Cardiology 2023Space travel imposes significant gravitational and radiation stress on both cellular and systemic physiology, resulting in myriad cardiovascular changes that have not...
INTRODUCTION
Space travel imposes significant gravitational and radiation stress on both cellular and systemic physiology, resulting in myriad cardiovascular changes that have not been fully characterized.
METHODS
We conducted a systematic review of the cellular and clinical adaptations of the cardiovascular system after exposure to real or simulated space travel in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The PubMed and Cochrane databases were searched in June 2021 for all peer-reviewed articles published since 1950 related to the following search terms entered in separate pairs: "cardiology and space" and "cardiology and astronaut." Only cellular and clinical studies in English concerning the investigation of cardiology and space were included.
RESULTS
Eighteen studies were identified, comprising 14 clinical and 4 cellular investigations. On the genetic level, pluripotent stem cells in humans and cardiomyocytes in mice displayed increased beat irregularity, with clinical studies revealing a persistent increase in heart rate after space travel. Further cardiovascular adaptations included a higher frequency of orthostatic tachycardia but no evidence of orthostatic hypotension, after return to sea level. Hemoglobin concentration was also consistently decreased after return to Earth. No consistent change in systolic or diastolic blood pressure or any clinically significant arrhythmias were observed during or after space travel.
CONCLUSION
Changes in oxygen carrying capacity, blood pressure, and post-flight orthostatic tachycardia may serve as reasons to further screen for pre-existing anemic and hypotensive conditions among astronauts.
Topics: Humans; Animals; Mice; Space Flight; Astronauts; Heart; Blood Pressure; Tachycardia
PubMed: 37302388
DOI: 10.1159/000531466 -
Revista Brasileira de Terapia Intensiva 2017To review the literature on the effects of expiratory rib cage compression on ventilatory mechanics, airway clearance, and oxygen and hemodynamic indices in mechanically... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE:
To review the literature on the effects of expiratory rib cage compression on ventilatory mechanics, airway clearance, and oxygen and hemodynamic indices in mechanically ventilated adults.
METHODS:
Systematic review with meta-analysis of randomized clinical trials in the databases MEDLINE (via PubMed), EMBASE, Cochrane CENTRAL, PEDro, and LILACS. Studies on adult patients hospitalized in intensive care units and under mechanical ventilation that analyzed the effects of expiratory rib cage compression with respect to a control group (without expiratory rib cage compression) and evaluated the outcomes static and dynamic compliance, sputum volume, systolic blood pressure, diastolic blood pressure, mean arterial pressure, heart rate, peripheral oxygen saturation, and ratio of arterial oxygen partial pressure to fraction of inspired oxygen were included. Experimental studies with animals and those with incomplete data were excluded.
RESULTS:
The search strategy produced 5,816 studies, of which only three randomized crossover trials were included, totaling 93 patients. With respect to the outcome of heart rate, values were reduced in the expiratory rib cage compression group compared with the control group [-2.81 bpm (95% confidence interval [95%CI]: -4.73 to 0.89; I2: 0%)]. Regarding dynamic compliance, there was no significant difference between groups [-0.58mL/cmH2O (95%CI: -2.98 to 1.82; I2: 1%)]. Regarding the variables systolic blood pressure and diastolic blood pressure, significant differences were found after descriptive evaluation. However, there was no difference between groups regarding the variables secretion volume, static compliance, ratio of arterial oxygen partial pressure to fraction of inspired oxygen, and peripheral oxygen saturation.
CONCLUSION:
There is a lack of evidence to support the use of expiratory rib cage compression in routine care, given that the literature on this topic offers low methodological quality and is inconclusive.
