Journal of Pediatric Gastroenterology... Feb 2021Pediatric high-resolution manometry (HRM) and 24-hour pH-impedance with/without ambulatory manometry (pH-MII+/-mano) tests are generally performed using adult-derived...
OBJECTIVES
Pediatric high-resolution manometry (HRM) and 24-hour pH-impedance with/without ambulatory manometry (pH-MII+/-mano) tests are generally performed using adult-derived protocols. We aimed to assess the feasibility of these protocols in children, the occurrence of patient-related imperfections and their influence on test interpretability.
METHODS
Esophageal function tests performed between 2015 and 2018 were retrospectively analyzed. All tests were subcategorized into uninterpretable or interpretable tests (regardless of occurrence of patient-related imperfections). For HRM, the following patient-related imperfections were scored: patient-related artefacts, multiple swallowing and/or inability to establish baseline characteristics. For pH-MII(+/-mano), incorrect symptom registration and/or premature catheter removal were scored. Results were compared between age-groups (0-3, 4-12, and >12 years).
RESULTS
In total 106 HRM, 60 pH-MII, and 23 pH-MII-mano could be fully analyzed. Of these, 94.8% HRM, 91.9% pH-MII, and 95.7% pH-MII-mano were interpretable. Overall, HRM contained imperfections in 78.3% overall and in 8/8 (100%) in the youngest age group, 36/42 (85.7%) in 4 to 12 years and in 37/56 (66.1%) in children above 12 years; P = 0.011. These imperfections led to uninterpretable results in 4 HRM (3.8%), of which 3 were in the youngest age group (3/8, 37.5%). Imperfections were found in 10% of pH-MII and 17.4% of pH-MII-mano. These led to uninterpretable results in 5.0% and 4.3%, respectively. No age-effect was found.
CONCLUSIONS
Esophageal function tests in children are interpretable in more than 90% overall. In children under the age of 4 years, all patients had imperfect HRM and 3/8 tests were uninterpretable. HRM in older children and pH-MII+/-mano were interpretable in the vast majority.
Topics: Adult; Child; Child, Preschool; Electric Impedance; Esophageal pH Monitoring; Gastroesophageal Reflux; Humans; Manometry; Retrospective Studies
PubMed: 33230070
DOI: 10.1097/MPG.0000000000003000 -
Neurogastroenterology and Motility Jan 2023Minute rhythm and prolonged simultaneous contractions are patterns of postprandial small bowel contractile activity that historically have been considered as suggestive...
INTRODUCTION
Minute rhythm and prolonged simultaneous contractions are patterns of postprandial small bowel contractile activity that historically have been considered as suggestive of mechanical intestinal obstruction; however, these patterns have been also encountered in patients with motility-like symptoms in the absence of bowel obstruction. The objective of this study was to determine the current diagnostic outcome of patients with these intestinal manometry patterns.
METHODS
Retrospective study of patients with chronic digestive symptoms evaluated by intestinal manometry at our center between 2010 and 2018.
RESULTS
The minute rhythm (MRP) or prolonged simultaneous contractions (PSC) postprandial patterns were detected in 61 of 488 patients (55 MRP and 6 PSC). Clinical work-up detected a previously non-diagnosed partial mechanical obstruction of the distal intestine in 10 (16%) and a systemic disorder causing intestinal neuropathy in 32 (53%). In the remaining 19 patients (31%, all with MRP), the origin of the contractile pattern was undetermined, but in 16, substantial fecal retention was detected within 7 days of the manometric procedure by abdominal imaging, and in 6 of them colonic cleansing completely normalized intestinal motility on a second manometry performed within 39 ± 30 days.
CONCLUSION AND INFERENCE
Currently, the most frequent origin of MRP and PSC encountered on small bowel manometry is intestinal neuropathy, while a previously undetected mechanical obstruction is rare. Still, in a substantial proportion of patients, no underlying disease can be identified, and in them, colonic fecal retention might play a role, because in a subgroup of these patients, manometry normalized after colonic cleansing. Hence, colonic preparation may be considered prior to intestinal manometry.
