Tricuspid valve repair concomitant with mitral valve surgery: a systematic review and meta-analysis.International Journal of Surgery... Jul 2023Uncertainties persist about whether to aggressively and effectively treat tricuspid regurgitation (TR) during mitral valve (MV) surgery. (Meta-Analysis)
Meta-Analysis
BACKGROUND
Uncertainties persist about whether to aggressively and effectively treat tricuspid regurgitation (TR) during mitral valve (MV) surgery.
REVIEW METHODS
Systematic literature searches were performed in five databases to collect all relevant studies published before May 2022 on whether the tricuspid valve was treated during MV surgery. Separate meta-analyses were performed on data from unmatched studies and randomized controlled trials (RCT)/adjusted studies.
MAIN RESULTS
A total of 44 publications were included, of which eight were RCT studies and the rest were retrospective studies. There was no difference in 30-day mortality [odds ratio (OR): 1.00, 95% CI: 0.71-1.42, OR: 0.66, 95% CI: 0.30-1.41)] or overall survival [hazard ratio (HR): 1.01, 95% CI: 0.85-1.19, HR: 0.77, 95% CI: 0.52-1.14] in unmatched studies and RCT/adjusted studies. Late mortality (OR: 0.37, 95% CI: 0.21-0.64) and cardiac-related mortality (OR: 0.36, 95% CI: 0.21-0.62) were lower in the tricuspid valve repair (TVR) group in the RCT/adjusted studies. In the unmatched studies, overall cardiac mortality (OR: 0.48, 95% CI: 0.26-0.88) was lower in the TVR group. In the late TR progression analysis, the late TR progression was lower among patients in the concomitantly intervened tricuspid group, and patients in the untreated tricuspid group were prone to TR progression in both studies (HR: 0.30, 95% CI: 0.22-0.41, HR: 0.37, 95% CI: 0.23-0.58).
CONCLUSIONS
TVR concomitant with MV surgery is most effective in patients with significant TR and dilated tricuspid annulus, especially those with a significantly reduced risk of distant TR progression.
Topics: Humans; Tricuspid Valve; Mitral Valve; Mitral Valve Insufficiency; Treatment Outcome; Heart Valve Prosthesis Implantation; Tricuspid Valve Insufficiency; Retrospective Studies
PubMed: 37300887
DOI: 10.1097/JS9.0000000000000396 -
Frontiers in Cardiovascular Medicine 2022Patient-prosthesis mismatch (PPM) remains one out of many factors to be considered during decision-making for the treatment of aortic valve pathologies. The idea of...
Patient-prosthesis mismatch (PPM) remains one out of many factors to be considered during decision-making for the treatment of aortic valve pathologies. The idea of adequate sizing of a prosthetic heart valve was established by Rahimtoola already in 1978. In this article, the author described the phenomenon that the orifice area of a prosthetic heart valve may be too small for the individual patient. PPM is assessed by measurement or projection of the prosthetic effective orifice area indexed to body surface area (iEOA), while it is recommended to use different cut point values for non-obese and obese patients for the categorization of moderate and severe PPM. Several factors influence the accuracy of both the projected and the measured iEOA for PPM assessment, which leads to a certain number of false assignments to the PPM or no PPM group. Despite divergent findings on the impact of PPM on clinical outcomes, there is consensus that PPM should be avoided to prevent sequelae of increased prosthetic gradients after aortic valve replacement. To prevent PPM, it is required to anticipate the iEOA of the prosthesis prior to the procedure. The use of adequate reference tables, derived from echocardiographically measured mean effective orifice area (EOA) values from preferably large numbers of patients, is most appropriate to predict the iEOA. Such tables should be used also for transcatheter heart valves in the future. During the decision-making process, all available options should be taken into account for the individual patient. If the predicted size and type of a surgical prosthesis cannot be implanted, additional surgical procedures, such as annular enlargement with the Manougian technique, or alternative procedures, such as transcatheter aortic valve implantation (TAVI) can prevent PPM. PPM prevention for TAVI patients is a new field of interest and includes anticipation of the iEOA, prosthesis selection, and procedural strategies.