Topics: Adult; Blood Gas Analysis; Blood Pressure; Exhalation; Heart Rate; Humans; Oxygen; Pressure; Pulmonary Gas Exchange; Randomized Controlled Trials as Topic; Respiration, Artificial; Rib Cage
PubMed: 28444078
DOI: 10.5935/0103-507X.20170014 -
International Journal of Environmental... Dec 2021The number of overweight (OW) and obese (OB) children, adolescents, and adults has increased globally. Exercise intensity, both actual and perceived, is a significant... (Meta-Analysis)
Meta-Analysis Review
The number of overweight (OW) and obese (OB) children, adolescents, and adults has increased globally. Exercise intensity, both actual and perceived, is a significant factor in a variety of health-related investigations and rehabilitation trainings. Despite this, literature on the connection between actual exercise intensity and the rating of perceived exertion (RPE) in overweight and obese populations is lacking. A systematic review, meta-analysis, combined analysis of variance (Brown-Forsythe ANOVA), and Spearman correlation were performed to fill this gap. After preliminary assessments, ten studies were classified as having a low risk of bias and a degree of heterogeneity (I = 34%; = 0.05). The RPE scores (F = 0.032; = 0.859), physiological index (percentage of maximal heart rate (%HR) (F = 0.028; = 0.869), and percentage of maximal oxygen uptake (%VO) (F = 2.434; = 0.136) demonstrated consistency without being significantly different between the normal weight (NW) and OW/OB groups. The RPE scores varied by age (NW (coefficient values) = 0.677 ***, OW = 0.585 **), as well as by indoor temperature (OW only, coefficient values = 0.422 *), body mass index (NW (coefficient values) = 0.516 **, OW = 0.580 **), and test time (NW only, coefficient values = 0.451 *). We conclude that RPE is appropriate for the following OW and OB people: (1) those who are older than 21.5 (the lowest age in the group of ≥18) years old and younger than 58.6 (the highest age in the group of ≥18) years old, without any other diseases, and (2) those who engage in low-intensity exercise while maintaining a standard indoor temperature. Future studies may address alternative techniques for increasing the reliability of longitudinal comparisons and gender comparisons, as well as investigate other possible confounding factors.
Topics: Adolescent; Adult; Body Mass Index; Child; Humans; Obesity; Overweight; Physical Exertion; Reproducibility of Results
PubMed: 34948522
DOI: 10.3390/ijerph182412912 -
Anaesthesia Nov 2022We performed a systematic review and meta-analysis to identify, classify and evaluate the body of evidence on novel wearable and contactless devices that measure heart... (Meta-Analysis)
Meta-Analysis Review
We performed a systematic review and meta-analysis to identify, classify and evaluate the body of evidence on novel wearable and contactless devices that measure heart rate, respiratory rate and oxygen saturations in the clinical setting. We included any studies of hospital inpatients, including sleep study clinics. Eighty-four studies were included in the final review. There were 56 studies of wearable devices and 29 of contactless devices. One study assessed both types of device. A high risk of patient selection and rater bias was present in proportionally more studies assessing contactless devices compared with studies assessing wearable devices (p = 0.023 and p < 0.0001, respectively). There was high but equivalent likelihood of blinding bias between the two types of studies (p = 0.076). Wearable device studies were commercially available devices validated in acute clinical settings by clinical staff and had more real-time data analysis (p = 0.04). Contactless devices were more experimental, and data were analysed post-hoc. Pooled estimates of mean (95%CI) heart rate and respiratory rate bias in wearable devices were 1.25 (-0.31-2.82) beats.min (pooled 95% limits of agreement -9.36-10.08) and 0.68 (0.05-1.32) breaths.min (pooled 95% limits of agreement -5.65-6.85). The pooled estimate for mean (95%CI) heart rate and respiratory rate bias in contactless devices was 2.18 (3.31-7.66) beats.min (pooled limits of agreement -6.71-10.88) and 0.30 (-0.26-0.87) breaths.min (pooled 95% limits of agreement -3.94-4.29). Only two studies of wearable devices measured S O ; these reported mean measurement biases of 3.54% (limits of agreement -5.65-11.45%) and 2.9% (-7.4-1.7%). Heterogeneity was observed across studies, but absent when devices were grouped by measurement modality and reference standard. We conclude that, while studies of wearable devices were of slightly better quality than contactless devices, in general all studies of novel devices were of low quality, with small (< 100) patient datasets, typically not blinded and often using inappropriate statistical techniques. Both types of devices were statistically equivalent in accuracy and precision, but wearable devices demonstrated less measurement bias and more precision at extreme vital signs. The statistical variability in precision and accuracy between studies is partially explained by differences in reference standards.
Topics: Heart Rate; Humans; Monitoring, Physiologic; Oxygen; Oxygen Saturation; Respiratory Rate; Wearable Electronic Devices
PubMed: 35947876
DOI: 10.1111/anae.15834 -
World Journal of Surgery May 2016Globally, an estimated 2 billion people lack access to surgical and anesthesia care. We sought to pool results of anesthesia care capacity assessments in low- and... (Review)
Review
BACKGROUND
Globally, an estimated 2 billion people lack access to surgical and anesthesia care. We sought to pool results of anesthesia care capacity assessments in low- and middle-income countries (LMICs) to identify patterns of deficits and provide useful targets for advocacy and intervention.
