Journal of Biomedical Informatics May 2020This review aims to: 1) evaluate the quality of model reporting, 2) provide an overview of methodology for developing and validating Early Warning Score Systems (EWSs)... (Review)
Review
OBJECTIVES
This review aims to: 1) evaluate the quality of model reporting, 2) provide an overview of methodology for developing and validating Early Warning Score Systems (EWSs) for adult patients in acute care settings, and 3) highlight the strengths and limitations of the methodologies, as well as identify future directions for EWS derivation and validation studies.
METHODOLOGY
A systematic search was conducted in PubMed, Cochrane Library, and CINAHL. Only peer reviewed articles and clinical guidelines regarding developing and validating EWSs for adult patients in acute care settings were included. 615 articles were extracted and reviewed by five of the authors. Selected studies were evaluated based on the Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) checklist. The studies were analyzed according to their study design, predictor selection, outcome measurement, methodology of modeling, and validation strategy.
RESULTS
A total of 29 articles were included in the final analysis. Twenty-six articles reported on the development and validation of a new EWS, while three reported on validation and model modification. Only eight studies met more than 75% of the items in the TRIPOD checklist. Three major techniques were utilized among the studies to inform their predictive algorithms: 1) clinical-consensus models (n = 6), 2) regression models (n = 15), and 3) tree models (n = 5). The number of predictors included in the EWSs varied from 3 to 72 with a median of seven. Twenty-eight models included vital signs, while 11 included lab data. Pulse oximetry, mental status, and other variables extracted from electronic health records (EHRs) were among other frequently used predictors. In-hospital mortality, unplanned transfer to the intensive care unit (ICU), and cardiac arrest were commonly used clinical outcomes. Twenty-eight studies conducted a form of model validation either within the study or against other widely-used EWSs. Only three studies validated their model using an external database separate from the derived database.
CONCLUSION
This literature review demonstrates that the characteristics of the cohort, predictors, and outcome selection, as well as the metrics for model validation, vary greatly across EWS studies. There is no consensus on the optimal strategy for developing such algorithms since data-driven models with acceptable predictive accuracy are often site-specific. A standardized checklist for clinical prediction model reporting exists, but few studies have included reporting aligned with it in their publications. Data-driven models are subjected to biases in the use of EHR data, thus it is particularly important to provide detailed study protocols and acknowledge, leverage, or reduce potential biases of the data used for EWS development to improve transparency and generalizability.
Topics: Adult; Early Warning Score; Humans; Intensive Care Units; Models, Statistical; Prognosis; Vital Signs
PubMed: 32278089
DOI: 10.1016/j.jbi.2020.103410 -
JMIR MHealth and UHealth Jan 2022Wearable devices hold great promise, particularly for data generation for cutting-edge health research, and their demand has risen substantially in recent years.... (Review)
Review
BACKGROUND
Wearable devices hold great promise, particularly for data generation for cutting-edge health research, and their demand has risen substantially in recent years. However, there is a shortage of aggregated insights into how wearables have been used in health research.
OBJECTIVE
In this review, we aim to broadly overview and categorize the current research conducted with affordable wearable devices for health research.
METHODS
We performed a scoping review to understand the use of affordable, consumer-grade wearables for health research from a population health perspective using the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) framework. A total of 7499 articles were found in 4 medical databases (PubMed, Ovid, Web of Science, and CINAHL). Studies were eligible if they used noninvasive wearables: worn on the wrist, arm, hip, and chest; measured vital signs; and analyzed the collected data quantitatively. We excluded studies that did not use wearables for outcome assessment and prototype studies, devices that cost >€500 (US $570), or obtrusive smart clothing.
RESULTS
We included 179 studies using 189 wearable devices covering 10,835,733 participants. Most studies were observational (128/179, 71.5%), conducted in 2020 (56/179, 31.3%) and in North America (94/179, 52.5%), and 93% (10,104,217/10,835,733) of the participants were part of global health studies. The most popular wearables were fitness trackers (86/189, 45.5%) and accelerometer wearables, which primarily measure movement (49/189, 25.9%). Typical measurements included steps (95/179, 53.1%), heart rate (HR; 55/179, 30.7%), and sleep duration (51/179, 28.5%). Other devices measured blood pressure (3/179, 1.7%), skin temperature (3/179, 1.7%), oximetry (3/179, 1.7%), or respiratory rate (2/179, 1.1%). The wearables were mostly worn on the wrist (138/189, 73%) and cost <€200 (US $228; 120/189, 63.5%). The aims and approaches of all 179 studies revealed six prominent uses for wearables, comprising correlations-wearable and other physiological data (40/179, 22.3%), method evaluations (with subgroups; 40/179, 22.3%), population-based research (31/179, 17.3%), experimental outcome assessment (30/179, 16.8%), prognostic forecasting (28/179, 15.6%), and explorative analysis of big data sets (10/179, 5.6%). The most frequent strengths of affordable wearables were validation, accuracy, and clinical certification (104/179, 58.1%).
