Brazilian Oral Research Oct 2018Endodontic treatment is a common dental procedure used for treating teeth which the pulp tissue has become irreversibly inflamed or necrotic as a result of the carious... (Review)
Review
Endodontic treatment is a common dental procedure used for treating teeth which the pulp tissue has become irreversibly inflamed or necrotic as a result of the carious process or dental trauma. This procedure which involves mechanical and chemical preparation of root canal may affect several mechanical and physical properties of the tooth structure. The endodontic treatment can also influence the longevity of the rehabilitation of endodontically treated teeth and biomechanics during the oral function. For restoring endodontically treated teeth several factor and clinical decisions should be observed. The decision of the fiberglass post usage and the restorative materials are related to several factors such as the quantity and quality of remaining dental structure, presence of ferrule, post cementation length and final coronal restoration. In this review, the authors will address the effect of the endodontic treatment procedures on canal shape and mechanical properties of a tooth, and also discuss the parameters and the biomechanical principles of root canal treated teeth.
Topics: Biomechanical Phenomena; Dental Restoration, Permanent; Dental Stress Analysis; Dentin; Glass; Humans; Post and Core Technique; Root Canal Filling Materials; Root Canal Therapy; Tooth, Nonvital; Treatment Outcome
PubMed: 30365617
DOI: 10.1590/1807-3107bor-2018.vol32.0076 -
Journal of Oral Science 2018Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved... (Review)
Review
Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved substantially. This review discusses the accuracy of digital impression systems for fabrication of dental restorations and fixed dental prostheses. A literature search in PubMed was performed for the period from July 2010 through June 2017. The search keywords were Cerec, digital impression, direct digitalization, indirect digitalization, and intraoral scanner. Only relevant studies are summarized and discussed in this review. In general, the latest systems have considerably reduced the time required for impression making, and the accuracy and marginal fit of digital impression systems have recently improved. Restorations and fixed dental prostheses fabricated with currently available digital impression systems and intraoral scanners exhibit clinically acceptable ranges of marginal gap in both direct and indirect procedures.
Topics: Computer-Aided Design; Dental Impression Technique; Dental Prosthesis Design; Dental Restoration, Permanent; Humans; Mouth; Reproducibility of Results
PubMed: 29576569
DOI: 10.2334/josnusd.17-0444 -
Dental Materials Journal Jan 2020An optical-impression by an intraoral scanner (IOS) involves optically measuring the surface shape of the target teeth or gums directly in the patient's mouth. IOSs have...
An optical-impression by an intraoral scanner (IOS) involves optically measuring the surface shape of the target teeth or gums directly in the patient's mouth. IOSs have many advantages, such as reduce patients pain and discomfort, the operator's burden and the risk on infection, real-time impression scanning and visualization, simple replication and selective scanning, reduction of cost and waste of materials and detection of dental caries and crack . IOSs have become one of the most valuable dental-treatment devices for patients, dentists, dental technicians, and dental hygienists. The IOS accuracy matches or supersedes the accuracy of the conventional-impression and indirect method with working models. IOS is clinically applicable in restoration up to four units. IOS's high reproducibility, information-processing ability, multimedia capability, and simplicity and speed in communication can apply to group examination and identification of disaster victims or dementia patients.
Topics: Computer-Aided Design; Dental Caries; Dental Impression Technique; Dentistry; Humans; Imaging, Three-Dimensional; Models, Dental; Reproducibility of Results
PubMed: 31723066
DOI: 10.4012/dmj.2019-224 -
Brazilian Oral Research Aug 2017Polymerization shrinkage stress of resin-based materials have been related to several unwanted clinical consequences, such as enamel crack propagation, cusp deflection,... (Review)
Review
Polymerization shrinkage stress of resin-based materials have been related to several unwanted clinical consequences, such as enamel crack propagation, cusp deflection, marginal and internal gaps, and decreased bond strength. Despite the absence of strong evidence relating polymerization shrinkage to secondary caries or fracture of posterior teeth, shrinkage stress has been associated with post-operative sensitivity and marginal stain. The latter is often erroneously used as a criterion for replacement of composite restorations. Therefore, an indirect correlation can emerge between shrinkage stress and the longevity of composite restorations or resin-bonded ceramic restorations. The relationship between shrinkage and stress can be best studied in laboratory experiments and a combination of various methodologies. The objective of this review article is to discuss the concept and consequences of polymerization shrinkage and shrinkage stress of composite resins and resin cements. Literature relating to polymerization shrinkage and shrinkage stress generation, research methodologies, and contributing factors are selected and reviewed. Clinical techniques that could reduce shrinkage stress and new developments on low-shrink dental materials are also discussed.
Topics: Composite Resins; Curing Lights, Dental; Dental Stress Analysis; Materials Testing; Polymerization; Resin Cements
PubMed: 28902242
DOI: 10.1590/1807-3107BOR-2017.vol31.0062 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication...
PURPOSE
This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
STUDY SELECTION
We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported.
RESULTS
A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA.
CONCLUSION
The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Topics: Computer-Aided Design; Denture Bases; Denture, Partial, Removable; Humans; Tooth, Artificial; Workflow
PubMed: 33504722
DOI: 10.2186/jpr.JPR_D_20_00117 -
Head & Face Medicine Jul 2021Orthodontic retention aims to maintain optimal teeth positions after active treatment. The stability is affected by numerous factors, including patients' individual... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Orthodontic retention aims to maintain optimal teeth positions after active treatment. The stability is affected by numerous factors, including patients' individual features, thus retention should be adjusted in the most optimal way. Bonding a retainer makes retention less dependent on patient's compliance.
