-
Dental Research Journal 2023An ever-increasing demand is seen for clear aligners and transparent vacuum-formed retainers. They are esthetic and convenient. However, the biomaterials used in these... (Review)
Review
A systematic review of biocompatibility and safety of orthodontic clear aligners and transparent vacuum-formed thermoplastic retainers: Bisphenol-A release, adverse effects, cytotoxicity, and estrogenic effects.
BACKGROUND
An ever-increasing demand is seen for clear aligners and transparent vacuum-formed retainers. They are esthetic and convenient. However, the biomaterials used in these appliances might pose biological safety and biocompatibility threats in terms of their bisphenol-A (BPA) release, cytotoxicity, adverse effects, and estrogenic effects. Due to the controversial results and the lack of any systematic reviews in this regard, we conducted this systematic review.
MATERIALS AND METHODS
Web of Science, PubMed, Cochrane, Scopus, and Google Scholar as well as references of the found articles were searched (independently by 3 researchers) up to December 22, 2021, to find studies relevant to the biocompatibility of clear aligners and thermoplastic retainers. The search keywords were a combination of the following (and more): Essix, vacuum-formed aligner, thermoplastic aligner, clear aligner, Invisalign, vacuum-formed retainer, BPA release, monomer release, cytotoxicity, estrogenicity, biocompatibility, chemical properties, and oral epithelial cell. As eligibility criteria, articles in all languages would be included as long as their text could be translated clearly using online translators or by professional translators; all types of publications (article, book, and thesis) would be included if containing relevant studies and information; they should have been on clear liners or thermoplastic retainers; and they should have been on biocompatibility, safety, cytotoxicity, or estrogenicity of clear aligners or thermoplastic retainers. There were no restrictions on the type of study (randomized clinical trials, experimental studies). Studies focusing merely on the mechanical properties of clear aligners or thermoplastic retainers (without examining their chemical properties) would be excluded. The risk of bias was assessed.
RESULTS
The risk of bias was rather low. However, the methodologies of the studies were quite different. Overall, 16 articles (1 randomized clinical trial and 15 studies) were identified. The data for BPA release were reported in four articles (1 clinical trial and 3 studies). Quantitatively speaking, the amount of released BPA reported by studies was very low, if not zero. However, the BPA level was very high in the only randomized clinical trial. Many adverse effects were linked to using clear aligners or transparent retainers, including pain and soft-tissue issues such as burning, tingling, sore tongue, lip swelling, blisters, ulceration, dry mouth, periodontal problems, and even systemic problems such as difficulty in breathing. Besides these biological adverse effects, oral dysfunctions and speech difficulties and tooth damage may be associated with clear aligners and should as well be taken into consideration.
CONCLUSION
Given the very high levels of BPA leach observed in the only clinical trial and considering other possible dangers of small traces of BPA (even at low doses) and also given the numerous adverse events linked to clear aligners or transparent retainers, it seems that safety of these appliances might be questionable and more clinical studies of biocompatibility are needed in this regard.
PubMed: 37180685
DOI: No ID Found -
Materials (Basel, Switzerland) Mar 2019The incorporation of functional monomers in dental adhesive systems promotes chemical interaction with dental substrates, resulting in higher adhesion forces when... (Review)
Review
The incorporation of functional monomers in dental adhesive systems promotes chemical interaction with dental substrates, resulting in higher adhesion forces when compared to micromechanical adhesion only. The 10-MDP monomer, whose chemical structure allows for a polar behavior which is favorable to adhesion, also promotes the protection of collagen fibers through the formation of MDP-calcium salts. This systematic review aimed to characterize the interface created by 10-MDP containing adhesive systems through an evaluation of the following parameters: Formation of nano-layered structures, capacity to produce an acid-base resistant zone, and adhesion stability. The research was conducted using PubMed, Cochrane Library, Web of Science and Embase, limited to English, Spanish, and Portuguese articles. The research was done according to the PICO strategy. The 10-MDP monomer has the capacity to produce an acid-base resistant zone on the adhesive interface, which increases the response to acid-base challenges. The adhesion established by these systems is stable over time. To have the best of these adhesive solutions, a scrubbing technique must be used to apply the adhesive system on dental substrates, in order to improve monomers infiltration and to create a stable bond. Time must be given for the solution to infiltrate, hybridize and form the MDP-Ca, improving adhesive stability.