CONCLUSIONS
Wearables showed an increasingly diverse field of application such as COVID-19 prediction, fertility tracking, heat-related illness, drug effects, and psychological interventions; they also included underrepresented populations, such as individuals with rare diseases. There is a lack of research on wearable devices in low-resource contexts. Fueled by the COVID-19 pandemic, we see a shift toward more large-sized, web-based studies where wearables increased insights into the developing pandemic, including forecasting models and the effects of the pandemic. Some studies have indicated that big data extracted from wearables may potentially transform the understanding of population health dynamics and the ability to forecast health trends.
Topics: COVID-19; Fitness Trackers; Humans; Pandemics; SARS-CoV-2; Wearable Electronic Devices
PubMed: 35076409
DOI: 10.2196/34384 -
The Cochrane Database of Systematic... Mar 2018Health outcomes are improved when newborn babies with critical congenital heart defects (CCHDs) are detected before acute cardiovascular collapse. The main screening... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Health outcomes are improved when newborn babies with critical congenital heart defects (CCHDs) are detected before acute cardiovascular collapse. The main screening tests used to identify these babies include prenatal ultrasonography and postnatal clinical examination; however, even though both of these methods are available, a significant proportion of babies are still missed. Routine pulse oximetry has been reported as an additional screening test that can potentially improve detection of CCHD.
OBJECTIVES
• To determine the diagnostic accuracy of pulse oximetry as a screening method for detection of CCHD in asymptomatic newborn infants• To assess potential sources of heterogeneity, including:○ characteristics of the population: inclusion or exclusion of antenatally detected congenital heart defects;○ timing of testing: < 24 hours versus ≥ 24 hours after birth;○ site of testing: right hand and foot (pre-ductal and post-ductal) versus foot only (post-ductal);○ oxygen saturation: functional versus fractional;○ study design: retrospective versus prospective design, consecutive versus non-consecutive series; and○ risk of bias for the "flow and timing" domain of QUADAS-2.
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 2) in the Cochrane Library and the following databases: MEDLINE, Embase, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Health Services Research Projects in Progress (HSRProj), up to March 2017. We searched the reference lists of all included articles and relevant systematic reviews to identify additional studies not found through the electronic search. We applied no language restrictions.
SELECTION CRITERIA
We selected studies that met predefined criteria for design, population, tests, and outcomes. We included cross-sectional and cohort studies assessing the diagnostic accuracy of pulse oximetry screening for diagnosis of CCHD in term and late preterm asymptomatic newborn infants. We considered all protocols of pulse oximetry screening (eg, different saturation thresholds to define abnormality, post-ductal only or pre-ductal and post-ductal measurements, test timing less than or greater than 24 hours). Reference standards were diagnostic echocardiography (echocardiogram) and clinical follow-up, including postmortem findings, mortality, and congenital anomaly databases.
DATA COLLECTION AND ANALYSIS
We extracted accuracy data for the threshold used in primary studies. We explored between-study variability and correlation between indices visually through use of forest and receiver operating characteristic (ROC) plots. We assessed risk of bias in included studies using the QUADAS-2 tool. We used the bivariate model to calculate random-effects pooled sensitivity and specificity values. We investigated sources of heterogeneity using subgroup analyses and meta-regression.
MAIN RESULTS
Twenty-one studies met our inclusion criteria (N = 457,202 participants). Nineteen studies provided data for the primary analysis (oxygen saturation threshold < 95% or ≤ 95%; N = 436,758 participants). The overall sensitivity of pulse oximetry for detection of CCHD was 76.3% (95% confidence interval [CI] 69.5 to 82.0) (low certainty of the evidence). Specificity was 99.9% (95% CI 99.7 to 99.9), with a false-positive rate of 0.14% (95% CI 0.07 to 0.22) (high certainty of the evidence). Summary positive and negative likelihood ratios were 535.6 (95% CI 280.3 to 1023.4) and 0.24 (95% CI 0.18 to 0.31), respectively. These results showed that out of 10,000 apparently healthy late preterm or full-term newborn infants, six will have CCHD (median prevalence in our review). Screening by pulse oximetry will detect five of these infants as having CCHD and will miss one case. In addition, screening by pulse oximetry will falsely identify another 14 infants out of the 10,000 as having suspected CCHD when they do not have it.The false-positive rate for detection of CCHD was lower when newborn pulse oximetry was performed longer than 24 hours after birth than when it was performed within 24 hours (0.06%, 95% CI 0.03 to 0.13, vs 0.42%, 95% CI 0.20 to 0.89; P = 0.027).Forest and ROC plots showed greater variability in estimated sensitivity than specificity across studies. We explored heterogeneity by conducting subgroup analyses and meta-regression of inclusion or exclusion of antenatally detected congenital heart defects, timing of testing, and risk of bias for the "flow and timing" domain of QUADAS-2, and we did not find an explanation for the heterogeneity in sensitivity.
