-
Life (Basel, Switzerland) Jul 2023Nonunion (NU) is one of the most feared complications of femoral shaft fracture treatment. Femoral shaft fracture treatment is often linked with poor bone stock and... (Review)
Review
Nonunion (NU) is one of the most feared complications of femoral shaft fracture treatment. Femoral shaft fracture treatment is often linked with poor bone stock and reduced bone metabolism. In this paper, the goal is to carefully analyze the best treatment options for patients who developed nonunion after the intramedullary nailing of a femoral shaft fracture. A systematic review of the literature available in the PubMed, EMBASE and Cochran library databases was carried out, and 16 studies were included. Exclusion criteria included case reports and case series that do not have data about clinical outcomes or functional outcomes and included fewer than 10 patients. The reviewed data provide evidence for very good results about the treatment of this pathology with exchanging intramedullary nails or the implantation of a plate and screws (general healing rate of 96.3%). Moreover, the data support the utilization of autologous bone graft in order to stimulate the healing process. In conclusion, the choice between these two types of treatment must be guided by the type of pseudarthrosis that the patient presents. Additionally, bone grafting or growth factors promote bone regenerative processes, especially in patients with oligo-atrophic pseudoarthrosis.
PubMed: 37511883
DOI: 10.3390/life13071508 -
Journal of Orthopaedics 2020Forearm fractures are common injuries among children and adolescents. Traditionally, they were managed conservatively with closed reduction and cast immobilization. The... (Review)
Review
BACKGROUND
Forearm fractures are common injuries among children and adolescents. Traditionally, they were managed conservatively with closed reduction and cast immobilization. The last decade there is an increasing trend towards operative treatment. The treatment modalities available include plate and screws, flexible intramedullary nailing and external fixation devices - rarely used nowadays. The aim of this systematic review is to investigate the indications of flexible intramedullary nailing in the childhood population, to compare its results with plating and to provide detailed information considering technical pitfalls and complications that may be encountered.
MATERIALS AND METHODS
An extensive search was performed in the electronic databases (PubMed, EMBASE) from their inception up to June 2019 in order articles relevant to this review to be retrieved. The search terms used were the following: forearm fracture, both-bone fracture, pediatric, nailing, fixation. 56 articles were considered suitable for inclusion.
RESULTS
The indications for surgery are unstable and irreducible fractures, open and fractures with neurovascular compromise. As far as the fracture site is concerned, radius and ulna shaft fractures, radial head and Monteggia fractures are suitable for nailing.Although plates and nailing have comparable clinical outcomes and complication rates, flexible intramedullary nailing has the advantage of smaller incisions, less tissue disruption, shorter operative and hospital times and an ease in hardware removal.Controversy exists over the need of single or double nailing in both-bone fractures of the forearm. In addition, there is no consensus as to which is the preferred nail diameter. Yet, all the authors agree that open reduction must be considered after certain failed closed reductions in order compartment syndrome to be avoided.Flexible intramedullary nailing is not complication-free. Skin irritation, Extensor Pollicis Longus rupture, superficial radial nerve injury, delayed union or even nonunion, malunion and refractures are some of the complications that may be encountered.
DISCUSSION
Flexible nails are excellent implants combining stability and elasticity. The procedure of passing the nails across radius and ulna is relatively simple, requiring a small learning curve. Flexible intramedullary nailing is an excellent treatment modality for the treatment of forearm fractures in children and adolescents.
PubMed: 32025135
DOI: 10.1016/j.jor.2020.01.002 -
BMC Musculoskeletal Disorders Jun 2020An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures (DMCF) using plate osteosynthesis, is internal fixation by... (Meta-Analysis)
Meta-Analysis
BACKGROUND
An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures (DMCF) using plate osteosynthesis, is internal fixation by means of intramedullary fixation devices. These devices differ considerably in their specifications and characteristics and an evaluation of their clinical results is warranted. The aim of this systematic review is to generate an overview of functional outcomes and complications in the management of DMCF per available intramedullary device.
