JMIR MHealth and UHealth Nov 2020With the rise of mobile medicine, the development of new technologies such as smart sensing, and the popularization of personalized health concepts, the field of smart... (Review)
Review
BACKGROUND
With the rise of mobile medicine, the development of new technologies such as smart sensing, and the popularization of personalized health concepts, the field of smart wearable devices has developed rapidly in recent years. Among them, medical wearable devices have become one of the most promising fields. These intelligent devices not only assist people in pursuing a healthier lifestyle but also provide a constant stream of health care data for disease diagnosis and treatment by actively recording physiological parameters and tracking metabolic status. Therefore, wearable medical devices have the potential to become a mainstay of the future mobile medical market.
OBJECTIVE
Although previous reviews have discussed consumer trends in wearable electronics and the application of wearable technology in recreational and sporting activities, data on broad clinical usefulness are lacking. We aimed to review the current application of wearable devices in health care while highlighting shortcomings for further research. In addition to daily health and safety monitoring, the focus of our work was mainly on the use of wearable devices in clinical practice.
METHODS
We conducted a narrative review of the use of wearable devices in health care settings by searching papers in PubMed, EMBASE, Scopus, and the Cochrane Library published since October 2015. Potentially relevant papers were then compared to determine their relevance and reviewed independently for inclusion.
RESULTS
A total of 82 relevant papers drawn from 960 papers on the subject of wearable devices in health care settings were qualitatively analyzed, and the information was synthesized. Our review shows that the wearable medical devices developed so far have been designed for use on all parts of the human body, including the head, limbs, and torso. These devices can be classified into 4 application areas: (1) health and safety monitoring, (2) chronic disease management, (3) disease diagnosis and treatment, and (4) rehabilitation. However, the wearable medical device industry currently faces several important limitations that prevent further use of wearable technology in medical practice, such as difficulties in achieving user-friendly solutions, security and privacy concerns, the lack of industry standards, and various technical bottlenecks.
CONCLUSIONS
We predict that with the development of science and technology and the popularization of personalized health concepts, wearable devices will play a greater role in the field of health care and become better integrated into people's daily lives. However, more research is needed to explore further applications of wearable devices in the medical field. We hope that this review can provide a useful reference for the development of wearable medical devices.
Topics: Delivery of Health Care; Health Facilities; Humans; Technology; Wearable Electronic Devices
PubMed: 33164904
DOI: 10.2196/18907 -
European Respiratory Review : An... Dec 2021Treatment of obstructive sleep apnoea (OSA) in adults is evolving, as new therapies have been explored and introduced in clinical practice, while other approaches have... (Review)
Review
Treatment of obstructive sleep apnoea (OSA) in adults is evolving, as new therapies have been explored and introduced in clinical practice, while other approaches have been refined or reconsidered. In this European Respiratory Society (ERS) guideline on non-continuous positive airway pressure (CPAP) therapies for OSA, we present recommendations determined by a systematic review of the literature. It is an update of the 2011 ERS statement on non-CPAP therapies, advanced into a clinical guideline. A multidisciplinary group of experts, including pulmonary, surgical, dentistry and ear-nose-throat specialists, methodologists and patient representatives considered the most relevant clinical questions (for both clinicians and patients) relating to the management of OSA. Eight key clinical questions were generated and a systematic review was conducted to identify published randomised clinical trials that answered these questions. We used the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach to assess the quality of the evidence and the strength of recommendations. The resulting guideline addresses gastric bypass surgery, custom-made dual-block mandibular advancement devices, hypoglossal nerve stimulation, myofunctional therapy, maxillo-mandibular osteotomy, carbonic anhydrase inhibitors and positional therapy. These recommendations can be used to benchmark quality of care for people with OSA across Europe and to improve outcomes.
