The Cochrane Database of Systematic... Aug 2021Pressure ulcers (also known as pressure injuries, pressure sores and bed sores) are localised injuries to the skin or underlying soft tissue, or both, caused by... (Review)
Review
BACKGROUND
Pressure ulcers (also known as pressure injuries, pressure sores and bed sores) are localised injuries to the skin or underlying soft tissue, or both, caused by unrelieved pressure, shear or friction. Specific kinds of beds, overlays and mattresses are widely used with the aim of preventing and treating pressure ulcers.
OBJECTIVES
To summarise evidence from Cochrane Reviews that assess the effects of beds, overlays and mattresses on reducing the incidence of pressure ulcers and on increasing pressure ulcer healing in any setting and population. To assess the relative effects of different types of beds, overlays and mattresses for reducing the incidence of pressure ulcers and increasing pressure ulcer healing in any setting and population. To cumulatively rank the different treatment options of beds, overlays and mattresses in order of their effectiveness in pressure ulcer prevention and treatment.
METHODS
In July 2020, we searched the Cochrane Library. Cochrane Reviews reporting the effectiveness of beds, mattresses or overlays for preventing or treating pressure ulcers were eligible for inclusion in this overview. Two review authors independently screened search results and undertook data extraction and risk of bias assessment using the ROBIS tool. We summarised the reported evidence in an overview of reviews. Where possible, we included the randomised controlled trials from each included review in network meta-analyses. We assessed the relative effectiveness of beds, overlays and mattresses for preventing or treating pressure ulcers and their probabilities of being, comparably, the most effective treatment. We assessed the certainty of the evidence using the GRADE approach.
MAIN RESULTS
We include six Cochrane Reviews in this overview of reviews, all at low or unclear risk of bias. Pressure ulcer prevention: four reviews (of 68 studies with 18,174 participants) report direct evidence for 27 pairwise comparisons between 12 types of support surface on the following outcomes: pressure ulcer incidence, time to pressure ulcer incidence, patient comfort response, adverse event rates, health-related quality of life, and cost-effectiveness. Here we focus on outcomes with some evidence at a minimum of low certainty. (1) Pressure ulcer incidence: our overview includes direct evidence for 27 comparisons that mostly (19/27) have very low-certainty evidence concerning reduction of pressure ulcer risk. We included 40 studies (12,517 participants; 1298 participants with new ulcers) in a network meta-analysis involving 13 types of intervention. Data informing the network are sparse and this, together with the high risk of bias in most studies informing the network, means most network contrasts (64/78) yield evidence of very low certainty. There is low-certainty evidence that, compared with foam surfaces (reference treatment), reactive air surfaces (e.g. static air overlays) (risk ratio (RR) 0.46, 95% confidence interval (CI) 0.29 to 0.75), alternating pressure (active) air surfaces (e.g. alternating pressure air mattresses, large-celled ripple mattresses) (RR 0.63, 95% CI 0.42 to 0.93), and reactive gel surfaces (e.g. gel pads used on operating tables) (RR 0.47, 95% CI 0.22 to 1.01) may reduce pressure ulcer incidence. The ranking of treatments in terms of effectiveness is also of very low certainty for all interventions. It is unclear which treatment is best for preventing ulceration. (2) Time to pressure ulcer incidence: four reviews had direct evidence on this outcome for seven comparisons. We included 10 studies (7211 participants; 699 participants with new ulcers) evaluating six interventions in a network meta-analysis. Again, data from most network contrasts (13/15) are of very low certainty. There is low-certainty evidence that, compared with foam surfaces (reference treatment), reactive air surfaces may reduce the hazard of developing new pressure ulcers (hazard ratio (HR) 0.20, 95% CI 0.04 to 1.05). The ranking of all support surfaces for preventing pressure ulcers in terms of time to healing is uncertain. (3) Cost-effectiveness: this overview includes direct evidence for three comparisons. For preventing pressure ulcers, alternating pressure air surfaces are probably more cost-effective than foam surfaces (moderate-certainty evidence). Pressure ulcer treatment: two reviews (of 12 studies with 972 participants) report direct evidence for five comparisons on: complete pressure ulcer healing, time to complete pressure ulcer healing, patient comfort response, adverse event rates, and cost-effectiveness. Here we focus on outcomes with some evidence at a minimum of low certainty. (1) Complete pressure ulcer healing: our overview includes direct evidence for five comparisons. There is uncertainty about the relative effects of beds, overlays and mattresses on ulcer healing. The corresponding network meta-analysis (with four studies, 397 participants) had only three direct contrasts and a total of six network contrasts. Again, most network contrasts (5/6) have very low-certainty evidence. There was low-certainty evidence that more people with pressure ulcers may heal completely using reactive air surfaces than using foam surfaces (RR 1.32, 95% CI 0.96 to 1.80). We are uncertain which surfaces have the highest probability of being the most effective (all very low-certainty evidence). (2) Time to complete pressure ulcer healing: this overview includes direct evidence for one comparison: people using reactive air surfaces may be more likely to have healed pressure ulcers compared with those using foam surfaces in long-term care settings (HR 2.66, 95% CI 1.34 to 5.17; low-certainty evidence). (3) Cost-effectiveness: this overview includes direct evidence for one comparison: compared with foam surfaces, reactive air surfaces may cost an extra 26 US dollars for every ulcer-free day in the first year of use in long-term care settings (low-certainty evidence).
AUTHORS' CONCLUSIONS
Compared with foam surfaces, reactive air surfaces may reduce pressure ulcer risk and may increase complete ulcer healing. Compared with foam surfaces, alternating pressure air surfaces may reduce pressure ulcer risk and are probably more cost-effective in preventing pressure ulcers. Compared with foam surfaces, reactive gel surfaces may reduce pressure ulcer risk, particularly for people in operating rooms and long-term care settings. There are uncertainties for the relative effectiveness of other support surfaces for preventing and treating pressure ulcers, and their efficacy ranking. More high-quality research is required; for example, for the comparison of reactive air surfaces with alternating pressure air surfaces. Future studies should consider time-to-event outcomes and be designed to minimise any risk of bias.
