Arquivos Brasileiros de Cardiologia 2023Sudden cardiac death (SCD) resulting from ventricular arrhythmia is the main complication of hypertrophic cardiomyopathy (HCM). Microvolt T-wave alternans (MTWA) is...
BACKGROUND
Sudden cardiac death (SCD) resulting from ventricular arrhythmia is the main complication of hypertrophic cardiomyopathy (HCM). Microvolt T-wave alternans (MTWA) is associated with the occurrence of ventricular arrhythmias in several heart diseases, but its role in HCM remains uncertain.
OBJECTIVE
To evaluate the association of MTWA with the occurrence of SCD or potentially fatal ventricular arrhythmias in HCM patients in a long-term follow-up.
METHODS
Patients diagnosed with HCM and NYHA functional class I-II were consecutively selected. At the beginning of the follow-up, the participants performed the MTWA evaluation using the modified moving average during the stress test. The results were classified as altered or normal. The composite endpoint of SCD, ventricular fibrillation, sustained ventricular tachycardia (SVT) or appropriate implantable cardiac defibrillation (ICD) therapy was assessed. The level of significance was set at 5%.
RESULTS
A total of 132 patients (mean age of 39.5 ± 12.6 years) were recruited and followed for a mean of 9.5 years. The MTWA test was altered in 74 (56%) participants and normal in 58 (44%). Nine events (6.8%) occurred during the follow-up, with a prevalence of 1.0%/year - six SCDs, two appropriate ICD shocks and one episode of (SVT). Altered MTWA was associated with non-sustained ventricular tachycardia on Holter (p = 0.016), septal thickness ≥30 mm (p < 0.001) and inadequate blood pressure response to effort (p = 0.046). Five patients with altered MTWA (7%) and four patients with normal MTWA (7%) had the primary outcome [OR = 0.85 (95% CI: 0.21 - 3.35, p=0.83)]. Kaplan-Meir event curves showed no differences between normal and altered MTWA.
CONCLUSION
Altered MTWA was not associated with the occurrence of SCD or potentially fatal ventricular arrhythmias in HCM patients, and the low rate of these events during long-term follow-up suggests the good prognosis of this heart disease.
Topics: Humans; Adult; Middle Aged; Prognosis; Follow-Up Studies; Arrhythmias, Cardiac; Cardiomyopathy, Hypertrophic; Death, Sudden, Cardiac; Tachycardia, Ventricular; Ventricular Fibrillation; Anti-Arrhythmia Agents; Cardiotonic Agents; Diuretics
PubMed: 37672406
DOI: 10.36660/abc.20220833 -
Sovremennye Tekhnologii V Meditsine 2021was to develop an ECG hardware and software system for monitoring electrical instability of the myocardium and to assess the diagnostic and prognostic capabilities of...
UNLABELLED
was to develop an ECG hardware and software system for monitoring electrical instability of the myocardium and to assess the diagnostic and prognostic capabilities of this setup in a cardiology clinic.
MATERIALS AND METHODS
The Intecard 7.3 software and hardware system developed in this study makes it possible to measure fluctuations of the ECG amplitude-time parameters using the beat-to-beat mode. Intecard 7.3 evaluates a number of ECG markers that reflect electrical instability of the myocardium. Among them are the fragmented QRS complex, the spatial QRS-T angle, the T-wave alternans, the duration, and dispersion of the QT interval, the turbulence and acceleration/deceleration of the heart rhythm.Clinical trials of Intecard 7.3 were carried out with 734 patients with ischemic heart disease or cardiomyopathy and 112 healthy individuals.
RESULTS
Intecard 7.3 reliably identifies fragmented QRS complexes by detecting short spikes of <25 ms in the ascending parts of the Q, R, and S waves. The QRS-T angle is determined from the reference amplitudes of the R and T waves in leads avF, V, V, and V. Digital precision processing of the ECG signal improves its accuracy to microvolts and microseconds.The software was designed to measure the T-wave amplitude in each of 300-500 cardiobeats; T-wave alternans was estimated by the moving average method. In a typical cardiobeat, the QT dispersion was calculated based on 12 ECG leads. From the sequence of RR intervals, turbulence, and deceleration of the heart rhythm were determined.During the observation period of 5.0 [2.1; 5.9] years, 90 out of 734 patients (12.3%) experienced adverse cardiovascular events (ACVE). In this period, the myocardial electrical instability was recorded in patients with ACVE more frequently than in those without ACVE. Thus, the frequency of fragmented QRS was 72.2±4.7 vs 16.8±1.5% (p<0.01), the values of the QRS-T angle were 128 [55; 101] vs 80 [53; 121]° (p<0.001), the T-wave alternans - 36.9 [15.5; 62.1] vs 21.9 [10.2; 30.7] μV (p<0.005), the QT interval - 408 [383; 438] vs 376 [351; 400] ms (p<0.001), the QT dispersion - 76 [57; 96] vs 64 [50; 92] ms (p<0.005), respectively. In patients with ACVE, the threshold that triggers pathological rhythm turbulence was higher (>0%) than that in healthy controls (p<0.001); the deceleration of the heart rhythm was reduced from 19.2 [2.2; 38.0] to 8.8 [4.0; 16.8] ms (p<0.05).A personalized model for ACVE risk stratification has been developed. In this model, the area under the ROC curve was 0.856; sensitivity - 75%; specificity - 78%; predictive accuracy - 77%.
