Molecules (Basel, Switzerland) Aug 2022Hydroxyapatite (HA) is a well-known calcium phosphate ingredient comparable to human bone tissue. HA has exciting applications in many fields, especially biomedical... (Review)
Review
Hydroxyapatite (HA) is a well-known calcium phosphate ingredient comparable to human bone tissue. HA has exciting applications in many fields, especially biomedical applications, such as drug delivery, osteogenesis, and dental implants. Unfortunately, hydroxyapatite-based nanomaterials are synthesized by conventional methods using reagents that are not environmentally friendly and are expensive. Therefore, extensive efforts have been made to establish a simple, efficient, and green method to form nano-hydroxyapatite (NHA) biofunctional materials with significant biocompatibility, bioactivity, and mechanical strength. Several types of biowaste have proven to be a source of calcium in forming HA, including using chicken eggshells, fish bones, and beef bones. This systematic literature review discusses the possibility of replacing synthetic chemical reagents, synthetic pathways, and toxic capping agents with a green template to synthesize NHA. This review also shed insight on the simple green manufacture of NHA with controlled shape and size.
Topics: Animals; Bone and Bones; Cattle; Drug Delivery Systems; Durapatite; Humans; Nanostructures; Osteogenesis
PubMed: 36080349
DOI: 10.3390/molecules27175586 -
JACC. Cardiovascular Interventions Jun 2016This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS.
BACKGROUND
To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS).
METHODS
Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year.
RESULTS
A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization.
CONCLUSIONS
Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices.
Topics: Absorbable Implants; Bayes Theorem; Coronary Disease; Coronary Thrombosis; Drug-Eluting Stents; Humans; Markov Chains; Monte Carlo Method; Network Meta-Analysis; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Risk Assessment; Risk Factors; Time Factors; Treatment Outcome
PubMed: 27262860
DOI: 10.1016/j.jcin.2016.03.038 -
Biomolecules Mar 2022Cochlear implantation initiates an inflammatory cascade in which both acute insertion trauma and chronic foreign body reaction lead to intracochlear fibrosis and loss of... (Review)
Review
Cochlear implantation initiates an inflammatory cascade in which both acute insertion trauma and chronic foreign body reaction lead to intracochlear fibrosis and loss of residual hearing. Several strategies have been proposed to attenuate the local reactive process after implantation, including intracochlear drug delivery. The present study gives an overview of what is being investigated in the field of inner ear therapeutics and cochlear implant surgery. The aim is to evaluate its potential benefit in clinical practice. A systematic search was conducted in PubMed, Embase, and Cochrane Library databases identifying comparative prospective studies examining the effect of direct inner ear drug application on mechanical cochlear trauma. Both animal and human studies were considered and all studies were assessed for quality according to the validated risk of bias tools. Intracochlear administration of drugs is a feasible method to reduce the local inflammatory reaction following cochlear implantation. In animal studies, corticosteroid use had a significant effect on outcome measures including auditory brainstem response, impedance, and histological changes. This effect was, however, only durable with prolonged drug delivery. Significant differences in outcome were predominantly seen in studies where the cochlear damage was extensive. Six additional reports assessing non-steroidal agents were found. Overall, evidence of anti-inflammatory effects in humans is still scarce.
Topics: Animals; Cochlear Implantation; Cochlear Implants; Ear, Inner; Hearing; Prospective Studies
PubMed: 35454118
DOI: 10.3390/biom12040529 -
Preventive Medicine Nov 2015To systematically review the literature on contraceptive use by women with opioid and other substance use disorders in order to estimate overall contraceptive use and to... (Review)
Review
AIM
To systematically review the literature on contraceptive use by women with opioid and other substance use disorders in order to estimate overall contraceptive use and to examine method choice given the alarmingly high rate of unintended pregnancy in this population.
METHOD
Pubmed (1948-2014) and PsycINFO (1806-2014) databases were searched for peer-reviewed journal articles using a systematic search strategy. Only articles published in English and reporting contraceptive use within samples of women with opioid and other substance use disorders were eligible for inclusion.
RESULTS
Out of 580 abstracts reviewed, 105 articles were given a full-text review, and 24 studies met the inclusion criteria. The majority (51%) of women in these studies reported using opioids, with much smaller percentages reporting alcohol and cocaine use. Across studies, contraceptive prevalence ranged widely, from 6%-77%, with a median of 55%. Results from a small subset of studies (N=6) suggest that women with opioid and other substance use disorders used contraception less often than non-drug-using comparison populations (56% vs. 81%, respectively). Regarding method choice, condoms were the most prevalent method, accounting for a median of 62% of contraceptives used, while use of more effective methods, especially implants and intrauterine devices (IUDs), was far less prevalent 8%.