PubMed: 35433878
DOI: 10.3389/fcvm.2022.761917 -
Journal of the American Heart... Jun 2022Background There is a concern that resheathing/repositioning of transcatheter heart valves during transcatheter aortic valve implantation (TAVI) may lead to an increased... (Meta-Analysis)
Meta-Analysis Review
Background There is a concern that resheathing/repositioning of transcatheter heart valves during transcatheter aortic valve implantation (TAVI) may lead to an increased risk of periprocedural complications. We aimed to evaluate the short- and long-term impact on clinical outcomes of resheathing for repositioning of transcatheter heart valves during TAVI procedures. Methods and Results We conducted a systematic search of Embase, MEDLINE, and Cochrane Central Register of Controlled Trials databases to identify studies comparing outcomes between patients requiring resheathing/repositioning during TAVI and those who did not. Random-effects meta-analyses were used to estimate the association of resheathing compared with no resheathing with clinical outcomes after TAVI. Seven studies including 4501 participants (pooled mean age, 80.9±7.4 years; 54% women; and 1374 [30.5%] patients requiring resheathing/repositioning) were included in this study. No significant differences between the 2 groups were identified with regards to safety: 30-day mortality (n=3125; odds ratio [OR], 0.74 [95% confidence interval [CI], 0.41-1.33]; =0%), stroke (n=4121; OR, 1.09 [95% CI, 0.74-1.62]; =0%), coronary obstruction (n=3000; OR, 2.35 [95% CI, 0.17-33.47]; =75%), major vascular complications (n=3125; OR, 0.92 [95% CI, 0.66-1.33]; =0%), major bleeding (n=3125; OR, 1.13 [95% CI, 0.94-2.01]; =39%), acute kidney injury (n=3495; OR, 1.30 [95% CI, 0.64-2.62]; =44%), and efficacy outcomes: device success (n=1196; OR, 0.77 [95% CI, 0.51-1.14]; =0%), need for a second valve (n=3170; OR, 2.86 [95% CI, 0.96-8.48]; =62%), significant (moderate or higher) paravalvular leak (n=1151; OR, 1.53 [95% CI, 0.83-2.80]; =0%), and permanent pacemaker implantation (n=1908; OR, 1.04 [95% CI, 0.68-1.57]; =58%). One-year mortality was similar between groups (n=1972; OR, 1.00 [95% CI, 0.68-1.47]; =0%). Conclusions Resheathing of transcatheter heart valves during TAVI is associated with similar periprocedural risk compared with no resheathing in several patient-important outcomes. These data support the safety of current self-expanding transcatheter heart valves with resheathing features. Registration URL: https://www.crd.york.ac.uk/prospero/; Unique identifier: CRD42021273715.
Topics: Aged; Aged, 80 and over; Aortic Valve; Aortic Valve Stenosis; Female; Heart Valve Prosthesis; Humans; Male; Postoperative Complications; Risk Factors; Stroke; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 35699176
DOI: 10.1161/JAHA.121.024707 -
European Heart Journal Sep 2023To support decision-making in children undergoing aortic valve replacement (AVR), by providing a comprehensive overview of published outcomes after paediatric AVR, and... (Meta-Analysis)
Meta-Analysis
AIMS
To support decision-making in children undergoing aortic valve replacement (AVR), by providing a comprehensive overview of published outcomes after paediatric AVR, and microsimulation-based age-specific estimates of outcome with different valve substitutes.
