Surgical Neurology International 2022A neuroendoscope is a technical advance that allows surgeons to visualize certain regions of the brain that was previously inaccessible through the use of a surgical...
BACKGROUND
A neuroendoscope is a technical advance that allows surgeons to visualize certain regions of the brain that was previously inaccessible through the use of a surgical microscope. Several neuroendoscope designs have been implemented by other neurosurgeons over the past 5 years. The advantage of a neuroendoscope is the addition of a flexible and narrow tip that allows for safe entry into intracranial structures for clinical observation. However, there are some limitations to this approach. Here, we report the use of a modified angioscope as a newly developed neuroendoscope to be employed in observing intracranial structures.
METHODS
We report the use of an angioscope that is 1.8 mm in diameter and has both a thin and flexible tip. In this study, the angioscope was inserted into the lumen of an aspirator tube, and the tip of the device was placed at the intracranial area of intended observation area. Image findings were evaluated using an established goat brain model.
RESULTS
The angioscope was light in weight and maneuverable and could be reached and observed in the blind spot using a surgical microscope. From the cerebellopontine angle, the lower cranial nerves and trigeminal nerve could be observed, and from the cisterna magna, the floor of the fourth ventricle and the aqueduct could be seen.
CONCLUSION
The angioscope is a useful instrument to observe intracranial locations safely and effectively even within a limited surgical field. Further modifications will be required to use the angioscope in various craniotomy procedures.
PubMed: 36324912
DOI: 10.25259/SNI_748_2022 -
Neurosurgery Aug 2014Endoluminal optical imaging, or angioscopy, has not seen widespread application during neurointerventional procedures, largely as a result of the poor imaging resolution...
BACKGROUND
Endoluminal optical imaging, or angioscopy, has not seen widespread application during neurointerventional procedures, largely as a result of the poor imaging resolution of existing angioscopes. Scanning fiber endoscopes (SFEs) are a novel endoscopic platform that allows high-resolution video imaging in an ultraminiature form factor that is compatible with currently used distal access endoluminal catheters.
OBJECTIVE
To test the feasibility and potential utility of high-resolution angioscopy with an SFE during common endovascular neurosurgical procedures.
METHODS
A 3.7-French SFE was used in a porcine model system to image endothelial disruption, ischemic stroke and mechanical thrombectomy, aneurysm coiling, and flow-diverting stent placement.
RESULTS
High-resolution, video-rate imaging was shown to be possible during all of the common procedures tested and provided information that was complementary to standard fluoroscopic imaging. SFE angioscopy was able to assess novel factors such as aneurysm base coverage fraction and side branch patency, which have previously not been possible to determine with conventional angiography.
CONCLUSION
Endovascular imaging with an SFE provides important information on factors that cannot be assessed fluoroscopically and is a novel platform on which future neurointerventional techniques may be based because it allows for periprocedural inspection of the integrity of the vascular system and the deployed devices. In addition, it may be of diagnostic use for inspecting the vascular wall and postprocedure device evaluation.
Topics: Angioscopy; Animals; Disease Models, Animal; Endoscopy; Feasibility Studies; Neurosurgical Procedures; Stroke; Swine
PubMed: 24762703
DOI: 10.1227/NEU.0000000000000383 -
Journal of Endovascular Therapy : An... Apr 2023Despite the increase in the number of patients with peripheral artery disease (PAD), the pathophysiology is not fully elucidated. Recently, angioscopy with a...
BACKGROUND
Despite the increase in the number of patients with peripheral artery disease (PAD), the pathophysiology is not fully elucidated. Recently, angioscopy with a 0.48-megapixel equivalent resolution camera became available for patients with PAD. We aimed to compare the plaque component between native stenosis and occlusion in the femoropopliteal artery using this modality.
MATERIALS AND METHODS
Thirty-two consecutive patients who underwent endovascular treatment for native femoropopliteal artery disease with angioscopy were studied. The major angioscopic classifications of each lesion were defined as follows: atheromatous plaque (AP) was defined as luminal narrowing without any protrusion, calcified nodule (CN) was defined as a protruding bump with surface irregularity, a mainly reddish thrombus was defined as organizing thrombus (OG), and organized thrombus (OD) was defined by more than half of the thrombus showing a whitish intima-like appearance.