Topics: Humans; Retrospective Studies; Clinical Relevance; Intestinal Obstruction; Intestine, Small; Gastrointestinal Motility; Manometry
PubMed: 36102622
DOI: 10.1111/nmo.14462 -
United European Gastroenterology Journal Feb 2020
Topics: Esophageal Achalasia; Esophagoscopy; Humans; Manometry; Reference Standards
PubMed: 32213047
DOI: 10.1177/2050640620902570 -
American Journal of Physiology.... Jan 2021Motility of the large bowel may be grossly subdivided in two types of contractile activity: low-amplitude single or cyclic propagated waves and high-amplitude propagated... (Review)
Review
Motility of the large bowel may be grossly subdivided in two types of contractile activity: low-amplitude single or cyclic propagated waves and high-amplitude propagated activity. The latter is mainly apt to shift relatively large amounts of colonic contents, and it is related to defecation. The main component of this propagated activity is represented by the radiologically identified mass movements that have a manometric equivalent known as high-amplitude propagated contractions (HAPC). The present article reviews origins and characterization of HAPC in the time course of colonic motility investigations, and correlates it with technological advancements in recent years, putting into perspective the future possible options to better detect and investigate these important physiological events.
Topics: Colon; Colonic Neoplasms; Gastrointestinal Motility; Humans; Manometry; Muscle Contraction
PubMed: 33174455
DOI: 10.1152/ajpgi.00375.2020 -
European Review For Medical and... Sep 2022Esophageal motility is regulated both by coordinated stimulation and inhibition of the circular and longitudinal muscle layers of the esophagus. Although there are many...
OBJECTIVE
Esophageal motility is regulated both by coordinated stimulation and inhibition of the circular and longitudinal muscle layers of the esophagus. Although there are many diseases known to have an effect on esophageal motility, the effect of subepithelial lesions (SELs) of the esophagus on esophageal motility, which is often detected incidentally, remains still unclear. The aim of this study is to reveal the effect of SELs of the esophagus on esophageal motility evaluating it by high-resolution manometry (HRM).
PATIENTS AND METHODS
A total of 32 patients with SELs in the esophagus and 12 healthy individuals were included. All patients and controls included in the study underwent HRM using a Unisensor UniTip High Resolution catheter (Laborie, Amsterdam, Netherlands) and endosonographic examination.
RESULTS
The mean age was 52.60±15.56 years (range: 23-79) and the average body mass index (BMI) was 26.63±4.71 kg/m2. Gender, height, weight, and BMI measurements, smoking status, alcohol use, and DM status did not statistically differ significantly between the groups (p>0.05). Of 32 patients with SELs, 65.6% (n=21) had lesions originating in the muscularis propria, while 34.4% had lesions originating in the submucosa. The rate of abnormal motility both in the supine and in upright positions of patients with SELs was found to be significantly higher than in the control group (p=0.001, p<0.01, respectively). In patients with SELs, the incidence of infective motility was higher than the normal group (p=0.001, p<0.01, respectively). As the size of the lesion increases (>2 cm), the probability of abnormal HRM results increased.
CONCLUSIONS
SELs of the esophagus have pathological effects on esophageal motility, mainly ineffective esophageal motility disorder.
Topics: Adult; Aged; Endosonography; Esophageal Motility Disorders; Humans; Manometry; Middle Aged; Radionuclide Imaging
PubMed: 36111931
DOI: 10.26355/eurrev_202209_29654 -
Dysphagia Oct 2019The pharynx is critical for correct swallowing, facilitating the transport of both air and food transport in a highly coordinated manner, and aberrant co-ordination...
The pharynx is critical for correct swallowing, facilitating the transport of both air and food transport in a highly coordinated manner, and aberrant co-ordination causes swallowing disorders (dysphagia). In this work, an in vitro model of swallowing was designed to investigate the role of rheology in swallowing and for use as a pre-clinical tool for simulation of different routes to dysphagia. The model is based on the geometry of the human pharynx. Manometry is used for pressure measurements and ultrasonic analysis is performed to analyze the flow profiles and determine shear rate in the bolus, the latter being vital information largely missing in literature. In the fully automated model, bolus injection, epiglottis/nasopharynx movement, and ultrasound transducer positioning can be controlled. Simulation of closing of the airways and nasal cavity is modulated by the software, as is a clamping valve that simulates the upper esophageal sphincter. The actions can be timed and valves opened to different degrees, resembling pathologic swallowing conditions. To validate measurements of the velocity profile and manometry, continuous and bolus flow was performed. The respective velocity profiles demonstrated the accuracy and validity of the flow characterization necessary for determining bolus flow. A maximum bolus shear rate of 80 s was noted for syrup-consistency fluids. Similarly, the manometry data acquired compared very well with clinical studies.
