Journal of the American Heart... Sep 2021Background Current guidelines recommend at least 6 months of antithrombotic therapy and antibiotic prophylaxis after septal-occluding device deployment in transcatheter...
Background Current guidelines recommend at least 6 months of antithrombotic therapy and antibiotic prophylaxis after septal-occluding device deployment in transcatheter closure of atrial septal defect. It has been estimated that it takes ≈6 months for complete neo-endothelialization; however, neo-endothelialization has not previously been assessed in vivo in humans. Methods and Results The neointimal coverage of septal occluder devices was evaluated 6 months after implantation in 15 patients by angioscopy from the right atrium. Each occluder surface was divided into 9 areas; the levels of endothelialization in each area were semiquantitatively assessed by 4-point grades. Device neo-endothelialization was sufficient in two thirds of patients, but insufficient in one third. In the comparison between patients with sufficiently endothelialized devices of average grade score ≥2 (good endothelialization group, n=10) and those with poorly endothelialized devices of average grade score <2 (poor endothelialization group, n=5), those in the poor endothelialization group had larger devices deployed (27.0 mm [25.0-31.5 mm] versus 17.0 mm [15.6-22.5 mm], respectively) and progressive right heart dilatation. The endothelialization was poorer around the central areas. Moreover, the prevalence of thrombus formation on the devices was higher in the poorly endothelialized areas than in the sufficiently endothelialized areas (Grade 0, 94.1%; Grade 1, 63.2%; Grade 2, 0%; Grade 3, 1.6%). Conclusions Neo-endothelialization on the closure devices varied 6 months after implantation. Notably, poor endothelialization and thrombus attachment were observed around the central areas and on the larger devices.
Topics: Angioscopy; Heart Septal Defects, Atrial; Humans
PubMed: 34533044
DOI: 10.1161/JAHA.120.019282 -
Journal of Cardiology May 2021Detection of the early stage of atherosclerosis, which does not exhibit macroscopic morphological changes, is currently beyond the scope of any available imaging...
BACKGROUND
Detection of the early stage of atherosclerosis, which does not exhibit macroscopic morphological changes, is currently beyond the scope of any available imaging techniques. Collagens provide mechanical support of vascular wall and subtype I is the major component of the normal vascular wall. During the process of atherosclerosis, collagen III appears first, followed by subtypes IV and V during fibrosis of the intima. Therefore, the presence of collagen III indicates initiation of atherosclerosis. Here, we aimed to visualize collagen subtypes in human coronary wall.
METHODS
Under microscopy, collagen III was stained emerald-green, collagen I was red, and IV and V were pink in the presence of a mixture of Silius red and Fast green dyes. Fifty-one coronary arteries excised from 20 human autopsy subjects were classified by angioscopy and histology as normal segments, white and yellow plaques, and examined after staining collagen subtypes in their superficial layer with the same dye mixtures.
RESULTS
Normal coronary segments with intimal thickness ≦200 μm stained red, with thickness >200 μm stained red and emerald-green in a mosaic pattern or emerald-green alone, yellow plaques without a necrotic core were pink, and those with a necrotic core showed no staining.
CONCLUSION
The results suggested that coronary segments stained red indicate no atherosclerosis, red and emerald-green in a mosaic pattern indicates initiation of atherosclerosis, emerald-green is early-stage atherosclerosis, pink is advanced stage of atherosclerosis, and no staining shows the end stage of atherosclerosis at least in superficial layer of coronary artery. Therefore, dye-staining angioscopy using Silius red and Fast green dyes in combination could be used to detect the early and advanced stage of atherosclerosis in superficial layer of human coronary artery.