CONCLUSIONS
Women with opioid and other substance use disorders have an unmet need for contraception, especially for the most effective methods. Offering contraception services in conjunction with substance use treatment and promoting use of more effective methods could help meet this need and reduce unintended pregnancy in this population.
Topics: Adult; Analgesics, Opioid; Choice Behavior; Contraceptive Agents; Family Planning Services; Female; Humans; Opioid-Related Disorders; Pregnancy; Substance-Related Disorders
PubMed: 25900803
DOI: 10.1016/j.ypmed.2015.04.008 -
Journal of Dentistry Oct 2021The aim of this systematic review and meta-analysis was to state the efficacy of local administration of antibiotics in the treatment of peri-implantitis in terms of... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review and meta-analysis was to state the efficacy of local administration of antibiotics in the treatment of peri-implantitis in terms of peri-implant probing depth (PPD) and bleeding on probing (BoP) reduction.
DATA, SOURCES AND STUDY SELECTION
Electronic and manual literature searches were conducted. Screening process was done using the National Library of Medicine (MEDLINE by PubMed), Embase and the Cochrane Oral Health. Included articles were randomized controlled trials and observational studies. Weighted means were calculated. Heterogeneity was determined using Higgins (I2). Due to the encountered heterogeneity between the studies being combined, random-effects models were applied in order to analyze effect sizes. Twelve studies (365 patients and 463 implants) were included in the systematic review. After peri-implantitis treatment with local antibiotics, PPD was reduced 1.40 mm (95% confidence interval: 0.82-1.98). When local antibiotics were applied, a 0.30 mm higher reduction of PPD was obtained than in the control group (95% confidence interval: 0.07-0.53). BoP attained an odds ratio value of 1.82 (95% confidence interval: 1.09-3.04), indicating that the likehood of bleeding is almost two-fold when antibiotics are not locally administrated. Adverse effects were not found after applying local antibiotics.
CONCLUSIONS
The local antibiotic administration does reduce, without adverse effects, both peri-implant probing depths and bleeding on probing in patients affected by peri-implantitis, if compared to control groups without local antibiotic application.
CLINICAL SIGNIFICANCE
Patients with dental implants frequently suffer from peri-implantitis. Clinical features of peri-implantitis lesions include the presence of bleeding on probing and increased peri-implant probing depths. Both BoP and PPD have become reduced after local administration of antibiotics.
Topics: Anti-Bacterial Agents; Dental Implants; Humans; Peri-Implantitis
PubMed: 34455016
DOI: 10.1016/j.jdent.2021.103790 -
Advanced Drug Delivery Reviews 2020Microneedles (MNs) have been used to deliver drugs for over two decades. These platforms have been proven to increase transdermal drug delivery efficiency dramatically...
Microneedles (MNs) have been used to deliver drugs for over two decades. These platforms have been proven to increase transdermal drug delivery efficiency dramatically by penetrating restrictive tissue barriers in a minimally invasive manner. While much of the early development of MNs focused on transdermal drug delivery, this technology can be applied to a variety of other non-transdermal biomedical applications. Several variations, such as multi-layer or hollow MNs, have been developed to cater to the needs of specific applications. The heterogeneity in the design of MNs has demanded similar variety in their fabrication methods; the most common methods include micromolding and drawing lithography. Numerous materials have been explored for MN fabrication which range from biocompatible ceramics and metals to natural and synthetic biodegradable polymers. Recent advances in MN engineering have diversified MNs to include unique shapes, materials, and mechanical properties that can be tailored for organ-specific applications. In this review, we discuss the design and creation of modern MNs that aim to surpass the biological barriers of non-transdermal drug delivery in ocular, vascular, oral, and mucosal tissue.
Topics: Administration, Topical; Biological Transport; Drug Delivery Systems; Equipment Design; Humans; Microinjections; Microtechnology; Polymers; Prostheses and Implants
PubMed: 31837356
DOI: 10.1016/j.addr.2019.11.010 -
Medicine Jul 2017Controversies have been observed among network meta-analyses comparing biodegradable polymer drug-eluting stents (BP-DES) with durable polymer drug-eluting stents... (Meta-Analysis)
Meta-Analysis Review
Adverse cardiovascular events associated with biodegradable polymer drug-eluting stents and durable polymer everolimus-eluting stents: A systematic review and meta-analysis of 10 randomized controlled trials.
BACKGROUND
Controversies have been observed among network meta-analyses comparing biodegradable polymer drug-eluting stents (BP-DES) with durable polymer drug-eluting stents (DP-DES). We aimed to compare the adverse cardiovascular events associated with BP-DES and durable polymer everolimus-eluting stents (DP-EES) using a large number of patients obtained from randomized controlled trials (RCTs).