CONCLUSION
Using the ECG markers of myocardial electrical instability, the Intecard 7.3 system allows one to predict life-threatening ventricular tachyarrhythmias and sudden cardiac death with an accuracy of 77%. The non-invasiveness, high productivity, and reasonable cost ensure the availability of this predictive technology in all levels of healthcare.
Topics: Arrhythmias, Cardiac; Death, Sudden, Cardiac; Electrocardiography; Humans; Myocardium; Tachycardia, Ventricular
PubMed: 34796014
DOI: 10.17691/stm2020.12.6.02 -
Cardiology Journal 2022Major adverse cardiovascular events (MACE) constitutes the main cause of morbidity and mortality in ischemic heart failure (HF) patients. The prognostic value of the...
BACKGROUND
Major adverse cardiovascular events (MACE) constitutes the main cause of morbidity and mortality in ischemic heart failure (HF) patients. The prognostic value of the autonomic nervous system parameters and microvolt T-wave alternans (MTWA) in this issue has not been identified to date. The aim herein, was to assess the usefulness of the abovementioned parameters in the prediction of MACE in HF patients with left ventricular systolic dysfunction of ischemic origin.
METHODS
Baroreflex sensitivity (BRS), heart rate variability (HRV), MTWA and other well-known clinical parameters were analyzed in 188 ischemic HF outpatients with left ventricular ejection fraction (LVEF) ≤ 50%. During 34 (14-71) months of follow-up, 56 (30%) endpoints were noted.
RESULTS
Univariate Cox analyses revealed BRS (but not HRV), MTWA, age, New York Heart Association functional class III, LVEF, implantable cardioverter-defibrillator presence, use of diuretics and antiarrhythmic drugs, diabetes, and kidney insufficiency were defined as significant predictors of MACE. Pre-specified cut-off values for MACE occurrence for the aforementioned continuous parameters (age, LVEF, and BRS) were: ≥ 72 years, ≤ 33%, and ≤ 3 ms/mmHg, respectively. In a multivariate Cox analysis only BRS (HR 2.97, 95% CI 1.35-6.36, p < 0.006), and LVEF (HR 1.98, 95% CI 0.61-4.52, p < 0.038) maintained statistical significance in the prediction of MACE.
CONCLUSIONS
Baroreflex sensitivity and LVEF are independent of other well-known clinical parameters in the prediction of MACE in patients with HF of ischemic origin and LVEF up to 50%. BRS ≤ 3 ms/mmHg and LVEF ≤ 33% identified individuals with the highest probability of MACE during the follow-up period.
Topics: Humans; Aged; Baroreflex; Stroke Volume; Death, Sudden, Cardiac; Ventricular Function, Left; Arrhythmias, Cardiac; Heart Failure; Prognosis; Defibrillators, Implantable
PubMed: 33001423
DOI: 10.5603/CJ.a2020.0129 -
Science Translational Medicine Sep 2022Chronic nausea and vomiting syndromes (NVSs) are prevalent and debilitating disorders. Putative mechanisms include gastric neuromuscular disease and dysregulation of...
