-
BMC Oral Health Nov 2020The purpose of this paper is to review the available literature on three-dimensionally printed complete dentures in terms of novel biomaterials, fabrication techniques... (Review)
Review
BACKGROUND
The purpose of this paper is to review the available literature on three-dimensionally printed complete dentures in terms of novel biomaterials, fabrication techniques and workflow, clinical performance and patient satisfaction.
METHODS
The methodology included applying a search strategy, defining inclusion and exclusion criteria, selecting studies and forming tables to summarize the results. Searches of PubMed, Scopus, and Embase databases were performed independently by two reviewers to gather literature published between 2010 and 2020.
RESULTS
A total of 126 titles were obtained from the electronic database, and the application of exclusion criteria resulted in the identification of 21 articles pertaining to printed technology for complete dentures. Current innovations and developments in digital dentistry have successfully led to the fabrication of removable dental prostheses using CAD/CAM technologies. Milled dentures have been studied more than 3D printed ones in the currently available literature. The limited number of clinical studies, mainly case reports, suggest current indications of 3D printing in denture fabrication process to be custom tray, record bases, trial, interim or immediate dentures but not definitive prostheses fabrication. Limitations include poor esthetics and retention, inability to balance occlusion and low printer resolution.
CONCLUSIONS
Initial studies on digital dentures have shown promising short-term clinical performance, positive patient-related results and reasonable cost-effectiveness. 3D printing has potential to modernize and streamline the denture fabrication techniques, materials and workflows. However, more research is required on the existing and developing materials and printers to allow for advancement and increase its application in removable prosthodontics.
Topics: Computer-Aided Design; Denture, Complete; Esthetics, Dental; Humans; Printing, Three-Dimensional; Workflow
PubMed: 33246466
DOI: 10.1186/s12903-020-01328-8 -
Primary Dental Journal Sep 2020Improvements in oral health including increased retention of natural teeth have given rise to a partially dentate older population. Replacement of missing natural teeth...
Improvements in oral health including increased retention of natural teeth have given rise to a partially dentate older population. Replacement of missing natural teeth is important to improve function, aesthetics and quality of life for this patient group. A variety of options are available to replace missing teeth in partially dentate older adults, including fixed, removable and implant retained prostheses. This article will discuss the provision of removable partial dentures including treatment planning and denture design. When planning removable partial dentures, careful attention must be paid to stabilising the patient prior to delivering any prosthesis. Partial dentures should be designed to minimise the potential for plaque accumulation with carefully designed metal based frameworks. Acrylic resin can also be utilised with attention to detail to minimise the risk of damage to delicate supporting tissues. Removable dentures have the advantage that they can be readily added to in the event of further tooth loss which may be particularly relevant for older adults. Partial dentures which optimise support, retention and stability can function very successfully and significantly improve patients' oral health related quality of life.
Topics: Aged; Denture, Partial; Denture, Partial, Removable; Humans; Mouth, Edentulous; Quality of Life; Tooth Loss
PubMed: 32940586
DOI: 10.1177/2050168420943435 -
The Cochrane Database of Systematic... Apr 2018Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life.
OBJECTIVES
To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people.
SEARCH METHODS
Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the same material and different techniques, or different materials and the same technique. In tooth- and tissue-supported RPD, we included trials comparing the same material and different dual-impression techniques, and different materials with different dual-impression techniques.
DATA COLLECTION AND ANALYSIS
Two review authors independently, and in duplicate, screened studies for eligibility, extracted data, and assessed the risk of bias for each included trial. We expressed results as risk ratios (RR) for dichotomous outcomes, and as mean differences (MD) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CI), using the random-effects model. We constructed 'Summary of findings' tables for the main comparisons and outcomes (participant-reported oral health-related quality of life, quality of the denture, and denture border adjustments).
