-
International Journal of Environmental... Nov 2022The implementation of adjunctive antibiotics has been recommended for the therapy of peri-implantitis (PI). In this review, antibiotic resistance patterns in PI patients... (Review)
Review
The implementation of adjunctive antibiotics has been recommended for the therapy of peri-implantitis (PI). In this review, antibiotic resistance patterns in PI patients were assessed. A systematic scoping review of observational studies and trials was established in conjunction with the PRISMA extension for scoping reviews. The SCOPUS, PubMed/MEDLINE, EMBASE, SCIELO, Web of Science, and LILACS databases were reviewed along with the gray literature. The primary electronic examination produced 139 investigations. Finally, four observational studies met the selection criteria. These studies evaluated 214 implants in 168 patients. and mainly presented high resistance to tetracycline, metronidazole, and erythromycin in PI patients. Similarly, was also highly resistant to clindamycin and doxycycline. Other microorganisms such as , , and also presented significant levels of resistance to other antibiotics including amoxicillin, azithromycin, and moxifloxacin. However, most microorganisms did not show resistance to the combination amoxicillin metronidazole. Although the management of adjunctive antimicrobials in the therapy of PI is controversial, in this review, the resistance of relevant microorganisms to antibiotics used to treat PI, and usually prescribed in dentistry, was observed. Clinicians should consider the antibiotic resistance demonstrated in the treatment of PI patients and its public health consequences.
Topics: Humans; Peri-Implantitis; Aggregatibacter actinomycetemcomitans; Drug Resistance, Microbial; Fusobacterium nucleatum; Porphyromonas gingivalis; Amoxicillin; Metronidazole; Anti-Bacterial Agents
PubMed: 36497685
DOI: 10.3390/ijerph192315609 -
JACC. Cardiovascular Interventions Jun 2016This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS.
BACKGROUND
To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS).
METHODS
Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year.
RESULTS
A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization.
CONCLUSIONS
Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices.
Topics: Absorbable Implants; Bayes Theorem; Coronary Disease; Coronary Thrombosis; Drug-Eluting Stents; Humans; Markov Chains; Monte Carlo Method; Network Meta-Analysis; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Risk Assessment; Risk Factors; Time Factors; Treatment Outcome
PubMed: 27262860
DOI: 10.1016/j.jcin.2016.03.038 -
Nutrition Reviews May 2024It is well known that the microbiome undergoes cyclical diurnal rhythms. It has thus been hypothesized that meal timing may affect gut microbial composition, function,...
CONTEXT
It is well known that the microbiome undergoes cyclical diurnal rhythms. It has thus been hypothesized that meal timing may affect gut microbial composition, function, and host health.
OBJECTIVE
This review aims to examine the effects of time-restricted eating (TRE) and Ramadan fasting (RF) on the composition of the gut microbiota in animal and human studies. The associations between composition of microbiota and host metabolic parameters are also examined.
DATA SOURCES
A search was performed on the PubMed, Cochrane, Scopus, and Web of Science databases up to December 31, 2022. The search strategy was performed using the Medical Subject Heading (MeSH) terms "intermittent fasting" and "gastrointestinal microbiome" and the key words "Ramadan fasting" and "microbes."
DATA EXTRACTION
Seven human studies (4 TRE and 3 RF) and 9 animal studies (7 TRE, 2 RF-like) were retrieved.
DATA ANALYSIS
TRE and RF in human studies lead to an increase in gut microbial community alpha-diversity. In animal studies (both TRE and RF-like), fasting is not associated with improved alpha-diversity, but enhancement of microbial fluctuation is observed, compared with high-fat diet ad libitum groups. Within Firmicutes and Bacteroidetes phyla, no specific direction of changes resulting from fasting are observed in both animals and human. After TRE or RF, a greater abundance of the Faecalibacterium genus is observed in human studies; changes in Lactobacillus abundance are found in animal studies; and increases in Akkermansia are seen both in humans and in animals fed a feed-pellet diet. Only 2 human studies show a beneficial correlation between microbiota changes and host metabolic (HDL cholesterol) or anthropometric parameters (body mass index).
CONCLUSIONS
These findings support the importance of both regimens in improving the gut microbiota composition. However, based on results of animal studies, it can be suggested that diet remains the essential factor in forming the microbiota's environment.
SYSTEMATIC REVIEW REGISTRATION
PROSPERO registration no. CRD42021278918.