Topics: Adult; Continuous Positive Airway Pressure; Humans; Mandibular Advancement; Occlusal Splints; Respiratory System; Sleep Apnea, Obstructive
PubMed: 34853097
DOI: 10.1183/16000617.0200-2021 -
Anaesthesia Jun 2016Postoperative sore throat has a reported incidence of up to 62% following general anaesthesia. In adults undergoing tracheal intubation, female sex, younger age,... (Review)
Review
Postoperative sore throat has a reported incidence of up to 62% following general anaesthesia. In adults undergoing tracheal intubation, female sex, younger age, pre-existing lung disease, prolonged duration of anaesthesia and the presence of a blood-stained tracheal tube on extubation are associated with the greatest risk. Tracheal intubation without neuromuscular blockade, use of double-lumen tubes, as well as high tracheal tube cuff pressures may also increase the risk of postoperative sore throat. The expertise of the anaesthetist performing tracheal intubation appears to have no influence on the incidence in adults, although it may in children. In adults, the i-gel(™) supraglottic airway device results in a lower incidence of postoperative sore throat. Cuffed supraglottic airway devices should be inflated sufficiently to obtain an adequate seal and intracuff pressure should be monitored. Children with respiratory tract disease are at increased risk. The use of supraglottic airway devices, oral, rather than nasal, tracheal intubation and cuffed, rather than uncuffed, tracheal tubes have benefit in reducing the incidence of postoperative sore throat in children. Limiting both tracheal tube and supraglottic airway device cuff pressure may also reduce the incidence.
Topics: Airway Management; Anti-Inflammatory Agents, Non-Steroidal; Humans; Intubation, Intratracheal; Laryngeal Masks; Lidocaine; Pharyngitis; Postoperative Complications; Risk Factors
PubMed: 27158989
DOI: 10.1111/anae.13438 -
Journal of Reconstructive Microsurgery Mar 2021Microsurgical free tissue transfer has become a reliable technique with success rates around 99% and around 5% requiring exploration for vascular compromise....
BACKGROUND
Microsurgical free tissue transfer has become a reliable technique with success rates around 99% and around 5% requiring exploration for vascular compromise. Protocols for flap monitoring between plastic surgery units vary. We aimed to elucidate the time period when monitoring is crucial for flap salvage.
METHODS
A systematic search of literature was performed in PubMed, Cochrane Library, Medline, and Scopus databases from 1966 to July 2018 according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, identifying 3,844 studies with mention of free flap and monitoring or timing or salvage or compromise. Studies were screened for relevance according to predetermined inclusion criteria. Data was extracted from included studies relating to flap type, monitoring, timing and reason for failure, and success of salvage intervention.
RESULTS
A total of 109 studies featuring 44,031 free flaps were included. A total of 2,549 (5.8%) flaps required return to theater for compromise; 926 (2.1%) were lost and 1,654 (3.7%) were salvaged. In the first 24 hours postoperatively 93.8% of explored flaps are successfully salvaged, by day 2: 83.33%, day 3: 12.1%, and beyond day 4: none were successful. Of the 355 flaps where the cause of failure was reported, 59.5% was venous, 27.9% was arterial, 2.3% was a combination of both, and 10.2% was hematoma or infection. The proportion of flap failures at various recipient sites was highest in the trunk/viscera (7%, 95% confidence interval [CI] 0.00, 0.36), followed by limbs (5%, 95% CI 0.02, 0.08), head and neck (3%, 95% CI 0.02, 0.04), and breast (<1%; 95% CI 0.00, 0.02).
CONCLUSION
Close flap monitoring is of most value in the first 48 hours postoperatively, facilitating rapid detection of vascular compromise, early salvage, and better outcomes. The location of the flap has implications on its success and certain recipient sites may need particular attention to improve chances of success.
Topics: Free Tissue Flaps; Humans; Postoperative Complications; Plastic Surgery Procedures; Retrospective Studies; Salvage Therapy; Surgery, Plastic
PubMed: 33395711
DOI: 10.1055/s-0040-1722182 -
International Journal of Environmental... Nov 2020In conditions of intensive therapy, where the patients treated are in a critical condition, alarms are omnipresent. Nurses, as they spend most of their time with...
BACKGROUND
In conditions of intensive therapy, where the patients treated are in a critical condition, alarms are omnipresent. Nurses, as they spend most of their time with patients, monitoring their condition 24 h, are particularly exposed to so-called alarm fatigue. The purpose of this study is to review the literature available on the perception of clinical alarms by nursing personnel and its impact on work in the ICU environment.
METHODS
A systematic review of the literature was carried out according to the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) protocol. The content of electronic databases was searched through, i.e., PubMed, OVID, EBSCO, ProQuest Nursery, and Cochrane Library. The keywords used in the search included: "intensive care unit," "nurse," "alarm fatigue," "workload," and "clinical alarm." The review also covered studies carried out among nurses employed at an adult intensive care unit. Finally, seven publications were taken into consideration. Data were analyzed both descriptively and quantitatively, calculating a weighted average for specific synthetized data.