METHODS
A systematic review of PubMed, Cochrane Database of Systematic Reviews, and Google Scholar identified reports that documented anesthesia care capacity from LMICs. When multiple assessments from one country were identified, only the study with the most facilities assessed was included. Patterns of availability or deficit were described.
RESULTS
We identified 22 LMICs (15 low- and 8 middle-income countries) with anesthesia care capacity assessments (614 facilities assessed). Anesthesia care resources were often unavailable, including relatively low-cost ones (e.g., oxygen and airway supplies). Capacity varied markedly between and within countries, regardless of the national income. The availability of fundamental resources for safe anesthesia, such as airway supplies and functional pulse oximeters, was often not reported (72 and 36 % of hospitals assessed, respectively). Anesthesia machines and the capability to perform general anesthesia were unavailable in 43 % (132/307 hospitals) and 56 % (202/361) of hospitals, respectively.
CONCLUSION
We identified a pattern of critical deficiencies in anesthesia care capacity in LMICs, including some low-cost, high-value added resources. The global health community should advocate for improvements in anesthesia care capacity and the potential benefits of doing so to health system planners. In addition, better quality data on anesthesia care capacity can improve advocacy, as well as the monitoring and evaluation of changes over time and the impact of capacity improvement interventions.
Topics: Anesthesiology; Developing Countries; Health Facilities; Health Resources; Humans; Needs Assessment
PubMed: 26822158
DOI: 10.1007/s00268-016-3430-4 -
BMJ Open Sport & Exercise Medicine 2023Dance is a popular physical activity. Increased dance training has been associated with an increased risk of injury. Given the established association between training... (Review)
Review
Dance is a popular physical activity. Increased dance training has been associated with an increased risk of injury. Given the established association between training load (TL) and injury in sport, knowledge of how TL is currently being measured in dance is critical. The objective of this study is to summarise published literature examining TL monitoring in dance settings. Six prominent databases (CINAHL, EMBASE, Medline, ProQuest, Scopus, SportDiscus) were searched and nine dance-specific journals were handsearched up to May 2022. Selected studies met inclusion criteria, where original TL data were collected from at least one dancer in a class, rehearsal and/or performance. Studies were excluded if TL was not captured in a dance class, rehearsal or performance. Two reviewers independently assessed each record for inclusion at title, abstract and full-text screening stages. Study quality was assessed using Joanna Briggs Institute Critical Appraisal Tool checklists for each study design. The 199 included studies reported on female dancers (61%), ballet genre (55%) and the professional level (31%). Dance hours were the most common tool used to measure TL (90%), followed by heart rate (20%), and portable metabolic systems (9%). The most common metric for each tool was mean weekly hours (n=381; median=9.5 hours, range=0.2-48.7 hours), mean heart rate (n=143) and mean oxygen consumption (n=93). Further research on TL is needed in dance, including a consensus on what tools and metrics are best suited for TL monitoring in dance.
PubMed: 37457429
DOI: 10.1136/bmjsem-2022-001484 -
Frontiers in Pharmacology 2023Severe pneumonia is a critical respiratory disease with high mortality. There is insufficient evidence on the efficacy and safety of traditional Chinese medicine (TCM)...
Efficacy and safety of traditional Chinese medicine adjuvant therapy for severe pneumonia: evidence mapping of the randomized controlled trials, systematic reviews, and meta-analyses.
