Journal of Cardiovascular Development... Aug 2022The implantation of cardiac devices significantly reduces morbidity and mortality in patients with cardiac arrhythmias. Arrhythmias as well as therapy delivered by the... (Review)
Review
The implantation of cardiac devices significantly reduces morbidity and mortality in patients with cardiac arrhythmias. Arrhythmias as well as therapy delivered by the device may impact quality of life of patients concerned considerably. Therefore we aimed at conducting a systematic search and meta-analysis of trials examining the impact of the implantation of cardiac devices, namely implantable cardioverter-defibrillators (ICD), pacemakers and left-ventricular assist devices (LVAD) on quality of life. After pre-registering the trial with the PROSPERO database, we searched Medline, PsycINFO, Web of Science and the Cochrane databases for relevant publications. Study quality was assessed by two independent reviewers using standardized protocols. A total of 37 trials met our inclusion criteria. Of these, 31 trials were cohort trials while 6 trials used a randomized controlled design. We found large pre-post effect sizes for positive associations between quality of life and all types of devices. The effect sizes for LVAD, pacemaker and ICD patients were g = 1.64, g = 1.32 and g = 0.64, respectively. There was a lack of trials examining the effect of implantation on quality of life relative to control conditions. Trials assessing quality of life in patients with cardiac devices are still scarce. Yet, the existing data suggest beneficial effects of cardiac devices on quality of life. We recommend that clinical trials on cardiac devices routinely assess quality of life or other parameters of psychological well-being as a decisive study endpoint. Furthermore, improvements in psychological well-being should influence decisions about implantations of cardiac devices and be part of patient education and may impact shared decision-making.
PubMed: 36005421
DOI: 10.3390/jcdd9080257 -
Scandinavian Journal of Trauma,... Feb 2017The medical dispatcher plays an essential role as part of the first link in the Chain of Survival, by recognising the out-of-hospital cardiac arrest (OHCA) during the... (Review)
Review
BACKGROUND
The medical dispatcher plays an essential role as part of the first link in the Chain of Survival, by recognising the out-of-hospital cardiac arrest (OHCA) during the emergency call, dispatching the appropriate first responder or emergency medical services response, performing dispatcher assisted cardiopulmonary resuscitation, and referring to the nearest automated external defibrillator. The objective of this systematic review was to evaluate and compare studies reporting recognition of OHCA patients during emergency calls.
METHODS
This systematic review was reported in compliance with the PRISMA guidelines. We systematically searched MEDLINE, Embase and the Cochrane Library on 4 November 2015. Observational studies, reporting the proportion of clinically confirmed OHCAs that was recognised during the emergency call, were included. Two authors independently screened abstracts and full-text articles for inclusion. Data were extracted and the risk of bias within studies was assessed using the QUADAS-2 tool for quality assessment of diagnostic accuracy studies.
RESULTS
A total of 3,180 abstracts were screened for eligibility and 53 publications were assessed in full-text. We identified 16 studies including 6,955 patients that fulfilled the criteria for inclusion in the systematic review. The studies reported recognition of OHCA with a median sensitivity of 73.9% (range: 14.1-96.9%). The selection of study population and the definition of "recognised OHCA" (threshold for positive test) varied greatly between the studies, resulting in high risk of bias. Heterogeneity in the studies precluded meta-analysis.
CONCLUSION
Among the 16 included studies, we found a median sensitivity for OHCA recognition of 73.9% (range: 14.1-96.9%). However, great heterogeneity between study populations and in the definition of "recognised OHCA", lead to insufficient comparability of results. Uniform and transparent reporting is required to ensure comparability and development towards best practice.
Topics: Cardiopulmonary Resuscitation; Defibrillators; Emergency Medical Service Communication Systems; Emergency Medical Services; Humans; Observational Studies as Topic; Out-of-Hospital Cardiac Arrest
PubMed: 28143588
DOI: 10.1186/s13049-017-0350-8 -
International Journal of Cardiology.... Apr 2023To synthesise the available evidence of wearable cardioverter defibrillator (WCD) therapy as an add-on measure to optimal medical therapy (OMT) or as a replacement of... (Review)
Review
OBJECTIVES
To synthesise the available evidence of wearable cardioverter defibrillator (WCD) therapy as an add-on measure to optimal medical therapy (OMT) or as a replacement of hospital stay.
