International Journal of Environmental... May 2021Arterial hypertension (HT) is a chronic condition of elevated blood pressure (BP), which may cause increased incidence of cardiovascular disease, stroke, kidney failure... (Review)
Review
Arterial hypertension (HT) is a chronic condition of elevated blood pressure (BP), which may cause increased incidence of cardiovascular disease, stroke, kidney failure and mortality. If the HT is diagnosed early, effective treatment can control the BP and avert adverse outcomes. Physiological signals like electrocardiography (ECG), photoplethysmography (PPG), heart rate variability (HRV), and ballistocardiography (BCG) can be used to monitor health status but are not directly correlated with BP measurements. The manual detection of HT using these physiological signals is time consuming and prone to human errors. Hence, many computer-aided diagnosis systems have been developed. This paper is a systematic review of studies conducted on the automated detection of HT using ECG, HRV, PPG and BCG signals. In this review, we have identified 23 studies out of 250 screened papers, which fulfilled our eligibility criteria. Details of the study methods, physiological signal studied, database used, various nonlinear techniques employed, feature extraction, and diagnostic performance parameters are discussed. The machine learning and deep learning based methods based on ECG and HRV signals have yielded the best performance and can be used for the development of computer-aided diagnosis of HT. This work provides insights that may be useful for the development of wearable for continuous cuffless remote monitoring of BP based on ECG and HRV signals.
Topics: Electrocardiography; Heart Rate; Humans; Hypertension; Monitoring, Physiologic; Photoplethysmography
PubMed: 34072304
DOI: 10.3390/ijerph18115838 -
Journal of Clinical Medicine Sep 2023Otolaryngological diagnoses, such as otitis media, are traditionally performed using endoscopy, wherein diagnostic accuracy can be subjective and vary among clinicians.... (Review)
Review
Otolaryngological diagnoses, such as otitis media, are traditionally performed using endoscopy, wherein diagnostic accuracy can be subjective and vary among clinicians. The integration of objective tools, like artificial intelligence (AI), could potentially improve the diagnostic process by minimizing the influence of subjective biases and variability. We systematically reviewed the AI techniques using medical imaging in otolaryngology. Relevant studies related to AI-assisted otitis media diagnosis were extracted from five databases: Google Scholar, PubMed, Medline, Embase, and IEEE Xplore, without date restrictions. Publications that did not relate to AI and otitis media diagnosis or did not utilize medical imaging were excluded. Of the 32identified studies, 26 used tympanic membrane images for classification, achieving an average diagnosis accuracy of 86% (range: 48.7-99.16%). Another three studies employed both segmentation and classification techniques, reporting an average diagnosis accuracy of 90.8% (range: 88.06-93.9%). These findings suggest that AI technologies hold promise for improving otitis media diagnosis, offering benefits for telemedicine and primary care settings due to their high diagnostic accuracy. However, to ensure patient safety and optimal outcomes, further improvements in diagnostic performance are necessary.
PubMed: 37762772
DOI: 10.3390/jcm12185831 -
Journal of Clinical Pathology Jul 2021Digital pathology (DP) has the potential to fundamentally change the way that histopathology is practised, by streamlining the workflow, increasing efficiency, improving... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Digital pathology (DP) has the potential to fundamentally change the way that histopathology is practised, by streamlining the workflow, increasing efficiency, improving diagnostic accuracy and facilitating the platform for implementation of artificial intelligence-based computer-assisted diagnostics. Although the barriers to wider adoption of DP have been multifactorial, limited evidence of reliability has been a significant contributor. A meta-analysis to demonstrate the combined accuracy and reliability of DP is still lacking in the literature.
OBJECTIVES
We aimed to review the published literature on the diagnostic use of DP and to synthesise a statistically pooled evidence on safety and reliability of DP for routine diagnosis (primary and secondary) in the context of validation process.
METHODS
A comprehensive literature search was conducted through PubMed, Medline, EMBASE, Cochrane Library and Google Scholar for studies published between 2013 and August 2019. The search protocol identified all studies comparing DP with light microscopy (LM) reporting for diagnostic purposes, predominantly including H&E-stained slides. Random-effects meta-analysis was used to pool evidence from the studies.