METHODS
A systematic review was conducted to identify all papers reporting functional outcomes, union rates and/or complications using an intramedullary fixation device for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until February 2020. Meta-analysis was conducted based on functional outcomes and type of complication per type of intramedullary fixation device. Pooled estimates of functional outcomes scores and incidence of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates were rated and described according to the recommendations of the GRADE working group.
RESULTS
Sixty-seven studies were included in this systematic review. The majority of studies report on the use of Titanium Elastic Nails (TEN). At 12 months follow up the Titanium Elastic Nail and Sonoma CRx report an average Constant-Murley score of 94.4 (95%CI 93-95) and 94.0 (95%CI 92-95) respectively (GRADE High). The most common reported complications after intramedullary fixation are implant-related and implant-specific. For the TEN, hardware irritation and protrusion, telescoping or migration, with a reported pooled incidence 20% (95%CI 14-26) and 12% (95%CI 8-18), are most common (GRADE Moderate). For the Rockwood/Hagie Pin, hardware irritation is identified as the most common complication with 22% (95%CI 13-35) (GRADE Low). The most common complication for the Sonoma CRx was cosmetic dissatisfaction in 6% (95%CI 2-17) of cases (GRADE Very low).
CONCLUSION
Although most studies were of low quality, good functional results and union rates irrespective of the type of device are found. However, there are clear device-related and device-specific complications for each. The results of this systematic review and meta-analysis can help guide surgeons in choosing the appropriate operative strategy, implant and informing their patient.
LEVEL OF EVIDENCE
IV.
Topics: Bone Plates; Clavicle; Fracture Fixation, Internal; Fracture Fixation, Intramedullary; Fractures, Bone; Humans; Postoperative Complications; Randomized Controlled Trials as Topic; Recurrence; Reoperation
PubMed: 32571362
DOI: 10.1186/s12891-020-03256-8 -
Journal of Orthopaedics and... Dec 2016Both long and short cephalomedullary nails (CMN) may be used to treat trochanteric femur fractures. The objective of this paper was to compare the clinical outcomes... (Review)
Review
BACKGROUND
Both long and short cephalomedullary nails (CMN) may be used to treat trochanteric femur fractures. The objective of this paper was to compare the clinical outcomes between long and short CMN in the treatment of trochanteric hip fractures.
MATERIALS AND METHODS
A literature search was performed, identifying 135 papers; 4 of which met inclusion and exclusion criteria. Papers included were those that compared cohorts of long and short nails for stable trochanteric femur fractures of level III evidence or superior. Data was pooled and analyzed, focusing on reoperation rate, secondary femoral shaft fracture rate, estimated blood loss, transfusion rate, operative time and length of stay.
RESULTS
Included in the analysis were 1276 patients, with 438 short and 838 long CMN. The average age was 82.0 years for short CMN and 79.0 years for long CMN (P = 0.0002). The average follow up was 18 months, 46 % were male, and 71 % had an ASA (American Society of Anesthesiologists score) classification ≥3. The rate of reoperation was 5.0 % and 3.8 % for short and long CMN, respectively (P = 0.31). The rate of refracture was 1.6 % and 0.95 % for short and long CMN, respectively (P = 0.41). As compared to long nails, short nails had an average blood loss of 39 mL less (P = 0.0003), an 8.8 % decrease in transfusion rate (P = 0.07), and incurred 19 min less operative time (P < 0.0001). No significant differences between short and long nails were observed for either other complications, hardware complications, non-union, or mortality.
CONCLUSIONS
For trochanteric femur fractures, short CMN have a low reoperation rate while significantly decreasing operative time and estimated blood loss with the additional benefit of being cost effective.
LEVEL OF EVIDENCE
Level 3.
Topics: Bone Nails; Femoral Fractures; Fracture Fixation, Intramedullary; Hip Fractures; Humans
PubMed: 27093971
DOI: 10.1007/s10195-016-0405-z -
International Journal of Spine Surgery Feb 2021The Patient-Reported Outcomes Measurement Information System (PROMIS) was developed to provide an easily administered patient-outcome questionnaire that was adaptable to...
BACKGROUND
The Patient-Reported Outcomes Measurement Information System (PROMIS) was developed to provide an easily administered patient-outcome questionnaire that was adaptable to a variety of medical and surgical subspecialties. Numerous authors have examined the effectiveness of PROMIS in various areas of spine surgery. Our goal was to systematically review PROMIS scores compared with legacy patient-reported outcomes measures (PROMs) in spinal surgery and spine pathology.