MAIN RESULTS
We included nine studies in this review. Eight studies involved 485 participants with CD. We assessed six of the studies to be at high risk of bias, and two to be at low risk of bias. We judged one study on RPD with 72 randomised participants to be at high risk of bias.Overall, the quality of the evidence for each comparison and outcome was either low or very low, therefore, results should be interpreted with caution, as future research is likely to change the findings.Complete denturesTwo studies compared the same material and different techniques (one study contributed data to a secondary outcome only); two studies compared the same technique and different materials; and four studies compared different materials and techniques.One study (10 participants) evaluated two stage-two step, Biofunctional Prosthetic system (BPS) using additional silicone elastomer compared to conventional methods, and found no evidence of a clear difference for oral health-related quality of life, or quality of the dentures (denture satisfaction). The study reported that BPS required fewer adjustments. We assessed the quality of the evidence as very low.One study (27 participants) compared selective pressure final-impression technique using wax versus polysulfide elastomeric (rubber) material. The study did not measure quality of life or dentures, and found no evidence of a clear difference between interventions in the need for adjustments (RR 0.81, 95% CI 0.38 to 1.70). We assessed the quality of the evidence as very low.One study compared two stage-two step final impression with alginate versus silicone elastomer. Oral health-related quality of life measured by the OHIP-EDENT seemed to be better with silicone (MD 7.20, 95% CI 2.71 to 11.69; 144 participants). The study found no clear differences in participant-reported quality of the denture (comfort) after a two-week 'confirmation' period, but reported that silicone was better for stability and chewing efficiency. We assessed the quality of the evidence as low.Three studies compared single-stage impressions with alginate versus two stage-two step with elastomer (silicone, polysulfide, or polyether) impressions. There was no evidence of a clear difference in the OHIP-EDENT at one month (MD 0.05, 95% CI -2.37 to 2.47; two studies, 98 participants). There was no evidence of a clear difference in participant-rated general satisfaction with dentures at six months (MD 0.00, 95% CI -8.23 to 8.23; one study, 105 participants). We assessed the quality of the evidence as very low.One study compared single-stage alginate versus two stage-two step using zinc-oxide eugenol, and found no evidence of a clear difference in OHIP-EDENT (MD 0.50, 95% CI -2.67 to 3.67; 39 participants), or general satisfaction (RR 3.15, 95% CI 0.14 to 72.88; 39 participants) at six months. We assessed the quality of the evidence as very low.Removable partial denturesOne study randomised 72 participants and compared altered-cast technique versus one-piece cast technique. The study did not measure quality of life, but reported that most participants were satisfied with the dentures and there was no evidence of any clear difference between groups for general satisfaction at one-year follow-up (low-quality evidence). There was no evidence of a clear difference in number of intaglio adjustments at one year (RR 1.43, 95% CI 0.61 to 3.34) (very low-quality evidence).
AUTHORS' CONCLUSIONS
We conclude that there is no clear evidence that one technique or material has a substantial advantage over another for making complete dentures and removable partial dentures. Available evidence for the relative benefits of different denture fabrication techniques and final-impression materials is limited and is of low or very low quality. More high-quality RCTs are required.
Topics: Dental Impression Materials; Dental Impression Technique; Denture Design; Denture Retention; Denture, Partial, Removable; Dentures; Humans; Mouth, Edentulous; Quality of Life; Randomized Controlled Trials as Topic
PubMed: 29617037
DOI: 10.1002/14651858.CD012256.pub2 -
Hua Xi Kou Qiang Yi Xue Za Zhi = Huaxi... Feb 2021Digital technologies use high-precision three-dimensional scanning, intelligence-aided design software, and multi-axis numerical control milling or 3D printing, which... (Review)
Review
Digital technologies use high-precision three-dimensional scanning, intelligence-aided design software, and multi-axis numerical control milling or 3D printing, which can produce restorations with reliable precision and suitable function. However, the development of digital technologies in the field of complete denture restoration has been slow due to the complexity of prosthesis. This review article introduces the current research status and clinical applications of digital complete dentures in prosthodontic clinics and dental laboratories to provide beneficial references to prosthodontists and dental technicians.
Topics: Computer-Aided Design; Denture, Complete; Printing, Three-Dimensional
PubMed: 33723930
DOI: 10.7518/hxkq.2021.01.001 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication...
PURPOSE
This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
STUDY SELECTION
We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported.
RESULTS
A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA.
