-
Medicine Apr 2019The optimal anesthetic technique remains debated in patients undergoing total-hip arthroplasty (THA). The purpose of this meta-analysis was to test the efficacy of... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The optimal anesthetic technique remains debated in patients undergoing total-hip arthroplasty (THA). The purpose of this meta-analysis was to test the efficacy of general and spinal anesthesia for patients undergoing THA.
METHODS
In January 2018, we searched PubMed, Embase, Web of Science, Cochrane Database of Systematic Reviews, and the Google database. Data from randomized controlled trials (RCTs) that compared the use of general and spinal anesthesia for patients undergoing THA were retrieved. The primary outcome was to compare the total blood loss. The secondary outcomes were the occurrence of deep venous thrombosis (DVT), the occurrence of nausea, and the length of hospital stay. Software Stata 12.0 was used for meta-analysis.
RESULTS
Five RCTs with 487 THAs were finally included for meta-analysis. There was no significant difference between the general anesthesia and spinal anesthesia in terms of the total blood loss (weighted mean difference [WMD] = -20.72, 95% confidence interval [CI] -84.50 to 43.05, P = .524; I = 87.8%) and the occurrence of DVT (risk ratio (RR) = 0.85, 95% CI 0.24-3.01, P = .805; I = 70.5%). Compared with general anesthesia, spinal anesthesia was a significant reduction in the occurrence of nausea (RR = 3.04, 95% CI 1.69-5.50, P = .000; I = 0.0%) and the length of hospital stay (WMD = 1.00, 95% CI 0.59-1.41, P = .000; I = 94.7%).
CONCLUSION
Spinal anesthesia was superior than general anesthesia in terms of the occurrence of nausea and shorten the length of hospital stay. The quality and number of included studies was limited; thus, a greater number of high-quality RCTs is still needed to further identify the effects of spinal anesthesia on reducing the blood loss after THA.
Topics: Anesthesia, General; Anesthesia, Spinal; Arthroplasty, Replacement, Hip; Humans; Postoperative Complications
PubMed: 31008923
DOI: 10.1097/MD.0000000000014925 -
Chinese Journal of Traumatology =... May 2022Joint arthroplasty is an effective method for treating end-stage joint lesions and damages. Robotic arm-assisted arthroplasty, a rapidly developing technology that... (Review)
Review
Joint arthroplasty is an effective method for treating end-stage joint lesions and damages. Robotic arm-assisted arthroplasty, a rapidly developing technology that combines navigation technology, minimally invasive technology, and precise control technology of the robotic arm, can achieve accurate preoperative planning, optimal selection of implants, minimally invasive surgery, precise osteotomy, and accurate placement of the artificial joint. It has the characteristics of high accuracy and stability, and thus is more and more widely used in the field of joint surgery. In this paper, we systematically reviewed the application and clinical efficacy of robotic arm-assisted technology in hip and knee arthroplasty to provide reference for its future promotion.
Topics: Arthroplasty, Replacement, Knee; Humans; Knee Joint; Minimally Invasive Surgical Procedures; Robotic Surgical Procedures; Treatment Outcome
PubMed: 34556374
DOI: 10.1016/j.cjtee.2021.09.001 -
Acta Orthopaedica Dec 2020Background and purpose - Hip precautions limiting flexion, adduction, and internal rotation have been prescribed traditionally to minimize dislocation rates following...
Background and purpose - Hip precautions limiting flexion, adduction, and internal rotation have been prescribed traditionally to minimize dislocation rates following THA. We assessed the prevalence of hip dislocation following posterior approach total hip arthroplasty without postoperative hip precautions. Methods - A systematic review of multiple medical databases was performed using the PRISMA guidelines and checklist. All clinical outcome studies that reported dislocation rates and postoperative instructions following posterior approach, primary surgery, published within the last 6 years, were included. Results - 6,900 patients were included from 7 Level I-IV studies, with 3,517 treated with and 3,383 without precautions. There was no statistically significant difference in the rates of dislocation between groups (2.2% in restricted group vs. 2.0% in unrestricted group). All but 1 study demonstrated no statistically significant differences in patient-reported outcome scores between restricted and unrestricted groups, including those pertaining to return to function, confidence, and pain. Interpretation - The review found no impact on dislocation rates following total hip arthroplasty performed through a posterior approach, regardless of the use of hip precautions. We also found no impact of the prescription of hip precautions on patient-reported outcome scores.