AUTHORS' CONCLUSIONS
Pulse oximetry is a highly specific and moderately sensitive test for detection of CCHD with very low false-positive rates. Current evidence supports the introduction of routine screening for CCHD in asymptomatic newborns before discharge from the well-baby nursery.
Topics: Asymptomatic Diseases; Data Accuracy; False Positive Reactions; Heart Defects, Congenital; Humans; Infant, Newborn; Oximetry; Sensitivity and Specificity
PubMed: 29494750
DOI: 10.1002/14651858.CD011912.pub2 -
International Journal of Environmental... Aug 2022The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal... (Meta-Analysis)
Meta-Analysis Review
The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
Topics: Dentition, Permanent; Hot Temperature; Humans; Oximetry; Reproducibility of Results; Sensitivity and Specificity
PubMed: 35954958
DOI: 10.3390/ijerph19159599 -
BMC Medicine Aug 2022During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We... (Meta-Analysis)
Meta-Analysis
BACKGROUND
During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We systematically reviewed the effects of skin pigmentation on the accuracy of oxygen saturation measurement by pulse oximetry (SpO) compared with the gold standard SaO measured by CO-oximetry.
METHODS
We searched Ovid MEDLINE, Ovid Embase, EBSCO CINAHL, ClinicalTrials.gov, and WHO International Clinical Trials Registry Platform (up to December 2021) for studies with SpO-SaO comparisons and measuring the impact of skin pigmentation or ethnicity on pulse oximetry accuracy. We performed meta-analyses for mean bias (the primary outcome in this review) and its standard deviations (SDs) across studies included for each subgroup of skin pigmentation and ethnicity and used these pooled mean biases and SDs to calculate accuracy root-mean-square (A) and 95% limits of agreement. The review was registered with the Open Science Framework ( https://osf.io/gm7ty ).
RESULTS
We included 32 studies (6505 participants): 15 measured skin pigmentation and 22 referred to ethnicity. Compared with standard SaO measurement, pulse oximetry probably overestimates oxygen saturation in people with the high level of skin pigmentation (pooled mean bias 1.11%; 95% confidence interval 0.29 to 1.93%) and people described as Black/African American (1.52%; 0.95 to 2.09%) (moderate- and low-certainty evidence). The bias of pulse oximetry measurements for people with other levels of skin pigmentation or those from other ethnic groups is either more uncertain or suggests no overestimation. Whilst the extent of mean bias is small or negligible for all subgroups evaluated, the associated imprecision is unacceptably large (pooled SDs > 1%). When the extent of measurement bias and precision is considered jointly, pulse oximetry measurements for all the subgroups appear acceptably accurate (with A < 4%).
CONCLUSIONS
Pulse oximetry may overestimate oxygen saturation in people with high levels of skin pigmentation and people whose ethnicity is reported as Black/African American, compared with SaO. The extent of overestimation may be small in hospital settings but unknown in community settings. REVIEW PROTOCOL REGISTRATION: https://osf.io/gm7ty.
Topics: COVID-19; Humans; Oximetry; Oxygen; Oxygen Saturation; Pandemics; Skin Pigmentation
PubMed: 35971142
DOI: 10.1186/s12916-022-02452-8 -
Journal of Biomedical Optics Aug 2022Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their... (Review)
Review
SIGNIFICANCE
Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their depth of imaging, spatiotemporal resolution, sensitivity, accuracy, complexity, physical size, and cost. The wide variation in available instrumentation can make it challenging for end users to select the appropriate tools for their application and to understand the relative limitations of different methods.
AIM
We aim to provide a systematic overview of the field of hemoglobin imaging and sensing.
APPROACH
We reviewed the sensing and imaging methods used to analyze hemoglobin oxygenation, including pulse oximetry, spectral reflectance imaging, diffuse optical imaging, spectroscopic optical coherence tomography, photoacoustic imaging, and diffuse correlation spectroscopy.