Topics: Deglutition; Humans; Manometry; Models, Biological; Pharynx; Pressure; Rheology
PubMed: 30673839
DOI: 10.1007/s00455-018-09969-2 -
Abdominal Radiology (New York) Jan 2022Double contrast barium esophagography (BAS) and high-resolution manometry (HRM) are traditionally performed on separate days to allow for pre-procedural fasting. In an...
PURPOSE
Double contrast barium esophagography (BAS) and high-resolution manometry (HRM) are traditionally performed on separate days to allow for pre-procedural fasting. In an effort to minimize COVID-19 exposure and improve appointment efficiency with required pre-procedure testing, we permitted same day HRM prior to BAS. Our study aimed to evaluate the adequacy of barium mucosal coating with same day HRM prior to BAS compared to BAS alone.
METHODS
We performed a retrospective pilot cohort study including 14 patients undergoing same day HRM prior to BAS and 20 patients undergoing BAS alone over an 8-month interval during the COVID-19 pandemic. Three abdominal imaging subspecialty-trained radiologists blindly reviewed the images and graded adequacy of esophageal coating on a 4-point scale with a score of 1 representing inadequate coating and 4 representing optimal coating.
RESULTS
For the cohort studied thus far, the mean grade of the HRM and BAS group was 3.17 with a standard deviation of 0.66. The mean grade of the BAS alone group was 3.13 with a standard deviation of 0.79. There was no statistical difference in the adequacy of esophageal coating between the two groups (p-value 0.97).
CONCLUSION
Same day HRM prior to BAS has no detrimental effect on barium mucosal coating compared to BAS alone. Though created to limit patient exposures during the COVID pandemic, same day BAS and HRM may prevent delays in care and improve convenience towards improved patient-centered care beyond the pandemic.
Topics: Barium; COVID-19; Humans; Manometry; Pandemics; Pilot Projects; Retrospective Studies; SARS-CoV-2
PubMed: 34687322
DOI: 10.1007/s00261-021-03322-2 -
The Turkish Journal of Gastroenterology... Dec 2017Ambulatory esophageal pH monitoring is an essential method in patients exhibiting signs of non-erosive reflux disease (NERD) to make an objective diagnosis.... (Review)
Review
Indications of 24-h esophageal pH monitoring, capsule pH monitoring, combined pH monitoring with multichannel impedance, esophageal manometry, radiology and scintigraphy in gastroesophageal reflux disease?
Ambulatory esophageal pH monitoring is an essential method in patients exhibiting signs of non-erosive reflux disease (NERD) to make an objective diagnosis. Intra-esophageal pH monitoring is important in patients who are non-responsive to medications and in those with extraesophageal symptoms, particularly in NERD, before surgical interventions. With the help of the wireless capsule pH monitoring, measurements can be made under more physiological conditions as well as longer recordings can be performed because the investigation can be better tolerated by patients. Ambulatory esophageal pH monitoring can be detected within normal limits in 17%-31.4% of the patients with endoscopic esophagitis; therefore, normal pH monitoring cannot exclude the diagnosis of gastroesophageal reflux disease (GERD). Multi-channel intraluminal impedance pH (MII-pH) technology have been developed and currently the most sensitive tool to evaluate patients with both typical and atypical reflux symptoms. The sensitivity of a pH catheter test is 58% for the detection of acid reflux compared with MII-pH monitoring; further, its sensitivity is 28% for the detection of weak acid reflux compared with MII-pH monitoring. By adding impedance to pH catheter in patients with reflux symptoms, particularly in those receiving PPIs, it has been demonstrated that higher rates of diagnoses and symptom analyses can be obtained than those using only pH catheter. Esophageal manometry is used in the evaluation of patients with functional dysphagia and unexplained noncardiac chest pain and prior to antireflux surgery. The use of esophageal manometry is suitable for the detection of esophageal motor patterns and extreme motor abnormalities (e.g., achalasia and extreme hypomotility). Esophageal manometry and ambulatory pH monitoring are often used in assessments prior to laparoscopic antireflux surgery and in patients with reflux symptoms refractory to medical treatment. Although the esophageal motility is predominantly normal in patients with non-acid reflux, ineffective esophageal motility is often monitored in patients with acid reflux. In the literature, there are contradictory and an insufficient number of studies regarding radiological methods for the diagnosis of GERD. There are inconsistent values for sensitivity and specificity among the barium studies. There are inadequate studies in the literature involving scintigraphic examinations in the diagnosis of GERD, and a majority of existing studies have been conducted in the pediatric group. The results of a few studies do not provide sufficient contribution toward the implementation in clinical practice.