METHODS
An update systematic review (SR) of comparative effectiveness and safety of WCD therapy was conducted. We included randomised controlled trials (RCT), prospective comparative studies and prospective uncontrolled studies with at least 100 patients. A narrative synthesis of the evidence was conducted.
RESULTS
One RCT ( = 2348) and further eleven observational studies ( = 5345) fulfilled our inclusion criteria. In the only available RCT, the use of the WCD was not statistically associated with a clinical benefit on arrhythmic mortality in post-myocardial infarction (MI) patients with an ejection fraction of ≤35%. The compliance with WCD therapy was low in the RCT and high in observational studies, with ten observational studies reporting on a daily wear time between 20 and 23.5 h. The range of percentage of patients receiving at least one appropriate shock was 1-4.8% and the rate of first shock success was reported to be 100% in three studies. Serious adverse events (SAEs) such as inappropriate shocks occurred rarely, with between 0% and 2% of patients being inappropriately shocked within ten observational studies. In one of the observational studies, two patients (2%) were allergic to nickel developing skin rash and false alarms occurred in 58 patients (57%) in this study. Another registry study ( = 448) reported milder AEs, such as dermatitis and pressure marks, occurring in 0.9% and 0.2% of enrolled patients, respectively.
CONCLUSION
The only available RCT failed to show superiority of add-on use of WCD in post MI patients. Observational evidence shows that the compliance with WCD is good, but the evidence is afflicted with selection bias and the inclusion of diverse mixed patient populations diluting the ability to draw indication-specific conclusions on the utility of the device. More comparative data is needed to justify continuing or expanding use of WCD therapy.
PubMed: 37025482
DOI: 10.1016/j.ijcha.2023.101189 -
Resuscitation Plus Sep 2023Worldwide, bystander CPR rates are low; one effective way to increase these rates is to train schoolchildren; however, the most effective way to train them is currently... (Review)
Review
BACKGROUND
Worldwide, bystander CPR rates are low; one effective way to increase these rates is to train schoolchildren; however, the most effective way to train them is currently unknown.
METHODS
This systematic review and meta-analysis of randomized controlled trials (RCTs) and observational studies, evaluated whether CPR training for schoolchildren, using innovative teaching modalities (nonpractical, self, or peer-training) versus standard instructor-led training, resulted in higher quality CPR, self-confidence and short-term (≤3 months post-training) or long-term (>3 months post-training) retention of CPR skills.
RESULTS
From 9793 citations, 96 studies published between 1975 and 2022 (44 RCTs and 52 before/after studies) were included. There were 43,754 students, average age of 11.5 ± 0.9 (range 5.9-17.6) and 49.2% male. Only 13 RCTs compared practical vs. nonpractical training (n = 5), self- vs. instructor-led training (n = 7) or peer- vs. instructor-led training (n = 5). The observed statistically significant differences in mean depth and rate of compressions between children with hands-on practical training and those without were not clinically relevant. Regardless of training modality, compression depth was consistently suboptimal. No differences were observed in CPR skills immediately or ≤ 3 months post-training, between children who were self- or peer-trained vs. instructor-led. Due to lack of data, we were unable to evaluate the impact of these novel training modalities on student self-confidence.
CONCLUSION
Although innovative training modalities are equally effective to instructor-led training when teaching schoolchildren CPR, compression depth was frequently suboptimal. Recommendations on standardized training and evaluation methods are necessary to understand the best ways to train children.
PubMed: 37638097
DOI: 10.1016/j.resplu.2023.100439 -
International Journal of Preventive... 2019Cardiac and respiratory arrest is reversible through immediate cardiopulmonary resuscitation (CPR). However, survival after CPR is very low for various reasons. This... (Review)
Review
BACKGROUND
Cardiac and respiratory arrest is reversible through immediate cardiopulmonary resuscitation (CPR). However, survival after CPR is very low for various reasons. This systematic review study was conducted to assess the effect of palliative care on quality of life and survival after CPR.
METHODS
In the present meta-analysis and systematic review study, two researchers independently searched Google Scholar and MagIran, MedLib, IranMedex, SID, and PubMed for articles published during 1994-2016 and containing a number of relevant keywords and their Medical Subject Headings (MeSH) combinations. A total of 156 articles were initially extracted.
RESULTS
The success of initial resuscitation was reported to be much higher than the success of secondary resuscitation (survival until discharge). Moreover, the early detection of cardiac arrest, a high-quality CPR, immediate defibrillation, and effective postresuscitation care improved short- and long-term outcomes in these patients and significantly affected their quality of life after CPR. Most survivors of CPR can have a reasonable quality of life if they are given proper follow-up and persistent treatment.