CONCLUSION
The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Topics: Computer-Aided Design; Denture Bases; Denture, Partial, Removable; Humans; Tooth, Artificial; Workflow
PubMed: 33504722
DOI: 10.2186/jpr.JPR_D_20_00117 -
Journal of Oral Science Oct 2021The recent literature on maxillary implant overdenture (IOD) was reviewed in order to clarify its predictability and establish treatment guidelines. Electronic searches... (Review)
Review
The recent literature on maxillary implant overdenture (IOD) was reviewed in order to clarify its predictability and establish treatment guidelines. Electronic searches were performed using PubMed, and articles about maxillary IOD written after 1990 were reviewed, focusing on the following items: I. implant survival rate, II. maxillary IOD survival rate, III. number of implants, IV. attachment type, V. follow-up period, VI. implant system, and VII. opposing dentition. The review revealed an implant survival rate of 61-100% and an overdenture survival rate of 72.4-100%. The attachments used included bars, balls, locators, and telescope crowns. The minimum and maximum observation periods were 12 months and 120 months, respectively, and the number of implants used for supporting IOD ranged from 2 to 8. At present, there is no strong evidence to indicate that maxillary IOD is clearly superior for all the items examined. However, the existing data indicate that maxillary IOD has almost the same therapeutic effect as fixed implant superstructures, and is a treatment option that can be actively adopted for patients in whom fixed superstructures cannot be applied for various reasons.
Topics: Dental Implants; Dental Prosthesis, Implant-Supported; Denture Retention; Denture, Overlay; Humans; Maxilla
PubMed: 34408111
DOI: 10.2334/josnusd.21-0087 -
BioMed Research International 2021The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures... (Review)
Review
The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures (RPDs) and how to optimize it. A literature survey was conducted for the English full-text articles, which used only FEA to estimate the stress developed in RPDs from Jan 2000 to May 2021. In RPDs, the retaining and supporting structures are subjected to dynamic loads during insertion and removal of the prosthesis as well as during function. The majority of stresses in free-end saddle (FES) RPDs are concentrated in the shoulder of the clasp, the horizontal curvature of the gingival approaching clasp, and the part of the major connector next to terminal abutments. Clasps fabricated from flexible materials were beneficial to eliminate the stress in the abutment, while rigid materials were preferred for major connectors to eliminate the displacement of the prosthesis. In implant-assisted RPD, the implant receive the majority of the load, thereby reducing the stress on the abutment and reducing the displacement of the prosthesis. The amount of stress in the implant decreases with zero or minimal angulation, using long and wide implants, and when the implants are placed in the first molar area.
Topics: Algorithms; Biomechanical Phenomena; Dental Abutments; Dental Implants; Denture Design; Denture, Partial, Removable; Finite Element Analysis; Humans; Stress, Mechanical
PubMed: 34485518
DOI: 10.1155/2021/5699962 -
Clinical Oral Implants Research Feb 2016The aim of this systematic review was to analyze post-loading implant loss for implant-supported prostheses in edentulous jaws, regarding a potential impact of implant... (Review)
Review
OBJECTIVES
The aim of this systematic review was to analyze post-loading implant loss for implant-supported prostheses in edentulous jaws, regarding a potential impact of implant location (maxilla vs. mandible), implant number per patient, type of prosthesis (removable vs. fixed), and type of attachment system (screw-retained, ball vs. bar vs. telescopic crown).
MATERIAL AND METHODS
A systematic literature search for randomized-controlled trials (RCTs) or prospective studies was conducted within PubMed, Cochrane Library, and Embase. Quality assessment of the included studies was carried out, and the review was structured according to PRISMA. Implant loss and corresponding 3- and 5-year survival rates were estimated by means of a Poisson regression model with total exposure time as offset.
RESULTS
After title, abstract, and full-text screening, 54 studies were included for qualitative analyses. Estimated 5-year survival rates of implants were 97.9% [95% CI 97.4; 98.4] in the maxilla and 98.9% [95% CI 98.7; 99.1] in the mandible. Corresponding implant loss rates per 100 implant years were significantly higher in the maxilla (0.42 [95% CI 0.33; 0.53] vs. 0.22 [95% CI 0.17; 0.27]; P = 0.0001). Implant loss rates for fixed restorations were significantly lower compared to removable restorations (0.23 [95% CI 0.18; 0.29] vs. 0.35 [95% CI 0.28; 0.44]; P = 0.0148). Four implants and a fixed restoration in the mandible resulted in significantly higher implant loss rates compared to five or more implants with a fixed restoration. The analysis of one implant and a mandibular overdenture also revealed higher implant loss rates than an overdenture on two implants. The same (lower implant number = higher implant loss rate) applied when comparing 2 vs. 4 implants and a mandibular overdenture. Implant loss rates for maxillary overdentures on <4 implants were significantly higher than for four implants (7.22 [95% CI 5.41; 9.64] vs. 2.31 [1.56; 3.42]; P < 0.0001).