METHODS AND RESULTS
A systematic review of published literature reporting clinical outcome after paediatric AVR (mean age <18 years) published between 1/1/1990 and 11/08/2021 was conducted. Publications reporting outcome after paediatric Ross procedure, mechanical AVR (mAVR), homograft AVR (hAVR), and/or bioprosthetic AVR were considered for inclusion. Early risks (<30d), late event rates (>30d) and time-to-event data were pooled and entered into a microsimulation model. Sixty-eight studies, of which one prospective and 67 retrospective cohort studies, were included, encompassing a total of 5259 patients (37 435 patient-years; median follow-up: 5.9 years; range 1-21 years). Pooled mean age for the Ross procedure, mAVR, and hAVR was 9.2 ± 5.6, 13.0 ± 3.4, and 8.4 ± 5.4 years, respectively. Pooled early mortality for the Ross procedure, mAVR, and hAVR was 3.7% (95% CI, 3.0%-4.7%), 7.0% (5.1%-9.6%), and 10.6% (6.6%-17.0%), respectively, and late mortality rate was 0.5%/year (0.4%-0.7%/year), 1.0%/year (0.6%-1.5%/year), and 1.4%/year (0.8%-2.5%/year), respectively. Microsimulation-based mean life-expectancy in the first 20 years was 18.9 years (18.6-19.1 years) after Ross (relative life-expectancy: 94.8%) and 17.0 years (16.5-17.6 years) after mAVR (relative life-expectancy: 86.3%). Microsimulation-based 20-year risk of aortic valve reintervention was 42.0% (95% CI: 39.6%-44.6%) after Ross and 17.8% (95% CI: 17.0%-19.4%) after mAVR.
CONCLUSION
Results of paediatric AVR are currently suboptimal with substantial mortality especially in the very young with considerable reintervention hazards for all valve substitutes, but the Ross procedure provides a survival benefit over mAVR. Pros and cons of substitutes should be carefully weighed during paediatric valve selection.
Topics: Humans; Child; Adolescent; Aortic Valve; Heart Valve Prosthesis Implantation; Retrospective Studies; Prospective Studies; Heart Valve Prosthesis; Treatment Outcome
PubMed: 37366156
DOI: 10.1093/eurheartj/ehad370 -
Journal of Thrombosis and Haemostasis :... Aug 2014Prosthetic heart valve thrombosis is a life-threatening condition for which treatment has not been evaluated by randomized trials. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Prosthetic heart valve thrombosis is a life-threatening condition for which treatment has not been evaluated by randomized trials.
OBJECTIVES
To compare surgery with thrombolytic therapy for the treatment of prosthetic valve thrombosis.
METHODS
A comprehensive systematic review was carried out by independent researchers using PubMed, Web of Knowledge, HINARI, LILACS and EMBASE, including papers indexed up to 23 October 2013 with at least 10 patients, evaluating one or both treatment options. Outcomes of interest were death, stroke, bleeding, embolic events and success. Study quality was assessed by the Newcastle-Ottawa Scale (ranges from 0 to 9). Comprehensive Meta Analysis Software was used to pool study results, for publication bias analysis and for meta-regression.
RESULTS
Forty-eight studies were included (2302 patients). No randomized study was identified, and all were observational in design. Study quality varied from 4 to 6 stars using the Newcastle-Ottawa Scale. Mortality for surgery was 18.1% (95%CI, 14.6-22.1; I(2) , 62% [42-75]), while mortality for thrombolytic therapy was 6.6% (95% CI, 4.8-8.9; I(2) , 0% [0-13]). Surgical mortality appeared to increase with NYHA-class, according to meta-regression. Other results related to surgery and thrombolytic therapy, respectively, were: embolic events, 4.6% (2.9-7.3) and 12.8% (10.8-15.2); stroke, 4.3%,(2.7-6.6%) and 5.6%,(4.3-7.4%); success rate, 81.9% (77.2-85.8) and 80.7% (75.6-85.0); bleeding, 4.6% (2.9-7.1) and 6.8% (5.4-8.6); and death or stroke, 19.0% (14.8-24.2) and 11.4% (8.7-14.7).
CONCLUSION
Mortality in patients treated by thrombolytic therapy for valve prosthesis thrombosis is significantly lower than in patients treated surgically. As we cannot yet ascertain whether this difference is due to the treatment alone, more studies are now necessary to further clarify these findings.