Topics: Bedding and Linens; Beds; Humans; Incidence; Network Meta-Analysis; Pressure Ulcer; Quality of Life; Randomized Controlled Trials as Topic
PubMed: 34398473
DOI: 10.1002/14651858.CD013761.pub2 -
The Cochrane Database of Systematic... Jul 2021Dementia is a progressive global cognitive impairment syndrome. In 2010, more than 35 million people worldwide were estimated to be living with dementia. Some people... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Dementia is a progressive global cognitive impairment syndrome. In 2010, more than 35 million people worldwide were estimated to be living with dementia. Some people with mild cognitive impairment (MCI) will progress to dementia but others remain stable or recover full function. There is great interest in finding good predictors of dementia in people with MCI. The Mini-Mental State Examination (MMSE) is the best-known and the most often used short screening tool for providing an overall measure of cognitive impairment in clinical, research and community settings.
OBJECTIVES
To determine the accuracy of the Mini Mental State Examination for the early detection of dementia in people with mild cognitive impairment SEARCH METHODS: We searched ALOIS (Cochrane Dementia and Cognitive Improvement Specialized Register of diagnostic and intervention studies (inception to May 2014); MEDLINE (OvidSP) (1946 to May 2014); EMBASE (OvidSP) (1980 to May 2014); BIOSIS (Web of Science) (inception to May 2014); Web of Science Core Collection, including the Conference Proceedings Citation Index (ISI Web of Science) (inception to May 2014); PsycINFO (OvidSP) (inception to May 2014), and LILACS (BIREME) (1982 to May 2014). We also searched specialized sources of diagnostic test accuracy studies and reviews, most recently in May 2014: MEDION (Universities of Maastricht and Leuven, www.mediondatabase.nl), DARE (Database of Abstracts of Reviews of Effects, via the Cochrane Library), HTA Database (Health Technology Assessment Database, via the Cochrane Library), and ARIF (University of Birmingham, UK, www.arif.bham.ac.uk). No language or date restrictions were applied to the electronic searches and methodological filters were not used as a method to restrict the search overall so as to maximize sensitivity. We also checked reference lists of relevant studies and reviews, tracked citations in Scopus and Science Citation Index, used searches of known relevant studies in PubMed to track related articles, and contacted research groups conducting work on MMSE for dementia diagnosis to try to locate possibly relevant but unpublished data.
SELECTION CRITERIA
We considered longitudinal studies in which results of the MMSE administered to MCI participants at baseline were obtained and the reference standard was obtained by follow-up over time. We included participants recruited and clinically classified as individuals with MCI under Petersen and revised Petersen criteria, Matthews criteria, or a Clinical Dementia Rating = 0.5. We used acceptable and commonly used reference standards for dementia in general, Alzheimer's dementia, Lewy body dementia, vascular dementia and frontotemporal dementia.
DATA COLLECTION AND ANALYSIS
We screened all titles generated by the electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility and extracted data to create two by two tables for dementia in general and other dementias. Two authors independently performed quality assessment using the QUADAS-2 tool. Due to high heterogeneity and scarcity of data, we derived estimates of sensitivity at fixed values of specificity from the model we fitted to produce the summary receiver operating characteristic curve.
MAIN RESULTS
In this review, we included 11 heterogeneous studies with a total number of 1569 MCI patients followed for conversion to dementia. Four studies assessed the role of baseline scores of the MMSE in conversion from MCI to all-cause dementia and eight studies assessed this test in conversion from MCI to Alzheimer´s disease dementia. Only one study provided information about the MMSE and conversion from MCI to vascular dementia. For conversion from MCI to dementia in general, the accuracy of baseline MMSE scores ranged from sensitivities of 23% to 76% and specificities from 40% to 94%. In relationship to conversion from MCI to Alzheimer's disease dementia, the accuracy of baseline MMSE scores ranged from sensitivities of 27% to 89% and specificities from 32% to 90%. Only one study provided information about conversion from MCI to vascular dementia, presenting a sensitivity of 36% and a specificity of 80% with an incidence of vascular dementia of 6.2%. Although we had planned to explore possible sources of heterogeneity, this was not undertaken due to the scarcity of studies included in our analysis.
AUTHORS' CONCLUSIONS
Our review did not find evidence supporting a substantial role of MMSE as a stand-alone single-administration test in the identification of MCI patients who could develop dementia. Clinicians could prefer to request additional and extensive tests to be sure about the management of these patients. An important aspect to assess in future updates is if conversion to dementia from MCI stages could be predicted better by MMSE changes over time instead of single measurements. It is also important to assess if a set of tests, rather than an isolated one, may be more successful in predicting conversion from MCI to dementia.
Topics: Alzheimer Disease; Cognitive Dysfunction; Dementia; Dementia, Vascular; Disease Progression; Early Diagnosis; Frontotemporal Dementia; Humans; Lewy Body Disease; Mental Status and Dementia Tests; Neuropsychological Tests; Sensitivity and Specificity
PubMed: 34313331
DOI: 10.1002/14651858.CD010783.pub3 -
The Cochrane Database of Systematic... Feb 2018Surgical site infection (SSI) rates vary from 1% to 5% in the month following surgery. Due to the large number of surgical procedures conducted annually, the costs of... (Review)
Review
BACKGROUND
Surgical site infection (SSI) rates vary from 1% to 5% in the month following surgery. Due to the large number of surgical procedures conducted annually, the costs of these SSIs can be considerable in financial and social terms. Many interventions are used with the aim of reducing the risk of SSI in people undergoing surgery. These interventions can be broadly delivered at three stages: preoperatively, intraoperatively and postoperatively. The intraoperative interventions are largely focused on decontamination of skin using soap and antiseptics; the use of barriers to prevent movement of micro-organisms into incisions; and optimising the patient's own bodily functions to promote best recovery. Both decontamination and barrier methods can be aimed at people undergoing surgery and operating staff. Other interventions focused on SSI prevention may be aimed at the surgical environment and include methods of theatre cleansing and approaches to managing theatre traffic.