CONCLUSIONS
Concerns about the low quality of life after CPR are therefore not a worthy reason to end the efforts taken for the victims of cardiac arrest. More comprehensive education programs and facilities are required for the resuscitation of patients and the provision of post-CPR intensive care.
PubMed: 31579159
DOI: 10.4103/ijpvm.IJPVM_191_18 -
Circulation. Arrhythmia and... Feb 2017Patients with heart failure and reduced ejection fraction are at increased risk of malignant ventricular arrhythmias. Implantable cardioverter-defibrillator (ICD) is... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Patients with heart failure and reduced ejection fraction are at increased risk of malignant ventricular arrhythmias. Implantable cardioverter-defibrillator (ICD) is recommended to prevent sudden cardiac death in some of these patients. Sleep-disordered breathing (SDB) is highly prevalent in this population and may impact arrhythmogenicity. We performed a systematic review and meta-analysis of prospective studies that assessed the impact of SDB on ICD therapy.
METHODS AND RESULTS
Relevant prospective studies were identified in the Ovid MEDLINE, EMBASE, and Google Scholar databases. Weighted risk ratios of the association between SDB and appropriate ICD therapies were estimated using random effects meta-analysis. Nine prospective cohort studies (n=1274) were included in this analysis. SDB was present in 52% of the participants. SDB was associated with a 55% higher risk of appropriate ICD therapies (45% versus 28%; risk ratio, 1.55; 95% confidence interval, 1.32-1.83). In a subgroup analysis based on the subtypes of SDB, the risk was higher in both central (risk ratio, 1.50; 95% confidence interval, 1.11-2.02) and obstructive (risk ratio, 1.43; 95% confidence interval, 1.01-2.03) sleep apnea.
CONCLUSIONS
SDB is associated with an increased risk of appropriate ICD therapy in patients with heart failure and reduced ejection fraction.
Topics: Death, Sudden, Cardiac; Defibrillators, Implantable; Heart Failure; Humans; Risk Factors; Sleep Apnea Syndromes; Stroke Volume
PubMed: 28213507
DOI: 10.1161/CIRCEP.116.004609 -
Wiener Klinische Wochenschrift Nov 2016The aim of this systematic review was to update scientific knowledge concerning the safety of neuromuscular electrical stimulation (NMES) to increase exercise capacity... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The aim of this systematic review was to update scientific knowledge concerning the safety of neuromuscular electrical stimulation (NMES) to increase exercise capacity and prevent cardiac cachexia in patients with implantable cardioverter defibrillators (ICDs).
METHODS
A systematic review including the electronic databases PubMed, MEDLINE, and SCOPUS was conducted for the time period from 1966 to March 31, 2016.
RESULTS
Only four articles fulfilled the inclusion criteria (three original articles/safety studies and one case report). The three (safety) studies used NMES to increase muscle strength and/or endurance capacity of the thighs. NMES did not show electromagnetic interference (EMI) with ICD function. EMI was described in a case report of 2 patients with subpectoral ICDs and application of NMES on abdominal muscles.
CONCLUSION
This review indicates that NMES may be applied in cardiac ICD patients if 1) individual risks (e. g., pacing dependency, acute heart failure, unstable angina, ventricular arrhythmic episode in the last 3 months) are excluded by performing a safety check before starting NMES treatment and 2) "passive" exercise using NMES is performed only for thighs and gluteal muscles in 3) compliant ICD patients (especially for home-based NMES) and 4) the treatment is regularly supervised by a physician and the device is examined after the first use of NMES to exclude EMI. Nevertheless, further studies including larger sample sizes are necessary to exclude any risk when NMES is used in this patient group.