Topics: Heart Valve Prosthesis; Humans; Thrombolytic Therapy; Thrombosis
PubMed: 24698327
DOI: 10.1111/jth.12577 -
BJOG : An International Journal of... Oct 2015Historically, pregnancies among women with prosthetic heart valves have been associated with an increased incidence of adverse outcomes. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Historically, pregnancies among women with prosthetic heart valves have been associated with an increased incidence of adverse outcomes.
OBJECTIVES
Systematic review to assess risk of adverse pregnancy outcomes among women with a prosthetic heart valve(s) over the last 20 years.
SEARCH STRATEGY
Electronic literature search of Medline, The Cochrane Library, Cumulative Index to Nursing and Allied Health Literature and Embase to find recent studies.
SELECTION CRITERIA
Studies of pregnant women with heart valve prostheses including trials, cohort studies and unselected case series.
DATA COLLECTION AND ANALYSIS
Primary analysis calculated absolute risks and 95% confidence intervals (CI) for pregnancy outcomes using a random effects model. The Freeman-Tukey transformation was utilised in secondary analysis due to the large number of individual study outcomes with zero events.
MAIN RESULTS
Eleven studies capturing 499 pregnancies among women with heart valve prostheses, including 256 mechanical and 59 bioprosthetic, were eligible for inclusion. Pooled estimate of maternal mortality was 1.2/100 pregnancies (95% CI 0.5-2.2), for mechanical valves subgroup 1.8/100 (95% CI 0.5-3.7) and bioprosthetic subgroup 0.7/100 (95% CI 0.1-4.5), overall pregnancy loss 20.8/100 pregnancies (95% CI 9.5-35.1), perinatal mortality 5.0/100 births (95%CI 1.8-9.8) and thromboembolism 9.3/100 pregnancies (95% CI 4.0-16.5).
CONCLUSIONS
Women with heart valve prostheses experienced higher rates of adverse outcomes than expected in a general obstetric population; however, lower than previously reported. Women with bioprostheses had significantly fewer thromboembolic events compared to women with mechanical valves. Women should be counselled pre-pregnancy about risk of maternal death and pregnancy loss. Vigilant surveillance by a multidisciplinary team throughout the perinatal period remains warranted for these women and their infants.
TWEETABLE ABSTRACT
Metaanalysis suggests improvement in #pregnancy outcomes among women with #heartvalveprostheses.
Topics: Bioprosthesis; Female; Fetal Death; Fetal Mortality; Heart Valve Prosthesis; Humans; Infant, Newborn; Maternal Mortality; Perinatal Mortality; Pregnancy; Pregnancy Complications, Cardiovascular; Pregnancy Outcome; Thromboembolism
PubMed: 26119028
DOI: 10.1111/1471-0528.13491 -
Journal of the American Heart... Dec 2022Background In the absence of randomized controlled trials, reports from nonrandomized studies comparing valve-in-valve implantation (ViV) to redo surgical aortic valve... (Meta-Analysis)
Meta-Analysis Review
Valve-in-Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement for Failed Surgical Aortic Bioprostheses: A Systematic Review and Meta-Analysis.