OBJECTIVES
To present an overview of Cochrane Reviews of the effectiveness and safety of interventions, delivered during the intraoperative period, aimed at preventing SSIs in all populations undergoing surgery in an operating theatre.
METHODS
Published Cochrane systematic reviews reporting the effectiveness of interventions delivered during the intraoperative period in terms of SSI prevention were eligible for inclusion in this overview. We also identified Cochrane protocols and title registrations for future inclusion into the overview. We searched the Cochrane Library on 01 July 2017. Two review authors independently screened search results and undertook data extraction and 'Risk of bias' and certainty assessment. We used the ROBIS (risk of bias in systematic reviews) tool to assess the quality of included reviews, and we used GRADE methods to assess the certainty of the evidence for each outcome. We summarised the characteristics of included reviews in the text and in additional tables.
MAIN RESULTS
We included 32 Cochrane Reviews in this overview: we judged 30 reviews as being at low risk of bias and two at unclear risk of bias. Thirteen reviews had not been updated in the past three years. Two reviews had no relevant data to extract. We extracted data from 30 reviews with 349 included trials, totaling 73,053 participants. Interventions assessed included gloving, use of disposable face masks, patient oxygenation protocols, use of skin antiseptics for hand washing and patient skin preparation, vaginal preparation, microbial sealants, methods of surgical incision, antibiotic prophylaxis and methods of skin closure. Overall, the GRADE certainty of evidence for outcomes was low or very low. Of the 77 comparisons providing evidence for the outcome of SSI, seven provided high- or moderate-certainty evidence, 39 provided low-certainty evidence and 31 very low-certainty evidence. Of the nine comparisons that provided evidence for the outcome of mortality, five provided low-certainty evidence and four very low-certainty evidence.There is high- or moderate-certainty evidence for the following outcomes for these intraoperative interventions. (1) Prophylactic intravenous antibiotics administered before caesarean incision reduce SSI risk compared with administration after cord clamping (10 trials, 5041 participants; risk ratio (RR) 0.59, 95% confidence interval (CI) 0.44 to 0.81; high-certainty evidence - assessed by review authors). (2) Preoperative antibiotics reduce SSI risk compared with placebo after breast cancer surgery (6 trials, 1708 participants; RR 0.74, 95% CI 0.56 to 0.98; high-certainty evidence - assessed by overview authors). (3) Antibiotic prophylaxis probably reduce SSI risk in caesarean sections compared with no antibiotics (82 relevant trials, 14,407 participants; RR 0.40, 95% CI 0.35 to 0.46; moderate-certainty evidence; downgraded once for risk of bias - assessed by review authors). (4) Antibiotic prophylaxis probably reduces SSI risk for hernia repair compared with placebo or no treatment (17 trials, 7843 participants; RR 0.67, 95% CI 0.54 to 0.84; moderate-certainty evidence; downgraded once for risk of bias - assessed by overview authors); (5) There is currently no clear difference in the risk of SSI between iodine-impregnated adhesive drapes compared with no adhesive drapes (2 trials, 1113 participants; RR 1.03, 95% CI 0.66 to 1.60; moderate-certainty evidence; downgraded once for imprecision - assessed by review authors); (6) There is currently no clear difference in SSI risk between short-term compared with long-term duration antibiotics in colorectal surgery (7 trials; 1484 participants; RR 1.05 95% CI 0.78 to 1.40; moderate-certainty evidence; downgraded once for imprecision - assessed by overview authors). There was only one comparison showing negative effects associated with the intervention: adhesive drapes increase the risk of SSI compared with no drapes (5 trials; 3082 participants; RR 1.23, 95% CI 1.02 to 1.48; high-certainty evidence - rated by review authors).
AUTHORS' CONCLUSIONS
This overview provides the most up-to-date evidence on use of intraoperative treatments for the prevention of SSIs from all currently published Cochrane Reviews. There is evidence that some interventions are useful in reducing SSI risk for people undergoing surgery, such as antibiotic prophylaxis for caesarean section and hernia repair, and also the timing of prophylactic intravenous antibiotics administered before caesarean incision. Also, there is evidence that adhesive drapes increase SSI risk. Evidence for the many other treatment choices is largely of low or very low certainty and no quality-of-life or cost-effectiveness data were reported. Future trials should elucidate the relative effects of some treatments. These studies should focus on increasing participant numbers, using robust methodology and being of sufficient duration to adequately assess SSI. Assessment of other outcomes such as mortality might also be investigated as part of non-experimental prospective follow-up of people with SSI of different severity, so the risk of death for different subgroups can be better understood.
Topics: Humans; Intraoperative Care; Review Literature as Topic; Surgical Wound Infection
PubMed: 29406579
DOI: 10.1002/14651858.CD012653.pub2 -
The Cochrane Database of Systematic... May 2021Pressure ulcers (also known as pressure injuries, pressure sores, decubitus ulcers and bed sores) are localised injuries to the skin or underlying soft tissue, or both,... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Pressure ulcers (also known as pressure injuries, pressure sores, decubitus ulcers and bed sores) are localised injuries to the skin or underlying soft tissue, or both, caused by unrelieved pressure, shear or friction. Alternating pressure (active) air surfaces are widely used with the aim of preventing pressure ulcers.
OBJECTIVES
To assess the effects of alternating pressure (active) air surfaces (beds, mattresses or overlays) compared with any support surface on the incidence of pressure ulcers in any population in any setting.
SEARCH METHODS
In November 2019, we searched the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations); Ovid Embase and EBSCO CINAHL Plus. We also searched clinical trials registries for ongoing and unpublished studies, and scanned reference lists of relevant included studies as well as reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting.
SELECTION CRITERIA
We included randomised controlled trials that allocated participants of any age to alternating pressure (active) air beds, overlays or mattresses. Comparators were any beds, overlays or mattresses.
DATA COLLECTION AND ANALYSIS
At least two review authors independently assessed studies using predetermined inclusion criteria. We carried out data extraction, 'Risk of bias' assessment using the Cochrane 'Risk of bias' tool, and the certainty of the evidence assessment according to Grading of Recommendations, Assessment, Development and Evaluations methodology.