PubMed: 30866488
DOI: 10.3390/ma12050790 -
Journal of Pharmacy & Bioallied Sciences May 2019Methyl methacrylate monomer of denture base resins was modified with several monomers to achieve better physico-mechanical properties without compromising the... (Review)
Review
BACKGROUND
Methyl methacrylate monomer of denture base resins was modified with several monomers to achieve better physico-mechanical properties without compromising the biocompatibility. However, there are no consensuses on the best strategy to achieve best modified monomer.
PURPOSE
To identify and evaluate the differences in the properties between conventional and modified monomers and to verify the influence of several variables on the properties of denture base acrylic resin.
MATERIALS AND METHODS
This study was executed by following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. In-vitro studies that investigated the properties of conventional and modified monomers were selected. Searches were carried out in the Ebscohost, PubMed, Semantic scholar and J-stage databases. The search commenced from the year 1995 and the last search was done till November 2018. A comparison was performed between modified and unmodified monomers. The analyses were carried out using fixed-effect models.
RESULTS
The meta-analysis results showed high heterogeneity in all aspects, and higher flexural strength for monomers modified with 20% methacrylic acid.
CONCLUSION
Although the articles included in this meta-analysis showed high heterogeneity and high risk of bias, the in-vitro literature seems to suggest that use of modified monomers could improve the properties of denture base resins. Other variants of monomer modifications and their tested parameters were discussed in this systematic review as well. Dimensional accuracy is an unexplored variable to be evaluated extensively in the future researches.
PubMed: 31198322
DOI: 10.4103/JPBS.JPBS_34_19 -
Systematic Reviews Aug 2021Sarcomas are a rare and heterogeneous group of tumors originating from mesenchymal or connective tissue. They represent less than 1% of all adult cancers. The etiology... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Sarcomas are a rare and heterogeneous group of tumors originating from mesenchymal or connective tissue. They represent less than 1% of all adult cancers. The etiology and epidemiology of sarcomas remain understudied and poorly understood. The main objective of our study was to systematically assess the association between various occupational exposures and risk of sarcomas.
METHODS
We performed a systematic literature search using the PubMed, Scopus, EMBASE and Cochrane databases to identify relevant cohort and case-control studies. A meta-analysis method was applied on the incidence and mortality outcomes where the estimate with 95% confidence interval (CI) was obtained.
RESULTS
We included a total of 50 publications in our systematic review and 35 in meta-analysis. For exposures to phenoxy herbicides and chlorophenols, the pooled odds ratio (OR) for sarcoma was 1.85 (95% CI: 1.22, 2.82), based on 16 studies with 2254 participants, while the pooled standardized mortality ratio was 40.93 (95% CI 2.19, 765.90), based on 4 cohort studies with 59,289 participants. For exposure to vinyl chloride monomers the pooled risk ratios for angiosarcoma of the liver and other STS were 19.23 (95% CI 2.03, 182.46) and 2.23 (95 CI 1.55, 3.22) respectively based on 3 cohort studies with 12,816 participants. Exposure to dioxins was associated with an increased STS mortality; the pooled standardized mortality ratio was 2.56 (95% CI 1.60, 4.10) based on 4 cohort studies with 30,797 participants. Finally, woodworking occupation was associated with an increased risk of STS with the pooled OR of 2.16 (95% CI 1.39, 3.36).