Chronic nausea and vomiting syndromes (NVSs) are prevalent and debilitating disorders. Putative mechanisms include gastric neuromuscular disease and dysregulation of brain-gut interaction, but clinical tests for objectively defining gastric motor function are lacking. A medical device enabling noninvasive body surface gastric mapping (BSGM) was developed and applied to evaluate NVS pathophysiology. BSGM was performed in 43 patients with NVS and 43 matched controls using Gastric Alimetry (Alimetry), a conformable high-resolution array (8 × 8 electrodes; 20-mm interelectrode spacing), wearable reader, and validated symptom-logging app. Continuous measurement encompassed a fasting baseline (30 minutes), 482-kilocalorie meal, and 4-hour postprandial recording, followed by spectral and spatial biomarker analyses. Meal responses were impaired in NVS, with reduced amplitudes compared to controls (median, 23.3 microvolts versus 38.0 microvolts, < 0.001), impaired fed-fasting power ratios (1.1 versus 1.6, = 0.02), and disorganized slow waves (spatial frequency stability, 13.6 versus 49.5; < 0.001). Two distinct NVS subgroups were evident with indistinguishable symptoms (all > 0.05). Most patients (62%) had normal BSGM studies with increased psychological comorbidities (43.5% versus 7.7%; = 0.03) and anxiety scores (median, 16.5 versus 13.0; = 0.035). A smaller subgroup (31%) had markedly abnormal BSGM, with biomarkers correlating with symptoms (nausea, pain, excessive fullness, early satiety, and bloating; all > 0.35, < 0.05). Patients with NVS share overlapping symptoms but comprise distinct underlying phenotypes as revealed by a BSGM device. These phenotypes correlate with symptoms, which should inform clinical management and therapeutic trial design.
Topics: Gastric Emptying; Humans; Nausea; Stomach; Syndrome; Vomiting
PubMed: 36130019
DOI: 10.1126/scitranslmed.abq3544 -
Journal of Electrical Bioimpedance Jan 2023Biomedical engineering stands at the forefront of medical innovation, with electroencephalography (EEG) signal analysis providing critical insights into neural...
Biomedical engineering stands at the forefront of medical innovation, with electroencephalography (EEG) signal analysis providing critical insights into neural functions. This paper delves into the utilization of EEG signals within the MILimbEEG dataset to explore their potential for machine learning-based task recognition and diagnosis. Capturing the brain's electrical activity through electrodes 1 to 16, the signals are recorded in the time-domain in microvolts. An advanced feature extraction methodology harnessing Hjorth Parameters-namely Activity, Mobility, and Complexity-is employed to analyze the acquired signals. Through correlation analysis and examination of clustering behaviors, the study presents a comprehensive discussion on the emergent patterns within the data. The findings underscore the potential of integrating these features into machine learning algorithms for enhanced diagnostic precision and task recognition in biomedical applications. This exploration paves the way for future research where such signal processing techniques could revolutionize the efficiency and accuracy of biomedical engineering diagnostics.
PubMed: 38162817
DOI: 10.2478/joeb-2023-0009 -
The American Journal of Forensic... Jun 2015Electromuscular incapacitating devices (EMDs) are high-voltage, low-current stimulators causing involuntary muscle contractions and sensory response. Existing evidence...
Electromuscular incapacitating devices (EMDs) are high-voltage, low-current stimulators causing involuntary muscle contractions and sensory response. Existing evidence about cardiac effects of EMD remains inconclusive. The aim of our study was to analyze electrocardiographic, echocardiographic, and microvolt T-wave alternans (MTWA) changes induced by EMD discharge.We examined 26 volunteers (22 men; median age 30 years) who underwent single standard 5-second duration exposure to TASER X26 under continuous echocardiographic and electrocardiographic monitoring. Microvolt T-wave alternans testing was performed at baseline (MTWA-1), as well as immediately and 60 minutes after EMD exposure (MTWA-2 and MTWA-3, respectively).Mean heart rate (HR) increased significantly from 88 ± 17 beats per minute before to 129 ± 17 beats per minute after exposure (P < 0.001). However, in 2 individuals, an abrupt decrease in HR was observed. In one of them, interval between two consecutive beats increased up to 1.7 seconds during the discharge. New onset of supraventricular premature beats was observed after discharge in 1 patient. Results of MTWA-1, MTWA-2, and MTWA-3 tests were positive in one of the subjects, each time in a different case.Standard EMD exposure can be associated with a nonuniform reaction of HR and followed by heart rhythm disturbances. New MTWA positivity can reflect either the effect of EMD exposure or a potential false positivity of MTWA assessments.