RESULTS
In the analyzed studies, 389 nurses were tested, working in different intensive care units. Two studies were based on a quality model, while the other five described the problem of alarms in terms of quantity, based on the HTF (Healthcare Technology Foundation) questionnaire. Intensive care nurses think that alarms are burdensome and too frequent, interfering with caring for patients and causing reduced trust in alarm systems. They feel overburdened with an excessive amount of duties and a continuous wave of alarms. Having to operate modern equipment, which is becoming more and more advanced, takes time that nurses would prefer to dedicate to their patients. There is no clear system for managing the alarms of monitoring devices.
CONCLUSION
Alarm fatigue may have serious consequences, both for patients and for nursing personnel. It is necessary to introduce a strategy of alarm management and for measuring the alarm fatigue level.
Topics: Adult; Clinical Alarms; Cross-Sectional Studies; Fatigue; Female; Humans; Intensive Care Units; Monitoring, Physiologic; Stress, Psychological
PubMed: 33202907
DOI: 10.3390/ijerph17228409 -
Journal of Medical Internet Research Jan 2023The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest.
OBJECTIVE
This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN).
METHODS
Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets.
RESULTS
Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=-1.01; 95% CI -1.47 to -0.55; P<.001) and CN method (SMD=-0.46; 95% CI -0.64 to -0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI -0.62 to 0.74; P=.73).
CONCLUSIONS
The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant-guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement.
Topics: Humans; Augmented Reality; Dental Implants; Surgery, Computer-Assisted; Surgeons; Technology
PubMed: 36598798
DOI: 10.2196/42040 -
Sensors (Basel, Switzerland) May 2021Recently, there has been an increase in the production of devices to monitor mental health and stress as means for expediting detection, and subsequent management of... (Review)
Review
Recently, there has been an increase in the production of devices to monitor mental health and stress as means for expediting detection, and subsequent management of these conditions. The objective of this review is to identify and critically appraise the most recent smart devices and wearable technologies used to identify depression, anxiety, and stress, and the physiological process(es) linked to their detection. The MEDLINE, CINAHL, Cochrane Central, and PsycINFO databases were used to identify studies which utilised smart devices and wearable technologies to detect or monitor anxiety, depression, or stress. The included articles that assessed stress and anxiety unanimously used heart rate variability (HRV) parameters for detection of anxiety and stress, with the latter better detected by HRV and electroencephalogram (EGG) together. Electrodermal activity was used in recent studies, with high accuracy for stress detection; however, with questionable reliability. Depression was found to be largely detected using specific EEG signatures; however, devices detecting depression using EEG are not currently available on the market. This systematic review highlights that average heart rate used by many commercially available smart devices is not as accurate in the detection of stress and anxiety compared with heart rate variability, electrodermal activity, and possibly respiratory rate.
Topics: Heart Rate; Mental Health; Monitoring, Physiologic; Reproducibility of Results; Wearable Electronic Devices
PubMed: 34065620
DOI: 10.3390/s21103461 -
Sensors (Basel, Switzerland) Oct 2022Heat-related illnesses, which range from heat exhaustion to heatstroke, affect thousands of individuals worldwide every year and are characterized by extreme... (Review)
Review
Heat-related illnesses, which range from heat exhaustion to heatstroke, affect thousands of individuals worldwide every year and are characterized by extreme hyperthermia with the core body temperature (CBT) usually > 40 °C, decline in physical and athletic performance, CNS dysfunction, and, eventually, multiorgan failure. The measurement of CBT has been shown to predict heat-related illness and its severity, but the current measurement methods are not practical for use in high acuity and high motion settings due to their invasive and obstructive nature or excessive costs. Noninvasive predictions of CBT using wearable technology and predictive algorithms offer the potential for continuous CBT monitoring and early intervention to prevent HRI in athletic, military, and intense work environments. Thus far, there has been a lack of peer-reviewed literature assessing the efficacy of wearable devices and predictive analytics to predict CBT to mitigate heat-related illness. This systematic review identified 20 studies representing a total of 25 distinct algorithms to predict the core body temperature using wearable technology. While a high accuracy in prediction was noted, with 17 out of 18 algorithms meeting the clinical validity standards. few algorithms incorporated individual and environmental data into their core body temperature prediction algorithms, despite the known impact of individual health and situational and environmental factors on CBT. Robust machine learning methods offer the ability to develop more accurate, reliable, and personalized CBT prediction algorithms using wearable devices by including additional data on user characteristics, workout intensity, and the surrounding environment. The integration and interoperability of CBT prediction algorithms with existing heat-related illness prevention and treatment tools, including heat indices such as the WBGT, athlete management systems, and electronic medical records, will further prevent HRI and increase the availability and speed of data access during critical heat events, improving the clinical decision-making process for athletic trainers and physicians, sports scientists, employers, and military officers.