CONCLUSIONS
Our findings suggest a positive association between higher exposure to dioxins and increased mortality from STS, between cumulative exposure to vinyl chloride monomers and increased mortality from angiosarcoma of the liver and STS, and between woodworking occupation and STS incidence. These findings were all statistically significant.
Topics: Adult; Cohort Studies; Humans; Incidence; Occupational Diseases; Occupational Exposure; Sarcoma
PubMed: 34389054
DOI: 10.1186/s13643-021-01769-4 -
American Journal of Industrial Medicine Nov 2017Styrene is a chemical used in the manufacture of plastic-based products worldwide. We systematically reviewed eligible studies of occupational styrene-induced... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Styrene is a chemical used in the manufacture of plastic-based products worldwide. We systematically reviewed eligible studies of occupational styrene-induced dyschromatopsia, qualitatively synthesizing their findings and estimating the exposure effect through meta-analysis.
METHODS
PubMed, EMBASE, and Web of Science databases were queried for eligible studies. Using a random effects model, we compared measures of dyschromatopsia between exposed and non-exposed workers to calculate the standardized mean difference (Hedges'g). We also assessed between-study heterogeneity and publication bias.
RESULTS
Styrene-exposed subjects demonstrated poorer color vision than did the non-exposed (Hedges' g = 0.56; 95%CI: 0.37, 0.76; P < 0.0001). A non-significant Cochran's Q test result (Q = 23.2; P = 0.171) and an I of 32.2% (0.0%, 69.9%) indicated low-to-moderate between-study heterogeneity. Funnel plot and trim-and-fill analyses suggested publication bias.
CONCLUSIONS
This review confirms the hypothesis of occupational styrene-induced dyschromatopsia, suggesting a modest effect size with mild heterogeneity between studies.
Topics: Color Vision Defects; Humans; Occupational Diseases; Occupational Exposure; Styrene
PubMed: 28836685
DOI: 10.1002/ajim.22766 -
Biomaterial Investigations in Dentistry 2023Flowable bulk-fill resin-based composites (BF-RBCs) represent a new and interesting alternative for the bulk-fill restorative techniques in the posterior region.... (Review)
Review
Flowable bulk-fill resin-based composites (BF-RBCs) represent a new and interesting alternative for the bulk-fill restorative techniques in the posterior region. However, they comprise a heterogeneous group of materials, with important differences in composition and design. Therefore, the aim of the present systematic review was to compare the main properties of flowable BF-RBCs, including their composition, degree of monomer conversion (DC), polymerization shrinkage and shrinkage stress, as well as flexural strength. The search was conducted following PRISMA guidelines in the Medline (PubMed), Scopus and Web of Science databases. articles reporting on the DC, polymerization shrinkage/shrinkage stress, and flexural strength of flowable BF-RBCs strength were included. The QUIN risk-of-bias (RoB) tool was used for assessing the study quality. From initially 684 found articles, 53 were included. Values for DC ranged between 19.41 and 93.71%, whereas polymerization shrinkage varied between 1.26 and 10.45%. Polymerization shrinkage stresses reported by most studies ranged between 2 and 3 MPa. Flexural strength was above 80 MPa for most materials. A moderate RoB was observed in most studies. Flowable BF-RBCs meet the requirements to be indicated for bulk fill restoration technique in the posterior region. However, important variations among composition and properties hinder extrapolation of the results to materials different from those reported here. Clinical studies are urgently required to assess their performance under a real working scenario.
PubMed: 37138762
DOI: 10.1080/26415275.2023.2175685 -
Arthroplasty (London, England) Feb 2021Methyl methacrylate (MMA) is commonly used in the fields of dentistry and orthopaedic surgery. However, there remain concerns for the occupational hazards of MMA,... (Review)
Review
INTRODUCTION
Methyl methacrylate (MMA) is commonly used in the fields of dentistry and orthopaedic surgery. However, there remain concerns for the occupational hazards of MMA, particularly during pregnancy and breastfeeding.