CONCLUSIONS
Implant location, type of restoration, and implant number do have an influence on the estimated implant loss rate. Consistent reporting of clinical studies is necessary and high-quality studies are needed to confirm the present results.
Topics: Dental Implantation, Endosseous; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Denture, Overlay; Denture, Partial, Fixed; Humans; Jaw, Edentulous
PubMed: 25664612
DOI: 10.1111/clr.12531 -
Acta Odontologica Latinoamericana : AOL Aug 2018Full edentulism is characterized by the complete loss of permanent teeth, resulting in aesthetic, structural and functional changes which can negatively impact quality... (Comparative Study)
Comparative Study
Full edentulism is characterized by the complete loss of permanent teeth, resulting in aesthetic, structural and functional changes which can negatively impact quality of life, and which are minimized through rehabilitation with complete dentures. The aim of this study was to compare oral healthrelated quality of life in patients with complete original dentures three months after installation of new dentures and two years after fabrication of new complete removable dentures. In this longitudinal comparative study, 15 volunteers of both genders, aged 50 to 82 years, who sought treatment at the Department of Dentistry of the Federal University of Rio Grande do Norte, participated in the preparation of new dentures. The Brazilian version of the Oral Health Impact Profile for edentulous patients (OHIPEDENT) was used to evaluate quality of life. Data analysis was performed descriptively and with hypothesis testing using the Friedman and Wilcoxon tests with 5% significance level. In relation to the OHIPEDENT domains, there was a difference for chewing discomfort and inability to chew between baseline and two years. However, there was no difference between the evaluated periods in the areas of pain and orofacial muscle discomfort, psychological inability and social disability. Improvement indicators in patient quality of life were observed in the area of discomfort and inability to chew between baseline and 2 years.
Topics: Aged; Aged, 80 and over; Denture, Complete; Female; Humans; Longitudinal Studies; Male; Middle Aged; Quality of Life
PubMed: 30383072
DOI: No ID Found -
International Journal of Implant... Nov 2021Implant-assisted removable partial dentures (IARPDs) have recently become popular, but little information is available on the treatment outcomes based on the Kennedy... (Review)
Review
BACKGROUND
Implant-assisted removable partial dentures (IARPDs) have recently become popular, but little information is available on the treatment outcomes based on the Kennedy classification and attachment types.
OBJECTIVE
The objective of this review was to evaluate the treatment outcomes of IARPD delivered for distal extension edentulous areas based on the differences in the Kennedy classification and attachment type.
MATERIALS AND METHODS
English-language clinical studies on IARPD published between January 1980 and February 2020 were collected from MEDLINE (via PubMed), the Cochrane Library (via the Cochrane Central Register of Controlled Trials), Scopus online database, and manual searching. Two reviewers selected the articles based on pre-determined inclusion and exclusion criteria, followed by data extraction and analysis.
RESULTS
Eighty-one studies were selected after evaluating the titles and abstracts of 2410 papers. Nineteen studies were finally included after the perusal of the full text. Fourteen studies focused on Class I, 4 studies investigated both Class I and II, and only 1 study was conducted on Kennedy's class II. Eight types of attachments were reported. The ball attachment was the most frequently used attachment, which was employed in 8 of the included studies. The implant survival rate ranged from 91 to 100%. The reported marginal bone loss ranged from 0.3 mm to 2.30 mm. The patient satisfaction was higher with IARPD than with conventional RPDs or that before treatment. The results of prosthetic complications were heterogeneous and inconclusive.
CONCLUSION
IARPD exhibited favorable clinical outcomes when used as a replacement for distal extension edentulous areas. The comparison between the clinical outcomes of Kennedy's class I and II was inconclusive owing to the lack of studies focusing on Kennedy Class II alone. The stud attachment was the most commonly used type in IARPDs. Overall, the different attachment systems did not influence the implant survival rate and patient satisfaction. Further high-quality studies are needed to investigate the attachment systems used in IARPD.
Topics: Dental Implants; Dental Prosthesis, Implant-Supported; Denture, Partial, Removable; Humans; Patient Satisfaction; Treatment Outcome
PubMed: 34773513
DOI: 10.1186/s40729-021-00394-z