MAIN RESULTS
We included 32 studies (9058 participants) in the review. Most studies were small (median study sample size: 83 participants). The average age of participants ranged from 37.2 to 87.0 years (median: 69.1 years). Participants were largely from acute care settings (including accident and emergency departments). We synthesised data for six comparisons in the review: alternating pressure (active) air surfaces versus: foam surfaces, reactive air surfaces, reactive water surfaces, reactive fibre surfaces, reactive gel surfaces used in the operating room followed by foam surfaces used on the ward bed, and another type of alternating pressure air surface. Of the 32 included studies, 25 (78.1%) presented findings which were considered at high overall risk of bias.
PRIMARY OUTCOME
pressure ulcer incidence Alternating pressure (active) air surfaces may reduce the proportion of participants developing a new pressure ulcer compared with foam surfaces (risk ratio (RR) 0.63, 95% confidence interval (CI) 0.34 to 1.17; I = 63%; 4 studies, 2247 participants; low-certainty evidence). Alternating pressure (active) air surfaces applied on both operating tables and hospital beds may reduce the proportion of people developing a new pressure ulcer compared with reactive gel surfaces used on operating tables followed by foam surfaces applied on hospital beds (RR 0.22, 95% CI 0.06 to 0.76; I = 0%; 2 studies, 415 participants; low-certainty evidence). It is uncertain whether there is a difference in the proportion of people developing new pressure ulcers between alternating pressure (active) air surfaces and the following surfaces, as all these comparisons have very low-certainty evidence: (1) reactive water surfaces; (2) reactive fibre surfaces; and (3) reactive air surfaces. The comparisons between different types of alternating pressure air surfaces are presented narratively. Overall, all comparisons suggest little to no difference between these surfaces in pressure ulcer incidence (7 studies, 2833 participants; low-certainty evidence). Included studies have data on time to pressure ulcer incidence for three comparisons. When time to pressure ulcer development is considered using a hazard ratio (HR), it is uncertain whether there is a difference in the risk of developing new pressure ulcers, over 90 days' follow-up, between alternating pressure (active) air surfaces and foam surfaces (HR 0.41, 95% CI 0.10 to 1.64; I = 86%; 2 studies, 2105 participants; very low-certainty evidence). For the comparison with reactive air surfaces, there is low-certainty evidence that people treated with alternating pressure (active) air surfaces may have a higher risk of developing an incident pressure ulcer than those treated with reactive air surfaces over 14 days' follow-up (HR 2.25, 95% CI 1.05 to 4.83; 1 study, 308 participants). Neither of the two studies with time to ulcer incidence data suggested a difference in the risk of developing an incident pressure ulcer over 60 days' follow-up between different types of alternating pressure air surfaces. Secondary outcomes The included studies have data on (1) support-surface-associated patient comfort for comparisons involving foam surfaces, reactive air surfaces, reactive fibre surfaces and alternating pressure (active) air surfaces; (2) adverse events for comparisons involving foam surfaces, reactive gel surfaces and alternating pressure (active) air surfaces; and (3) health-related quality of life outcomes for the comparison involving foam surfaces. However, all these outcomes and comparisons have low or very low-certainty evidence and it is uncertain whether there are any differences in these outcomes. Included studies have data on cost effectiveness for two comparisons. Moderate-certainty evidence suggests that alternating pressure (active) air surfaces are probably more cost-effective than foam surfaces (1 study, 2029 participants) and that alternating pressure (active) air mattresses are probably more cost-effective than overlay versions of this technology for people in acute care settings (1 study, 1971 participants).
AUTHORS' CONCLUSIONS
Current evidence is uncertain about the difference in pressure ulcer incidence between using alternating pressure (active) air surfaces and other surfaces (reactive water surfaces, reactive fibre surfaces and reactive air surfaces). Alternating pressure (active) air surfaces may reduce pressure ulcer risk compared with foam surfaces and reactive gel surfaces used on operating tables followed by foam surfaces applied on hospital beds. People using alternating pressure (active) air surfaces may be more likely to develop new pressure ulcers over 14 days' follow-up than those treated with reactive air surfaces in the nursing home setting; but as the result is sensitive to the choice of outcome measure it should be interpreted cautiously. Alternating pressure (active) air surfaces are probably more cost-effective than reactive foam surfaces in preventing new pressure ulcers. Future studies should include time-to-event outcomes and assessment of adverse events and trial-level cost-effectiveness. Further review using network meta-analysis will add to the findings reported here.
Topics: Adult; Aged; Aged, 80 and over; Air; Bedding and Linens; Beds; Bias; Elasticity; Humans; Incidence; Middle Aged; Pressure; Pressure Ulcer; Publication Bias; Quality of Life; Randomized Controlled Trials as Topic; Time Factors
PubMed: 33969911
DOI: 10.1002/14651858.CD013620.pub2 -
The Cochrane Database of Systematic... Apr 2015There is evidence that water-loss dehydration is common in older people and associated with many causes of morbidity and mortality. However, it is unclear what clinical... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
There is evidence that water-loss dehydration is common in older people and associated with many causes of morbidity and mortality. However, it is unclear what clinical symptoms, signs and tests may be used to identify early dehydration in older people, so that support can be mobilised to improve hydration before health and well-being are compromised.
OBJECTIVES
To determine the diagnostic accuracy of state (one time), minimally invasive clinical symptoms, signs and tests to be used as screening tests for detecting water-loss dehydration in older people by systematically reviewing studies that have measured a reference standard and at least one index test in people aged 65 years and over. Water-loss dehydration was defined primarily as including everyone with either impending or current water-loss dehydration (including all those with serum osmolality ≥ 295 mOsm/kg as being dehydrated).
SEARCH METHODS
Structured search strategies were developed for MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL, LILACS, DARE and HTA databases (The Cochrane Library), and the International Clinical Trials Registry Platform (ICTRP). Reference lists of included studies and identified relevant reviews were checked. Authors of included studies were contacted for details of further studies.