METHODS
A systematic search of the PubMed, EMBASE, and Cochrane databases using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines was performed, yielding 254 unique studies reporting on "PROMIS" in "spine." Each study was independently reviewed. A total of 16 studies were selected for inclusion.
RESULTS
The pooled sample size yielded a total of 4268 patients. In the cervical population, PROMIS physical function (PF; |r| = .47-.87, pain intensity (PIn; |r| = .61-.74), pain interference (PIf; |r| = .65-.88), and pain behavior (PB; |r| = .59-.74) correlated with the Neck Disability Index (NDI). PROMIS PF also strongly correlated with the modified Japanese Orthopaedic Association scale (mJOA; |r| = .61-.72). Among patients with lumbar pathology and adult spinal deformities, PROMIS PF (|r| = .53-.85), PIn (|r| = .73-.78), PIf (|r| = .59-.89), and PB (|r| = .58-.82) strongly correlated with the Oswestry Disability Index (ODI). PF (|r| = .51-.78), PIf (|r| = .60-.70), and anxiety (|r| = .73) also strongly correlated with the Scoliosis Research Society (SRS)-22 and SRS-30. When comparing measures of global health, PROMIS PF was strongly correlated with the Short Form (SF)-12 and SF-36 (|r| = .50-.85). On average, all PROMIS domains required less time to complete (49.6-56 seconds) than the ODI (176 seconds), NDI (190.3 seconds), SF-12 (214 seconds), and SF-36 physical function domains (99 seconds). The responsiveness of the PROMIS PF, PIf, and PB was comparable to that of legacy measures ODI, NDI, and SF-12.
CONCLUSIONS
The PROMIS PF, PIn, PIf, and PB demonstrated moderate to strong correlations with NDI, mJOA, ODI, SRS, and SF-12 measures in various populations of spine patients. All PROMIS domains had decreased time to completion and similar responsiveness compared with legacy measures.
LEVEL OF EVIDENCE
2.
CLINICAL RELEVANCE
These results highlight the potential of PROMIS as a valid and reliable tool to assess patient-reported outcomes in spinal surgery patients and support more widespread use of PROMIS in spine.
PubMed: 33900973
DOI: 10.14444/8024 -
Journal of Clinical Orthopaedics and... May 2021Regeneration potential of Hamstring tendons after harvest assumes significant clinical relevance as its use has become widespread today. Methods which best assess the... (Review)
Review
BACKGROUND
Regeneration potential of Hamstring tendons after harvest assumes significant clinical relevance as its use has become widespread today. Methods which best assess the regeneration, extent and type of regeneration, plus issues related to functional loss are important for the surgeon to know. This review looks at the literature to find answers to the above questions.
PURPOSE
To summarize the evidence in support of hamstring tendon regeneration, and the most appropriate modality for evaluation of regeneration. Additionally, to evaluate the regeneration in terms of complete or partial, extent and its impact on strength deficit and functional outcomes.
METHODS
We did a systematic review of literature through specified search engines and identified 30 of 285 studies to be relevant (19 prospective and 11 retrospective).
RESULTS
Evaluation of above data suggests tissue regeneration at harvest sites does occur (78.9% of semitendinosus and 42.7% of gracilis tendons), but this regeneration is variable. No established definition of regeneration exists; MRI is an adequate tool to identify regeneration, while biopsy is confirmative. USG is a cost-effective screening method and can document distal progress of regenerate. Semitendinosus and gracilis tendons regenerate at different rates and extents, and often fuse together, but there is no evidence to state that one regenerates better than the other. Proximal retraction of the muscle-tendon junction occurs, along with some atrophy, which affects function to a variable extent. Strength deficits may persist, but they may not convert to significant functional deficits.
CONCLUSION
There is variable hamstring regeneration after harvest, with poorly defined definition of "". Some changes in the muscle itself, abnormal distal insertion and absence of regeneration in some are documented, along with strength deficits. Although overall functional deficits have been reported to be minimal, a definite change in the anatomy of the medial hamstrings is a factor to be kept in consideration. More information is needed about the long-term consequences.
