Current Opinion in Anaesthesiology Dec 2015Electronic medical devices are an integral part of patient care. As new devices are introduced, the number of alarms to which a healthcare professional may be exposed... (Review)
Review
PURPOSE OF REVIEW
Electronic medical devices are an integral part of patient care. As new devices are introduced, the number of alarms to which a healthcare professional may be exposed may be as high as 1000 alarms per shift. The US Food and Drug Administration has reported over 500 alarm-related patient deaths in five years. The Joint Commission, recognizing the clinical significance of alarm fatigue, has made clinical alarm management a National Patient Safety Goal.
RECENT FINDINGS
Potential solutions to alarm fatigue include technical, organizational, and educational interventions. Selecting only the right monitors (i.e., avoiding overmonitoring), judicious selection of alarm limits, and multimodal alarms can all reduce the number of nuisance alarms to which a healthcare worker is exposed.
SUMMARY
Alarm fatigue can jeopardize safety, but some clinical solutions such as setting appropriate thresholds and avoiding overmonitoring are available.
Topics: Clinical Alarms; Fatigue; Humans; Monitoring, Physiologic; Noise; Patient Safety; United States
PubMed: 26539788
DOI: 10.1097/ACO.0000000000000260 -
International Journal of Environmental... Nov 2020In conditions of intensive therapy, where the patients treated are in a critical condition, alarms are omnipresent. Nurses, as they spend most of their time with...
BACKGROUND
In conditions of intensive therapy, where the patients treated are in a critical condition, alarms are omnipresent. Nurses, as they spend most of their time with patients, monitoring their condition 24 h, are particularly exposed to so-called alarm fatigue. The purpose of this study is to review the literature available on the perception of clinical alarms by nursing personnel and its impact on work in the ICU environment.
METHODS
A systematic review of the literature was carried out according to the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) protocol. The content of electronic databases was searched through, i.e., PubMed, OVID, EBSCO, ProQuest Nursery, and Cochrane Library. The keywords used in the search included: "intensive care unit," "nurse," "alarm fatigue," "workload," and "clinical alarm." The review also covered studies carried out among nurses employed at an adult intensive care unit. Finally, seven publications were taken into consideration. Data were analyzed both descriptively and quantitatively, calculating a weighted average for specific synthetized data.
RESULTS
In the analyzed studies, 389 nurses were tested, working in different intensive care units. Two studies were based on a quality model, while the other five described the problem of alarms in terms of quantity, based on the HTF (Healthcare Technology Foundation) questionnaire. Intensive care nurses think that alarms are burdensome and too frequent, interfering with caring for patients and causing reduced trust in alarm systems. They feel overburdened with an excessive amount of duties and a continuous wave of alarms. Having to operate modern equipment, which is becoming more and more advanced, takes time that nurses would prefer to dedicate to their patients. There is no clear system for managing the alarms of monitoring devices.
CONCLUSION
Alarm fatigue may have serious consequences, both for patients and for nursing personnel. It is necessary to introduce a strategy of alarm management and for measuring the alarm fatigue level.
Topics: Adult; Clinical Alarms; Cross-Sectional Studies; Fatigue; Female; Humans; Intensive Care Units; Monitoring, Physiologic; Stress, Psychological
PubMed: 33202907
DOI: 10.3390/ijerph17228409 -
Critical Care Nurse Apr 2023Clinical alarms are designed to signal an unsatisfactory patient physiological state and alert staff members to malfunctioning medical equipment. Alarm desensitization...
BACKGROUND
Clinical alarms are designed to signal an unsatisfactory patient physiological state and alert staff members to malfunctioning medical equipment. Alarm desensitization and fatigue can occur when clinicians are exposed to an overwhelming number of clinical alarms, particularly nonactionable alarms.
LOCAL PROBLEM
Alarm fatigue and alarm management competency related to use of Philips monitoring systems were noted to be problematic among nurses working in the 27-bed surgical intensive care unit of a teaching hospital in northeastern Florida.
METHODS
A quality improvement project was conducted to reduce alarm fatigue and improve nursing competency in managing alarms. The CEASE (Communication, Electrodes, Appropriateness, Setup, and Education) evidence-based alarm management bundle was implemented on the unit, and a representative from the alarm manufacturer conducted in-service training sessions. A clinical alarms survey developed by the Healthcare Technology Foundation was distributed both before and after the intervention to 115 nurses working in the unit. Descriptive and inferential statistics were used to assess for differences between the preintervention and postintervention periods.
RESULTS
Nurse participants demonstrated improved alarm management competency, resulting in significant improvements in their perceptions of alarm functionality, settings, response time, and policy adherence. There was a statistically significant decrease in self-reported alarm fatigue, and the CEASE bundle was found to influence nursing practice.
CONCLUSIONS
The Joint Commission's 2022 goal of improving clinical alarm safety remains a top priority nationwide. Implementation of the CEASE alarm management bundle was effective in reducing surgical intensive care unit nurses' alarm fatigue and improving their alarm management practices.