METHODS
We performed a systematic review of studies on effects that MMA may have in pregnancy in the context of exposure during orthopaedic surgery and dentistry. Review articles, studies lacking statistical data, single case reports and other evidence level V studies were excluded.
RESULTS
Nine studies were included. One basic science study demonstrated an increase in neuronal cell lysis and shrunken cell bodies when neocortical neurons were exposed to MMA monomer. Three animal studies exposed pregnant rodents to MMA via intraperitoneal injection or inhalation. Exposed fetuses in two studies had an increase in gross abnormalities such as hemangiomas, while there was no increase in teratologic effects in the third study. In dental workers exposed to MMA, two retrospective cohort studies did not find a statistically significant increase in birth defects or miscarriage. After exposure to MMA during total joint arthroplasty, two studies found that MMA levels were undetectable in the mothers' serum or breast milk. One study measuring the airborne levels of MMA during simulated joint arthroplasty found that concentrations never exceeded 1% of the recommended limit set forth by the Occupational Safety and Health Administration (OSHA).
CONCLUSIONS
Potential teratologic effects of MMA cannot be excluded by existing evidence. However, the typical MMA exposure levels for dental and orthopaedic personnel appear to be substantially less than currently proposed exposure limits.
PubMed: 35236460
DOI: 10.1186/s42836-020-00059-z -
Maedica Jun 2020The aim of this study was to find the most effective surface preparation methods to enhance the bond strength between the composite resin and surface remaining from...
The Effect of Mechanical and Chemical Surface Preparation Methods on the Bond Strength in Repairing the Surface of Metal-Ceramic Crowns with Composite Resin: a Systematic Review and Meta-Analysis.
The aim of this study was to find the most effective surface preparation methods to enhance the bond strength between the composite resin and surface remaining from ceramic fracture. In this systematic review and meta-analysis, 39 studies were examined. The information related to the studies was extracted and categorized based on the type of the substrate material and applying or not applying thermal cycles (p<0.05). In the meta-analysis of substrate metal-ceramic samples without aging, application of air abrasion resulted in a significant increase of the bond strength to composite resin when using chemical compounds of the group without the mentioned functional monomers. Application of mechanical and chemical surface preparation methods can result in enhanced bond strength of the composite to the substrate material, which depends on the type of substrate material.
PubMed: 32952686
DOI: 10.26574/maedica.2020.15.2.206 -
Phytomedicine : International Journal... Jul 2024Respiratory diseases pose a grave threat to human life. Therefore, understanding their pathogenesis and therapeutic strategy is important. Ferroptosis is a novel type of... (Review)
Review
BACKGROUND
Respiratory diseases pose a grave threat to human life. Therefore, understanding their pathogenesis and therapeutic strategy is important. Ferroptosis is a novel type of iron-dependent programmed cell death, distinct from apoptosis, necroptosis, and autophagy, characterised by iron, reactive oxygen species, and lipid peroxide accumulation, as well as glutathione (GSH) depletion and GSH peroxidase 4 (GPX4) inactivation. A close association between ferroptosis and the onset and progression of respiratory diseases, including chronic obstructive pulmonary disease, acute lung injury, bronchial asthma, pulmonary fibrosis, and lung cancer, has been reported. Recent studies have shown that traditional Chinese medicine (TCM) compounds exhibit unique advantages in the treatment of respiratory diseases owing to their natural properties and potential efficacy. These compounds can effectively regulate ferroptosis by modulating several key signalling pathways such as system Xc -GSH-GPX4, NCOA4-mediated ferritinophagy, Nrf2-GPX4, and Nrf2/HO-1, thus playing a positive role in improving respiratory diseases.
PURPOSE
This comprehensive review systematically outlines the regulatory role of ferroptosis in the onset and progression of respiratory diseases and provides evidence for treating respiratory diseases by targeting ferroptosis with TCM compounds. These insights aim to offer potential remedies for the clinical prevention and treatment of respiratory diseases.