Background In the absence of randomized controlled trials, reports from nonrandomized studies comparing valve-in-valve implantation (ViV) to redo surgical aortic valve replacement (rAVR) have shown inconsistent results. Methods and Results PubMed/MEDLINE, Google Scholar, and CENTRAL (Cochrane Central Register of Controlled Trials) were searched through December 2021. Meta-Analysis of Observational Studies in Epidemiology guidelines were followed. The protocol was registered at the International Prospective Register of Systematic Reviews. Random effects models were applied. The primary outcomes of interest were short-term and midterm mortality. Secondary outcomes included stroke, myocardial infarction, acute renal failure, and permanent pacemaker implantation, as well as prosthetic aortic valve regurgitation, mean transvalvular gradient, and severe prosthesis-patient mismatch. Of 8881 patients included in 15 studies, 4458 (50.2%) underwent ViV and 4423 (49.8%) rAVR. Short-term mortality was 2.8% in patients undergoing ViV compared with 5.0% in patients undergoing rAVR (risk ratio [RR] 0.55 [95% CI, 0.34-0.91], =0.02). Midterm mortality did not differ in patients undergoing ViV compared with patients undergoing rAVR (hazard ratio, 1.27 [95% CI, 0.72-2.25]). The rate of acute kidney failure was lower following ViV, (RR, 0.54 [95% CI, 0.33-0.88], =0.02), whereas prosthetic aortic valve regurgitation (RR, 4.18 [95% CI, 1.88-9.3], =0.003) as well as severe patient-prothesis mismatch (RR, 3.12 [95% CI, 2.35-4.1], <0.001) occurred more frequently. The mean transvalvular gradient was higher following ViV (standard mean difference, 0.44 [95% CI, 0.15-0.72], =0.008). There were no significant differences between groups with respect to stroke (=0.26), myocardial infarction (=0.93), or pacemaker implantation (=0.21). Conclusions Results of this meta-analysis demonstrate better short-term mortality after ViV compared with rAVR. Midterm mortality was similar between groups. Given the likely selection bias in these individual reports, an adequately powered multicenter randomized clinical trial with sufficiently long follow-up in patients with low-to-intermediate surgical risk is warranted. Registration URL: crd.york.ac.uk/prospero/. Unique identifier: CRD42021228752.
Topics: Humans; Aortic Valve; Transcatheter Aortic Valve Replacement; Bioprosthesis; Reoperation; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Aortic Valve Stenosis; Aortic Valve Insufficiency; Myocardial Infarction; Stroke; Treatment Outcome; Risk Factors; Randomized Controlled Trials as Topic; Multicenter Studies as Topic
PubMed: 36533610
DOI: 10.1161/JAHA.121.024848 -
Journal of Cardiothoracic Surgery Mar 2024The Cabrol procedure has undergone various modifications and developments since its invention. However, there is a notable gap in the literature regarding meta-analyses... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The Cabrol procedure has undergone various modifications and developments since its invention. However, there is a notable gap in the literature regarding meta-analyses assessing it.
METHODS
A systematic review and meta-analysis was conducted to evaluate the effectiveness and long-term outcomes of the Cabrol procedure and its modifications. Pooling was conducted using random effects model. Outcome events were reported as linearized occurrence rates (percentage per patient-year) with 95% confidence intervals.
RESULTS
A total of 14 studies involving 833 patients (mean age: 50.8 years; 68.0% male) were included in this meta-analysis. The pooled all-cause early mortality was 9.0% (66 patients), and the combined rate of reoperation due to bleeding was 4.9% (17 patients). During the average 4.4-year follow-up (3,727.3 patient-years), the annual occurrence rates (linearized) for complications were as follows: 3.63% (2.79-4.73) for late mortality, 0.64% (0.35-1.16) for aortic root reoperation, 0.57% (0.25-1.31) for hemorrhage events, 0.66% (0.16-2.74) for thromboembolism, 0.60% (0.29-1.26) for endocarditis, 2.32% (1.04-5.16) for major valve-related adverse events, and 0.58% (0.34-1.00) for Cabrol-related coronary graft complications.
CONCLUSION
This systematic review provides evidence that the outcomes of the Cabrol procedure and its modifications are acceptable in terms of mortality, reoperation, anticoagulation, and valve-related complications, especially in Cabrol-related coronary graft complications. Notably, the majority of Cabrol procedures were performed in reoperations and complex cases. Furthermore, the design and anastomosis of the Dacron interposition graft for coronary reimplantation, considering natural anatomy and physiological hemodynamics, may promise future advancements in this field.