Topics: Cachexia; Contraindications; Defibrillators, Implantable; Electric Injuries; Electric Stimulation Therapy; Equipment Failure; Equipment Safety; Female; Heart Failure; Humans; Male; Prevalence; Thigh
PubMed: 27457876
DOI: 10.1007/s00508-016-1045-2 -
Scientific Reports Aug 2023Risk stratification based mainly on the impairment of left ventricular ejection fraction has limited performance in patients with nonischemic dilated cardiomyopathy... (Meta-Analysis)
Meta-Analysis
Risk stratification based mainly on the impairment of left ventricular ejection fraction has limited performance in patients with nonischemic dilated cardiomyopathy (NIDCM). Evidence is rapidly growing for the impact of myocardial scar identified by late gadolinium enhancement (LGE) cardiac magnetic resonance imaging (CMR) on cardiovascular events. We aim to assess the prognostic value of LGE on long-term arrhythmic and mortality outcomes in patients with NIDCM. PubMed, Scopus, and Cochrane databases were searched from inception to January 21, 2022. Studies that included disease-specific subpopulations of NIDCM were excluded. Data were independently extracted and combined via random-effects meta-analysis using a generic inverse-variance strategy. Data from 60 studies comprising 15,217 patients were analyzed with a 3-year median follow-up. The presence of LGE was associated with major ventricular arrhythmic events (pooled OR: 3.99; 95% CI 3.08, 5.16), all-cause mortality (pooled OR: 2.14; 95% CI 1.81, 2.52), cardiovascular mortality (pooled OR 2.83; 95% CI 2.23, 3.60), and heart failure hospitalization (pooled OR: 2.53; 95% CI 1.78, 3.59). Real-world evidence suggests that the presence of LGE on CMR was a strong predictor of adverse long-term outcomes in patients with NIDCM. Scar assessment should be incorporated as a primary determinant in the patient selection criteria for primary prophylactic implantable cardioverter-defibrillator placement.
Topics: Humans; Cardiomyopathy, Dilated; Gadolinium; Cicatrix; Contrast Media; Stroke Volume; Ventricular Function, Left; Magnetic Resonance Imaging
PubMed: 37612359
DOI: 10.1038/s41598-023-41087-4 -
Health Technology Assessment... Aug 2014This assessment updates and expands on two previous technology assessments that evaluated implantable cardioverter defibrillators (ICDs) for arrhythmias and cardiac... (Review)
Review
Implantable cardioverter defibrillators for the treatment of arrhythmias and cardiac resynchronisation therapy for the treatment of heart failure: systematic review and economic evaluation.
BACKGROUND
This assessment updates and expands on two previous technology assessments that evaluated implantable cardioverter defibrillators (ICDs) for arrhythmias and cardiac resynchronisation therapy (CRT) for heart failure (HF).
OBJECTIVES
To assess the clinical effectiveness and cost-effectiveness of ICDs in addition to optimal pharmacological therapy (OPT) for people at increased risk of sudden cardiac death (SCD) as a result of ventricular arrhythmias despite receiving OPT; to assess CRT with or without a defibrillator (CRT-D or CRT-P) in addition to OPT for people with HF as a result of left ventricular systolic dysfunction (LVSD) and cardiac dyssynchrony despite receiving OPT; and to assess CRT-D in addition to OPT for people with both conditions.
DATA SOURCES
Electronic resources including MEDLINE, EMBASE and The Cochrane Library were searched from inception to November 2012. Additional studies were sought from reference lists, clinical experts and manufacturers' submissions to the National Institute for Health and Care Excellence.
REVIEW METHODS
Inclusion criteria were applied by two reviewers independently. Data extraction and quality assessment were undertaken by one reviewer and checked by a second. Data were synthesised through narrative review and meta-analyses. For the three populations above, randomised controlled trials (RCTs) comparing (1) ICD with standard therapy, (2) CRT-P or CRT-D with each other or with OPT and (3) CRT-D with OPT, CRT-P or ICD were eligible. Outcomes included mortality, adverse events and quality of life. A previously developed Markov model was adapted to estimate the cost-effectiveness of OPT, ICDs, CRT-P and CRT-D in the three populations by simulating disease progression calculated at 4-weekly cycles over a lifetime horizon.