Topics: Adult; Child; Electric Impedance; Esophageal pH Monitoring; Esophagus; Female; Gastroesophageal Reflux; Humans; Male; Manometry; Middle Aged; Predictive Value of Tests; Radiography; Radionuclide Imaging; Reproducibility of Results; Sensitivity and Specificity
PubMed: 29199161
DOI: 10.5152/tjg.2017.06 -
Dysphagia Dec 2022There has been a recent shift towards proactive dysphagia intervention in motor neurone disease (MND) to maintain physiological reserve. Pharyngeal high-resolution... (Review)
Review
There has been a recent shift towards proactive dysphagia intervention in motor neurone disease (MND) to maintain physiological reserve. Pharyngeal high-resolution manometry (PHRM) can quantify swallowing pathophysiology to inform and evaluate proactive dysphagia intervention. This study aims to explore the current use of PHRM as a dysphagia evaluation in adults with MND. A scoping review based on the Joanna Briggs Framework was completed. Four electronic databases (PubMed, EMBASE, CINAHL and Web of Science core) were searched (inception to March 2021) by two independent researchers. Data were analysed according to (i) PHRM protocol and analysis methods and the feasibility of same, (ii) swallow biomechanics data and (iii) dysphagia intervention effects as measured by PHRM. Six studies with 78 people with MND (PwMND) were included. There was considerable variation in PHRM protocol and analysis methods. Five studies reported a 100% completion rate and three studies reported no adverse events. Swallow biomechanics data were reported across all studies. The effects of sensory stimulation, increased bolus consistency, effortful swallow and cricopharyngeal myotomy were evaluated using PHRM with 20 PwMND across four studies with varying effects. Literature on the use of PHRM in PwMND is limited. Variability in PHRM methods restricts comparison of metrics. PHRM appears to be a feasible tool for PwMND. PHRM can provide novel swallow physiology data in PwMND and quantify discrete effects of compensatory and surgical dysphagia interventions not detectable by videofluoroscopy or FEES. Further research on the effects of proactive dysphagia intervention as measured by PHRM is required.
Topics: Adult; Humans; Deglutition Disorders; Deglutition; Manometry; Pharynx; Motor Neuron Disease
PubMed: 35235032
DOI: 10.1007/s00455-022-10418-4 -
Gastroenterology Dec 2022The utility of high-resolution anorectal manometry (HR-ARM) for diagnosing defecatory disorders (DDs) is unclear because healthy people may have features of dyssynergia....
BACKGROUND & AIMS
The utility of high-resolution anorectal manometry (HR-ARM) for diagnosing defecatory disorders (DDs) is unclear because healthy people may have features of dyssynergia. We aimed to identify objective diagnostic criteria for DD and to ascertain the utility of HR-ARM for diagnosing DD.
METHODS
Constipated patients were assessed with HR-ARM and rectal balloon expulsion time (BET), and a subset underwent defecography. Normal values were established by assessing 184 sex-matched healthy individuals. Logistic regression models evaluated the association of abnormal HR-ARM findings with prolonged BET and reduced rectal evacuation (determined by defecography).
RESULTS
A total of 474 constipated individuals (420 women) underwent HR-ARM and BET, and 158 underwent defecography. BET was prolonged, suggesting a DD, for 152 patients (32%). Rectal evacuation was lower for patients with prolonged vs normal BET. A lower rectoanal gradient during evacuation, reduced anal squeeze increment, and reduced rectal sensation were independently associated with abnormal BETs; the rectoanal gradient was 36% sensitive and 85% specific for prolonged BET. A lower rectoanal gradient and prolonged BET were independently associated with reduced evacuation. Among constipated patients, the probability of reduced rectal evacuation was 14% when the gradient and BET were both normal, 45% when either was abnormal, and 75% when both variables were abnormal.
CONCLUSIONS
HR-ARM, BET, and defecography findings were concordant for constipated patients, and reduced rectoanal gradient was the best HR-ARM predictor of prolonged BET or reduced rectal evacuation. Prolonged BET, reduced gradient, and reduced evacuation each independently supported a diagnosis of DD in constipated patients. We propose the terms probable DD for patients with an isolated abnormal gradient or BET and definite DD for patients with abnormal results from both tests.
Topics: Humans; Female; Defecography; Constipation; Health Status; Logistic Models; Manometry
PubMed: 35995074
DOI: 10.1053/j.gastro.2022.08.034