METHODS
Electronic databases were searched for randomized trials comparing BP-DES with DP-EES. Adverse cardiovascular outcomes observed between 6 months and 3 years were considered as the clinical endpoints in this analysis. Odds ratios (ORs) with 95% confidence intervals (CIs) were calculated and the pooled analyses were performed with RevMan 5.3 software. All authors had full access to the data, and they have read and agreed to the manuscript as written.
RESULTS
Ten trials involving a total number of 13,218 patients (7451 patients treated by BP-DES and 5767 patients treated by DP-EES) were included. No significant difference was observed when analyzing mortality and myocardial infarction between BP-DES and DP-EES with OR 1.08, 95% CI 0.87-1.34, P = .47 and OR 1.04, 95% CI 0.84-1.28, P = .72 respectively. Target vessel revascularization, target lesion revascularization, major adverse cardiac events, and stroke were also not significantly different with OR 1.11, 95% CI 0.92-1.33, P = .28; OR 1.11, 95% CI 0.94-1.33, P = .22; OR 1.12, 95% CI 0.99-1.27; P = .07; and OR 1.13, 95% CI 0.69-1.84; P = .62 respectively. In addition, total stent thrombosis (ST) was similarly reported between BP-DES and DP-EES with OR 0.85, 95% CI 0.59-1.21; P = .37. However, even if BP-DES were associated with a higher rate of definite ST with OR 1.69, 95% CI 0.92-3.08, P = .09 and DP-EES were associated with a higher rate of probable ST with OR 0.67, 95% CI 0.38-1.17, P = .16, these results were not statistically significant.
CONCLUSIONS
Between 6 months and 3 years, BP-DES were similar in terms of cardiovascular outcomes compared to DP-EES. However, further long-term follow-up research is recommended.
Topics: Absorbable Implants; Cardiovascular Diseases; Drug Implants; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Polymers; Randomized Controlled Trials as Topic
PubMed: 28700502
DOI: 10.1097/MD.0000000000007510 -
Pharmaceutics Feb 2024Bone defects represent an everyday challenge for clinicians who work in the fields of orthopedic surgery, maxillofacial and oral surgery, otorhinolaryngology, and dental... (Review)
Review
Bone defects represent an everyday challenge for clinicians who work in the fields of orthopedic surgery, maxillofacial and oral surgery, otorhinolaryngology, and dental implantology. Various bone substitutes have been developed and utilized, according to the needs of bone reconstructive surgery. Carbonate apatite has gained popularity in recent years, due to its excellent tissue behavior and osteoconductive potential. This systematic review aims to evaluate the role of carbonate apatite in bone reconstructive surgery and tissue engineering, analyze its advantages and limitations, and suggest further directions for research and development. The Web of Science, PubMed, and Scopus electronic databases were searched for relevant review articles, published from January 2014 to 21 July 2023. The study was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Eighteen studies were included in the present review. The biological properties and medical applications of carbonate apatite (COAp) are discussed and evaluated. The majority of articles demonstrated that COAp has excellent biocompatibility, resorbability, and osteoconductivity. Furthermore, it resembles bone tissue and causes minimal immunological reactions. Therefore, it may be successfully utilized in various medical applications, such as bone substitution, scaffolding, implant coating, drug delivery, and tissue engineering.
PubMed: 38399345
DOI: 10.3390/pharmaceutics16020291 -
The Cochrane Database of Systematic... Feb 2016Uveitis is a term used to describe a heterogeneous group of intraocular inflammatory diseases of the anterior, intermediate, and posterior uveal tract (iris, ciliary... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Uveitis is a term used to describe a heterogeneous group of intraocular inflammatory diseases of the anterior, intermediate, and posterior uveal tract (iris, ciliary body, choroid). Uveitis is the fifth most common cause of vision loss in high-income countries, accounting for 5% to 20% of legal blindness, with the highest incidence of disease in the working-age population.Corticosteroids are the mainstay of acute treatment for all anatomical subtypes of non-infectious uveitis and can be administered orally, topically with drops or ointments, by periocular (around the eye) or intravitreal (inside the eye) injection, or by surgical implantation.
OBJECTIVES
To determine the efficacy and safety of steroid implants in people with chronic non-infectious posterior uveitis, intermediate uveitis, and panuveitis.
SEARCH METHODS
We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (Issue 10, 2015), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to November 2015), EMBASE (January 1980 to November 2015), PubMed (1948 to November 2015), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to November 2015), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com) (last searched 15 April 2013), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic search for studies. We last searched the electronic databases on 6 November 2015.We also searched reference lists of included study reports, citation databases, and abstracts and clinical study presentations from professional meetings.