Topics: Gastrointestinal Microbiome; Humans; Fasting; Animals; Islam
PubMed: 37528052
DOI: 10.1093/nutrit/nuad093 -
The International Journal, Advanced... 2021This paper presents a systematic review on extrusion additive manufacturing (EAM), with focus on the technological development of screw-assisted systems that can be fed... (Review)
Review
This paper presents a systematic review on extrusion additive manufacturing (EAM), with focus on the technological development of screw-assisted systems that can be fed directly with granulated materials. Screw-assisted EAM has gained importance as an enabling technology to expand the range of 3D printing materials, reduce costs associated with feedstock fabrication, and increase the material deposition rate compared to traditional fused filament fabrication (FFF). Many experimental printheads and commercial systems that use some screw-processing mechanism can be found in the literature, but the design diversity and lack of standard terminology make it difficult to determine the most suitable solutions for a given material or application field. Besides, the few previous reviews have offered only a glimpse into the topic, without an in-depth analysis about the design of the extruders and associated capabilities. A systematic procedure was devised to identify the screw-assisted EAM systems that can print directly from granulated materials, resulting in 61 articles describing different pieces of equipment that were categorized as experimental printheads and commercial systems, for small- and large-scale applications. After describing their main characteristics, the most significant extruder modifications were discussed with reference to the materials processed and performance requirements. In the end, a general workflow for the development of 3D printers based on screw extrusion was proposed. This review intends to provide information about the state-of-the-art screw-assisted EAM and help the academy to identify further research opportunities in the field.
PubMed: 34092883
DOI: 10.1007/s00170-021-07365-z -
EuroIntervention : Journal of EuroPCR... Jun 2016Several studies have suggested good procedural and similar clinical outcomes between everolimus-eluting Absorb bioresorbable stents (BRS) versus conventional... (Comparative Study)
Comparative Study Meta-Analysis Review
AIMS
Several studies have suggested good procedural and similar clinical outcomes between everolimus-eluting Absorb bioresorbable stents (BRS) versus conventional drug-eluting stents (DES), but the evidence is not definitive. Our aim was to perform a systematic review and meta-analysis to investigate the effects of BRS versus conventional drug-eluting and bare metallic stents on the cardiovascular endpoints and all-cause mortality.
METHODS AND RESULTS
The follow-up in the included studies was up to 13 months. The following endpoints were evaluated: all-cause mortality, cardiac death, patient-oriented major adverse cardiac events (POCE), device-oriented major adverse cardiac events (DOCE), any-cause myocardial infarction (MI), target vessel MI (TVMI), target vessel revascularisation (TVR) and target lesion revascularisation (TLR). The results of 10 studies with 5,773 subjects showed a statistically significant increase in the risk of TVMI between BRS and conventional stents (odds ratio [OR]: 1.45, 95% confidence interval [CI]: 1.03-2.05, p=0.032). None of the other differences reached statistical significance: all-cause mortality (OR: 0.67, 95% CI: 0.30-1.49, p=0.333), cardiac death (OR: 1.00, 95% CI: 0.47-2.12, p=0.996), POCE (OR: 0.91, 95% CI: 0.68-1.22, p=0.546), DOCE (OR: 1.12, 95% CI: 0.86-1.46, p=0.387), any-cause MI (OR: 1.34, 95% CI: 0.98-1.82, p=0.064), TVR (OR: 0.99, 95% CI: 0.73-1.33, p=0.934) and TLR (OR: 0.92, 95% CI: 0.66-1.29, p=0.641). Similar results were observed after restricting the meta-analysis to the comparison of BRS vs. EES.
CONCLUSIONS
Our meta-analysis suggests a significantly higher risk of TVMI with BRS compared with conventional stents and no significant differences in the rates of occurrence of the other outcomes during one-year follow-up. Further studies with larger samples sizes, longer follow-up, different clinical scenarios and more complex lesions are required to confirm or refute our findings.
Topics: Absorbable Implants; Coronary Thrombosis; Drug-Eluting Stents; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Treatment Outcome
PubMed: 27290677
DOI: 10.4244/EIJY16M06_02 -
International Journal of Implant... Sep 2023This systematic review aimed to evaluate the incidence of microleakage events (IME) and to identify the potential factors influencing the sealing ability of the... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
This systematic review aimed to evaluate the incidence of microleakage events (IME) and to identify the potential factors influencing the sealing ability of the implant-abutment interface (IAI) under in vitro investigation.
MATERIAL AND METHODS
An electronic search of MEDLINE (PubMed), EMBASE, and Web of Science databases, combined with a manual literature search was conducted up to September 2022. In vitro studies that reported the degree of microleakage at IAI under dynamic loading conditions were included. A meta-analysis was performed to calculate the mean values of the incidence of microleakage events. Subgroup analysis and meta-regression were conducted to further investigate the effect of different variables.