RESULTS
A total of 34 lesions (stenosis, n=18; occlusion, n=16) from 32 patients were included. All stenotic lesions showed AP or CN (n=8 [44%], n=10 [56%], respectively), whereas all occluded lesions showed OG or OD (n=5 [31%], n=11 [69%], respectively), which amounted to a statistically significant difference (p<0.001). In occluded lesions, stiff wires (>3 g) were required to cross all lesions classified as OD, whereas this was not always necessary for lesions classified as OG (11 [100%] of 11, 1 [25%] of 5, respectively; p=0.04). Yellow color plaques were observed to a similar degree in all angioscopic classifications. Major adverse limb events, defined as amputation and any reintervention at 12 months, were highly variable, depending on the angioscopic findings, and tended to be more frequently observed in CN and OD (13% in AP, 40% in CN, 0% in OT, and 36% in OD, p=0.25).
CONCLUSION
Angioscopy revealed varying components in stenosis and occlusion with different degrees of clinical impact. This may provide new information on the pathophysiology of PAD.
Topics: Humans; Angioscopy; Constriction, Pathologic; Treatment Outcome; Femoral Artery; Thrombosis; Plaque, Atherosclerotic; Peripheral Arterial Disease; Coronary Vessels
PubMed: 35179063
DOI: 10.1177/15266028221079759 -
Journal of Cardiology Jan 2023Chronic total occlusion (CTO) is a high-risk factor for stent thrombosis, but little is known about the difference in neointimal healing between CTO and non-CTO lesions...
BACKGROUND
Chronic total occlusion (CTO) is a high-risk factor for stent thrombosis, but little is known about the difference in neointimal healing between CTO and non-CTO lesions regarding implanted stents. We investigated factors affecting neointimal healing after stent implantation for CTO and non-CTO lesions using angioscopy.
METHODS
We retrospectively evaluated 106 stents in 85 consecutive patients between March 2016 and July 2020. Their average age was 68 ± 11 years, and participants (73 male and 12 female) underwent follow-up angiography and angioscopy 1 year after percutaneous coronary intervention (PCI). The stents (n = 106) were divided into three groups according to the lesion status at the previous PCI: CTO (n = 17), acute coronary syndrome (ACS) (n = 35), and stable coronary artery disease without CTO or non-CTO (n = 54).
RESULTS
The neointimal stent coverage grade was significantly lower in the CTO and ACS groups than in the non-CTO group (0.4 ± 0.5, 0.9 ± 0.8, and 1.4 ± 0.8, respectively, p < 0.001). Thrombi were significantly more frequent in CTO and ACS than in non-CTO (71 %, 51 %, and 15 %, respectively, p < 0.001). The yellow grade in CTO was comparable to that in ACS but significantly higher in CTO than in non-CTO (CTO vs. ACS vs. non-CTO 1.5 ± 0.7, 1.4 ± 0.6, and 0.9 ± 0.7, respectively, p = 0.007).
CONCLUSIONS
Delayed healing occurs in stents implanted for CTO lesions. Longer dual-antithrombotic therapy may be beneficial.
Topics: Humans; Male; Female; Middle Aged; Aged; Percutaneous Coronary Intervention; Angioscopy; Coronary Thrombosis; Retrospective Studies; Coronary Angiography; Neointima; Treatment Outcome; Coronary Occlusion; Chronic Disease
PubMed: 36057486
DOI: 10.1016/j.jjcc.2022.08.008 -
Journal of Vascular and Interventional... Feb 2022To determine the correlation between upstream atherosclerosis in the femoropopliteal arteries, assessed using angioscopy, and impaired infrapopliteal runoff.
PURPOSE
To determine the correlation between upstream atherosclerosis in the femoropopliteal arteries, assessed using angioscopy, and impaired infrapopliteal runoff.
MATERIALS AND METHODS
Thirty-one patients with peripheral arterial disease who underwent endovascular therapy and angioscopy were prospectively included. Yellow plaque color scores were semiquantitatively determined as 0, 1, 2, or 3. Irregular plaques with rough surfaces, similar to gastric ulcers, were defined as ulcerated plaques (UPs). Angioscopic data were correlated with angiographic runoff scores (ARS).