Topics: Arthroplasty, Replacement, Hip; Early Ambulation; Hip Dislocation; Humans; Patient Reported Outcome Measures; Postoperative Complications
PubMed: 32718213
DOI: 10.1080/17453674.2020.1795598 -
Orthopaedics & Traumatology, Surgery &... Jun 2023Planned overlapping surgery can improve efficiency, reduce costs and help manage long waiting lists; yet, this practice has been questioned due to patient safety... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Planned overlapping surgery can improve efficiency, reduce costs and help manage long waiting lists; yet, this practice has been questioned due to patient safety concerns. A systematic review and meta-analysis were performed to answer the question: (1) are there any differences in the risk of postoperative adverse outcomes; and (2) are there any differences in length of stay or length of surgery, in elective total hip arthroplasty (THA) and total knee arthroplasty (TKA) performed either as non-overlapping surgery (NOS) or overlapping surgery (OS).
PATIENTS AND METHODS
A systematic search of literature in the databases of MEDLINE, PubMed, Embase and Cochrane from dates of inception was performed. All studies published in English were included. Risk of Bias in Non-randomised Studies-of Interventions (ROBINS-I) and the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) framework were utilised. Relative risk (RR) was used for dichotomous outcomes, while mean difference (MD) was used for continuous variables, with 95% confidence intervals. Alpha was set at 0.05.
RESULTS
A total of nine studies with 120,625 patients were included for analyses. There were no statistically significant differences for overall rates of postoperative complications, dislocations, fractures, infections, readmissions or revision surgery nor with length of stay or length of surgery (p>0.05). Patient characteristics between groups were similar (p>0.05).
DISCUSSION
There were no differences in postoperative adverse outcomes for elective orthopaedic THA and TKA performed as NOS when compared to OS. Operating schedules for OS in elective lower limb arthroplasty appear to be safe, given appropriate patient selection processes and may be a useful method to improve hospital efficiency. Informed consent and preoperative patient education should remain paramount.
LEVEL OF EVIDENCE
IV.
Topics: Humans; Arthroplasty, Replacement, Knee; Postoperative Complications; Arthroplasty, Replacement, Hip; Reoperation; Preoperative Care; Length of Stay
PubMed: 35472455
DOI: 10.1016/j.otsr.2022.103299 -
Foot and Ankle Surgery : Official... Dec 2022Total ankle arthroplasty (TAA) is increasingly used as a treatment for end-stage ankle arthropathy. However, TAA may be more sensitive to complications, failure and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Total ankle arthroplasty (TAA) is increasingly used as a treatment for end-stage ankle arthropathy. However, TAA may be more sensitive to complications, failure and subsequent re-operations compared to ankle arthrodesis. The aim of this systematic review and meta-analysis is to generate an overview of complications of TAA surgery.
METHODS
PubMed, EMBASE and the Cochrane library were searched between 2000 and 2020 to identify all papers reporting on complications in TAA surgery. Meta-analysis was conducted based on type of complication in TAA surgery. Pooled estimates of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates was rated and described according to the recommendations of the GRADE working group.
RESULTS
One hundred twenty-seven studies were included in this systematic review. All combined, they reported on 16.964 TAAs with an average follow-up of 47.99 ± 29.18 months. Complications with highest reported pooled incidence were intra-operative fracture 0.06 (95 %CI 0.04-0.08) (GRADE Very low) and impingement 0.06 (95 %CI 0.04-0.08) (GRADE low) respectively.
CONCLUSION
Reported complication incidence of TAA surgery is still high and remains a significant clinical problem that can be severely hampering long-term clinical survival of the prosthesis. The results of this systematic review and meta-analysis can help guide surgeons in informing their patient about complication risks. Implementation of more stringent patient selection criteria might contribute to diminishing TAA complication rates.
Topics: Humans; Retrospective Studies; Arthroplasty, Replacement, Ankle; Arthrodesis; Ankle Joint; Reoperation; Treatment Outcome
PubMed: 35872118
DOI: 10.1016/j.fas.2022.07.004 -
Journal of Orthopaedic Surgery and... Dec 2023Extended reality (XR), including virtual reality, augmented reality (AR), and mixed reality, has been used to help achieve accurate acetabular cup placement in total hip... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Extended reality (XR), including virtual reality, augmented reality (AR), and mixed reality, has been used to help achieve accurate acetabular cup placement in total hip arthroplasty (THA). This study aimed to compare the differences between XR-assisted and conventional THA.
METHODS
In this systematic review and meta-analysis, electronic databases including PubMed, Embase, Web of Science, Cochrane Central Register of Controlled Trials (CENTRAL), and clinicaltrials.gov were searched for studies from inception to September 10, 2023. The outcomes were accuracy of inclination and anteversion, duration of surgery, and intraoperative blood loss. Meta-analysis was performed using Review Manager 5.4 software.