QUESTIONS ARISE
What wire or fiber splint type provides the best treatment stability? What materials should be used to bond the wire or fiber splint? Should be the bonding procedure be direct or indirect? The aim of the study is to assess and synthesize available controlled trials investigating failures of fixed retainers.
METHODS
Literature searches of free text and MeSH terms were performed in Scopus, Web of Science, Embase and PubMed Central in order to find studies, referring to failures of fixed retention (12th February 2021). The keywords were: ("orthodontic retainers AND failure AND wire"). The framework of this systematic review according to PICO was: Population: orthodontic patients; Intervention: fixed orthodontic retainer bonding; Comparison: Different protocols of fixed orthodontic retention applied; Outcomes: failure rate, survival rate. Three different specific scales from the Cochrane Collaboration Handbook were used, according to each study type. Additionally, a meta-analysis was conducted to compare the effectiveness of retention using fiber reinforced composite and multistranded steel wire.
RESULTS
The search identified 177 potential articles: 114 from PubMed, 41 from Scopus, 20 from Web of Science and 2 from Embase. After excluding studies inconsistent with selection criteria, 21 studies were included and subjected to qualitative analysis. The main outcome investigated was failure rate. This systematic review has some potential limitations due to the heterogeneity of design between included studies.
CONCLUSIONS
No retainer is proved to guarantee a perfect stability of dental alignment. The retainer should be bonded to all adherent teeth, preferably with additional use of bonding resin. No wire or fiber splint present superior characteristics concerning failure rate. Fiber reinforced composite retention is more sensitive to operator skills, and with imperfect bonding technique, failure rate is much higher. During the first 6 months after bonding retainer the patient should be under frequent control. The study protocol was registered in PROSPERO database with the number CRD42021233406.
Topics: Dental Bonding; Humans; Orthodontic Appliance Design; Orthodontic Retainers; Orthodontic Wires
PubMed: 34301280
DOI: 10.1186/s13005-021-00281-3 -
European Archives of Paediatric... Oct 2018This critical appraisal attempts to answer the question: What is the best method of space maintenance (SM) following premature loss of a primary molar in children under... (Review)
Review
AIM
This critical appraisal attempts to answer the question: What is the best method of space maintenance (SM) following premature loss of a primary molar in children under 12 years old?
METHODS
A search to identify studies relevant to the PICO was conducted. Single case reports and studies prior to 1986 were excluded. The principles of GRADE were followed to appraise the evidence.
RESULTS
20 studies were identified, which evaluated 2265 space maintainers (SMs). Two studies were graded high quality, four moderate, eight low, and six very low. All studies reported on longevity outcomes and most on adverse effects.
CONCLUSIONS
There was no strong evidence favouring a particular SM, the following recommendations were made: (a) strong recommendations: In cases where rubber dam cannot be used clinicians should not use Glass Fibre Reinforced Composite Resin (GFRCR) SMs. (b) Weak recommendations: Crown and Loop SMs are recommended for loss of primary first molars; GFRCR SMs (placed under rubber dam) are recommended for loss of primary second molars. Bilateral SMs may have questionable efficacy and their use where there is loss of multiple molars in the same quadrant should be weighed against the risk of unwanted tooth movements, loss of a removable SM or no space maintenance at all.
Topics: Child; Humans; Molar; Orthodontic Appliance Design; Orthodontic Appliances; Space Maintenance, Orthodontic; Tooth, Deciduous
PubMed: 30187262
DOI: 10.1007/s40368-018-0357-5 -
Journal of Esthetic and Restorative... Nov 2019The unavoidable extraction of teeth in the esthetic area can be overcome through different treatment modalities. Recently, immediate implants appeared as a minimally...
OBJECTIVE
The unavoidable extraction of teeth in the esthetic area can be overcome through different treatment modalities. Recently, immediate implants appeared as a minimally invasive approach to resolving these cases; however, immediate implant loading is not always possible or indicated. In these cases, an innovative approach through customized healing abutments could be used to preserve the soft tissue contour, eliminating the need for reopening surgery and the use of provisional restorations to condition the mucosal contour.
CLINICAL CONSIDERATIONS
The present cases describe a simplified chairside approach to use customized healing abutments for immediate implants placed after tooth extraction in the anterior and posterior areas in order to maintain the soft tissue contours while reducing the clinical steps until delivering the final restorations.
CONCLUSIONS
This technique seems to be effective to guide the soft tissue healing around dental implants allowing a natural emergence profile with implant-supported restorations, reducing the number of treatment steps.
CLINICAL SIGNIFICANCE
The use of customized healing abutments prepares soft tissue for the prosthetic stage preserving its contours and eliminating the need for reopening surgery.
Topics: Dental Abutments; Dental Implantation, Endosseous; Dental Implants; Dental Implants, Single-Tooth; Dental Prosthesis, Implant-Supported; Humans; Immediate Dental Implant Loading; Tooth Extraction
PubMed: 31268244
DOI: 10.1111/jerd.12512 -
Caries Research 2017
Topics: Consensus; Delphi Technique; Dental Caries; Dentistry; Humans; Publications
PubMed: 29040975
DOI: 10.1159/000480305 -
The Chinese Journal of Dental Research 2018
Topics: China; Dentistry; Health Status; Humans; Oral Health; Oral Medicine; Periodontics; Public Health; Societies, Dental
PubMed: 29507907
DOI: 10.3290/j.cjdr.a39998