Topics: Adult; Bradycardia; Conducted Energy Weapon Injuries; Echocardiography, Doppler; Electrocardiography; Female; Healthy Volunteers; Humans; Male; Middle Aged; Severity of Illness Index; Young Adult
PubMed: 25710795
DOI: 10.1097/PAF.0000000000000143 -
American Journal of Physiology. Heart... May 2016One of the main constraints associated with recording sympathetic nerve activity (SNA) in both humans and experimental animals is that microvolt values reflect... (Comparative Study)
Comparative Study
One of the main constraints associated with recording sympathetic nerve activity (SNA) in both humans and experimental animals is that microvolt values reflect characteristics of the recording conditions and limit comparisons between different experimental groups. The nasopharyngeal response has been validated for normalizing renal SNA (RSNA) in conscious rabbits, and in humans muscle SNA is normalized to the maximum burst in the resting period. We compared these two methods of normalization to determine whether either could detect elevated RSNA in hypertensive rabbits compared with normotensive controls. We also tested whether either method eliminated differences based only on different recording conditions by separating RSNA of control (sham) rabbits into two groups with low or high microvolts. Hypertension was induced by 5 wk of renal clipping (2K1C), 3 wk of high-fat diet (HFD), or 3 mo infusion of a low dose of angiotensin (ANG II). Normalization to the nasopharyngeal response revealed RSNA that was 88, 51, and 34% greater in 2K1C, HFD, and ANG II rabbits, respectively, than shams (P < 0.05), but normalization to the maximum burst showed no differences. The RSNA baroreflex followed a similar pattern whether RSNA was expressed in microvolts or normalized. Both methods abolished the difference between low and high microvolt RSNA. These results suggest that maximum burst amplitude is a useful technique for minimizing differences between recording conditions but is unable to detect real differences between groups. We conclude that the nasopharyngeal reflex is the superior method for normalizing sympathetic recordings in conscious rabbits.
Topics: Action Potentials; Angiotensin II; Animals; Arterial Pressure; Baroreflex; Blood Pressure Determination; Calibration; Consciousness; Constriction; Diet, High-Fat; Disease Models, Animal; Electrodiagnosis; Heart Rate; Hypertension; Kidney; Male; Models, Animal; Muscle, Skeletal; Nasopharynx; Rabbits; Renal Artery; Reproducibility of Results; Signal Processing, Computer-Assisted; Sympathetic Nervous System; Telemetry; Time Factors
PubMed: 26921439
DOI: 10.1152/ajpheart.00866.2015 -
Arquivos Brasileiros de Cardiologia May 2018Sudden cardiac death is the most frequent death mechanism in Chagas disease, responsible for 55% to 65% of the deaths of patients with chronic Chagas cardiomyopathy... (Observational Study)
Observational Study
BACKGROUND
Sudden cardiac death is the most frequent death mechanism in Chagas disease, responsible for 55% to 65% of the deaths of patients with chronic Chagas cardiomyopathy (CCC). The most often involved electrophysiological mechanisms are ventricular tachycardia and ventricular fibrillation. The implantable cardioverter defibrillator (ICD) has a beneficial role in preventing sudden death due to malignant ventricular arrhythmias, and, thus the correct identification of patients at risk is required. The association of microvolt T-wave alternans (MTWA) with the appearance of ventricular arrhythmias has been assessed in different heart diseases. The role of MTWA is mostly unknown in patients with CCC.
OBJECTIVES
To evaluate the association between MTWA and the occurrence of malignant ventricular arrhythmias in patients with CCC.
METHOD
This is a case-control study including patients with CCC and ICD, with history of malignant ventricular arrhythmias (case group), and patients with CCC and no history of those arrhythmias (control group). The MTWA test results were classified as negative and non-negative (positive and indeterminate). The significance level adopted was a = 0.05.
RESULTS
We recruited 96 patients, 45 cases (46.8%) and 51 controls (53.1%). The MTWA test was non-negative in 36/45 cases (80%) and 15/51 controls (29.4%) [OR = 9.60 (95%CI: 3.41 - 27.93)]. After adjustment for known confounding factors in a logistic regression model, the non-negative result continued to be associated with malignant ventricular arrhythmias [OR = 5.17 (95%CI: 1.05 - 25.51)].
CONCLUSION
Patients with CCC and history of malignant ventricular arrhythmias more often have a non-negative MTWA test as compared to patients with no history of arrhythmia.
Topics: Arrhythmias, Cardiac; Case-Control Studies; Chagas Disease; Death, Sudden, Cardiac; Defibrillators, Implantable; Electrocardiography; Female; Humans; Male; Middle Aged; Risk Factors; Survival Analysis; Tachycardia, Ventricular
PubMed: 29641645
DOI: 10.5935/abc.20180056 -
Journal of the American Heart... Dec 2021Background Unlike T-wave alternans (TWA), the relation between QRS alternans (QRSA) and ventricular arrhythmia (VA) risk has not been evaluated in hypertrophic...