RESULTS
A total of five studies with 396 patients were included in our study. The pooled results indicated AR-assisted THA had better accuracy of inclination and anteversion than conventional THA (SMD = - 0.51, 95% CI [- 0.96 to - 0.07], P = 0.02; SMD = - 0.96, 95% CI [- 1.19 to - 0.72], P < 0.00001), but duration of surgery and intraoperative blood loss were similar in the two groups.
CONCLUSION
This systematic review and meta-analysis found that AR-assisted THA had better accuracy of inclination and anteversion than conventional THA, but the duration of surgery and intraoperative blood loss were similar in the two groups. Based on the pooled results, we suggested that AR can provide more precise acetabular cup placement than conventional methods in THA.
Topics: Humans; Arthroplasty, Replacement, Hip; Augmented Reality; Blood Loss, Surgical; Acetabulum; Surgery, Computer-Assisted; Hip Prosthesis
PubMed: 38042852
DOI: 10.1186/s13018-023-04421-0 -
Journal of Shoulder and Elbow Surgery May 2022The use of reverse total shoulder arthroplasty and stemless anatomic total shoulder replacement has been increasing in the United States every year. Stemless humeral... (Review)
Review
BACKGROUND
The use of reverse total shoulder arthroplasty and stemless anatomic total shoulder replacement has been increasing in the United States every year. Stemless humeral components in reverse total shoulder arthroplasty are only approved for clinical trials in the United States with an investigational device exception with limited data.
METHODS
A systematic review on stemless reverse total shoulder arthroplasty was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. A search was conducted on November 25, 2020, using the MEDLINE/PubMed, Cochrane, and Embase databases. All articles were reviewed by 2 independent evaluators, with any conflicts or issues resolved by consensus or a final decision by the senior author. The primary outcomes extracted were complications, radiographic results, and outcome scores.
RESULTS
We evaluated 10 studies that used either the Total Evolutive Shoulder System (TESS) or Verso implant. There were 430 total patients and 437 total procedures; 266 patients in the TESS group underwent a total of 272 procedures, and 164 patients in the Verso group underwent a total of 165 procedures. The mean age at the time of surgery was 73.8 years (range, 38-93 years). The mean follow-up period ranged from 6.4 to 101.6 months per study. There was an overall trend of improved clinical outcome scores, a 0.2% humeral component loosening rate, and an 11.2% complication rate.
CONCLUSIONS
This review shows that the clinical and functional outcomes following stemless or metaphyseal reverse total shoulder arthroplasty are quite promising, especially with the low rate of humeral-sided complications. There continues to be a need for additional long-term studies and randomized clinical trials.
Topics: Arthroplasty, Replacement, Shoulder; Humans; Prosthesis Design; Shoulder Joint; Shoulder Prosthesis; Treatment Outcome
PubMed: 35051541
DOI: 10.1016/j.jse.2021.12.017 -
BMC Musculoskeletal Disorders Aug 2016The latest generation of shoulder arthroplasty includes canal-sparing respectively stemless designs that have been developed to allow restoration of the glenohumeral... (Review)
Review
BACKGROUND
The latest generation of shoulder arthroplasty includes canal-sparing respectively stemless designs that have been developed to allow restoration of the glenohumeral center of rotation independently from the shaft, and to avoid stem-related complications. The stemless prosthesis design has also recently been introduced for use in reverse arthroplasty systems.
METHODS
We systematically reviewed the literature for studies of currently available canal-sparing respectively stemless shoulder arthroplasty systems. From the identified series, we recorded the indications, outcome measures, and humeral-sided complications.
RESULTS
We identified 11 studies of canal-sparing respectively stemless anatomic shoulder arthroplasty implants, published between 2010 and 2016. These studies included 929 cases, and had a mean follow-up of 26 months (range, 6 to 72 months). The rates of humeral component-related complications ranged between 0 and 7.9 %. The studies reported only a few isolated cases of complications of the humeral component. Some arthroplasty systems are associated with radiological changes, but without any clinical relevance.
CONCLUSIONS
All of the published studies of canal-sparing respectively stemless shoulder arthroplasty reported promising clinical and radiological outcomes in short to midterm follow-up. Long-term studies are needed to demonstrate the long-term value of these kind of implants.