SELECTION CRITERIA
We included randomized controlled trials comparing either fluocinolone acetonide (FA) or dexamethasone intravitreal implants with standard-of-care therapy with at least six months of follow-up after treatment. We included studies that enrolled participants of all ages who had chronic non-infectious posterior uveitis, intermediate uveitis, or panuveitis with vision that was better than hand-motion.
DATA COLLECTION AND ANALYSIS
Two review authors independently reviewed studies for inclusion. Two review authors independently extracted data and assessed the risk of bias for each study.
MAIN RESULTS
We included data from two studies (619 eyes of 401 participants) that compared FA implants with standard-of-care therapy. Both studies used similar standard-of-care therapy that included administration of prednisolone and, if needed, immunosuppressive agents. The studies included participants from Australia, France, Germany, Israel, Italy, Portugal, Saudi Arabia, Spain, Switzerland, Turkey, the United Kingdom, and the United States. We assessed both studies at high risk of performance and detection bias.Only one study reported our primary outcome, recurrence of uveitis at any point during the study through 24 months. The evidence, judged as moderate-quality, showed that a FA implant probably prevents recurrence of uveitis compared with standard-of-care therapy (risk ratio (RR) 0.29, 95% confidence interval (CI) 0.14 to 0.59; 132 eyes). Both studies reported safety outcomes, and moderate-quality evidence showed increased risks of needing cataract surgery (RR 2.98, 95% CI 2.33 to 3.79; 371 eyes) and surgery to lower intraocular pressure (RR 7.48, 95% CI 3.94 to 14.19; 599 eyes) in the implant group compared with standard-of-care therapy through two years of follow-up. No studies compared dexamethasone implants with standard-of-care therapy.
AUTHORS' CONCLUSIONS
After considering both benefits and harms reported from two studies in which corticosteroids implants were compared with standard-of-care therapy, we are unable to conclude that the implants are superior to traditional systemic therapy for the treatment of non-infectious uveitis. These studies exhibited heterogeneity in design and outcomes that measured efficacy. Pooled findings regarding safety outcomes suggest increased risks of post-implant surgery for cataract and high intraocular pressure compared with standard-of-care therapy.
Topics: Adrenal Cortex Hormones; Adult; Chronic Disease; Drug Implants; Humans; Immunosuppressive Agents; Prednisolone; Randomized Controlled Trials as Topic; Recurrence; Standard of Care; Uveitis
PubMed: 26866343
DOI: 10.1002/14651858.CD010469.pub2 -
International Journal of Surgery... Aug 2016Currently there is no consensus on what is the optimal method for monitoring free flaps. Our meta-analysis compared the free flap success and salvage rates of... (Comparative Study)
Comparative Study Meta-Analysis Review
INTRODUCTION
Currently there is no consensus on what is the optimal method for monitoring free flaps. Our meta-analysis compared the free flap success and salvage rates of Cook-Swartz Implantable Doppler monitoring with clinical monitoring to gain insight into the relative benefit of these systems.
METHODS
Medline, Cochrane, EMBASE, and Google Scholar databases were searched until January 16, 2016. Search terms included free flap surgery, free flap microsurgery and implantable Doppler. Studies were included if they involved the comparison of Cook-Swartz Doppler and clinical assessment for monitoring free flap function. Studies using free flap monitoring as an outcome measure for drug treatment were also excluded. Sensitivity analysis using the leave-one-out approach was used to assay the reliability of the findings.
RESULTS
Initial search identified 14 studies, of which five studies were included in the meta-analysis. Cook-Swartz Doppler had significantly better rate of free flap success and salvage than clinical monitoring methods (P values ≤ 0.006). Data did not markedly changed when each study was removed in turn, showing reliability of the findings.
DISCUSSION
The Cook-Swartz Doppler as a monitoring method may result in a higher rate of free flap success and salvaging but also a greater frequency of false positives than conventional methods. Our analysis is limited by designs of included studies and by heterogeneity of clinical monitoring techniques.
CONCLUSIONS
More studies are needed to evaluate if Cook-Swartz Doppler can be used alone, or to be better used as an adjunctive technique to complement the clinical method of monitoring.
Topics: Free Tissue Flaps; Humans; Laser-Doppler Flowmetry; Microsurgery; Monitoring, Ambulatory; Postoperative Care; Prostheses and Implants; Reproducibility of Results; Salvage Therapy
PubMed: 27353849
DOI: 10.1016/j.ijsu.2016.06.034