PubMed: 33680834
DOI: 10.1016/j.jcot.2021.02.011 -
Journal of Orthopaedics and... Apr 2024The purpose of this systematic review is to examine the outcomes, complications, and potential advantages of using anatomical interlocking intramedullary nails (IMN) in... (Meta-Analysis)
Meta-Analysis
PURPOSE
The purpose of this systematic review is to examine the outcomes, complications, and potential advantages of using anatomical interlocking intramedullary nails (IMN) in the treatment of radius and ulnar shaft diaphyseal fractures in adults.
METHODS
Medline, Embase, Web of Science, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases were searched between January 2000 and January 2023. Studies meeting criteria were observational or randomized controlled trials evaluating outcomes in IMN for adult diaphyseal forearm fractures. Standardized data extraction was performed and a quality assessment tool was used to evaluate individual study methodology. Descriptive statistics for interventions, functional outcomes, and complications were reported. Meta-analysis was performed for patient-reported outcome measures and operative time.
RESULTS
A total of 29 studies involving 1268 patients were included with 764 (60%) undergoing IMN, 21% open reduction and internal fixation (ORIF), and 9% hybrid fixation. There was no significant difference between groups in DASH and Grace-Eversmann scores. Operative time was significantly shorter in IMN compared with ORIF. The DASH scores were: 13.1 ± 6.04 for IMN, 10.17 ± 3.98 for ORIF, and 15.5 ± 0.63 in hybrids. Mean operative time was 65.3 ± 28.7 in ORIF and 50.8 ± 17.7 in IMN. Complication rates were 16.7% in the IMN group, 14.9% in ORIF, and 6.3% in hybrid constructs. There were 11 cases of extensor pollicis rupture in the IMN group. Average IMN pronation and supination were 78.3° ± 7.9° and 73° ± 5.0°, respectively. Average ORIF pronation and supination was 82.15° ± 1.9° and 79.7° ± 4.5°, respectively.
CONCLUSIONS
Similar functional outcomes and complication rates along with shorter operative times can be achieved with IMN compared with ORIF. The use of IMN is promising, however, higher quality evidence is required to assess appropriate indications, subtle differences in range of motion, implant-related complications, and cost-effectiveness. Trail Registration PROSPERO (International Prospective Register of Systematic Reviews) (ID: CRD42022362353).
Topics: Adult; Humans; Forearm; Internal Fixators; Fractures, Bone; Fracture Fixation, Intramedullary; Ulna Fractures; Forearm Injuries; Postoperative Complications
PubMed: 38615140
DOI: 10.1186/s10195-024-00761-7 -
The Cochrane Database of Systematic... Jan 2022Hip fractures are a major healthcare problem, presenting a substantial challenge and burden to patients, healthcare systems and society. The increased proportion of... (Review)
Review
BACKGROUND
Hip fractures are a major healthcare problem, presenting a substantial challenge and burden to patients, healthcare systems and society. The increased proportion of older adults in the world population means that the absolute number of hip fractures is rising rapidly across the globe. Most hip fractures are treated surgically. This Cochrane Review evaluates evidence for implants used to treat extracapsular hip fractures.
OBJECTIVES
To assess the relative effects of cephalomedullary nails versus extramedullary fixation implants for treating extracapsular hip fractures in older adults.
SEARCH METHODS
We searched CENTRAL, MEDLINE, Embase, Web of Science, the Cochrane Database of Systematic Reviews, Epistemonikos, ProQuest Dissertations & Theses, and the National Technical Information Service in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles, and conducted backward-citation searches.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) and quasi-RCTs comparing cephalomedullary nails with extramedullary implants for treating fragility extracapsular hip fractures in older adults. We excluded studies in which all or most fractures were caused by a high-energy trauma or specific pathologies other than osteoporosis.