RESULTS
Twenty-five studies were deemed eligible to be included in the review which examined a total of 10 410 histology samples (average sample size 176). For overall concordance (clinical concordance), the agreement percentage was 98.3% (95% CI 97.4 to 98.9) across 24 studies. A total of 546 major discordances were reported across 25 studies. Over half (57%) of these were related to assessment of nuclear atypia, grading of dysplasia and malignancy. These were followed by challenging diagnoses (26%) and identification of small objects (16%).
CONCLUSION
The results of this meta-analysis indicate equivalent performance of DP in comparison with LM for routine diagnosis. Furthermore, the results provide valuable information concerning the areas of diagnostic discrepancy which may warrant particular attention in the transition to DP.
Topics: Artificial Intelligence; Diagnosis, Computer-Assisted; Humans; Image Interpretation, Computer-Assisted; Microscopy; Pathology, Clinical
PubMed: 32934103
DOI: 10.1136/jclinpath-2020-206764 -
Scandinavian Journal of Trauma,... Oct 2016Viscoelastic assays have been promoted as an improvement over traditional coagulation tests in the management of trauma patients. Rotational thromboelastometry (ROTEM®)... (Review)
Review
A systematic review on the rotational thrombelastometry (ROTEM®) values for the diagnosis of coagulopathy, prediction and guidance of blood transfusion and prediction of mortality in trauma patients.
INTRODUCTION
Viscoelastic assays have been promoted as an improvement over traditional coagulation tests in the management of trauma patients. Rotational thromboelastometry (ROTEM®) has been used to diagnose coagulopathy and guide hemostatic therapy in trauma. This systematic review of clinical studies in trauma investigates the ROTEM® parameters thresholds used for the diagnosing coagulopathy, predicting and guiding transfusion and predicting mortality.
METHODS
Systematic literature search was performed using MEDLINE, EMBASE and Cochrane databases. We included studies without restricting year of publication, language or geographic location. Original studies reporting the thresholds of ROTEM® parameters in the diagnosis or management of coagulopathy in trauma patients were included. Data on patient demographics, measures of coagulopathy, transfusion and mortality were extracted. We reported our findings according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Quality assessment and risk of bias were performed using Newcastle Ottawa Scale (NOS) and the quality assessment of diagnostic accuracy studies (QUADAS-2) tools, respectively.
RESULTS
A total of 13 observational studies involving 2835 adult trauma patients met the inclusion criteria. Nine studies were prospective and four were retrospective. There were no randomized controlled trials. The quality of the included studies was moderate (mean NOS 5.92, standard deviation 0.26). Using QUADAS-2, only 1 study (7.6 %) had low risk of bias in all domains, and 9 studies (69.2 %) had low risk of applicability concerns. Outcomes from 13 studies were grouped into three categories: diagnosis of coagulopathy (n = 10), prediction of massive transfusion or transfusion guidance (n = 6) and prediction of mortality (n = 6). Overall, specific ROTEM® parameters measured (clot amplitude and lysis) in the extrinsically activated test (EXTEM) and the fibrin-based extrinsically activated test (FIBTEM) were consistently associated with the diagnosis of coagulopathy, increased risk of bleeding and massive transfusion, and prediction of mortality. Presence of hyperfibrinolysis by ROTEM® was associated with increased mortality.
CONCLUSIONS
Most of the evidence indicates that abnormal EXTEM and FIBTEM clot amplitude (CA5, CA10) or maximal clot firmness (MCF) diagnose coagulopathy, and predict blood transfusion and mortality. The presence of fibrinolysis (abnormal lysis index [LI30] or maximum lysis [ML]) was also associated with mortality. ROTEM® thus, may be of value in the early management of trauma patients.
Topics: Blood Coagulation Disorders; Blood Coagulation Tests; Blood Transfusion; Global Health; Hemostasis; Humans; Practice Guidelines as Topic; Survival Rate; Thrombelastography; Wounds and Injuries
PubMed: 27716278
DOI: 10.1186/s13049-016-0308-2 -
European Journal of Nuclear Medicine... Jun 2021Polymyalgia rheumatica (PMR) can be difficult to diagnose. Whole-body [18F]FDG-PET/CT allows for a comprehensive evaluation of all relevant articular and extra-articular... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
Polymyalgia rheumatica (PMR) can be difficult to diagnose. Whole-body [18F]FDG-PET/CT allows for a comprehensive evaluation of all relevant articular and extra-articular structures affected by PMR. We aimed to summarize current evidence on the diagnostic value of [18F]FDG-PET/CT for a diagnosis of PMR.