Topics: Arthroplasty, Replacement; Humans; Humerus; Joint Prosthesis; Osteoarthritis; Postoperative Complications; Prosthesis Design; Radiography; Shoulder Joint; Treatment Outcome
PubMed: 27577859
DOI: 10.1186/s12891-016-1235-0 -
Pain Physician May 2021The etiological diagnosis of painful primary total hip arthroplasty and its management is a complex clinical challenge for pain physicians. Extrinsic sources of pain in... (Review)
Review
BACKGROUND
The etiological diagnosis of painful primary total hip arthroplasty and its management is a complex clinical challenge for pain physicians. Extrinsic sources of pain in the hip joint might be efficiently treated by clinical pain units, although the topic remains controversial.
OBJECTIVES
To conduct a literature review and suggest an evidence-based algorithmic approach to managing painful hip arthroplasty.
STUDY DESIGN
Systematic literature review with qualitative data synthesis.
METHODS
We conducted an online search of Medline/Pubmed, Embase, Clinical Trials, and Cochrane database using the Medical Subject Heading (MeSH) and free terms on all biomedical literature published up to August 2019. Articles that described either the etiologies and management of painful primary total hip arthroplasty or the imaging techniques to specifically assess any of its causes were included. We collected the demographic data (gender, age, body mass index), main etiologies, diagnostic tests, and specific treatments applied in each study. Based on the reviewed evidence, we propose an algorithmic approach, with a special emphasis on etiologies that should be referred to pain clinics.
RESULTS
Twenty-four studies were included for the synthesis, 16 of which were observational studies and 8 of which were non-systematic literature reviews that described a wide range of etiologies of painful primary total hip arthroplasty. The results showed that 2/3 of the causes of pain were intrinsic and need to be managed by orthopedic surgeons. One third of the etiologies were extrinsic and should be referred to pain clinics once intrinsic causes have been ruled out. Among extrinsic sources of pain, the most frequent was myofascial etiology.
LIMITATIONS
A publication bias might have been present due to the inclusion of studies published only in English, Spanish, and German. The included studies also had heterogeneous methodologies.
CONCLUSIONS
The current review suggests that painful hip arthroplasty is not a rare condition in clinical practice. We systematically reviewed etiologies and various treatments published in the literature and we suggest an algorithmic approach to management based on the available evidence. This approach incorporates the evidence regarding our knowledge of the etiologies, diagnosis, and management of chronic pain after total hip arthroplasty. Systematic review registration: The protocol was registered in PROSPERO the international prospective register of systematic reviews, ID CRD42020185663.
Topics: Arthroplasty, Replacement, Hip; Hip Joint; Humans; Osteoarthritis, Hip; Pain
PubMed: 33988938
DOI: No ID Found -
The Bone & Joint Journal Jan 2017We performed a systematic review of the current literature regarding the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty. (Review)
Review
AIMS
We performed a systematic review of the current literature regarding the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty.
MATERIALS AND METHODS
We initially identified 1305 studies, and 406 were found to be duplicates. After exclusion criteria were applied, seven studies were included. Outcomes extracted included pre- and post-operative pain visual analogue scores, range of movement (ROM), strength of pinch and grip, satisfaction and patient reported outcome measures (PROMs). Clinical and radiological complications were recorded. The results are presented in three groups based on the design of the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA), pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene (MoP)).
RESULTS
Results show that pyrocarbon implants provide an 85% reduction in pain, 144% increase of pinch grip and 13° improvements in ROM for both OA and IA combined. Patients receiving MoP arthroplasties had a reduction in pinch strength. Satisfaction rates were 91% and 92% for pyrocarbon-OA and pyrocarbon-IA groups, respectively. There were nine failures in 87 joints (10.3%) over a mean follow-up of 5.5 years (1.0 to 14.3) for pyro-OA. There were 18 failures in 149 joints (12.1%) over a mean period of 6.6 years (1.0 to 16.0) for pyro-IA. Meta-analysis was not possible due to the heterogeneity of the studies and the limited presentation of data.
CONCLUSION
We would recommend prospective data collection for small joint arthroplasties of the hand consisting of PROMs that would allow clinicians to come to stronger conclusions about the impact on function of replacing the MCPJs. A national joint registry may be the best way to achieve this. Cite this article: Bone Joint J 2017;99-B:100-6.
Topics: Arthroplasty; Carbon; Hand Strength; Humans; Metacarpophalangeal Joint; Musculoskeletal Pain; Osteoarthritis; Patient Satisfaction; Prospective Studies; Prostheses and Implants; Prosthesis Failure; Range of Motion, Articular; Treatment Outcome
PubMed: 28053264
DOI: 10.1302/0301-620X.99B1.37237