RESULTS
We compared and contrasted the ability of different methods to determine hemoglobin biomarkers such as oxygenation while considering factors that influence their practical application.
CONCLUSIONS
We highlight key limitations in the current state-of-the-art and make suggestions for routes to advance the clinical use and interpretation of hemoglobin oxygenation information.
Topics: Hemoglobins; Oximetry; Spectrum Analysis; Tomography, Optical Coherence
PubMed: 35922891
DOI: 10.1117/1.JBO.27.8.080901 -
Sensors (Basel, Switzerland) Apr 2022Nowadays, pulse oximetry has become the standard in primary and intensive care units, especially as a triage tool during the current COVID-19 pandemic. Hence, a deeper... (Review)
Review
Nowadays, pulse oximetry has become the standard in primary and intensive care units, especially as a triage tool during the current COVID-19 pandemic. Hence, a deeper understanding of the measurement errors that can affect precise readings is a key element in clinical decision-making. Several factors may influence the accuracy of pulse oximetry, such as skin color, body temperature, altitude, or patient movement. The skin pigmentation effect on pulse oximetry accuracy has long been studied reporting some contradictory conclusions. Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions. This review aims to study the literature that assesses the influence of skin pigmentation on the accuracy of these devices. We employed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to conduct a systematic review retrospectively since February 2022 using WOS, PubMed, and Scopus databases. We found 99 unique references, of which only 41 satisfied the established inclusion criteria. A bibliometric and scientometrics approach was performed to examine the outcomes of an exhaustive survey of the thematic content and trending topics.
Topics: Bibliometrics; COVID-19; Humans; Oximetry; Oxygen; Pandemics; Retrospective Studies; Skin Pigmentation
PubMed: 35591092
DOI: 10.3390/s22093402 -
Annals of Cardiac Anaesthesia 2022High prevalence of cerebral desaturation is associated with postoperative neurological complications in cardiac surgery. However, the evidence use of cerebral oximetry... (Meta-Analysis)
Meta-Analysis Review
High prevalence of cerebral desaturation is associated with postoperative neurological complications in cardiac surgery. However, the evidence use of cerebral oximetry by correcting cerebral desaturation in the reduction of postoperative complications remains uncertain in the literature. This systematic review and meta-analysis aimed to examine the effect of cerebral oximetry on the incidence of postoperative cognitive dysfunction in cardiac surgery. Databases of MEDLINE, EMBASE, and CENTRAL were searched from their inception until April 2021. All randomized controlled trials comparing cerebral oximetry and blinded/no cerebral oximetry in adult patients undergoing cardiac surgery were included. Observational studies, case series, and case reports were excluded. A total of 14 trials (n = 2,033) were included in this review. Our pooled data demonstrated that patients with cerebral oximetry were associated with a lower incidence of postoperative cognitive dysfunction than the control group (studies = 4, n = 609, odds ratio [OR]: 0.15, 95% confidence interval [CI]: 0.04 to 0.54, P = 0.003, I = 88%; certainty of evidence = very low). In terms of postoperative delirium (OR: 0.75, 95%CI: 0.50-1.14, P = 0.18, I = 0%; certainty of evidence = low) and postoperative stroke (OR: 0.81 95%CI: 0.37-1.80, P = 0.61, I = 0%; certainty of evidence = high), no significant differences (P > 0.05) were reported between the cerebral oximetry and control groups. In this meta-analysis, the use of cerebral oximetry monitoring in cardiac surgery demonstrated a lower incidence of postoperative cognitive dysfunction. However, this finding must be interpreted with caution due to the low level of evidence, high degree of heterogeneity, lack of standardized cognitive assessments, and cerebral desaturation interventions.
Topics: Adult; Cardiac Surgical Procedures; Delirium; Humans; Oximetry; Postoperative Cognitive Complications; Postoperative Complications; Randomized Controlled Trials as Topic
PubMed: 36254901
DOI: 10.4103/aca.aca_149_21 -
JAMA Network Open Mar 2023High-dose docosahexaenoic acid (DHA), a long-chain polyunsaturated fatty acid, may affect the risk of bronchopulmonary dysplasia (BPD). However, high-level summative... (Meta-Analysis)
Meta-Analysis
Association Between Enteral Supplementation With High-Dose Docosahexaenoic Acid and Risk of Bronchopulmonary Dysplasia in Preterm Infants: A Systematic Review and Meta-analysis.
IMPORTANCE
High-dose docosahexaenoic acid (DHA), a long-chain polyunsaturated fatty acid, may affect the risk of bronchopulmonary dysplasia (BPD). However, high-level summative evidence supporting such clinical association in very preterm infants is lacking.