METHODS
PubMed/MEDLINE and the Cochrane Library database were searched from inception through May 31, 2020. Studies containing patients with PMR who underwent [18F]FDG-PET/CT were included. Screening and full-text review were performed by 3 investigators and data extraction by 2 investigators. Risk of bias was examined with the QUADAS-2 tool. Diagnostic test meta-analysis was performed with a bivariate model.
RESULTS
Twenty studies were included in the systematic review, of which 9 studies (n = 636 patients) were eligible for meta-analysis. [18F]FDG positivity at the following sites was associated with a diagnosis of PMR: interspinous bursae (positive likelihood ratio (LR+) 4.00; 95% CI 1.84-8.71), hips (LR+ 2.91; 95% CI 2.09-4.05), ischial tuberosities (LR+ 2.86; 95% CI 1.91-4.28), shoulders (LR+ 2.57; 95% CI 1.24-5.32) and sternoclavicular joints (LR+ 2.31; 95% CI 1.33-4.02). Negative likelihood ratios (LR-) for these sites, as well as the greater trochanters, were all less than 0.50. Composite [18F]FDG-PET/CT scores, as reported in 3 studies, provided a pooled LR+ of 3.91 (95% CI 2.42-6.32) and LR- of 0.19 (95% CI 0.10-0.36). Moderate to high heterogeneity was observed across the studies, mainly due to differences in patient selection, scanning procedures and/or interpretation criteria.
CONCLUSION
Significant [18F]FDG uptake at a combination of anatomic sites is informative for a diagnosis of PMR. [18F]FDG-PET/CT might be an important diagnostic tool in patients with suspected PMR. This study also highlights the need for adherence to published procedural recommendations and standardized interpretation criteria for the use of [18F]FDG-PET/CT in PMR.
Topics: Fluorodeoxyglucose F18; Giant Cell Arteritis; Humans; Polymyalgia Rheumatica; Positron Emission Tomography Computed Tomography; Positron-Emission Tomography; Radiopharmaceuticals
PubMed: 33372248
DOI: 10.1007/s00259-020-05162-6 -
Neurological Sciences : Official... Apr 2021The aim of the present systematic revision is to analyze existing published reports about the use of home-videos recordings (HVRs) to support physicians in the... (Review)
Review
BACKGROUND
The aim of the present systematic revision is to analyze existing published reports about the use of home-videos recordings (HVRs) to support physicians in the differential diagnosis of paroxysmal seizure-like episodes (PSLE). We also developed practical recommendations in order to ensure adequate quality standards and safety advice for HVRs.
MATERIAL AND METHODS
A comprehensive search of PubMed, Medline, Scopus, and Google Scholar was performed, and results were included up to July 2020. All studies concerning the use of HVRs as a diagnostic tool for patients presenting PSLE were included.
RESULTS
Seventeen studies satisfied all inclusion and exclusion criteria and were considered for the review. A consistent boost in diagnostic and clinical decision-making was reported across all studies in the literature. One study found that HVRs decreased the stress level in many families and improved their quality of life. Training in performing good-quality videos is necessary and increases the diagnostic value of HVRs.
CONCLUSIONS
HVRs can be of diagnostic value in epilepsy diagnosis and management. HVRs are low cost, widespread, and may provide great support for neurologists. It is important to train patients and caregivers in performing good quality videos to optimize this useful tool and to guarantee safety standards during the recording.