RESULTS
UPs were detected in 74.2% of enrolled diseased legs using angioscopy. Mural thrombi were more commonly observed in the femoropopliteal artery in patients with UPs than in those without UPs (91.3% vs 37.5%, respectively; P = .006) and were frequently found on the UPs (21/23 patients with UPs). Univariate and multivariate linear regression analyses revealed that the presence of UPs was positively and independently associated with a poor ARS and that oral anticoagulant use was independently associated with a preferable ARS (standardized β = 0.462, P = .004 and standardized β = -0.411, P = .009, respectively, in the multivariate analysis).
CONCLUSIONS
UPs, associated with mural thrombi and diagnosed by angioscopic examination, were demonstrated to be one of the factors associated with poor infrapopliteal runoff.
Topics: Angioscopy; Atherosclerosis; Coronary Vessels; Humans; Risk Factors; Thrombosis
PubMed: 34715323
DOI: 10.1016/j.jvir.2021.10.013 -
Journal of Biomedical Optics Sep 2023The scanning fiber endoscope (SFE), an ultrasmall optical imaging device with a large field-of-view (FOV) for having a clear forward view into the interior of blood...
SIGNIFICANCE
The scanning fiber endoscope (SFE), an ultrasmall optical imaging device with a large field-of-view (FOV) for having a clear forward view into the interior of blood vessels, has great potential in the cardiovascular disease diagnosis and surgery assistance, which is one of the key applications for short-wave infrared biomedical imaging. The state-of-the-art SFE system uses a miniaturized refractive spherical lens doublet for beam projection. A metalens is a promising alternative that can be made much thinner and has fewer off-axis aberrations than its refractive counterpart.
AIM
We demonstrate a transmissive metalens working at 1310 nm for a forward viewing endoscope to achieve a shorter device length and better resolution at large field angles.
APPROACH
We optimize the metalens of the SFE system using Zemax, fabricate it using e-beam lithography, characterize its optical performances, and compare them with the simulations.
RESULTS
The SFE system has a resolution of at the center of field (imaging distance 15 mm), an FOV of , and a depth-of-focus of , which are comparable with a state-of-the-art refractive lens SFE. The use of the metalens reduces the length of the optical track from 1.2 to 0.86 mm. The resolution of our metalens-based SFE drops by less than a factor of 2 at the edge of the FOV, whereas the refractive lens counterpart has a times resolution degradation.
CONCLUSIONS
These results show the promise of integrating a metalens into an endoscope for device minimization and optical performance improvement.
Topics: Endoscopy, Gastrointestinal; Radionuclide Imaging; Refraction, Ocular; Lens, Crystalline; Lenses
PubMed: 36911164
DOI: 10.1117/1.JBO.28.9.094802 -
Open Heart May 2020Coronary angioscopy (CAS) is a useful modality to assess atherosclerotic changes, but interpretation of the images requires expert knowledge. Deep convolutional neural...
BACKGROUND
Coronary angioscopy (CAS) is a useful modality to assess atherosclerotic changes, but interpretation of the images requires expert knowledge. Deep convolutional neural networks (DCNN) can be used for diagnostic prediction and image synthesis.
METHODS
107 images from 47 patients, who underwent CAS in our hospital between 2014 and 2017, and 864 images, selected from 142 MEDLINE-indexed articles published between 2000 and 2019, were analysed. First, we developed a prediction model for the angioscopic findings. Next, we made a generative adversarial networks (GAN) model to simulate the CAS images. Finally, we tried to control the output images according to the angioscopic findings with conditional GAN architecture.
RESULTS
For both yellow colour (YC) grade and neointimal coverage (NC) grade, we could observe strong correlations between the true grades and the predicted values (YC grade, average r=0.80±0.02, p<0.001; NC grade, average r=0.73±0.02, p<0.001). The binary classification model for the red thrombus yielded 0.71±0.03 F-score and the area under the receiver operator characteristic curve was 0.91±0.02. The standard GAN model could generate realistic CAS images (average Inception score=3.57±0.06). GAN-based data augmentation improved the performance of the prediction models. In the conditional GAN model, there were significant correlations between given values and the expert's diagnosis in YC grade but not in NC grade.
CONCLUSION
DCNN is useful in both predictive and generative modelling that can help develop the diagnostic support system for CAS.
Topics: Angioscopy; Coronary Artery Disease; Coronary Vessels; Deep Learning; Humans; Image Interpretation, Computer-Assisted; Predictive Value of Tests; Prognosis; Reproducibility of Results
PubMed: 32404485
DOI: 10.1136/openhrt-2019-001177 -
Journal of Cardiology Jul 2022The plaques with higher grade of yellow color by angioscopy are reported to be associated with vulnerability leading to adverse outcomes in coronary artery diseases....