Topics: Humans; Critical Care; Intensive Care Units; Monitoring, Physiologic; Surveys and Questionnaires; Clinical Alarms; Hospitals, Teaching; Nurses
PubMed: 37001877
DOI: 10.4037/ccn2023418 -
SAGE Open Nursing 2022This evidence-based research project provides an appraisal of current research on how an alarm management program impacts alarm fatigue among registered nurses (RNs) in... (Review)
Review
This evidence-based research project provides an appraisal of current research on how an alarm management program impacts alarm fatigue among registered nurses (RNs) in both intensive care units (ICUs) and telemetry units. Alarm fatigue is a major problem recognized by both the American Association of Critical-Care Nurses (AACN) and the Joint Commission. RNs are the primary caretakers of critically ill patients in ICUs and telemetry units and therefore are at the greatest risk for alarm fatigue. The researchers performed an evidence synthesis to determine the impact of an alarm management program on alarm fatigue among ICU and telemetry RNs. A literature search was conducted using scientific databases such as PubMed, CINAHL, Trip, Cochrane Review, and Google Scholar. Our search strategy included the following terms: adult registered nurse, inpatient registered nurse, ICU registered nurses, RNs, Nurse Practitioners, alarm fatigue, alarm management strategy, education, cardiac monitor alarm, alarm strategies, alarm bundle, telemetry alarm, and cardiac monitor. Any studies involving the pediatric population, pulse oximeter alarms, and ventilator alarms were excluded. Due to the lack of available randomized control trials and cohort studies, the authors included two quality improvement (QI) projects. Finally, six studies were taken into consideration for review. The authors appraised each of the six articles using the Critical Appraisal Skills Programme Checklist (CASP) Tool. This tool allowed the authors to synthesize information based on the outcomes and determine the level of the evidence of each article in order to make evidence-based practice recommendations on implementing alarm management programs. Despite extensive literature highlighting the astronomical prevalence of alarm fatigue in RNs, there was a lack of current high-quality data related to implementing alarm management programs. Therefore, more research is needed to support the utilization of alarm management programs in ICUs and telemetry units to improve alarm fatigue among RNs.
PubMed: 35592038
DOI: 10.1177/23779608221098713 -
Journal of Perinatology : Official... Jan 2018
Topics: Apnea; Bradycardia; Humans; Infant, Newborn; Infant, Premature; Patient Discharge; Patient Readmission
PubMed: 29348520
DOI: 10.1038/jp.2017.175 -
American Journal of Critical Care : An... Sep 2022
Topics: Clinical Alarms; Humans; Monitoring, Physiologic; Patient Safety
PubMed: 36045038
DOI: 10.4037/ajcc2022426 -
Anesthesiology Apr 2023
Topics: Clinical Alarms; Monitoring, Physiologic; Patient Safety
PubMed: 36729394
DOI: 10.1097/ALN.0000000000004499 -
Journal of Clinical Nursing Nov 2020Chaotic monitor alarm management generates a large number of alarms, which result in alarm fatigue. Intensive care unit (ICU) nurses are caretakers of critically ill... (Randomized Controlled Trial)
Randomized Controlled Trial
BACKGROUND
Chaotic monitor alarm management generates a large number of alarms, which result in alarm fatigue. Intensive care unit (ICU) nurses are caretakers of critically ill patients, the effect of alarm management affect patient safety directly.
OBJECTIVES
To evaluate the effect of monitor alarm management training based on the theory of planned behaviour for reducing alarm fatigue in intensive care unit nurses.
DESIGN
A randomised, single-blind trial. This article follows the requirements of CONSORT statement.
PARTICIPANTS
The study was conducted from February 2019-May 2019 in a tertiary A-level hospital. 93 ICU clinical nurses were included, and they were randomly assigned into two groups.
INTERVENTION
Nurses in the experimental group (n = 47) received a 12-week alarm management training course based on the theory of planned behaviour. Nurses in the control group (n = 46) received regular training. All nurses' alarm fatigue scores were measured with a questionnaire before and after the study period. Total number of alarms, nonactionable alarms and true crisis alarms were recorded continuously throughout the study period.
RESULTS
For baseline comparisons, no significant differences were found. By the analysis of independent samples one-way ANCOVAs, the nurses' adjusted alarm fatigue scores at the post-test in the experimental group were significantly lower than those in the control group (p < .001). After the study period, adjusted total number of alarms and nonactionable alarms recorded in the experimental group were both significantly lower than those recorded in the control group (p < .001). After the study period, no significant difference between the two groups was noted in the adjusted number of true crisis alarms (p > .05). The interventions did not cause adverse events in either group of patients and did not cause adverse events in patients.
CONCLUSION
Intensive care unit nurses' alarm fatigue was effectively decreased by the monitor alarm management training based on the theory of planned behaviour.
RELEVANCE TO CLINICAL PRACTICE
(1) Monitor alarm training based on the theory of planned behaviour is effective in reducing nonactionable alarms and lowering alarm fatigue in ICU nurses. (2) The intervention considering the social psychological aspects of behaviour is effective in rebuilding the nurses' awareness and behaviour of alarm management. (3) Nurses are the direct users of monitoring technology. Hospital administrators should attach importance to the role of nurses in the medical monitoring system. We suggest that nursing managers implement training programmes in more ICUs in the future to improve alarm management ability and lower alarm fatigue in ICU nurses.