SELECTION CRITERIA
Titles and abstracts were scanned and all potentially relevant studies obtained in full text. Inclusion of full text studies was assessed independently in duplicate, and disagreements resolved by a third author. We wrote to authors of all studies that appeared to have collected data on at least one reference standard and at least one index test, and in at least 10 people aged ≥ 65 years, even where no comparative analysis has been published, requesting original dataset so we could create 2 x 2 tables.
DATA COLLECTION AND ANALYSIS
Diagnostic accuracy of each test was assessed against the best available reference standard for water-loss dehydration (serum or plasma osmolality cut-off ≥ 295 mOsm/kg, serum osmolarity or weight change) within each study. For each index test study data were presented in forest plots of sensitivity and specificity. The primary target condition was water-loss dehydration (including either impending or current water-loss dehydration). Secondary target conditions were intended as current (> 300 mOsm/kg) and impending (295 to 300 mOsm/kg) water-loss dehydration, but restricted to current dehydration in the final review.We conducted bivariate random-effects meta-analyses (Stata/IC, StataCorp) for index tests where there were at least four studies and study datasets could be pooled to construct sensitivity and specificity summary estimates. We assigned the same approach for index tests with continuous outcome data for each of three pre-specified cut-off points investigated.Pre-set minimum sensitivity of a useful test was 60%, minimum specificity 75%. As pre-specifying three cut-offs for each continuous test may have led to missing a cut-off with useful sensitivity and specificity, we conducted post-hoc exploratory analyses to create receiver operating characteristic (ROC) curves where there appeared some possibility of a useful cut-off missed by the original three. These analyses enabled assessment of which tests may be worth assessing in further research. A further exploratory analysis assessed the value of combining the best two index tests where each had some individual predictive ability.
MAIN RESULTS
There were few published studies of the diagnostic accuracy of state (one time), minimally invasive clinical symptoms, signs or tests to be used as screening tests for detecting water-loss dehydration in older people. Therefore, to complete this review we sought, analysed and included raw datasets that included a reference standard and an index test in people aged ≥ 65 years.We included three studies with published diagnostic accuracy data and a further 21 studies provided datasets that we analysed. We assessed 67 tests (at three cut-offs for each continuous outcome) for diagnostic accuracy of water-loss dehydration (primary target condition) and of current dehydration (secondary target condition).Only three tests showed any ability to diagnose water-loss dehydration (including both impending and current water-loss dehydration) as stand-alone tests: expressing fatigue (sensitivity 0.71 (95% CI 0.29 to 0.96), specificity 0.75 (95% CI 0.63 to 0.85), in one study with 71 participants, but two additional studies had lower sensitivity); missing drinks between meals (sensitivity 1.00 (95% CI 0.59 to 1.00), specificity 0.77 (95% CI 0.64 to 0.86), in one study with 71 participants) and BIA resistance at 50 kHz (sensitivities 1.00 (95% CI 0.48 to 1.00) and 0.71 (95% CI 0.44 to 0.90) and specificities of 1.00 (95% CI 0.69 to 1.00) and 0.80 (95% CI 0.28 to 0.99) in 15 and 22 people respectively for two studies, but with sensitivities of 0.54 (95% CI 0.25 to 0.81) and 0.69 (95% CI 0.56 to 0.79) and specificities of 0.50 (95% CI 0.16 to 0.84) and 0.19 (95% CI 0.17 to 0.21) in 21 and 1947 people respectively in two other studies). In post-hoc ROC plots drinks intake, urine osmolality and axillial moisture also showed limited diagnostic accuracy. No test was consistently useful in more than one study.Combining two tests so that an individual both missed some drinks between meals and expressed fatigue was sensitive at 0.71 (95% CI 0.29 to 0.96) and specific at 0.92 (95% CI 0.83 to 0.97).There was sufficient evidence to suggest that several stand-alone tests often used to assess dehydration in older people (including fluid intake, urine specific gravity, urine colour, urine volume, heart rate, dry mouth, feeling thirsty and BIA assessment of intracellular water or extracellular water) are not useful, and should not be relied on individually as ways of assessing presence or absence of dehydration in older people.No tests were found consistently useful in diagnosing current water-loss dehydration.
AUTHORS' CONCLUSIONS
There is limited evidence of the diagnostic utility of any individual clinical symptom, sign or test or combination of tests to indicate water-loss dehydration in older people. Individual tests should not be used in this population to indicate dehydration; they miss a high proportion of people with dehydration, and wrongly label those who are adequately hydrated.Promising tests identified by this review need to be further assessed, as do new methods in development. Combining several tests may improve diagnostic accuracy.
Topics: Aged; Dehydration; Drinking Water; Electric Impedance; Female; Humans; Male; Mouth Diseases; Osmolar Concentration; Sensitivity and Specificity; Skin Physiological Phenomena; Symptom Assessment; Urine
PubMed: 25924806
DOI: 10.1002/14651858.CD009647.pub2 -
The Cochrane Database of Systematic... Mar 2015Dementia is a progressive global cognitive impairment syndrome. In 2010, more than 35 million people worldwide were estimated to be living with dementia. Some people... (Review)
Review
BACKGROUND
Dementia is a progressive global cognitive impairment syndrome. In 2010, more than 35 million people worldwide were estimated to be living with dementia. Some people with mild cognitive impairment (MCI) will progress to dementia but others remain stable or recover full function. There is great interest in finding good predictors of dementia in people with MCI. The Mini-Mental State Examination (MMSE) is the best-known and the most often used short screening tool for providing an overall measure of cognitive impairment in clinical, research and community settings.
OBJECTIVES
To determine the diagnostic accuracy of the MMSE at various thresholds for detecting individuals with baseline MCI who would clinically convert to dementia in general, Alzheimer's disease dementia or other forms of dementia at follow-up.