STUDY DESIGN AND METHODS
We searched scientific databases PubMed, Web of Science, Scopus, and CNKI using keywords such as "ferroptosis","respiratory diseases","chronic obstructive pulmonary disease","bronchial asthma","acute lung injury","pulmonary fibrosis","lung cancer","traditional Chinese medicine","traditional Chinese medicine compound","monomer", and "natural product" to retrieve studies on the therapeutic potential of TCM compounds in ameliorating respiratory diseases by targeting ferroptosis. The retrieved data followed PRISMA criteria (preferred reporting items for systematic review).
RESULTS
TCM compounds possess unique advantages in treating respiratory diseases, stemming from their natural origins and proven clinical effectiveness. TCM compounds can exert therapeutic effects on respiratory diseases by regulating ferroptosis, which mainly involves modulation of pathways such as system Xc -GSH-GPX4,NCOA4-mediated ferritinophagy, Nrf2-GPX4, and Nrf2/HO-1.
CONCLUSION
TCM compounds have demonstrated promising potential in improving respiratory diseases through the regulation of ferroptosis. The identification of specific TCM-related inducers and inhibitors of ferroptosis holds great significance in developing more effective strategies. However, current research remains confined to animal and cellular studies, emphasizing the imperative for further verifications through high-quality clinical data.
Topics: Ferroptosis; Humans; Drugs, Chinese Herbal; Animals; Signal Transduction; Acute Lung Injury; Medicine, Chinese Traditional; Respiratory Tract Diseases; Reactive Oxygen Species; Pulmonary Fibrosis
PubMed: 38824825
DOI: 10.1016/j.phymed.2024.155738 -
Methods and Protocols Jan 2022The most used types of retention of implant-supported prostheses are screw-retained or cement-retained restorations. The advantages and disadvantages of both have been... (Review)
Review
BACKGROUND
The most used types of retention of implant-supported prostheses are screw-retained or cement-retained restorations. The advantages and disadvantages of both have been identified by various authors over the years. However, cement-retained implant crowns and fixed partial dentures are among the most used types of restorations in implant prostheses, due to their aesthetic and clinical advantages. When cemented prostheses are made on implants, the problem of cement residues is important and often associated with biological implant pathologies. The objective of this research was to establish to what extent the techniques to reduce excess cement really affect the volume of cement residues.
MATERIALS AND METHODS
This review was written following the PRISMA statement; a detailed search was carried out in three different electronic databases-PubMed, Scopus, and Cochrane Library. The inclusion criteria were prospective clinical studies, with at least 10 participants per group, and with at least 6 months of the follow-up period.
RESULTS
There have been many proposals for techniques supposed to reduce the amount of excess cement in the peri-implant sulcus and on the prosthetic components, but of these, which are exceptional in their in vitro capabilities, very few have been clinically validated, and this represents the real limitation and a great lack of knowledge regarding this topic. Three articles met the inclusion criteria, which were analyzed and compared, to obtain the information necessary for the purposes of the systematic review.
DISCUSSION
Extraoral cementation can reduce the excess cement, which, after a normal excess removal procedure, is, nevertheless, of such size that it does not affect the possibility of peri-implant pathologies developing. All these studies concluded that a small amount of cement residue is found in the gingival sulcus, and using eugenol-free oxide cements, the residues were only deposited on the metal surfaces, with a better peri-implant tissues health.
CONCLUSION
Despite the limitations of this study, it was possible to carefully analyze these characteristics and obtain valuable suggestions for daily clinical practice. Resinous cements are considered, due to the free monomers present in them, toxic for the soft tissues. The provisional zinc-oxide cements, also eugenol-free, represent the ideal choice. The different grades of retentive forces provided by these cements do not seem to have clinical effects on the decementation of restorations.
PubMed: 35076562
DOI: 10.3390/mps5010009