Severe pneumonia is a critical respiratory disease with high mortality. There is insufficient evidence on the efficacy and safety of traditional Chinese medicine (TCM) adjuvant therapy for severe pneumonia. This study aims to identify, describe, assess, and summarize the currently available high-quality design evidence on TCM adjuvant therapy for severe pneumonia to identify evidence gaps using the evidence mapping approach. Systematic searches were performed on English and Chinese online databases (PubMed, EMBASE, Cochrane Library, Web of Science, CNKI, WanFang Data, CQVIP, and SinoMed) to identify papers from inception until August 2023 for inclusion into the review. Randomized controlled trials (RCTs), systematic reviews (SRs), and meta-analyses concerning TCM adjuvant therapy for severe pneumonia or its complications in adults were included. The risk of bias in RCTs was evaluated by using the ROB tool. The Assessment of Multiple Systematic Reviews 2 (AMSTAR-2), the Risk of Bias in Systematic Review (ROBIS) tool, and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system were used to assess the methodological quality, risk of bias, and evidence quality of SRs or meta-analyses, respectively. Then, a bubble plot was designed to visually display information in four dimensions. A total of 354 RCTs and 17 SRs or meta-analyses met the inclusion criteria. The published RCTs had several flaws, such as unreasonable design, limited sample size, insufficient attention to non-drug therapy studies and syndrome differentiation, improper selection or use of outcome indicators, and failure to provide high-quality evidence. Sixteen SRs or meta-analyses of methodological quality scored "Critically Low" confidence. Twelve SRs or meta-analyses were rated as "High Risk." Most outcomes were rated as "Low" evidence quality. We found that TCM combined with conventional treatment could improve the clinical total effective rate and the TCM syndromes efficacy. The combined approach could also shorten mechanical ventilation time, infection control time, and length of hospital and ICU stay; significantly reduce temperature, respiratory rate, heart rate, white blood cell counts, levels of C-reactive protein, procalcitonin, blood inflammatory factors, bacteriological response, and D-dimer; decrease CPIS, APACHE II score, and PSI score; improve pulmonary imaging features, arterial blood gas indicators (including arterial oxygen pressure, arterial oxygen saturation, and oxygen index), and lung function (including forced vital capacity and forced expiratory volume in the first second) for severe pneumonia compared with conventional treatment only ( < 0.05). There was no significant difference in adverse reactions and incidence of adverse events ( > 0.05). In addition, compared with conventional treatment only, most SRs or meta-analyses concluded that TCM combined with conventional treatment was "Beneficial" or "Probably beneficial." TCM combined with conventional treatment had advantages in efficacy, clinical signs, laboratory results, and life quality outcomes of severe pneumonia, with no difference in safety outcomes compared with conventional treatment only. QingJin Huatan decoction is the most promising target, and Xuanbai Chengqi decoction has a "Probably beneficial" conclusion. XueBiJing injection and TanReQing injection are two commonly used Chinese herbal injections for treating severe pneumonia, and both are "Probably beneficial." However, there was a need for multicenter RCTs with large sample sizes and high methodological quality in the future. In addition, the methodological design and quality of SRs or meta-analyses should be improved to form high-quality, evidence-based medical evidence and provide evidence for the effectiveness and safety of TCM adjuvant therapy for severe pneumonia.
PubMed: 37841930
DOI: 10.3389/fphar.2023.1227436 -
Frontiers in Cardiovascular Medicine 2022Congenital heart disease (CHD) entails structural defects in the morphogenesis of the heart or its main vessels. Analyzing exercise capacity of children and adolescents...
BACKGROUND
Congenital heart disease (CHD) entails structural defects in the morphogenesis of the heart or its main vessels. Analyzing exercise capacity of children and adolescents with CHD is important to improve their functional condition and quality of life, since it can allow timely intervention on poor prognostic factors associated with higher risk of morbidity and mortality.
OBJECTIVE
To describe exercise capacity in children and adolescents with CHD compared with healthy controls.
METHODS
A systematic review was carried out. Randomized clinical trials and observational studies were included assessing exercise capacity through direct and indirect methods in children and adolescents between 5 and 17 years-old. A sensitive analysis was performed including studies with CHD repaired participants. Additionally, it was sub-analyzed by age range (< and ≥ 12 years old). Two independent reviewers analyzed the studies, extracted the data, and assessed the quality of the evidence.
RESULTS
5619 articles were found and 21 were considered for the review. Eighteen articles used the direct exercise capacity measurement method by cardiopulmonary exercise test (CPET). The CHD group showed significant differences in peak oxygen consumption (VOpeak) with a value of -7.9 ml/Kg/min (95% CI: -9.9, -5.9, = 0.00001), maximum workload (Wmax) -41.5 (95% CI: -57.9, -25.1 watts, = 0.00001), ventilatory equivalent (VE/VCO 2.6 (95% CI: 0.3, 4.8), oxygen pulse (O pulse)-2.4 ml/beat (95% CI: -3.7, -1.1, = 0.0003), and maximum heart rate (HRmax) -15 bpm (95% CI: -18, -12 bpm, = 0.00001), compared with healthy controls. Adolescents (≥ 12 yrs) with CHD had a greater reduction in VOpeak (-10.0 ml/Kg/min (95% CI: -12.0, -5.3), < 0.00001), Wmax (-45.5 watts (95% CI: -54.4, -36.7), < 0.00001) and HRmax (-21 bpm (95% CI: -28, -14), <0.00001).