RESULTS
A total of 4556 references were identified, of which 26 RCTs were included in the review: 13 compared ICD with medical therapy, four compared CRT-P/CRT-D with OPT and nine compared CRT-D with ICD. ICDs reduced all-cause mortality in people at increased risk of SCD, defined in trials as those with previous ventricular arrhythmias/cardiac arrest, myocardial infarction (MI) > 3 weeks previously, non-ischaemic cardiomyopathy (depending on data included) or ischaemic/non-ischaemic HF and left ventricular ejection fraction ≤ 35%. There was no benefit in people scheduled for coronary artery bypass graft. A reduction in SCD but not all-cause mortality was found in people with recent MI. Incremental cost-effectiveness ratios (ICERs) ranged from £14,231 per quality-adjusted life-year (QALY) to £29,756 per QALY for the scenarios modelled. CRT-P and CRT-D reduced mortality and HF hospitalisations, and improved other outcomes, in people with HF as a result of LVSD and cardiac dyssynchrony when compared with OPT. The rate of SCD was lower with CRT-D than with CRT-P but other outcomes were similar. CRT-P and CRT-D compared with OPT produced ICERs of £27,584 per QALY and £27,899 per QALY respectively. The ICER for CRT-D compared with CRT-P was £28,420 per QALY. In people with both conditions, CRT-D reduced the risk of all-cause mortality and HF hospitalisation, and improved other outcomes, compared with ICDs. Complications were more common with CRT-D. Initial management with OPT alone was most cost-effective (ICER £2824 per QALY compared with ICD) when health-related quality of life was kept constant over time. Costs and QALYs for CRT-D and CRT-P were similar. The ICER for CRT-D compared with ICD was £27,195 per QALY and that for CRT-D compared with OPT was £35,193 per QALY.
LIMITATIONS
Limitations of the model include the structural assumptions made about disease progression and treatment provision, the extrapolation of trial survival estimates over time and the assumptions made around parameter values when evidence was not available for specific patient groups.
CONCLUSIONS
In people at risk of SCD as a result of ventricular arrhythmias and in those with HF as a result of LVSD and cardiac dyssynchrony, the interventions modelled produced ICERs of < £30,000 per QALY gained. In people with both conditions, the ICER for CRT-D compared with ICD, but not CRT-D compared with OPT, was < £30,000 per QALY, and the costs and QALYs for CRT-D and CRT-P were similar. A RCT comparing CRT-D and CRT-P in people with HF as a result of LVSD and cardiac dyssynchrony is required, for both those with and those without an ICD indication. A RCT is also needed into the benefits of ICD in non-ischaemic cardiomyopathy in the absence of dyssynchrony.
STUDY REGISTRATION
This study is registered as PROSPERO number CRD42012002062.
FUNDING
The National Institute for Health Research Health Technology Assessment programme.
Topics: Arrhythmias, Cardiac; Cardiac Resynchronization Therapy; Cost-Benefit Analysis; Defibrillators, Implantable; Electric Countershock; Health Care Costs; Heart Failure; Humans
PubMed: 25169727
DOI: 10.3310/hta18560 -
Europace : European Pacing,... Jun 2023Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death. Anxiety, depression, and post-traumatic stress disorder (PTSD) are underappreciated... (Meta-Analysis)
Meta-Analysis
AIMS
Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death. Anxiety, depression, and post-traumatic stress disorder (PTSD) are underappreciated symptoms. We aimed to systematically synthesize prevalence estimates of mood disorders and symptom severities, pre- and post-ICD insertions. Comparisons were made with control groups, as well as within ICD patients by indication (primary vs. secondary), sex, shock status, and over time.
METHODS
Databases (Medline, PsycINFO, PubMed, and Embase) were searched without limits from inception to 31 August 2022; 4661 articles were identified, 109 (39 954 patients) of which met criteria.
RESULTS
Random-effects meta-analyses revealed clinically relevant anxiety in 22.58% (95%CI 18.26-26.91%) of ICD patients across all timepoints following insertion and depression in 15.42% (95%CI 11.90-18.94%). Post-traumatic stress disorder was seen in 12.43% (95%CI 6.90-17.96%). Rates did not vary relative to indication group. Clinically relevant anxiety and depression were more likely in ICD patients who experienced shocks [anxiety odds ratio (OR) = 3.92 (95%CI 1.67-9.19); depression OR = 1.87 (95%CI 1.34-2.59)]. Higher symptoms of anxiety were seen in females than males post-insertion [Hedges' g = 0.39 (95%CI 0.15-0.62)]. Depression symptoms decreased in the first 5 months post-insertion [Hedges' g = 0.13 (95%CI 0.03-0.23)] and anxiety symptoms after 6 months [Hedges' g = 0.07 (95%CI 0-0.14)].
CONCLUSION
Depression and anxiety are highly prevalent in ICD patients, especially in those who experience shocks. Of particular concern is the prevalence of PTSD following ICD implantation. Psychological assessment, monitoring, and therapy should be offered to ICD patients and their partners as part of routine care.
Topics: Female; Male; Humans; Defibrillators, Implantable; Anxiety; Databases, Factual; Death, Sudden, Cardiac; Odds Ratio
PubMed: 37311667
DOI: 10.1093/europace/euad130