Background Unlike T-wave alternans (TWA), the relation between QRS alternans (QRSA) and ventricular arrhythmia (VA) risk has not been evaluated in hypertrophic cardiomyopathy (HCM). We assessed microvolt QRSA/TWA in relation to HCM risk factors and late VA outcomes in HCM. Methods and Results Prospectively enrolled patients with HCM (n=130) with prophylactic implantable cardioverter-defibrillators underwent digital 12-lead ECG recordings during ventricular pacing (100-120 beats/min). QRSA/TWA was quantified using the spectral method. Patients were categorized as QRSA+ and/or TWA+ if sustained alternans was present in ≥2 precordial leads. The VA end point was appropriate implantable cardioverter-defibrillator therapy over 5 years of follow-up. QRSA+ and TWA+ occurred together in 28% of patients and alone in 7% and 7% of patients, respectively. QRSA magnitude increased with pacing rate (1.9±0.6 versus 6.2±2.0 µV; =0.006). Left ventricular thickness was greater in QRSA+ than in QRSA- patients (22±7 versus 20±6 mm; =0.035). Over 5 years follow-up, 17% of patients had VA. The annual VA rate was greater in QRSA+ versus QRSA- patients (5.8% versus 2.0%; =0.006), with the QRSA+/TWA- subgroup having the greatest rate (13.3% versus 2.6%; <0.001). In those with <2 risk factors, QRSA- patients had a low annual VA rate compared QRSA+ patients (0.58% versus 7.1%; =0.001). Separate Cox models revealed QRSA+ (hazard ratio [HR], 2.9 [95% CI, 1.2-7.0]; =0.019) and QRSA+/TWA- (HR, 7.9 [95% CI, 2.9-21.7]; <0.001) as the most significant VA predictors. TWA and HCM risk factors did not predict VA. Conclusions In HCM, microvolt QRSA is a novel, rate-dependent phenomenon that can exist without TWA and is associated with greater left ventricular thickness. QRSA increases VA risk 3-fold in all patients, whereas the absence of QRSA confers low VA risk in patients with <2 risk factors. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02560844.
Topics: Arrhythmias, Cardiac; Cardiomyopathy, Hypertrophic; Humans; Risk Factors
PubMed: 34854315
DOI: 10.1161/JAHA.121.022036 -
Cardiology Research Feb 2023Cardiac arrhythmias are significantly associated with poor outcomes in coronavirus disease 2019 (COVID-19) patients. Microvolt T-wave alternans (TWA) can be...
BACKGROUND
Cardiac arrhythmias are significantly associated with poor outcomes in coronavirus disease 2019 (COVID-19) patients. Microvolt T-wave alternans (TWA) can be automatically quantified and has been recognized as a representation of repolarization heterogeneity and linked to arrhythmogenesis in various cardiovascular diseases. This study aimed to explore the correlation between microvolt TWA and COVID-19 pathology.
METHODS
Patients suspected of COVID-19 in Mohammad Hoesin General Hospital were consecutively evaluated using Alivecor Kardiamobile 6L™ portable electrocardiogram (ECG) device. Severe COVID-19 patients or those who are unable to cooperate in active ECG self-recording were excluded from the study. TWA was detected and its amplitude was quantified using the novel enhanced adaptive match filter (EAMF) method.
RESULTS
A total of 175 patients, 114 COVID-19 patients (polymerase chain reaction (PCR)-positive group), and 61 non-COVID-19 patients (PCR-negative group) were enrolled in the study. PCR-positive group was subdivided according to the severity of COVID-19 pathology into mild and moderate severity subgroups. Baseline TWA levels were similar between both groups during admission (42.47 ± 26.52 µV vs. 44.72 ± 38.21 µV), but higher TWA levels were observed during discharge in the PCR-positive compared to the PCR-negative group (53.45 ± 34.42 µV vs. 25.15 ± 17.64 µV, P = 0.03). The correlation between PCR-positive result in COVID-19 and TWA value was significant, after adjustment of other confounding variables (R = 0.081, P = 0.030). There was no significant difference in TWA levels between mild and moderate severity subgroups in patients with COVID-19, both during admission (44.29 ± 27.14 µV vs. 36.75 ± 24.46 µV, P = 0.34) and discharge (49.47 ± 33.62 µV vs. 61.09 ± 35.99 µV, P = 0.33).
CONCLUSIONS
Higher TWA values can be observed on follow-up ECG obtained during discharge in the PCR-positive COVID-19 patients.
PubMed: 36896221
DOI: 10.14740/cr1458