Topics: Angioscopy; Collagen; Coronary Artery Disease; Coronary Vessels; Humans; Plaque, Atherosclerotic
PubMed: 33162263
DOI: 10.1016/j.jjcc.2020.09.011 -
Circulation Journal : Official Journal... Oct 2023
Topics: Humans; Saphenous Vein; Angioscopy; Graft Occlusion, Vascular; Calcinosis; Vascular Patency
PubMed: 37704440
DOI: 10.1253/circj.CJ-23-0421 -
Circulation Journal : Official Journal... Aug 2016
Comparative Study
Angioscopic Assessment of Stent Stability and Neointimal Coverage After Implantation of 2nd-Generation Drug-Eluting Stents - Comparison With Bare-Mental Stents and 1st-Generation Drug-Eluting Stents.
Topics: Angioscopy; Drug-Eluting Stents; Humans; Neointima
PubMed: 27488284
DOI: 10.1253/circj.CJ-16-0743 -
Circulation. Cardiovascular... Mar 2023Stepwise provisional stenting is the gold standard for percutaneous coronary intervention (PCI) on bifurcation lesions, but the optimal ballooning technique for eventual...
BACKGROUND
Stepwise provisional stenting is the gold standard for percutaneous coronary intervention (PCI) on bifurcation lesions, but the optimal ballooning technique for eventual side branch treatment is not established. The objective of the present study was to compare the stent configuration obtained by 2 different side branch optimization techniques performed after main vessel (MV) stent implantation: proximal optimization technique+kissing balloon inflation+final proximal optimization technique (POT/KBI/POT [PKP]) versus proximal optimization technique+isolated side branch dilation+final proximal optimization technique (POT-side-POT [PSP]).
METHODS
We realized a 1:1 prospective randomized trial comparing bifurcation PCI conducted (under angiographic and angioscopic visualization) with either PKP or PSP in reanimated swine hearts using commercially available drug-eluting stents. After PCI, the obtained stent configuration (expansion, eccentricity, apposition) was assessed by optical coherence tomography and micro-computed tomography dividing the stent in 4 segments. Primary study end point was minimum stent expansion at the distal MV segment.
RESULTS
A total of 30 PCIs were successfully performed according to randomization obtaining overall good results (average minimum stent expansion >90% at optical coherence tomography and micro-computed tomography) with PSP or PKP. Minimum stent expansion at the distal MV segment was significantly higher with PKP as compared with PSP at optical coherence tomography (97.9±4.2% versus 91.0±7.7%; =0.002) and micro-computed tomography (98.1±4.1% versus 91.3±7.9%; =0.006). Other significant findings included higher stent eccentricity index at proximal MV with PSP, higher side branch scaffolding length and lower malapposition (at bifurcation core and distal MV) with PKP.
CONCLUSIONS
This first prospective randomized trial in a unique non-atherosclerotic preclinical environment showed that bifurcation PCI conducted with PSP and PKP achieves different stent configurations. These findings might be useful in bifurcation PCI practice and call for further evaluations in clinical ground.
Topics: Animals; Coronary Angiography; Coronary Artery Disease; Percutaneous Coronary Intervention; Prospective Studies; Stents; Swine; Treatment Outcome; X-Ray Microtomography
PubMed: 36943931
DOI: 10.1161/CIRCINTERVENTIONS.123.012908 -
Circulation Journal : Official Journal... 2016Drug-eluting stents (DES) have reduced late loss and target lesion revascularization through the inhibition of neointimal hyperplasia, but instead increased the risk of... (Comparative Study)
Comparative Study
BACKGROUND
Drug-eluting stents (DES) have reduced late loss and target lesion revascularization through the inhibition of neointimal hyperplasia, but instead increased the risk of very late stent failure due to incomplete neointimal coverage and neoatherosclerosis. Although newer DES are more effective and safer than the first-generation DES, the difference in the condition of the stented lesions between Resolute zotarolimus-eluting stents (R-ZES) and Endeavor zotarolimus-eluting stents (E-ZES) on angioscopy has not been reported.