SEARCH METHODS
We searched ALOIS (Cochrane Dementia and Cognitive Improvement Specialized Register of diagnostic and intervention studies (inception to May 2014); MEDLINE (OvidSP) (1946 to May 2014); EMBASE (OvidSP) (1980 to May 2014); BIOSIS (Web of Science) (inception to May 2014); Web of Science Core Collection, including the Conference Proceedings Citation Index (ISI Web of Science) (inception to May 2014); PsycINFO (OvidSP) (inception to May 2014), and LILACS (BIREME) (1982 to May 2014). We also searched specialized sources of diagnostic test accuracy studies and reviews, most recently in May 2014: MEDION (Universities of Maastricht and Leuven, www.mediondatabase.nl), DARE (Database of Abstracts of Reviews of Effects, via the Cochrane Library), HTA Database (Health Technology Assessment Database, via the Cochrane Library), and ARIF (University of Birmingham, UK, www.arif.bham.ac.uk). No language or date restrictions were applied to the electronic searches and methodological filters were not used as a method to restrict the search overall so as to maximize sensitivity. We also checked reference lists of relevant studies and reviews, tracked citations in Scopus and Science Citation Index, used searches of known relevant studies in PubMed to track related articles, and contacted research groups conducting work on MMSE for dementia diagnosis to try to locate possibly relevant but unpublished data.
SELECTION CRITERIA
We considered longitudinal studies in which results of the MMSE administered to MCI participants at baseline were obtained and the reference standard was obtained by follow-up over time. We included participants recruited and clinically classified as individuals with MCI under Petersen and revised Petersen criteria, Matthews criteria, or a Clinical Dementia Rating = 0.5. We used acceptable and commonly used reference standards for dementia in general, Alzheimer's dementia, Lewy body dementia, vascular dementia and frontotemporal dementia.
DATA COLLECTION AND ANALYSIS
We screened all titles generated by the electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility and extracted data to create two by two tables for dementia in general and other dementias. Two authors independently performed quality assessment using the QUADAS-2 tool. Due to high heterogeneity and scarcity of data, we derived estimates of sensitivity at fixed values of specificity from the model we fitted to produce the summary receiver operating characteristic curve.
MAIN RESULTS
In this review, we included 11 heterogeneous studies with a total number of 1569 MCI patients followed for conversion to dementia. Four studies assessed the role of baseline scores of the MMSE in conversion from MCI to all-cause dementia and eight studies assessed this test in conversion from MCI to Alzheimer´s disease dementia. Only one study provided information about the MMSE and conversion from MCI to vascular dementia. For conversion from MCI to dementia in general, the accuracy of baseline MMSE scores ranged from sensitivities of 23% to 76% and specificities from 40% to 94%. In relationship to conversion from MCI to Alzheimer's disease dementia, the accuracy of baseline MMSE scores ranged from sensitivities of 27% to 89% and specificities from 32% to 90%. Only one study provided information about conversion from MCI to vascular dementia, presenting a sensitivity of 36% and a specificity of 80% with an incidence of vascular dementia of 6.2%. Although we had planned to explore possible sources of heterogeneity, this was not undertaken due to the scarcity of studies included in our analysis.
AUTHORS' CONCLUSIONS
Our review did not find evidence supporting a substantial role of MMSE as a stand-alone single-administration test in the identification of MCI patients who could develop dementia. Clinicians could prefer to request additional and extensive tests to be sure about the management of these patients. An important aspect to assess in future updates is if conversion to dementia from MCI stages could be predicted better by MMSE changes over time instead of single measurements. It is also important to assess if a set of tests, rather than an isolated one, may be more successful in predicting conversion from MCI to dementia.
Topics: Alzheimer Disease; Cognitive Dysfunction; Dementia; Dementia, Vascular; Disease Progression; Frontotemporal Dementia; Humans; Lewy Body Disease; Mental Status Schedule; Neuropsychological Tests; Sensitivity and Specificity
PubMed: 25740785
DOI: 10.1002/14651858.CD010783.pub2 -
The Cochrane Database of Systematic... Apr 2019Rapid and accurate detection of stroke by paramedics or other emergency clinicians at the time of first contact is crucial for timely initiation of appropriate...
BACKGROUND
Rapid and accurate detection of stroke by paramedics or other emergency clinicians at the time of first contact is crucial for timely initiation of appropriate treatment. Several stroke recognition scales have been developed to support the initial triage. However, their accuracy remains uncertain and there is no agreement which of the scales perform better.
OBJECTIVES
To systematically identify and review the evidence pertaining to the test accuracy of validated stroke recognition scales, as used in a prehospital or emergency room (ER) setting to screen people suspected of having stroke.
SEARCH METHODS
We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid) and the Science Citation Index to 30 January 2018. We handsearched the reference lists of all included studies and other relevant publications and contacted experts in the field to identify additional studies or unpublished data.
SELECTION CRITERIA
We included studies evaluating the accuracy of stroke recognition scales used in a prehospital or ER setting to identify stroke and transient Ischemic attack (TIA) in people suspected of stroke. The scales had to be applied to actual people and the results compared to a final diagnosis of stroke or TIA. We excluded studies that applied scales to patient records; enrolled only screen-positive participants and without complete 2 × 2 data.
DATA COLLECTION AND ANALYSIS
Two review authors independently conducted a two-stage screening of all publications identified by the searches, extracted data and assessed the methodologic quality of the included studies using a tailored version of QUADAS-2. A third review author acted as an arbiter. We recalculated study-level sensitivity and specificity with 95% confidence intervals (CI), and presented them in forest plots and in the receiver operating characteristics (ROC) space. When a sufficient number of studies reported the accuracy of the test in the same setting (prehospital or ER) and the level of heterogeneity was relatively low, we pooled the results using the bivariate random-effects model. We plotted the results in the summary ROC (SROC) space presenting an estimate point (mean sensitivity and specificity) with 95% CI and prediction regions. Because of the small number of studies, we did not conduct meta-regression to investigate between-study heterogeneity and the relative accuracy of the scales. Instead, we summarized the results in tables and diagrams, and presented our findings narratively.