CONCLUSION
Suffering CHD in childhood and adolescence is associated with lower exercise capacity as shown by worse VOpeak, Wmax, VE/VCO slope, O pulse, and HRmax compared with matched healthy controls. The reduction in exercise capacity was greater in adolescents.
SYSTEMATIC REVIEW REGISTRATION
www.crd.york.ac.uk/prospero/display_record.php?RecordID=208963, identifier: CRD42020208963.
PubMed: 35600470
DOI: 10.3389/fcvm.2022.874700 -
Frontiers in Psychology 2023The practice of racket sports has had an exponential growth in the last decade, along with it, the scientific interest in researching the different disciplines:... (Review)
Review
The practice of racket sports has had an exponential growth in the last decade, along with it, the scientific interest in researching the different disciplines: badminton, padel, table tennis, tennis, and squash. However, most research has focused on the technical and tactical field. Therefore, the aim of this review is to analyze and compare the indicators of the internal load of each sport: heart rate (HR), maximum oxygen consumption (VO), oxygen consumption (VO), and lactate (LA) in order to reset physiological references to adjust the training of the players and also use these references to propose the practice of these sports for healthy purposes to the general population. PRISMA Guidelines for Systematic Review were used to search for articles that met the inclusion criteria in three databases: Web of Science, Pubmed, and Sportdiscus. The search was performed between January 2010, and September 2022. Finally, a total 27 records were included for analysis in this study. The main findings were related to the differences in the intensity rates between sports. The highest lactate concentrations and heart values were found in badminton in the intensity of effort values (whose highest values were found in badminton) 10.11 (±4.99) mmol/L and 182.6 (±2.7) bpm respectively, whereas table tennis showed the lowest ones 1.2 (± 0.4) mmol/L, and 103.99 (±15.09) bpm, respectively. The highest mean VO was found in table tennis with a value of 36.8 (±13.2) ml/kg/min and the lowest in tennis with a value of 26.6 (±2.7) ml/kg/min. The highest VO was found in tennis players 58.0 (±4.6) ml/kg/min, and the lowest value was in table tennis with a value of 42.9 (±4.2) ml/kg/min. Since most of the studies were carried out on elite men players, future research should focus on amateur and women level players.
PubMed: 37063547
DOI: 10.3389/fpsyg.2023.1149295 -
Nursing Open Jan 2024To critically assess the effects of white noise on the pain level, weight gain and vital signs (heart rate, respiratory rate and oxygen saturation) of preterm infants in... (Meta-Analysis)
Meta-Analysis Review
AIM
To critically assess the effects of white noise on the pain level, weight gain and vital signs (heart rate, respiratory rate and oxygen saturation) of preterm infants in neonatal intensive care units (NICUs).
DESIGN
A systematic review and meta-analysis of randomised controlled trials (RCTs).
METHODS
Ten databases (PubMed, Cochrane Library, Embase, Web of Science, CINAHL, PsycINFO, SinoMed, China National Knowledge Infrastructure, VIP and Wanfang Data) were systematically reviewed from inception to July 2022. Two reviewers evaluated the risk of bias separately using the Cochrane Collaboration criteria and extracted data using a predesigned information form.
RESULTS
The meta-analysis included eight eligible RCTs. According to statistical analysis, white noise significantly affected the pain level, weight gain, heart rate, respiratory rate and oxygen saturation in preterm infants. Regardless of the outcome measurement timing, gestational age and birth weight of preterm infants, subgroup analysis demonstrated that white noise reduced the pain level, heart rate and respiratory rate and promoted weight gain in preterm infants in NICUs.
CONCLUSION
White noise is a practical and potentially useful therapy for premature neonates in NICUs. No Patient or Public Contribution.
Topics: Infant; Infant, Newborn; Humans; Intensive Care Units, Neonatal; Infant, Premature; Birth Weight; Weight Gain; Pain
PubMed: 38268285
DOI: 10.1002/nop2.2094