Topics: Clinical Alarms; Fatigue; Humans; Intensive Care Units; Monitoring, Physiologic; Nursing Staff, Hospital; Single-Blind Method
PubMed: 32780921
DOI: 10.1111/jocn.15452 -
British Journal of Anaesthesia Oct 2023Auditory roughness in medical alarm sounds is an important design attribute, and has been shown to impact user performance and perception. While roughness can assist in...
Auditory roughness in medical alarm sounds is an important design attribute, and has been shown to impact user performance and perception. While roughness can assist in decreased signal-to-noise ratios (perceived loudness) and communicate urgency, it might also impact patient recovery. Therefore, considerations of neuroscience correlates, music theory, and patient impact are critical aspects to investigate in order to optimise alarm design.
Topics: Humans; Sound; Clinical Alarms; Monitoring, Physiologic
PubMed: 37537119
DOI: 10.1016/j.bja.2023.07.003 -
Dimensions of Critical Care Nursing :... 2019The research literature is replete with evidence that alarm fatigue is a real phenomenon in the clinical practice environment and can lead to desensitization of the need...
Research Outcomes of Implementing CEASE: An Innovative, Nurse-Driven, Evidence-Based, Patient-Customized Monitoring Bundle to Decrease Alarm Fatigue in the Intensive Care Unit/Step-down Unit.
INTRODUCTION
The research literature is replete with evidence that alarm fatigue is a real phenomenon in the clinical practice environment and can lead to desensitization of the need to respond among nursing staff. A few studies attest to the effectiveness of incorporating parts of the American Association of Critical-Care Nurses recommended nursing practices for alarm management. No studies could be found measuring the effectiveness of the American Association of Critical-Care Nurses recommendations in their entirety or the effectiveness of a nursing-driven, evidence-based, patient-customized monitoring bundle.
PURPOSE/RESEARCH QUESTION
The purpose of this study was to describe the effect of implementing CEASE, a nurse-driven, evidence-based, patient-customized monitoring bundle on alarm fatigue. CEASE is an acronym for Communication, Electrodes (daily changes), Appropriateness (evaluation), Setup alarm parameters (patient customization), and Education (ongoing).
RESEARCH QUESTIONS
(1) In a 36-bed intensive care unit/step-down unit (ICU/SDU) with continuous hemodynamic and respiratory monitoring, does application of an evidence-based, patient-customized monitoring bundle compared with existing monitoring practice lead to less alarm fatigue as measured by the number of hemodynamic and respiratory monitoring alarms? (2) In a 36-bed ICU/SDU with continuous hemodynamic and respiratory monitoring, does application of an evidence-based, patient-customized monitoring bundle compared with existing monitoring practice lead to less alarm fatigue as measured by duration of alarms? and (3) In a 36-bed ICU/SDU with continuous hemodynamic and respiratory monitoring, does application of an evidence-based, patient-customized monitoring bundle compared with existing monitoring practice lead to less alarm fatigue as measured by nurse perception?
METHODS
This was an institutional review board approved exploratory, nonrandomized, pretest and posttest, 1-group, quasi-experimental study, without-comparators design describing difference in pretest and posttest measures following CEASE Bundle implementation. The study was conducted over a 6-month period. Convenience sample of 74 registered nurses staffing a 36-bed ICU/SDU using the CEASE Bundle participated. Preimplementation/postimplementation number of alarms and alarm duration time for a 30-day period were downloaded from the monitoring system and compared. Nurses completed an electronic 36-item Clinical Alarms Survey provided by the Healthcare Technology Foundation: 35 before implementation and 18 after implementation. Researchers measured CEASE alarm bundle adherence. χ and t-tests determined statistical significance.
RESULTS
Total number of monitoring alarms decreased 31% from 52 880 to 36 780 after CEASE Bundle implementation. Low-priority Level 1 alarms duration time significantly decreased 23 seconds (t = 1.994, P = .045). Level 2 duration time did not change. High-priority Level 3 alarms duration time significantly increased to 246 seconds (t = 4.432, P < .0001). CEASE alarm bundle adherence significantly improved to 22.4% (χ = 5.068, P = .0244). Nurses perceived a significant decrease in nuisance alarm occurrence (68% to 44%) postimplementation (χ = 3.243, P = .0417). No adverse patient events occurred.
CONCLUSIONS
Decreased total number of monitoring alarms improved nurse perception of alarm fatigue. Continued monitoring of CEASE Bundle adherence by nursing staff is required. Longer high-priority Level 3 alarms duration suggests need for further research.
Topics: Clinical Alarms; Critical Care Nursing; Evidence-Based Nursing; Humans; Intensive Care Units; Monitoring, Physiologic; Patient Safety
PubMed: 30946125
DOI: 10.1097/DCC.0000000000000357