METHODS AND RESULTS
Consecutive patients who received R-ZES (n=46) or E-ZES (n=46) for de novo lesion of native coronary artery and had 1-year follow-up angioscopy were examined. Yellow color (grade 0-3), neointimal coverage (grade 0-2), heterogeneity score (maximum-minimum neointimal coverage grade) and thrombus (presence or absence) at stented lesion were evaluated. The maximum yellow color grade (1.2±0.9 vs. 0.7±1.0, P=0.005) was higher in R-ZES than in E-ZES. The maximum (1.9±0.3 vs. 1.5±0.5, P<0.001) and minimum (1.1±0.7 vs. 0.4±0.5, P<0.001) coverage grade was higher in E-ZES than in R-ZES. The heterogeneity score was higher in R-ZES than in E-ZES (1.0±0.5 vs. 0.7±0.7, P=0.007). Prevalence of thrombus was not different between the 2 stents (6.5% vs. 2.2%, P=0.4).
CONCLUSIONS
E-ZES had better neointimal coverage with less yellow plaque and lower heterogeneity score than R-ZES. The lesions with E-ZES appeared more stable than those with R-ZES. (Circ J 2016; 80: 650-656).
Topics: Aged; Angioscopy; Atherosclerosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Neointima; Plaque, Atherosclerotic; Sirolimus
PubMed: 26794153
DOI: 10.1253/circj.CJ-15-1119 -
BMJ Case Reports Jul 2023Little has been reported on the angioscopic and histopathological findings of in-stent restenosis (ISR) in the iliac artery. Here, we report a case of a male patient in...
Little has been reported on the angioscopic and histopathological findings of in-stent restenosis (ISR) in the iliac artery. Here, we report a case of a male patient in his 70s who showed recurrent ISR in the right external iliac artery. We observed the ISR lesions with not only an intravascular ultrasound (IVUS) but also an angioscopy and a biopsy to clarify the mechanism of ISR. These imaging and histopathological findings showed neointimal hyperplasia, and we performed endovascular therapy with covered stent placement to prevent neointimal formation. Not only the IVUS but also the angioscopic and histopathological findings were helpful to clarify the mechanism of ISR and to determine the treatment plan.
Topics: Humans; Male; Angioscopy; Coronary Angiography; Coronary Restenosis; Iliac Artery; Stents; Treatment Outcome; Ultrasonography, Interventional; Aged
PubMed: 37474140
DOI: 10.1136/bcr-2023-256241 -
Circulation Journal : Official Journal... Feb 2023Although favorable clinical outcomes have been demonstrated for fluoropolymer-based paclitaxel-eluting stents (FP-DES) in the treatment of femoropopliteal lesions, the...
BACKGROUND
Although favorable clinical outcomes have been demonstrated for fluoropolymer-based paclitaxel-eluting stents (FP-DES) in the treatment of femoropopliteal lesions, the vascular response after implantation has not been systematically studied through intravascular imaging.Methods and Results: We angioscopically compared FP-DES: 24 in the early phase (mean [±SD] 3±1 months), 26 in the middle phase (12±3 months), and 20 in the late phase (≥18 months) after implantation. The dominant neointimal coverage grade, heterogeneity of neointimal coverage grade, and thrombus adhesion in the stent segment were evaluated. Neointimal coverage was graded as follows: Grade 0, stent struts exposed; Grade 1, struts bulging into the lumen, although covered; Grade 2, struts embedded in the neointima, but visible; Grade 3, struts fully embedded and invisible. Dominant neointimal coverage and heterogeneity grades were significantly higher in the middle and late phases than in the early phase (all P<0.05), but did not differ significantly between the middle and late phases. The incidence of thrombus adhesion was recorded for all stents in each of the 3 different phases.
CONCLUSIONS
The middle and late phases after FP-DES implantation were associated with significantly higher dominant neointimal coverage and heterogeneity grades than the early phase. However, thrombus adhesion was observed in all phases after FP-DES implantation. Arterial healing may not be completed even in the late phase after FP-DES implantation.
