-
Experimental Physiology Apr 2021What is the central question of this study? What are the mechanisms by which equine sweat glands transport sodium, potassium and water into sweat? What is the main...
NEW FINDINGS
What is the central question of this study? What are the mechanisms by which equine sweat glands transport sodium, potassium and water into sweat? What is the main finding and its importance? The flux of sodium into sweat does not have an active transport component, the flux of potassium into sweat is partially dependent on an active transport mechanism, and there is no evidence for paracellular transport.
ABSTRACT
In two series of experiments, this study used radioactive sodium (Na ) and potassium (K ) to trace the net flux, and calculate the unidirectional fluxes, of these ions from extracellular fluid into sweat of horses during exercise and recovery. The effect of an oral electrolyte supplement (PNW) on the sweating responses and ion fluxes was also examined. Compared to 8 litres of water (controls), provision of 8 litres of PNW resulted in significantly increased sweating duration (P < 0.001). