The Journal of Thoracic and... Nov 2021Recent high-resolution computed tomography studies after transcatheter aortic valve insertion (TAVI) have reported a high prevalence of subclinical valve thrombosis... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Recent high-resolution computed tomography studies after transcatheter aortic valve insertion (TAVI) have reported a high prevalence of subclinical valve thrombosis (SCVT), potentially contributing to increased risk of late stroke. We aimed to investigate SCVT in patients after TAVI, with a focus on prevalence, predisposing factors, management, and potential sequelae.
METHODS
A comprehensive literature review of patients with SCVT after TAVI was carried out on all published studies in 3 major electronic databases from their inception until October 2019. Studies with sufficient data were included in a meta-analysis comparing the risk of stroke between patients with SCVT and those with normal valve function, as well as the protective effects of antiplatelet and anticoagulation on preventing SCVT.
RESULTS
From 3456 patients examined in a comprehensive review, 398 patients (11.5%) demonstrated evidence of SCVT during follow-up. Dual antiplatelet therapy was given in 45.5% of cases, single antiplatelet therapy in 19.8%, and oral anticoagulation in 28.5%. A meta-analysis demonstrated that rates of stroke were more than 3 times greater in patients with SCVT compared with those without (logistic odds, 1.10; 95% confidence interval, 0.63-1.57, P < .0001). Oral anticoagulation was superior to dual antiplatelet therapy or single antiplatelet therapy, preventing the formation of SCVT (logistic odds, -1.05, 95% confidence interval, -1.71 to -0.39, P < .0001).
CONCLUSIONS
Subclinical valve thrombosis is seen in 11.5% of patients after TAVI and is associated with increased risk of stroke. When oral anticoagulation is used postprocedurally, it is more effective than either dual or single-antiplatelet therapy in preventing subclinical valve thrombosis. These findings suggest that further studies are needed to define the optimal antithrombotic regimen to mitigate thrombotic and embolic sequelae after TAVI.
Topics: Aged; Aged, 80 and over; Anticoagulants; Aortic Valve; Asymptomatic Diseases; Female; Fibrinolytic Agents; Heart Valve Prosthesis; Humans; Male; Middle Aged; Platelet Aggregation Inhibitors; Risk Assessment; Risk Factors; Stroke; Thrombosis; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 32217021
DOI: 10.1016/j.jtcvs.2020.01.084 -
Infection Oct 2023Progress of interventional cardiology has boosted the use of newer cardiac devices. These devices are perceived to be less prone to infections compared to traditional... (Review)
Review
PURPOSE
Progress of interventional cardiology has boosted the use of newer cardiac devices. These devices are perceived to be less prone to infections compared to traditional surgical prostheses, but little data are currently available. In this systematic review (SR), we summarize current literature regarding the clinical characteristics, management, and outcomes of patients with MitraClip-related infective endocarditis (IE).
METHODS
We conducted a SR of PubMed, Google Scholar, Embase, and Scopus between January 2003 and March 2022. MitraClip-related IE was defined according to 2015 ESC criteria whereas MitraClip involvement as vegetation on the device or on the mitral valve. Risk of bias was assessed through standardized checklist and potential bias of underestimation cannot be excluded. Data regarding clinical presentation, echocardiography, management, and outcome were collected.
RESULTS
Twenty-six cases of MitraClip-related IE were retrieved. The median age of patients was 76 [61-83] years with a median EuroScore of 41%. Fever was present in 65.8% of patients followed by signs and symptoms of heart failure (42.3%). IE occurred early in 20 (76.9%) cases with a median time between MitraClip implantation and IE symptom onset of 5 [2-16] months. Staphylococcus aureus was the major causative microorganism (46%). Surgical mitral valve replacement was needed in 50% of patients. A conservative medical approach was considered in the remainder. The overall in-hospital mortality rate was 50% (surgical group: 38.4%; medical group: 58.3%; p = 0.433).
CONCLUSION
Our results suggest that MitraClip-related IE affects elderly, comorbid patients, is mostly due to Staphylococcus aureus, and has a poor prognosis irrespective of the therapeutic approach. Clinicians must be aware of the features of this new entity among cardiovascular infections.
Topics: Humans; Aged; Middle Aged; Aged, 80 and over; Heart Valve Prosthesis; Treatment Outcome; Endocarditis, Bacterial; Endocarditis; Mitral Valve; Mitral Valve Insufficiency
PubMed: 37386329
DOI: 10.1007/s15010-023-02067-y -
Procedural safety of transcatheter aortic valve replacement with Portico valve: a systematic review.International Journal of Surgery... Nov 2023The Portico transcatheter aortic heart valve is a self-expandable, fully resheathable bioprosthetic valve with a nitinol frame and porcine pericardial sealing cuff. It...
BACKGROUND
The Portico transcatheter aortic heart valve is a self-expandable, fully resheathable bioprosthetic valve with a nitinol frame and porcine pericardial sealing cuff. It has been used among symptomatic severe aortic stenosis (AS) who are at high or extreme surgical risk. However, till date very few studies has been reported with inconclusive evidence for its postprocedure safety outcomes.
OBJECTIVE
The authors aim to evaluate the safety of the Portico transcatheter aortic valve replacement system among patients with AS.
METHODOLOGY
The authors conducted a systematic literature search on PubMed, Embase, and Scopus from inception till 10th April 2023 by using predefined MESH terms using 'AND' and 'OR'. The following search terms were used: 'Aortic Stenosis' AND 'Transcatheter aortic valve replacement' OR 'Portico valve'. Finally, descriptive statistics were used to summarize the data in this paper. The mean and SD were adopted to describe continuous variables, whereas frequencies and percentages were used for dichotomous data.
RESULTS
A total of 7 studies with 2782 patients were included in the analysis. The mean age of patients was 82.3 years, and 54.63% were female. The most common comorbidity was hypertension (65.21%) and diabetes mellitus (26.45%). Among patients of AS with Portico valve implants, postprocedural outcomes including 30-day mortality (2.32%), cardiovascular mortality (2.37%), stroke (2.23%), myocardial infarction (0.94%), major bleeding (3.97%), major vascular complications (4.91%), acute kidney injury (1.37%), and permanent pacemaker implantations in 15.73% patients were reported. Overall, device success was observed in 95.82% of patients.
CONCLUSION
Transcatheter aortic valve replacement with the repositionable Portico valve, a new bioprosthesis, appears to have a low postprocedural mortality rate and other clinical outcomes in high-risk patients with severe AS.
Topics: Humans; Female; Animals; Swine; Aged, 80 and over; Male; Transcatheter Aortic Valve Replacement; Aortic Valve; Treatment Outcome; Postoperative Complications; Aortic Valve Stenosis; Heart Valve Prosthesis; Prosthesis Design
PubMed: 37581642
DOI: 10.1097/JS9.0000000000000645 -
Journal of Cardiovascular Imaging Apr 2023Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement...
BACKGROUND
Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning.
METHODS
We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI).
RESULTS
We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols.
CONCLUSIONS
This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.
PubMed: 37096677
DOI: 10.4250/jcvi.2022.0108 -
Journal of Interventional Cardiology Jun 2017The aim of this study was to perform a meta-analysis to compare the outcomes of patients undergoing TAVR with and without balloon post-dilation (PD). (Review)
Review
OBJECTIVES
The aim of this study was to perform a meta-analysis to compare the outcomes of patients undergoing TAVR with and without balloon post-dilation (PD).
BACKGROUND
PD is a commonly used technique in TAVR to minimize paravalvular regurgitation (PVR), albeit supported by little evidence.
METHODS
Systematic review and meta-analysis of 6 studies comparing 889 patients who had PD compared to 4118 patients without PD.
RESULTS
Patients undergoing PD were more likely male (OR 1.92; 95% CI, 1.41-2.61; P < 0.001) and to have coronary artery disease (OR 1.31; 95% CI, 1.03-1.68; P = 0.03) than those patients not requiring PD. There were no significant differences in 30-day mortality (OR 1.24; 95% CI, 0.88-1.74; P = 0.22) and myocardial infarction (OR 0.93; 95% CI, 0.46-1.90; P = 0.85). Patients undergoing TAVR did not have higher 1-year mortality rates (OR 0.98; 95% CI, 0.61-1.56; P = 0.92). The incidence of stroke was significantly greater in patients with PD (OR, 1.71; 95% CI, 1.10-2.66). PD was able to reduce the incidence of moderate-severe PVR by 15 fold (OR 15.0; 95% CI, 4.2-54.5; P < 0.001), although rates of moderate-severe PVR were still higher after PD than patients who did not require PD (OR 3.64; 95% CI, 1.96-6.75; P < 0.001).
CONCLUSIONS
PD significantly improves rates of PVR, however careful patient selection is needed to minimize increased risk of strokes.
Topics: Aortic Valve Insufficiency; Aortic Valve Stenosis; Balloon Valvuloplasty; Heart Valve Prosthesis Implantation; Humans; Incidence; Outcome Assessment, Health Care; Postoperative Complications; Risk Factors; Transcatheter Aortic Valve Replacement
PubMed: 28321917
DOI: 10.1111/joic.12378 -
ESC Heart Failure Oct 2022Aortic stenosis (AS) and cardiac amyloidosis (CA) are typical diseases of the elderly. Up to 16% of older adults with severe AS referred to transcatheter aortic valve... (Meta-Analysis)
Meta-Analysis
AIMS
Aortic stenosis (AS) and cardiac amyloidosis (CA) are typical diseases of the elderly. Up to 16% of older adults with severe AS referred to transcatheter aortic valve replacement (TAVR) have a concomitant diagnosis of CA. CA-AS population suffers from reduced functional capacity and worse prognosis than AS patients. As the prognostic impact of TAVR in patients with CA-AS has been historically questioned and in light of recently published evidence, we aim to provide a comprehensive synthesis of the efficacy and safety of TAVR in CA-AS patients.
METHODS AND RESULTS
We performed a systematic review and meta-analysis of studies: (i) evaluating mortality with TAVR as compared with medical therapy in CA-AS patients and (ii) reporting complications and clinical outcomes of TAVR in CA-AS patients as compared with patients with AS alone. A total of seven observational studies were identified: four reported mortality with TAVR, and four reported complications and clinical outcomes after TAVR of patients with CA-AS compared with AS alone patients. In patients with CA-AS, the risk of mortality was lower with TAVR (n = 44) as compared with medical therapy (n = 36) [odds ratio (OR) 0.23, 95% confidence interval (CI) 0.07-0.73, I = 0%, P = 0.001, number needed to treat = 3]. The safety profile of TAVR seems to be similar in patients with CA-AS (n = 75) as compared with those with AS alone (n = 536), with comparable risks of stroke, vascular complications, life-threatening bleeding, acute kidney injury, and 30 day mortality, although CA-AS was associated with a trend towards an increased risk of permanent pacemaker implantation (OR 1.76, 95% CI 0.91-4.09, I = 0%, P = 0.085). CA is associated with a numerically higher rate of long-term mortality and rehospitalizations following TAVR in patients with CA-AS as compared with those with AS alone.
CONCLUSIONS
TAVR is an effective and safe procedure in CA-AS patients, with a substantial survival benefit as compared with medical therapy, and a safety profile comparable with patients with AS alone except for a trend towards higher risk of permanent pacemaker implantation.
Topics: Humans; Aged; Transcatheter Aortic Valve Replacement; Aortic Valve; Heart Valve Prosthesis Implantation; Risk Factors; Aortic Valve Stenosis; Amyloidosis
PubMed: 35770333
DOI: 10.1002/ehf2.13876 -
Journal of Cardiothoracic Surgery Nov 2016Transcatheter aortic valve implantation (TAVI) has been adopted rapidly in Europe. TAVI national registries can augment understanding of technologies and represent... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
Transcatheter aortic valve implantation (TAVI) has been adopted rapidly in Europe. TAVI national registries can augment understanding of technologies and represent real-world experience, providing further clinical insights. We undertook a meta-analysis of published European national TAVI registries to assess current results following TAVI in Europe.
METHODS
Electronic databases were searched. The review focused on the comparison of the following TAVI strategies: transfemoral (TF) and transapical (TA) SAPIEN and CoreValve implantation. Individual event rates for outcomes of interest were pooled using a mixed effect model.
RESULTS
Seven European national TAVI registries (UK, Swiss, Belgium, Italy, Spain, France, Germany) were identified, including a total of 9786 patients who received TF-SAPIEN (n = 2885), TA-SAPIEN (n = 2252) and CoreValve (n = 4649) implantation. Pooled incidence of 30-day mortality was 0.08% [95% Confidence Interval (CI): 0.05-0.11], 0.12% [95% CI: 0.07-0.19] and 0.06% [95% CI: 0.03-0.11] for TF-SAPIEN, TA-SAPIEN and CoreValve respectively (test for subgroup difference P = 0.18); there was high heterogeneity across European countries. Pooled incidence of stroke was comparable among the TAVI strategies (test for subgroup difference P = 0.79); the incidence of post-procedural moderate paravalvular leak ≥ 2 (P = 0.9) was similar across groups. CoreValve implantation was associated with an increased risk of pacemaker implantation (0.22 [95% CI: 0.19-0.26]; test for subgroup difference P < 0.0001). The lowest 30-day mortality was associated with TAVI performed in Spain (b coefficient -4.3; P = 0.03), in Italy (b coefficient -2.1; P < 0.0001), in UK (b coefficient -1.95; P = 0.01) and in France (b coefficient -2.8; P = 0.03). The German registry has the highest mortality for every TAVI strategy amongst all other European registries and especially for the TA-SAPIEN group.
CONCLUSIONS
Transarterial TAVI approaches were associated with a low early mortality regardless of the type of device used. There was marked heterogeneity among European countries for early mortality.
Topics: Aortic Valve; Aortic Valve Stenosis; Europe; Heart Valve Prosthesis; Humans; Incidence; Pacemaker, Artificial; Registries; Stroke; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 27899128
DOI: 10.1186/s13019-016-0552-6 -
International Journal of Surgery... Aug 2023Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim... (Meta-Analysis)
Meta-Analysis
Comparisons of different new-generation transcatheter aortic valve implantation devices for patients with severe aortic stenosis: a systematic review and network meta-analysis.
BACKGROUND
Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim of the study was to compare the efficiency and safety of different new-generation TAVI devices for patients with aortic stenosis.
MATERIALS AND METHODS
A comprehensive search of PubMed, Embase and Web of Science from their inception to 1 February 2022. Randomized clinical trials and observational studies that compared two or more different TAVI devices were enroled. Pairwise meta-analysis and frequentist network meta-analysis were conducted to pool the outcome estimates of interest.
RESULTS
A total of 79 studies were finally included. According to the surface under the cumulative ranking, the top two ranked valves for lower rates of events were as follows: direct flow medical (DFM) (4.6%) and Lotus (48.8%) for lower rate of device success; Sapien 3 (16.8%) and DFM (19.7%) for lower mortality; DFM (8.6%) and Sapien 3 (25.5%) for lower rates of stroke; Evolut (27.6%) and DFM (35.8%) for lower rates of major and life-threatening bleeding; Portico (22.6%) and Sapien 3 (41.9%) for lower rates of acute kidney injury; Acurate (8.6%) and DFM (13.2%) for lower rates of permanent pacemaker implantation; Lotus (0.3%) and Sapien 3 (22.7%) for lower rates of paravalvular leak; Evolut (1.4%) and Portico (29.1%) for lower rates of mean aortic valve gradients.
CONCLUSIONS
The findings of the present study suggested that the device success rates were comparable among these new-generation valves except for DFM. After excluding DFM, Sapien 3 might be the best effective for decreased mortality and stroke; Lotus might be the best effective for decreased paravalvular leak; Evolut might be the best effective for decreased major and life-threatening bleeding and mean aortic valve gradients; Acurate and Portico might be the best effective for decreased permanent pacemaker implantation and acute kidney injury, respectively.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Network Meta-Analysis; Postoperative Complications; Treatment Outcome; Heart Valve Prosthesis; Prosthesis Design; Severity of Illness Index; Aortic Valve Stenosis; Stroke; Acute Kidney Injury
PubMed: 37161443
DOI: 10.1097/JS9.0000000000000456 -
Journal of the American Heart... Aug 2017Transcatheter pulmonary valve implantation is approved for the treatment of dysfunctional right ventricle to pulmonary artery conduits. However, the literature is... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Transcatheter pulmonary valve implantation is approved for the treatment of dysfunctional right ventricle to pulmonary artery conduits. However, the literature is limited because of a small patient population, and it does not reflect changing procedural practice patterns over the last decade.
METHODS AND RESULTS
A comprehensive search of Medline and Scopus databases from inception through August 31, 2016 was conducted using predefined criteria. We included studies reporting transcatheter pulmonary valve implantation in at least 5 patients with a follow-up duration of 6 months or more. In 19 eligible studies, 1044 patients underwent transcatheter pulmonary valve implantation with a pooled follow-up of 2271 person-years. Procedural success rate was 96.2% (95% confidence intervals [CI], 94.6-97.4) with a conduit rupture rate of 4.1% (95% CI, 2.5-6.8) and coronary complication rate of 1.3% (95% CI, 0.7-2.3). Incidence of reintervention was 4.4 per 100 person-years overall (95% CI, 3.0-5.9) with a marked reduction in studies reporting ≥75% prestenting (2.9 per 100 person-years [95% CI, 1.5-4.3] versus 6.5/100 person-years [95% CI, 4.6-8.5]; <0.01). Pooled endocarditis rate was 1.4 per 100 person-years (95% CI, 0.9-2.0).
CONCLUSIONS
Our study provides favorable updated estimates of procedural and follow-up outcomes after transcatheter pulmonary valve implantation. Widespread adoption of prestenting has improved longer-term outcomes in these patients.
Topics: Adolescent; Adult; Cardiac Catheterization; Child; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Observational Studies as Topic; Postoperative Complications; Pulmonary Valve; Risk Factors; Time Factors; Treatment Outcome; Young Adult
PubMed: 28778940
DOI: 10.1161/JAHA.117.006432 -
Clinical Cardiology Jul 2022Either a mechanical or bioprosthetic valve is used in patients undergoing mitral valve replacement (MVR). However, the optimal mitral prosthesis remains controversial.... (Meta-Analysis)
Meta-Analysis Review
Either a mechanical or bioprosthetic valve is used in patients undergoing mitral valve replacement (MVR). However, the optimal mitral prosthesis remains controversial. The aim of this meta-analysis was thus to compare outcomes between mechanical mitral valve replacement (MVRm) and bioprosthetic mitral valve replacement (MVRb) for MVR patients. We searched Embase, PubMed, Web of Science, and Cochrane Library databases from January 1, 2000 to October 31, 2021 for studies that directly compared surgical outcomes of MVRm and MVRb. A total of 22 studies with 35 903 patients were included in the meta-analysis (n = 23 868 MVRm and n = 12 035 MVRb). The MVRm group displayed lower long-term all causes mortality (HR, 0.84; 95% confidence interval [CI]: 0.77-0.91; p < .0001; I² = 51%), and fewer mitral reoperation (hazard ratio [HR]: 0.34; 95% CI: 0.23-0.50; p < .00001; I² = 74%) than MVRb group. However, the MVRm group was associated with a greater risk of major bleeding events (HR: 1.21; 95% CI: 1.14-1.29; p < .00001; I² = 0%), stroke and systemic embolism (HR: 1.20; 95% CI: 1.10-1.32; p < .0001; I² = 0%) in matched or adjusted data. No significant difference was observed between MVRm and MVRb on operative mortality in matched/adjusted group (risk ratios: 0.83; 95% CI: 0.66-1.05; p = .12; I² = 0%). The results were consistent with patients aged under 70 years old. Patients who received a MVRm is associated with 16% lower risk of long-term mortality and 66% lower risk of mitral reoperation, but 20% greater risk of stroke or systemic embolism, 21% greater risk of major bleeding compared with MVRb in matched/adjusted studies group, which were consistent to patients younger than the age of 70 years who underwent MVR.
Topics: Aged; Biological Products; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Hemorrhage; Humans; Mitral Valve; Reoperation; Retrospective Studies; Stroke; Treatment Outcome
PubMed: 35665516
DOI: 10.1002/clc.23854