BACKGROUND
The plaques with higher grade of yellow color by angioscopy are reported to be associated with vulnerability leading to adverse outcomes in coronary artery diseases. However, no studies have been performed for peripheral artery disease (PAD). We aimed to evaluate the relationship of angioscopic findings of peripheral arteries with the long-term prognosis.
METHODS
Angioscopy of iliac or femoropopliteal artery was performed before endovascular therapy in patients with PAD. The local plaque color and presence of thrombus were evaluated. Multivariable Cox regression models were used to estimate hazard ratio (HR) for all-cause mortality or major adverse cardiovascular event (MACE) related to the plaque colors as well as presence of thrombus.
RESULTS
Among 67 patients, 49.3% had intensive yellow plaques (group H) and the rest had light yellow to yellow ones (group L). Thrombus was detected in 74.6% of the patients and the presence was not different between the two groups. In Kaplan-Meier analysis during a median follow-up of 976 days and 757 days, group H showed increased mortality and MACE compared with group L (p <0.01 for both). Multivariable analysis demonstrated that the intensive yellow color of plaque was independently associated with mortality and MACE [HR: 11.48, 95% confidence interval (CI): 2.19-211.1 and HR: 3.81, 95% CI: 1.36-13.48, respectively] after adjusting for the presence of thrombus.
CONCLUSIONS
The yellow color intensity in local plaques by angioscopy may be a novel predictor of long-term prognosis in patients with PAD, regardless of the presence of thrombus.
Topics: Angioscopy; Coronary Artery Disease; Coronary Vessels; Humans; Peripheral Arterial Disease; Plaque, Atherosclerotic; Prognosis
PubMed: 35219551
DOI: 10.1016/j.jjcc.2022.02.004 -
Cureus Jan 2024Background Cholesterol crystals (CCs) are related to innate inflammation in spontaneously ruptured aortic plaques (SRAPs), and variability exists in the CCs and...
Background Cholesterol crystals (CCs) are related to innate inflammation in spontaneously ruptured aortic plaques (SRAPs), and variability exists in the CCs and interleukin (IL)-6 ratio in SRAPs. Methods The prevalence of scattering-type ruptures that glittered against the light of angioscopic fibers (puff-chandelier ruptures) and those that did not (puff ruptures) was analyzed in 848 patients with suspected coronary artery disease. Overall, 177 puff-chandelier ruptures and 105 puff ruptures were sampled using nonobstructive general angioscopy (NOGA). The sampled plaques were analyzed by direct detection of CCs with polarized light microscopy. The characteristics of the plaque fragments from puff and puff-chandelier ruptures were compared. The Interleukin-6 (IL-6) ratios were calculated for 100 puff-chandelier ruptures and 100 puff ruptures. Results CCs were detected in 54% of puff-chandelier ruptures and 20% of puff ruptures. The longer and shorter dimensions of the puff ruptures were smaller than those of the puff-chandelier ruptures. CCs were more prevalent in puff chandeliers than in puff ruptures (54% vs. 20%, respectively; p<0.0001). The number of CCs was higher in puff chandeliers than in puff ruptures with CCs (median 12,727 (interquartile range (IQR) 3,636-25,909)/10 mL vs. median 3,182 ( IQR 909-9,318)/10 mL) in CC-positive samples (p=0.0120). The IL-6 ratio of puff-chandelier ruptures was higher than that of puff ruptures (p=0.0014). Conclusions Examination of plaque fragments from puff-chandelier and puff ruptures revealed a higher prevalence of CCs in puff-chandelier ruptures compared to puff ruptures. Puff chandeliers exhibited a significantly greater number of CCs, suggesting a potential correlation with inflammatory levels. The IL-6 ratio was also higher in puff-chandelier ruptures. Direct detection of CCs and hematoxylin and eosin staining for SRAPs demonstrated variations in CC degree and dimensions between puff-chandelier and puff ruptures. Puff-chandelier ruptures exhibited more CCs associated with innate inflammation and larger fragments than puff ruptures. NOGA proved effective in detecting diverse characteristics and inflammation levels, as indicated by IL-6, in scattering-type SRAPs.
PubMed: 38274622
DOI: 10.7759/cureus.52949