Topics: Epilepsy; Humans; Neurologists; Quality of Life; Seizures; Video Recording
PubMed: 33471259
DOI: 10.1007/s10072-021-05040-5 -
International Journal of Molecular... Jun 2023Various papers have introduced the use of positron emission tomography (PET) with [Ga]Ga-radiolabeled fibroblast-activation protein inhibitor (FAPi) radiopharmaceuticals... (Meta-Analysis)
Meta-Analysis Review
Various papers have introduced the use of positron emission tomography (PET) with [Ga]Ga-radiolabeled fibroblast-activation protein inhibitor (FAPi) radiopharmaceuticals in different subtypes of gastric cancer (GC). Our aim was to assess the diagnostic performance of this novel molecular imaging technique in GC with a systematic review and meta-analysis. A straightforward literature search of papers concerning the diagnostic performance of FAP-targeted PET imaging was performed. Original articles evaluating this novel molecular imaging examination in both newly diagnosed GC patients and GC patients with disease relapse were included. The systematic review included nine original studies, and eight of them were also eligible for meta-analysis. The quantitative synthesis provided pooled detection rates of 95% and 97% for the assessment of primary tumor and distant metastases, respectively, and a pooled sensitivity and specificity of 74% and 89%, respectively, for regional lymph node metastases. Significant statistical heterogeneity among the included studies was found only in the analysis of the primary tumor detection rate (I = 64%). Conclusions: Beyond the limitations of this systematic review and meta-analysis (i.e., all the included studies were conducted in Asia, and using [F]FDG PET/CT as a comparator of the index test), the quantitative data provided demonstrate the promising diagnostic performance of FAP-targeted PET imaging in GC. Nevertheless, more prospective multicentric studies are needed to confirm the excellent performances of FAP-targeted PET in this cluster of patients.
Topics: Humans; Positron Emission Tomography Computed Tomography; Stomach Neoplasms; Prospective Studies; Neoplasm Recurrence, Local; Positron-Emission Tomography; Radiopharmaceuticals; Fluorodeoxyglucose F18; Gallium Radioisotopes
PubMed: 37373285
DOI: 10.3390/ijms241210136 -
BMC Medical Imaging Dec 2023The gold standard to diagnose fatty liver is pathology. Recently, image-based artificial intelligence (AI) has been found to have high diagnostic performance. We... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The gold standard to diagnose fatty liver is pathology. Recently, image-based artificial intelligence (AI) has been found to have high diagnostic performance. We systematically reviewed studies of image-based AI in the diagnosis of fatty liver.
METHODS
We searched the Cochrane Library, Pubmed, Embase and assessed the quality of included studies by QUADAS-AI. The pooled sensitivity, specificity, negative likelihood ratio (NLR), positive likelihood ratio (PLR), and diagnostic odds ratio (DOR) were calculated using a random effects model. Summary receiver operating characteristic curves (SROC) were generated to identify the diagnostic accuracy of AI models.
RESULTS
15 studies were selected in our meta-analysis. Pooled sensitivity and specificity were 92% (95% CI: 90-93%) and 94% (95% CI: 93-96%), PLR and NLR were 12.67 (95% CI: 7.65-20.98) and 0.09 (95% CI: 0.06-0.13), DOR was 182.36 (95% CI: 94.85-350.61). After subgroup analysis by AI algorithm (conventional machine learning/deep learning), region, reference (US, MRI or pathology), imaging techniques (MRI or US) and transfer learning, the model also demonstrated acceptable diagnostic efficacy.
CONCLUSION
AI has satisfactory performance in the diagnosis of fatty liver by medical imaging. The integration of AI into imaging devices may produce effective diagnostic tools, but more high-quality studies are needed for further evaluation.
Topics: Humans; Artificial Intelligence; Sensitivity and Specificity; ROC Curve; Magnetic Resonance Imaging; Fatty Liver
PubMed: 38082213
DOI: 10.1186/s12880-023-01172-6 -
European Journal of Nuclear Medicine... Jan 2021Left ventricular assist devices (LVADs) are increasingly used for the treatment of advanced heart failure. LVADs improve quality of life and decrease mortality, but the... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Left ventricular assist devices (LVADs) are increasingly used for the treatment of advanced heart failure. LVADs improve quality of life and decrease mortality, but the driveline carries substantial risk for major infections. These device-related LVAD and driveline infections are difficult to diagnose with conventional imaging. We reviewed and analysed the current literature on the additive value of F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) imaging for the diagnosis of LVAD-related infections."