OBJECTIVE
To examine the association between enteral supplementation with high-dose DHA during the neonatal period and the risk of BPD in preterm infants born at less than 29 weeks' gestation.
DATA SOURCES
PubMed, Embase, Web of Science, Cochrane Central Register of Controlled Trials, medRxiv, and ClinicalTrials.gov were searched from inception to August 1, 2022, for eligible articles with no language restrictions.
STUDY SELECTION
Randomized clinical trials (RCTs) were eligible for inclusion (1) if their interventions involved direct administration of a minimum DHA supplementation of 40 mg/kg/d or breast milk or formula feeding of at least 0.4% of total fatty acids, and (2) if they reported data on either BPD, death, BPD severity, or a combined outcome of BPD and death.
DATA EXTRACTION AND SYNTHESIS
Two investigators completed independent review of titles and abstracts, full text screening, data extraction, and quality assessment using the Cochrane Risk of Bias 2.0. Risk ratios (RRs) with 95% CIs were pooled using random-effect meta-analyses.
MAIN OUTCOMES AND MEASURES
Primary outcome was BPD using trial-specific definitions, which was further stratified for RCTs that used a more stringent BPD definition based on systematic pulse oximetry assessment at 36 weeks' postmenstrual age. Other outcomes were BPD, death, BPD severity, or combined BPD and death.
RESULTS
Among the 2760 studies screened, 4 RCTs were included, which involved 2304 infants (1223 boys [53.1%]; mean [SD] gestational age, 26.5 [1.6] weeks). Enteral supplementation with high-dose DHA was associated with neither BPD (4 studies [n = 2186 infants]; RR, 1.07 [95% CI, 0.86-1.34]; P = .53; I2 = 72%) nor BPD or death (4 studies [n = 2299 infants]; RR, 1.04 [95% CI, 0.91-1.18]; P = .59; I2 = 61%). However, an inverse association with BPD was found in RCTs that used a more stringent BPD definition (2 studies [n = 1686 infants]; RR, 1.20 [95% CI, 1.01-1.42]; P = .04; I2 = 48%). Additionally, DHA was inversely associated with moderate-to-severe BPD (3 studies [n = 1892 infants]; RR, 1.16 [95% CI, 1.04-1.29]; P = .008; I2 = 0%).
CONCLUSIONS AND RELEVANCE
Results of this study showed that enteral supplementation with high-dose DHA in the neonatal period was not associated overall with BPD, but an inverse association was found in the included RCTs that used a more stringent BPD definition. These findings suggest that high-dose DHA supplementation should not be recommended to prevent BPD in very preterm infants.
Topics: Infant, Newborn; Infant; Male; Female; Humans; Adult; Docosahexaenoic Acids; Bronchopulmonary Dysplasia; Infant, Premature; Gestational Age; Infant, Premature, Diseases; Fetal Growth Retardation; Dietary Supplements
PubMed: 36943265
DOI: 10.1001/jamanetworkopen.2023.3934 -
The Lancet. Digital Health Apr 2022The COVID-19 pandemic has led health systems to increase the use of tools for monitoring and triaging patients remotely. In this systematic review, we aim to assess the... (Review)
Review
The COVID-19 pandemic has led health systems to increase the use of tools for monitoring and triaging patients remotely. In this systematic review, we aim to assess the effectiveness and safety of pulse oximetry in remote patient monitoring (RPM) of patients at home with COVID-19. We searched five databases (MEDLINE, Embase, Global Health, medRxiv, and bioRxiv) from database inception to April 15, 2021, and included feasibility studies, clinical trials, and observational studies, including preprints. We found 561 studies, of which 13 were included in our narrative synthesis. These 13 studies were all observational cohorts and involved a total of 2908 participants. A meta-analysis was not feasible owing to the heterogeneity of the outcomes reported in the included studies. Our systematic review substantiates the safety and potential of pulse oximetry for monitoring patients at home with COVID-19, identifying the risk of deterioration and the need for advanced care. The use of pulse oximetry can potentially save hospital resources for patients who might benefit the most from care escalation; however, we could not identify explicit evidence for the effect of RPM with pulse oximetry on health outcomes compared with other monitoring models such as virtual wards, regular monitoring consultations, and online or paper diaries to monitor changes in symptoms and vital signs. Based on our findings, we make 11 recommendations across the three Donabedian model domains and highlight three specific measurements for setting up an RPM system with pulse oximetry.
Topics: COVID-19; Humans; Monitoring, Physiologic; Oximetry; Pandemics
PubMed: 35337644
DOI: 10.1016/S2589-7500(21)00276-4