DATA COLLECTION AND ANALYSIS
We used standard methodological procedures expected by Cochrane. We collected data for seven critical outcomes: performance of activities of daily living (ADL), delirium, functional status, health-related quality of life, mobility, mortality (reported within four months of surgery as 'early mortality'; and reported from four months onwards, with priority given to data at 12 months, as '12 months since surgery'), and unplanned return to theatre for treating a complication resulting directly or indirectly from the primary procedure (such as deep infection or non-union). We assessed the certainty of the evidence for these outcomes using GRADE. MAIN RESULTS: We included 76 studies (66 RCTs, 10 quasi-RCTs) with a total of 10,979 participants with 10,988 extracapsular hip fractures. The mean ages of participants in the studies ranged from 54 to 85 years; 72% were women. Seventeen studies included unstable trochanteric fractures; three included stable trochanteric fractures only; one included only subtrochanteric fractures; and other studies included a mix of fracture types. More than half of the studies were conducted before 2010. Owing to limitations in the quality of reporting, we could not easily judge whether care pathways in these older studies were comparable to current standards of care. We downgraded the certainty of the outcomes because of high or unclear risk of bias; imprecision (when data were available from insufficient numbers of participants or the confidence interval (CI) was wide); and inconsistency (when we noted substantial levels of statistical heterogeneity or differences between findings when outcomes were reported using other measurement tools). There is probably little or no difference between cephalomedullary nails and extramedullary implants in terms of mortality within four months of surgery (risk ratio (RR) 0.96, 95% CI 0.79 to 1.18; 30 studies, 4603 participants) and at 12 months (RR 0.99, 95% CI 0.90 to 1.08; 47 studies, 7618 participants); this evidence was assessed to be of moderate certainty. We found low-certainty evidence for differences in unplanned return to theatre but this was imprecise and included clinically relevant benefits and harms (RR 1.15, 95% CI 0.89 to 1.50; 50 studies, 8398 participants). The effect estimate for functional status at four months also included clinically relevant benefits and harms; this evidence was derived from only two small studies and was imprecise (standardised mean difference (SMD) 0.02, 95% CI -0.27 to 0.30; 188 participants; low-certainty evidence). Similarly, the estimate for delirium was imprecise (RR 1.22, 95% CI 0.67 to 2.22; 5 studies, 1310 participants; low-certainty evidence). Mobility at four months was reported using different measures (such as the number of people with independent mobility or scores on a mobility scale); findings were not consistent between these measures and we could not be certain of the evidence for this outcome. We were also uncertain of the findings for performance in ADL at four months; we did not pool the data from four studies because of substantial heterogeneity. We found no data for health-related quality of life at four months. Using a cephalomedullary nail in preference to an extramedullary device saves one superficial infection per 303 patients (RR 0.71, 95% CI 0.53 to 0.96; 35 studies, 5087 participants; moderate-certainty evidence) and leads to fewer non-unions (RR 0.55, 95% CI 0.32 to 0.96; 40 studies, 4959 participants; moderate-certainty evidence). However, the risk of intraoperative implant-related fractures was greater with cephalomedullary nails (RR 2.94, 95% CI 1.65 to 5.24; 35 studies, 4872 participants; moderate-certainty evidence), as was the risk of later fractures (RR 3.62, 95% CI 2.07 to 6.33; 46 studies, 7021 participants; moderate-certainty evidence). Cephalomedullary nails caused one additional implant-related fracture per 67 participants. We noted no evidence of a difference in other adverse events related or unrelated to the implant, fracture or both. Subgroup analyses provided no evidence of differences between the length of cephalomedullary nail used, the stability of the fracture, or between newer and older designs of cephalomedullary nail.
AUTHORS' CONCLUSIONS
Extramedullary devices, most commonly the sliding hip screw, yield very similar functional outcomes to cephalomedullary devices in the management of extracapsular fragility hip fractures. There is a reduced risk of infection and non-union with cephalomedullary nails, however there is an increased risk of implant-related fracture that is not attenuated with newer designs. Few studies considered patient-relevant outcomes such as performance of activities of daily living, health-related quality of life, mobility, or delirium. This emphasises the need to include the core outcome set for hip fracture in future RCTs.