RESULTS
675 studies were identified following the search process and 17 in vitro studies were selected according to the eligibility criteria. The weighted mean incidence of microleakage events was 47% (95% confidence interval: [0.33, 0.60]), indicating that contamination was observed in nearly half of the samples. Concerning possible factors that may influence microleakage (e.g., loading condition, assessment method, implant-abutment connection design, types of abutment material, the use of sealing agents), loading condition (p = 0.016) was the only variable that significantly influenced IME in the meta-regression analysis.
CONCLUSIONS
The results demonstrated that dynamic loading significantly increases the potential of bacterial penetration at the implant-abutment junction. The results should be interpreted carefully due to the data heterogeneity and further well-conducted in vitro studies with homogeneous samples are needed to standardize the methodologies.
Topics: Dental Implants; Databases, Factual; Drug Contamination; Electronics; Eligibility Determination
PubMed: 37733145
DOI: 10.1186/s40729-023-00494-y -
Dentistry Journal Jun 2023This systematic review synthesizes the existing evidence in the literature regarding the association of propolis with controlled delivery systems (DDSs) and its... (Review)
Review
This systematic review synthesizes the existing evidence in the literature regarding the association of propolis with controlled delivery systems (DDSs) and its potential therapeutic action in dental medicine. Two independent reviewers performed a literature search up to 1 June 2023 in five databases: PubMed/Medline, Web of Science, Cochrane Library, Scopus, and Embase, to identify the eligible studies. Clinical, in situ, and in vitro studies that investigated the incorporation of propolis as the main agent in DDSs for dental medicine were included in this study. Review articles, clinical cases, theses, dissertations, conference abstracts, and studies that had no application in dentistry were excluded. A total of 2019 records were initially identified. After carefully examining 21 full-text articles, 12 in vitro studies, 4 clinical, 1 animal model, and 3 in vivo and in vitro studies were included (n = 21). Relevant data were extracted from the included studies and analyzed qualitatively. The use of propolis has been reported in cariology, endodontics, periodontics, stomatology, and dental implants. Propolis has shown non-cytotoxic, osteoinductive, antimicrobial, and anti-inflammatory properties. Moreover, propolis can be released from DDS for prolonged periods, presenting biocompatibility, safety, and potential advantage for applications in dental medicine.
PubMed: 37504228
DOI: 10.3390/dj11070162 -
BMC Oral Health Oct 2023Type 2 diabetes mellitus (T2DM) is a major risk factor for localized diseases such as peri-implantitis that may affect ideal implant treatment. This study was aimed to... (Meta-Analysis)
Meta-Analysis
Evaluating the effect of mechanical debridement with adjunctive antimicrobial photodynamic therapy in comparison with mechanical debridement alone on the peri-implant parameters in type 2 diabetic mellitus patients with peri-implantitis: a systematic review and meta-analysis.
BACKGROUND
Type 2 diabetes mellitus (T2DM) is a major risk factor for localized diseases such as peri-implantitis that may affect ideal implant treatment. This study was aimed to evaluate the effect of mechanical debridement (MD) + antimicrobial photodynamic therapy (a-PDT) in patients with peri-implantitis who have T2DM in terms of bleeding on probing (BOP) and probing depth (PD) as primary outcomes and plaque index (PI) and crestal bone loss (CBL) as secondary outcomes.
METHODS
Publications compared outcomes between MD + aPDT and MD alone in T2DM patients with peri-implantitis, containing more than 3-month follow-up duration, were involved in the systematic review and meta-analysis. Literature until July 2023 using MEDLINE (through PubMed), Scopus, Cochrane Library, Embase, Web of Science, and Google Scholar were collected.
RESULTS
Two randomized controlled trials (RCTs, 88 individuals) and one controlled clinical trial (CCT, 67 individuals) with follow-up periods ranged from 3 to 12 months were recruited. All studies used diode laser with wavelengths ranged from 660 to 810 nm. The results demonstrated that the MD + aPDT group showed significant benefits for BOP reduction after 6 months (SMD = -2.15, 95% CI: -3.78 to -0.51, p = 0.01). However, a great amount of heterogeneity was observed (I = 91.52%, p < 0.001). Moreover, there was a significant difference between MD + aPDT and MD alone groups in CBL (SMD = -0.69, 95% CI: -1.07 to -0.30, p < 0.001). In addition, homogeneity assumption was satisfied (I = 22.49%, p = 0.28). Significant differences in PD and PI reduction were not found except for PI reduction after 3 months (SMD = -0.79, 95% CI: -1.24 to -0.33, p < 0.001. Also, no heterogeneity was observed (I = 0.00%, p = 0.47).