MAIN RESULTS
We selected 23 studies for inclusion (22 journal articles and one conference abstract). We evaluated the following scales: Cincinnati Prehospital Stroke Scale (CPSS; 11 studies), Recognition of Stroke in the Emergency Room (ROSIER; eight studies), Face Arm Speech Time (FAST; five studies), Los Angeles Prehospital Stroke Scale (LAPSS; five studies), Melbourne Ambulance Stroke Scale (MASS; three studies), Ontario Prehospital Stroke Screening Tool (OPSST; one study), Medic Prehospital Assessment for Code Stroke (MedPACS; one study) and PreHospital Ambulance Stroke Test (PreHAST; one study). Nine studies compared the accuracy of two or more scales. We considered 12 studies at high risk of bias and one with applicability concerns in the patient selection domain; 14 at unclear risk of bias and one with applicability concerns in the reference standard domain; and the risk of bias in the flow and timing domain was high in one study and unclear in another 16.We pooled the results from five studies evaluating ROSIER in the ER and five studies evaluating LAPSS in a prehospital setting. The studies included in the meta-analysis of ROSIER were of relatively good methodologic quality and produced a summary sensitivity of 0.88 (95% CI 0.84 to 0.91), with the prediction interval ranging from approximately 0.75 to 0.95. This means that the test will miss on average 12% of people with stroke/TIA which, depending on the circumstances, could range from 5% to 25%. We could not obtain a reliable summary estimate of specificity due to extreme heterogeneity in study-level results. The summary sensitivity of LAPSS was 0.83 (95% CI 0.75 to 0.89) and summary specificity 0.93 (95% CI 0.88 to 0.96). However, we were uncertain in the validity of these results as four of the studies were at high and one at uncertain risk of bias. We did not report summary estimates for the rest of the scales, as the number of studies per test per setting was small, the risk of bias was high or uncertain, the results were highly heterogenous, or a combination of these.Studies comparing two or more scales in the same participants reported that ROSIER and FAST had similar accuracy when used in the ER. In the field, CPSS was more sensitive than MedPACS and LAPSS, but had similar sensitivity to that of MASS; and MASS was more sensitive than LAPSS. In contrast, MASS, ROSIER and MedPACS were more specific than CPSS; and the difference in the specificities of MASS and LAPSS was not statistically significant.
AUTHORS' CONCLUSIONS
In the field, CPSS had consistently the highest sensitivity and, therefore, should be preferred to other scales. Further evidence is needed to determine its absolute accuracy and whether alternatives scales, such as MASS and ROSIER, which might have comparable sensitivity but higher specificity, should be used instead, to achieve better overall accuracy. In the ER, ROSIER should be the test of choice, as it was evaluated in more studies than FAST and showed consistently high sensitivity. In a cohort of 100 people of whom 62 have stroke/TIA, the test will miss on average seven people with stroke/TIA (ranging from three to 16). We were unable to obtain an estimate of its summary specificity. Because of the small number of studies per test per setting, high risk of bias, substantial differences in study characteristics and large between-study heterogeneity, these findings should be treated as provisional hypotheses that need further verification in better-designed studies.
Topics: Humans; Ischemic Attack, Transient; Mass Screening; Randomized Controlled Trials as Topic; Severity of Illness Index; Stroke
PubMed: 30964558
DOI: 10.1002/14651858.CD011427.pub2 -
Diagnostics (Basel, Switzerland) May 2021The objective of this review was to compile validated functional shoulder assessment tools and analyse the methodological quality of their validations. Secondarily, we... (Review)
Review
The objective of this review was to compile validated functional shoulder assessment tools and analyse the methodological quality of their validations. Secondarily, we aimed to provide a comparison of the tools, including parameter descriptions, indications/applications, languages and operating instructions, to choose the most suitable for future clinical and research approaches. A systematic review (PRISMA) was conducted using: PubMed, WoS Scopus, CINHAL, Dialnet and reference lists until 2020. The main criteria for inclusion were that papers were original studies of validated tools or validation studies. Pre-established tables showed tools, validations, items/components, etc. The QUADAS-2 and COSMIN-RB were used to assess the methodological quality of validations. Ultimately, 85 studies were selected, 32 tools and 111 validations. Risk of bias scored lower than applicability, and patient selection got the best scores (QUADAS-2). Internal consistency had the highest quality and PROMs development the lowest (COSMIN-RB). Responsiveness was the most analysed metric property. Modified UCLA and SST obtained the highest quality in shoulder instability surgery, and SPADI in pain. The most approached topic was activities of daily living (81%). We compiled 32 validated functional shoulder assessment tools, and conducted an analysis of the methodological quality of 111 validations associated with them. Modified UCLA and SST showed the highest methodological quality in instability surgery and SPADI in pain.
PubMed: 34066777
DOI: 10.3390/diagnostics11050845 -
Obstetrics and Gynecology Jan 2021To systematically review the performance of soluble fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF), and the sFlt-1/PlGF ratio in predicting adverse... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To systematically review the performance of soluble fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF), and the sFlt-1/PlGF ratio in predicting adverse outcomes in women with preeclampsia.
DATA SOURCES
We performed a systematic search of MEDLINE, EMBASE, CINAHL, Cochrane, Scopus, ClinicalTrials.gov, and Emcare databases from 1989 to March 2019 to identify studies correlating sFlt-1, PlGF, and the sFlt-1/PlGF ratio with the occurrence of adverse outcomes in women with preeclampsia.
METHODS OF STUDY SELECTION
Two independent reviewers screened 3,194 studies using Covidence. Studies were included if they examined the performance of sFLT-1, PlGF, or the sFLT-1/PlGF ratio in predicting adverse outcomes in women with suspected or confirmed preeclampsia.
TABULATION, INTEGRATION, AND RESULTS
We extracted contingency tables with true-positive, false-positive, true-negative, and false-negative results. We calculated sensitivity, specificity, diagnostic odds ratios, and area under the summary receiver operating characteristic curve (area sROC) through a bivariate mixed-effects meta-analysis. Our literature search identified 3,194 articles, of which 33 (n=9,426 patients) were included. There was significant variation in the included studies with regard to the biomarkers and outcomes assessed. As such, few studies (n=4-8) were included in the meta-analysis component with significant heterogeneity between studies (I2=33-99). Nonetheless, both PlGF and the sFlt-1/PlGF ratio demonstrated area sROC values between 0.68 and 0.87 for the prediction of composite adverse maternal and perinatal outcomes, preterm birth and fetal growth restriction.