Topics: Humans; Male; Middle Aged; Female; Blood Vessel Prosthesis; Aortic Valve; Aorta; Heart Valve Prosthesis; Reoperation; Heart Diseases
PubMed: 38532449
DOI: 10.1186/s13019-024-02642-w -
Cardiology and Therapy Jun 2023We aimed to systematically analyze the literature on the use of transcatheter aortic valve replacement (TAVR) to treat active aortic valve infective endocarditis... (Review)
Review
We aimed to systematically analyze the literature on the use of transcatheter aortic valve replacement (TAVR) to treat active aortic valve infective endocarditis (AV-IE). Surgery is declined in one-third of patients with IE who meet indications because of prohibitive surgical risk. TAVR might be an alternative for selected patients with AV-IE as a bridge-to-surgery or stand-alone therapy. PubMed/MEDLINE, Embase, and Cochrane databases were searched (2002-2022) for studies on TAVR use in active AV-IE. Of 450 identified reports, six met inclusion criteria (all men, mean age 71 ± 12 years, median Society of Thoracic Surgeons (STS) score 27, EuroSCORE 56). All patients were prohibitive surgical risk candidates. Five out of six patients had severe, and one patient had moderate aortic regurgitation on presentation. Five out of six patients had prosthetic valve endocarditis after surgical valve replacement 13 years before (median), and one patient had TAVR a year before hospitalization. All patients had cardiogenic shock as the indication for TAVR. Four patients received balloon-expanding, and two patients received self-expanding TAVR after a median of 19 (IQR 9-25) days from diagnosis of IE. No death or myocardial infarction occurred, but one patient had a stroke within the first 30 days. The median event-free time was 9 (IQR 6-14) months including no death, reinfection, relapse IE, or valve-related rehospitalization. Our review suggests that TAVR can be considered as an adjuvant therapy to medical treatment for selected patients in whom surgery is indicated for treatment of acute heart failure due to aortic valve destruction and incompetence caused by infective endocarditis, but who have a prohibitive surgical risk. Nonetheless, a well-designed prospective registry is urgently needed to investigate the outcomes of TAVR for this off-label indication. No evidence exists for using the TAVR to treat infection-related surgical indications such as uncontrolled infection or control of septic embolization.
PubMed: 37079182
DOI: 10.1007/s40119-023-00314-9 -
Anatolian Journal of Cardiology Nov 2023Perfect heart valve prostheses have optimized hemodynamics, reduced surgical morbidity, long-lasting durability, and extended patient survival with greater quality of... (Review)
Review
BACKGROUND
Perfect heart valve prostheses have optimized hemodynamics, reduced surgical morbidity, long-lasting durability, and extended patient survival with greater quality of life. Mechanical valves are recommended; however, young children may need anticoagulant medication for life. In this study, we looked at the success rate and viability of aortic valve neocuspidization (AVNeo) surgery for a variety of aortic disorders.
METHODS
A methodical search strategy was used to fully evaluate the AVNeo results. Boolean operators were used to combine important words like 'Ozaki Procedure,' 'Aortic Valve Neocuspidization,' 'AVNeo,' and associated terms. Reputable databases such as PubMed, MEDLINE, Embase, Web of Science, and Scopus were the focus of our search. Study quality was assessed using a critical evaluation created with the Critical Appraisal Skills Programme tool.
RESULTS
The findings are summarized in the 'Results' section that contains descriptive and critical analysis, ramifications, and explanations. According to research, AVNeo improved valve function and had few side effects. Aortic valve neocuspidization has a lower mean pressure gradient and a larger mean efficient orifice area than Trifecta. Aortic valve neocuspidization surgery reduces aortic valve regurgitation and pressure gradients. Postoperative echocardiograms indicated a decrease in peak and a rise in mean pressure gradient.
CONCLUSION
The Ozaki method restores a healthy laminar flow pattern while preventing bivalvular disease. Ozaki procedure should be explored for valve repair in infants with truncal valve and congenital aortic disease. Aortic valve tricuspidization with glutaraldehyde-treated autologous pericardium results in considerable effective orifice area, modest pressure gradients, and little regurgitation.
Topics: Child; Humans; Child, Preschool; Aortic Valve; Quality of Life; Aortic Valve Stenosis; Aortic Valve Insufficiency; Heart Valve Prosthesis; Pericardium; Aortic Diseases; Treatment Outcome
PubMed: 37909351
DOI: 10.14744/AnatolJCardiol.2023.3477