Topics: Aged; Aged, 80 and over; Bone Nails; Female; Fracture Fixation, Internal; Fracture Fixation, Intramedullary; Hip Fractures; Humans; Middle Aged; Nails; Systematic Reviews as Topic
PubMed: 35080771
DOI: 10.1002/14651858.CD000093.pub6 -
PloS One 2014The effect of acupuncture on sensory perception has never been systematically reviewed; although, studies on acupuncture mechanisms are frequently based on the idea that... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The effect of acupuncture on sensory perception has never been systematically reviewed; although, studies on acupuncture mechanisms are frequently based on the idea that changes in sensory thresholds reflect its effect on the nervous system.
METHODS
Pubmed, EMBASE and Scopus were screened for studies investigating the effect of acupuncture on thermal or mechanical detection or pain thresholds in humans published in English or German. A meta-analysis of high quality studies was performed.
RESULTS
Out of 3007 identified articles 85 were included. Sixty five studies showed that acupuncture affects at least one sensory threshold. Most studies assessed the pressure pain threshold of which 80% reported an increase after acupuncture. Significant short- and long-term effects on the pressure pain threshold in pain patients were revealed by two meta-analyses including four and two high quality studies, respectively. In over 60% of studies, acupuncture reduced sensitivity to noxious thermal stimuli, but measuring methods might influence results. Few but consistent data indicate that acupuncture reduces pin-prick like pain but not mechanical detection. Results on thermal detection are heterogeneous. Sensory threshold changes were equally frequent reported after manual acupuncture as after electroacupuncture. Among 48 sham-controlled studies, 25 showed stronger effects on sensory thresholds through verum than through sham acupuncture, but in 9 studies significant threshold changes were also observed after sham acupuncture. Overall, there is a lack of high quality acupuncture studies applying comprehensive assessments of sensory perception.
CONCLUSIONS
Our findings indicate that acupuncture affects sensory perception. Results are most compelling for the pressure pain threshold, especially in pain conditions associated with tenderness. Sham acupuncture can also cause such effects. Future studies should incorporate comprehensive, standardized assessments of sensory profiles in order to fully characterize its effect on sensory perception and to explore the predictive value of sensory profiles for the effectiveness of acupuncture.
Topics: Acupuncture Therapy; Databases, Bibliographic; Humans; Pain Threshold
PubMed: 25502787
DOI: 10.1371/journal.pone.0113731 -
Injury Mar 2022to conduct a systematic review with consequent meta-analysis evaluating the best treatment for Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
to conduct a systematic review with consequent meta-analysis evaluating the best treatment for Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31A1-A3 trochanteric fractures when comparing the sliding hip screw (SHS) to the intramedullary nail (IMN). The outcomes used for comparison are major complications (in total, as well as nonunion and infection specifically), mortality rates, functional outcomes and patient-reported outcome measures (PROM).
MATERIALS AND METHODS
Search strings for the Cochrane Library, CINAHL, Medline and Embase databases were developed with the help of a scientific librarian. Two authors screened the studies from the search string independently using Covidence.org and data extraction was performed similarly. Quality assessment was performed using the Cochrane Risk of Bias tool for randomised trials (ROB2) for RCT studies, and Cochrane Risk of Bias in Non-Randomised Studies - of Interventions (ROBINS-I) for non-RCT studies. Meta-analyses were performed using Log Risk Ratio as the primary effect estimate.
RESULTS
Of the 2,051 studies screened by the two authors, six RCTs and six non-RCTs were included in this meta-analysis, with a total of 10,402 patients. The results indicated no significant differences in total major complications, nonunion, infection or mortality between SHS and IMN treatments for AO/OTA 31A1, 31A2 and 31A3 trochanteric fractures. Due to a lack of compatible data, we were unable to perform a meta-analysis on function scores and PROM. However, there are trends that favour IMN for 31A1 and 31A2 fractures.
CONCLUSION
No significant difference between SHS and IMN was found in the meta-analysis in any of the examined AO/OTA fracture subtypes in terms of primary and secondary outcomes. When assessing function scores and PROM, we found trends favouring IMN for 31A1 and 31A2 fractures that should be explored further.
Topics: Bone Nails; Bone Screws; Fracture Fixation, Intramedullary; Hip Fractures; Humans; Treatment Outcome
PubMed: 35027220
DOI: 10.1016/j.injury.2021.12.034