Topics: Humans; Drug-Eluting Stents; Fluorocarbon Polymers; Angioscopy; Femoral Artery; Neointima; Thrombosis; Coronary Vessels; Treatment Outcome
PubMed: 36624062
DOI: 10.1253/circj.CJ-22-0635 -
Journal of Cardiology Sep 2017First-generation drug-eluting stents (DES) have reduced short-term stent failure as compared to bare-metal stents due to the inhibition of neointima hyperplasia, but... (Comparative Study)
Comparative Study Observational Study
BACKGROUND
First-generation drug-eluting stents (DES) have reduced short-term stent failure as compared to bare-metal stents due to the inhibition of neointima hyperplasia, but instead increased the risk of very-late stent failure. Although better outcomes have been reported for second-generation DES than for first-generation DES, the difference in the angioscopic findings at 1-year follow-up has not been adequately elucidated among second-generation DES.
METHODS
Consecutive 161 patients who received angioscopic examination at 1 year after implantation of second-generation DES, i.e. Nobori biolimus-eluting stents (Terumo, Tokyo, Japan) (N-BES, n=25), Xience everolimus-eluting stents (Abbot Vascular, Santa Clara, CA, USA; X-EES, n=95), or Resolute zotarolimus-eluting stents (Resolute Integrity; Medtronic, Minneapolis, MN, USA; R-ZES, n=41), in de novo native coronary lesions were analyzed.
RESULTS
Maximum neointima coverage grade (N-BES, 0.9±0.3; X-EES, 1.2±0.4; R-ZES, 1.5±0.5; p<0.001) was the highest in R-ZES and lowest in N-BES. Heterogeneity score was higher in R-ZES than in N-BES (N-BES, 0.8±0.4; X-EES, 0.9±0.4; R-ZES, 1.1±0.5; p=0.007). Maximum yellow color grade and prevalence of thrombus were not different. Multivariate analysis demonstrated that only stent type was associated with maximum neointima coverage grade; stent type and total stent length were associated with heterogeneity score; and stenting for acute coronary syndrome (ACS) and total stent length were associated with maximum yellow color grade.
CONCLUSIONS
Neointima coverage and heterogeneity were mainly determined by stent type even among second-generation DES, while yellow color was determined mainly by whether target lesion was of ACS.
Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Angioscopy; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Male; Middle Aged; Neointima; Sirolimus; Thrombosis; Treatment Outcome
PubMed: 28034576
DOI: 10.1016/j.jjcc.2016.11.012 -
Neurosurgery Dec 2023Complementary metal oxide semiconductor (CMOS) electrode arrays are a novel technology for miniaturized endoscopes; however, its use for neurointervention is yet to be...
BACKGROUND AND OBJECTIVES
Complementary metal oxide semiconductor (CMOS) electrode arrays are a novel technology for miniaturized endoscopes; however, its use for neurointervention is yet to be investigated. In this proof-of-concept study, we aimed to demonstrate the feasibility of CMOS endoscopes in a canine model by providing direct visualization of the endothelial surface, deploying stents and coils, and accessing the spinal subdural space and skull base.
METHODS
Using 3 canine models, standard guide catheters were introduced into the internal carotid and vertebral arteries through the transfemoral route using fluoroscopy. A 1.2-mm CMOS camera was delivered through the guide catheter to inspect the endothelium. Next, the camera was introduced alongside standard neuroendovascular devices including coils and stents to provide direct visualization of their deployment within the endothelium during fluoroscopy. One canine was used for skull base and extravascular visualization. A lumbar laminectomy was performed, and the camera was navigated within the spinal subdural space until the posterior circulation intracranial vasculature was visualized.
RESULTS
We successfully visualized the endothelial surface and performed several endovascular procedures such as deployment of coils and stents under direct endovascular, angioscopic vision. We also demonstrated a proof of concept for accessing the skull base and posterior cerebral vasculature using CMOS cameras through the spinal subdural space.
CONCLUSION
This proof-of-concept study demonstrates the feasibility of CMOS camera technology to directly visualize endothelium, perform common neuroendovascular procedures, and access the base of the skull in a canine model.
Topics: Animals; Dogs; Skull Base; Endovascular Procedures; Stents; Fluoroscopy; Catheters
PubMed: 37377420
DOI: 10.1227/neu.0000000000002584