MATERIALS/METHODS
We performed a systematic literature review using several databases from their inception until the 31st of December, 2019. Studies investigating the diagnostic performance of FDG-PET/CT in patients with suspected LVAD infection were retrieved. After a bias risk assessment using QUADAS-2, a study-aggregate meta-analysis was performed on a per examination-based analysis.
RESULTS
A total of 10 studies were included in the systematic review, eight of which were also eligible for study-aggregate meta-analysis. For the meta-analysis, a total of 256 FDG-PET/CT scans, examining pump/pocket and/or driveline infection, were acquired in 230 patients. Pooled sensitivity of FDG-PET/CT was 0.95 (95% confidence interval (CI) 0.89-0.97) and pooled specificity was 0.91 (95% CI 0.54-0.99) for the diagnosis of device-related infection. For pump/pocket infection, sensitivity and specificity of FDG-PET/CT were 0.97 (95%CI 0.69-1.00) and 0.93 (95%CI 0.64-0.99), respectively. For driveline infection, sensitivity and specificity were 0.96 (95%CI 0.88-0.99) and 0.99 (95%CI 0.13-1.00) respectively. Significant heterogeneity existed across studies for specificity, mostly caused by differences in scan procedures. Predefined criteria for suspicion of LVAD and/or driveline infection were lacking in all included studies.
CONCLUSIONS
FDG-PET/CT is a valuable tool for assessment of device-related infection in LVAD patients, with high sensitivity and high, albeit variable, specificity. Standardization of FDG-PET/CT procedures and criteria for suspected device-related LVAD infections are needed for consistent reporting of FDG-PET/CT scans.
Topics: Fluorodeoxyglucose F18; Heart-Assist Devices; Humans; Positron Emission Tomography Computed Tomography; Positron-Emission Tomography; Prosthesis-Related Infections; Quality of Life; Radiopharmaceuticals; Sensitivity and Specificity
PubMed: 32594196
DOI: 10.1007/s00259-020-04930-8 -
BMC Psychiatry Feb 2022Cognitive disorders and dementia have an important effect on individual independence and orientation. According to the Alzheimer's Disease International (ADI) 75% of... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Cognitive disorders and dementia have an important effect on individual independence and orientation. According to the Alzheimer's Disease International (ADI) 75% of people with dementia are not diagnosed; this may be as high as 90% in some low- and middle-income countries. This systematic review and meta-analysis aimed to identify the test performance of screening tools and compare them pairwise. The findings of our study can support countries in planning to establish and care for mild cognitive impairment in primary health centers.
METHODS
Medline (PubMed), Scopus, Cochrane, Dare, All EBM Reviews, CRD (OVID), and Proquest were searched from 2012 to November 2021. The risk of bias was assessed through the QUADAS-2 instrument. Given the high heterogeneity between studies, a random-effects model was used to calculate the pooled effect sizes for diagnostic accuracy measures (sensitivity, specificity, and area under curve indices). I test was used for assessing heterogeneity and predefined subgroup analyses were performed using participants' age, country's income, and sample size of studies.
RESULTS
A systematic search identified 18,132 records, of which, 20 studies were included in the quality assessment, and six were included in quantitative analysis. None of the studies had examined the feasibility or efficiency of mass screening. According to a pairwise comparison, IQCODE, AD8 and GPCOG showed equal or better diagnostic performance relative to the MMSE in terms of sensitivity and specificity. The random-effect model for the MMSE showed the pooled sensitivity equal to 0.73 (95% CI 0.57-0.90), the pooled specificity equal to 0.83 (95% CI 0.75-0.90), and the pooled AUC equal to 0.88 (95% CI 0.83-0.93).
CONCLUSION
Several benefits have been attached to short tests making them a suitable choice for use in primary healthcare settings. Considering factors such as accuracy, time of application, ease of scoring, and utilization charges, tests such as IQCODE, AD8, and GPCOG or appropriate combination with counterpart tools seem to be good alternatives to the use of the MMSE in primary care.
Topics: Cognition Disorders; Cognitive Dysfunction; Dementia; Humans; Mass Screening; Primary Health Care
PubMed: 35139803
DOI: 10.1186/s12888-022-03730-8