CONCLUSION
Given that high heterogeneity in BOP and PD outcome was found in this systematic review, future long-term CTs with MD + aPDT should be examined to arrive at a firm conclusion.
Topics: Humans; Peri-Implantitis; Debridement; Diabetes Mellitus, Type 2; Dental Implants; Photochemotherapy; Anti-Infective Agents
PubMed: 37828479
DOI: 10.1186/s12903-023-03337-9 -
JACC. Cardiovascular Interventions Jan 2017This study sought to compare the 2-year outcomes between bioresorbable vascular scaffold (BVS) and everolimus-eluting metallic drug-eluting stent (EES). (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
This study sought to compare the 2-year outcomes between bioresorbable vascular scaffold (BVS) and everolimus-eluting metallic drug-eluting stent (EES).
BACKGROUND
The occurrence of very late stent/scaffold thrombosis (VLST) of BVS beyond 1 year after implantation is an increasing concern.
METHODS
We conducted a meta-analysis of 24 studies (BVS: n = 2,567 and EES: n = 19,806) reporting the 2-year outcomes of BVS and/or EES to compare the risk of BVS versus EES for stent/scaffold thrombosis (ST) and target lesion failure (TLF) in 7 comparative studies (3 randomized and 4 observational), and to estimate the pooled incidence rates of ST and TLF including additional 17 single-arm studies.
RESULTS
In the 7 comparative studies, the risk for VLST between 1 and 2 years was numerically higher in BVS than in EES (odds ratio [OR]: 2.03 [95% confidence interval (CI): 0.62 to 6.71]). The excess risk of BVS relative to EES for ST through 2 years was significant (OR: 2.08 [95% CI: 1.02 to 4.26]). The risk for TLF was neutral between BVS and EES. In the 24 studies, the pooled estimated incidence rates of VLST, and ST through 2 years were higher in BVS than in EES (0.240 [95% CI: 0.022 to 0.608]% vs. 0.003 [95% CI: 0.000 to 0.028]%, and 1.43 [95% CI: 0.67 to 2.41]% vs. 0.56 [95% CI: 0.43 to 0.70]%, respectively). The corresponding rates for TLF were comparable between BVS and EES (1.88 [95% CI: 1.30 to 2.55]% and 1.78 [95% CI: 1.17 to 2.49]% and 7.90 [95% CI: 6.26 to 9.69]% and 7.49 [95% CI: 5.86 to 9.29]%, respectively).
CONCLUSIONS
In this meta-analysis, BVS as compared with EES was associated with higher risk for VLST between 1 and 2 years and ST through 2 years.
Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Incidence; Kaplan-Meier Estimate; Male; Metals; Middle Aged; Odds Ratio; Percutaneous Coronary Intervention; Propensity Score; Prosthesis Design; Risk Assessment; Risk Factors; Time Factors; Treatment Outcome
PubMed: 28057284
DOI: 10.1016/j.jcin.2016.10.027 -
Cureus Jun 2023Adults can accidentally swallow foreign bodies (FBs) with food. In rare occasions, these can lodge in the appendix lumen causing inflammation. This is known as foreign... (Review)
Review
Adults can accidentally swallow foreign bodies (FBs) with food. In rare occasions, these can lodge in the appendix lumen causing inflammation. This is known as foreign body appendicitis. We conducted this study to review different types and management of appendiceal FBs. A comprehensive search on PubMed, MEDLINE, Embase, Cochrane Library and Google Scholar was performed to detect appropriate case reports for this review. Case reports eligible for this review included patients above 18 years of age with all types of FB ingestion causing appendicitis. A total of 64 case reports were deemed to be eligible for inclusion in this systematic review. The patient mean age was 44.3 ± 16.7 years (range, 18-77). Twenty-four foreign bodies were identified in the adult appendix. They were mainly lead shot pellet, fishbone, dental crown or filling, toothpick, and others. Forty-two percent of the included patients presented with classic appendicitis pain, while 17% were asymptomatic. Moreover, the appendix was perforated in 11 patients. Regarding modalities used for diagnosis, computed tomography (CT) scans confirmed the presence of FBs in 59% of cases while X-ray only managed to detect 30%. Almost all of the cases (91%) were treated surgically with appendicectomy and only six were managed conservatively. Overall, lead shot pellets were the most common foreign body found. Fishbone and toothpick accounted for most of the perforated appendix cases. This study concludes that prophylactic appendicectomy is recommended for the management of foreign bodies detected in the appendix, even if the patient is asymptomatic.
PubMed: 37425596
DOI: 10.7759/cureus.40133