Topics: Body Temperature; Heat Stress Disorders; Heat Stroke; Hot Temperature; Humans; Technology; Wearable Electronic Devices
PubMed: 36236737
DOI: 10.3390/s22197639 -
Clinical and Experimental Dental... Feb 2022The purpose of this systematic review and meta-analysis was to compare implant-supported removable partial dentures (ISRPDs) with distal extension removable partial... (Meta-Analysis)
Meta-Analysis Review
Implant-supported removable partial dentures compared to conventional dentures: A systematic review and meta-analysis of quality of life, patient satisfaction, and biomechanical complications.
OBJECTIVES
The purpose of this systematic review and meta-analysis was to compare implant-supported removable partial dentures (ISRPDs) with distal extension removable partial dentures (DERPDs) in terms of patient-reported outcome measures (PROMs: patients' quality of life and satisfaction) and to determine mechanical and biological complications associated with ISRPDs.
MATERIAL AND METHODS
An electronic search was performed on four databases to identify studies treating Kennedy class I or II edentulous patients and which compared ISRPDs with DERPDs in terms of PROMS and studies, which evaluated mechanical and biological complications associated ISRPDs. Two authors independently extracted data on quality of life, patient satisfaction, and biomechanical complications from these studies. The risk of bias was assessed for each study, and for PROMs, the authors performed a meta-analysis by using a random-effects model.
RESULTS
Thirteen articles were included based on the selection criteria. The difference in mean scores for quality of life (30.5 ± 1.8; 95% confidence interval [CI], 24.9-36.1) and patient satisfaction (-20.8 ± 0.2; 95% CI, -23.7 to -17.8) between treatments with conventional and implant-supported removable dentures was statistically significant (p < .05). Implant-supported removable dentures improved patients' overall quality of life and satisfaction. Some mechanical and biological complications, such as clasp adjustment, abutment or implant loosening, marginal bone resorption, and peri-implant mucositis, were noted in ISRPDs during patient follow-up. Studies assessing PROMs were very heterogeneous (I = 65%, p = .85; I = 75%, p = .88).
CONCLUSIONS
ISRPDs significantly improved quality of life and patient satisfaction. Some mechanical and biological complications have been associated with ISRPDs treatment, requiring regular monitoring of patients to avoid the occurrence of these complications.
Topics: Dental Implants; Dental Prosthesis, Implant-Supported; Denture, Partial, Removable; Humans; Patient Satisfaction; Quality of Life
PubMed: 35014207
DOI: 10.1002/cre2.521 -
Implant Dentistry Dec 2016Occlusal overload may cause implant biomechanical failures, marginal bone loss, or even complete loss of osseointegration. Thus, it is important for clinicians to... (Review)
Review
PURPOSE
Occlusal overload may cause implant biomechanical failures, marginal bone loss, or even complete loss of osseointegration. Thus, it is important for clinicians to understand the role of occlusion in implant long-term stability. This systematic review updates the understanding of occlusion on dental implants, the impact on the surrounding peri-implant tissues, and the effects of occlusal overload on implants. Additionally, recommendations of occlusal scheme for implant prostheses and designs were formulated.
MATERIALS AND METHODS
Two reviewers completed a literature search using the PubMed database and a manual search of relevant journals. Relevant articles from January 1950 to September 20, 2015 published in the English language were considered.
RESULTS
Recommendations for implant occlusion are lacking in the literature. Despite this, implant occlusion should be carefully addressed.
CONCLUSION
Recommendations for occlusal schemes for single implants or fixed partial denture supported by implants include a mutually protected occlusion with anterior guidance and evenly distributed contacts with wide freedom in centric relation. Suggestions to reduce occlusal overload include reducing cantilevers, increasing the number of implants, increasing contact points, monitoring for parafunctional habits, narrowing the occlusal table, decreasing cuspal inclines, and using progressive loading in patients with poor bone quality. Protecting the implant and surrounding peri-implant bone requires an understanding of how occlusion plays a role in influencing long-term implant stability.
Topics: Bite Force; Dental Implantation; Dental Implants; Dental Occlusion; Dental Prosthesis Retention; Humans
PubMed: 27749518
DOI: 10.1097/ID.0000000000000488