CONCLUSION
Placental growth factor and the sFlt-1/PlGF ratio show prognostic promise for adverse outcomes in preeclampsia, but study heterogeneity limits their clinical utility.
SYSTEMATIC REVIEW REGISTRATION
PROSPERO, CRD42019136207.
Topics: Biomarkers; Female; Humans; Placenta Growth Factor; Pre-Eclampsia; Pregnancy; Vascular Endothelial Growth Factor Receptor-1
PubMed: 33278298
DOI: 10.1097/AOG.0000000000004149 -
American Journal of Obstetrics and... Sep 2023This study aimed to: (1) identify all relevant studies reporting on the diagnostic accuracy of maternal circulating placental growth factor) alone or as a ratio with... (Meta-Analysis)
Meta-Analysis Review
Accuracy of placental growth factor alone or in combination with soluble fms-like tyrosine kinase-1 or maternal factors in detecting preeclampsia in asymptomatic women in the second and third trimesters: a systematic review and meta-analysis.
OBJECTIVE
This study aimed to: (1) identify all relevant studies reporting on the diagnostic accuracy of maternal circulating placental growth factor) alone or as a ratio with soluble fms-like tyrosine kinase-1), and of placental growth factor-based models (placental growth factor combined with maternal factors±other biomarkers) in the second or third trimester to predict subsequent development of preeclampsia in asymptomatic women; (2) estimate a hierarchical summary receiver-operating characteristic curve for studies reporting on the same test but different thresholds, gestational ages, and populations; and (3) select the best method to screen for preeclampsia in asymptomatic women during the second and third trimester of pregnancy by comparing the diagnostic accuracy of each method.
DATA SOURCES
A systematic search was performed through MEDLINE, Embase, CENTRAL, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform databases from January 1, 1985 to April 15, 2021.
STUDY ELIGIBILITY CRITERIA
Studies including asymptomatic singleton pregnant women at >18 weeks' gestation with risk of developing preeclampsia were evaluated. We included only cohort or cross-sectional test accuracy studies reporting on preeclampsia outcome, allowing tabulation of 2×2 tables, with follow-up available for >85%, and evaluating performance of placental growth factor alone, soluble fms-like tyrosine kinase-1- placental growth factor ratio, or placental growth factor-based models. The study protocol was registered on the International Prospective Register Of Systematic Reviews (CRD 42020162460).
METHODS
Because of considerable intra- and interstudy heterogeneity, we computed the hierarchical summary receiver-operating characteristic plots and derived diagnostic odds ratios, β, θ, and Λ for each method to compare performances. The quality of the included studies was evaluated by the QUADAS-2 tool.
RESULTS
The search identified 2028 citations, from which we selected 474 studies for detailed assessment of the full texts. Finally, 100 published studies met the eligibility criteria for qualitative and 32 for quantitative syntheses. Twenty-three studies reported on performance of placental growth factor testing for the prediction of preeclampsia in the second trimester, including 16 (with 27 entries) that reported on placental growth factor test alone, 9 (with 19 entries) that reported on the soluble fms-like tyrosine kinase-1-placental growth factor ratio, and 6 (16 entries) that reported on placental growth factor-based models. Fourteen studies reported on performance of placental growth factor testing for the prediction of preeclampsia in the third trimester, including 10 (with 18 entries) that reported on placental growth factor test alone, 8 (with 12 entries) that reported on soluble fms-like tyrosine kinase-1-placental growth factor ratio, and 7 (with 12 entries) that reported on placental growth factor-based models. For the second trimester, Placental growth factor-based models achieved the highest diagnostic odds ratio for the prediction of early preeclampsia in the total population compared with placental growth factor alone and soluble fms-like tyrosine kinase-1-placental growth factor ratio (placental growth factor-based models, 63.20; 95% confidence interval, 37.62-106.16 vs soluble fms-like tyrosine kinase-1-placental growth factor ratio, 6.96; 95% confidence interval, 1.76-27.61 vs placental growth factor alone, 5.62; 95% confidence interval, 3.04-10.38); placental growth factor-based models had higher diagnostic odds ratio than placental growth factor alone for the identification of any-onset preeclampsia in the unselected population (28.45; 95% confidence interval, 13.52-59.85 vs 7.09; 95% confidence interval, 3.74-13.41). For the third trimester, Placental growth factor-based models achieved prediction for any-onset preeclampsia that was significantly better than that of placental growth factor alone but similar to that of soluble fms-like tyrosine kinase-1-placental growth factor ratio (placental growth factor-based models, 27.12; 95% confidence interval, 21.67-33.94 vs placental growth factor alone, 10.31; 95% confidence interval, 7.41-14.35 vs soluble fms-like tyrosine kinase-1-placental growth factor ratio, 14.94; 95% confidence interval, 9.42-23.70).
CONCLUSION
Placental growth factor with maternal factors ± other biomarkers determined in the second trimester achieved the best predictive performance for early preeclampsia in the total population. However, in the third trimester, placental growth factor-based models had predictive performance for any-onset preeclampsia that was better than that of placental growth factor alone but similar to that of soluble fms-like tyrosine kinase-1-placental growth factor ratio. Through this meta-analysis, we have identified a large number of very heterogeneous studies. Therefore, there is an urgent need to develop standardized research using the same models that combine serum placental growth factor with maternal factors ± other biomarkers to accurately predict preeclampsia. Identification of patients at risk might be beneficial for intensive monitoring and timing delivery.
Topics: Female; Humans; Pregnancy; Biomarkers; Cross-Sectional Studies; Placenta Growth Factor; Pre-Eclampsia; Pregnancy Trimester, Third; Vascular Endothelial Growth Factor A; Vascular Endothelial Growth Factor Receptor-1
PubMed: 36990308
DOI: 10.1016/j.ajog.2023.03.032