre-treatment levels of cfDNA had a significantly higher chance of longer survival than those with higher levels. Cell-free DNA analysis can also be used for detection of tumor-specific mutations, and hold potential as a valuable tool in colorectal cancer treatment.
Topics: Antineoplastic Agents; Biomarkers, Tumor; Circulating Tumor DNA; Colorectal Neoplasms; Disease-Free Survival; Humans; Prognosis; Real-Time Polymerase Chain Reaction
PubMed: 28778958
DOI: 10.1634/theoncologist.2016-0178 -
JBI Database of Systematic Reviews and... Jul 2015The Magnet model proposes an accreditation for hospitals having demonstrated a healthy work environment and, as a result, positive staff and patient outcomes. Yet there... (Review)
Review
BACKGROUND
The Magnet model proposes an accreditation for hospitals having demonstrated a healthy work environment and, as a result, positive staff and patient outcomes. Yet there are conflicting findings surrounding the actual impact of Magnet's organizational model on these outcomes, as well as a wide range of designs influencing the quality of these results.
OBJECTIVES
To conduct a systematic review that explores the effect of Magnet accreditation on objective nurse and patient outcomes.
TYPES OF PARTICIPANTS
Magnet and non-Magnet accredited hospitals matched according to their similarity (e.g. size, type [urban or rural], level of acuity, location, etc.). Hospitals could be either university based or non-teaching hospitals and in any geographical location. As the focus of the study was outcomes specific to Magnet accreditation, studies reporting on "reputational Magnets" (the original hospitals), Magnet-aspiring and non-Magnet hospitals alone were excluded from the review. TYPES OF INTERVENTION(S)/PHENOMENA OF INTEREST: Exposure to Magnet accreditation. A Magnet hospital is defined as a hospital with American Nursing Credentialing Center -designated Magnet status at the time of study and having received this accreditation in the last four years, as this is the length of time for which the accreditation is valid, after which the hospital must reapply for another four-year accreditation. TYPES OF STUDIES: This review considered any quantitative study comparing nurse and patient outcomes in Magnet accredited hospitals with those in non-Magnet hospitals. Controlled clinical trials, controlled before and after and interrupted time series were considered first. When these were not available, case-controlled, descriptive comparative and descriptive correlational designs were considered. All studies presenting a "case study" with no comparison and other studies reporting on interviews and other qualitative data were excluded. TYPES OF OUTCOMES: The outcomes of interest were nurse outcomes related to turnover and absenteeism, as measured by the actual turnover rate if available, or the Anticipated Turnover Scale, the Revised Nursing Work Index or the Maslach Burnout Inventory, as well as nursing-sensitive patient outcomes (such as fall rates and hospital-acquired pressure ulcers) as measured by retrospective patient records, discharge abstracts, incident reports and reimbursement forms.
SEARCH STRATEGY
Both published and unpublished literature between 1994 and 2014 were searched. The electronic databases searched were the following: CINAHL, MEDLINE, EMBASE, Academic Search Complete and Web of Science. Other resources included ProQuest Dissertations & Theses Database /Dissertation Abstracts Online and OpenGrey, the American Hospital Association and the American Nurses Credentialing Center websites, and the Sigma Theta Tau International library of abstracts. In April 2015, a search update was conducted including the years 2014-2015 in the databases listed above.
METHODOLOGICAL QUALITY
No cut-off point for the Joanna Briggs Institute appraisal tool criteria was selected for inclusion of studies.
DATA EXTRACTION
Data from included studies were extracted using the Joanna Briggs Institute Data Extraction Form for experimental/observational studies. Two reviewers extracted the data independently and results were compared for accuracy and categorized according to nurse and patient outcomes.
DATA SYNTHESIS
All the studies analyzed retrospective data obtained from either combined databases or from questionnaires. The methodological heterogeneity and poor quality of the designs did not make it possible to pool quantitative results in a statistical meta-analysis. Results are presented in descriptive narrative form.
RESULTS
From the 141 screened studies, ten met the inclusion criteria. Nine of these studies were retrospective analyses of data extracted from existing databases, one study collected original data. Of the seven studies examining patient outcomes, three found clear statistically significant improvements related to lower pressure ulcers, patient falls, failure to rescue and 30-day inpatient mortality in Magnet hospitals compared to non-Magnet hospitals. In the studies examining nurse outcomes, three found statistically significant improvements related to higher job satisfaction and lower intent to leave and turnover rates in Magnet compared to non-Magnet hospitals.
CONCLUSIONS
Based on the mixed results and poor quality in the research designs in the ten included studies, it was not possible to conclude that Magnet accreditation has effects on nurse and patient outcomes. There is a need for more robust designs that can confidently measure the impact of hospital accreditation on objective outcomes.
Topics: Accreditation; Hospitals; Humans; Job Satisfaction; Models, Organizational; Nursing Staff, Hospital; Outcome Assessment, Health Care; Personnel Turnover; United States
PubMed: 26455752
DOI: 10.11124/jbisrir-2015-2262 -
The Journal of Prosthetic Dentistry Sep 2022Although mandibular implant-supported overdentures have been highly recommended as a treatment option, a consensus on the type of attachment systems that can be used to... (Review)
Review
STATEMENT OF PROBLEM
Although mandibular implant-supported overdentures have been highly recommended as a treatment option, a consensus on the type of attachment systems that can be used to increase implant and prostheses survivability is lacking.
PURPOSE
The purpose of this systematic review and meta-analysis was to compare different types of attachments for retention by investigating outcome measures such as implant and prosthesis survival rates and biological and prosthesis complications in participants with a mandibular implant-supported overdenture.
MATERIAL AND METHODS
The search was performed in the PubMed, Cochrane, Embase, and Scopus databases by following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria and registered with the International Prospective Register of Systematic Reviews (CRD42021253566). An analysis of association was conducted between different attachment systems and implant and overdenture survival rates in randomized controlled clinical trials.
RESULTS
The initial search indicated 477 studies, of which 25 randomized controlled trials (RCTs) were included for analysis. A total of 2154 implants and 737 overdentures were analyzed in the meta-analysis. The main results indicated the failure rate for dental implants to be 2.0% (95% confidence interval [CI], 1.3 to 3.2) and overdentures 4.2% (95% CI, 1.6 to 10.5), respectively. With regard to different attachment systems, a similar failure rate was identified with bar-type retention (7.7% to 95% CI, 3.0 to 18.1), magnetic retention systems (7.6% to 95% CI, 2.2 to 22.7), and ball-type retention (6.8% to 95% CI, 3.0 to 14.3). No significant difference was found in biological complications for splinted and unsplinted implant overdentures (P=.902). Regarding prosthetic complications, the most favorable groups were LOCATOR attachments followed by telescopic and Conus, bar, and ball attachments. Magnet attachments had higher prosthetic complications (7.4 times) than the other attachments.
CONCLUSIONS
Implants and implant-supported mandibular overdentures showed a high survival rate irrespective of the attachment system used. Splinting implants did not significantly affect the rate of biological complications. Prosthetic complications were most common for magnet and least common for LOCATOR attachments.
PubMed: 36115712
DOI: 10.1016/j.prosdent.2022.08.004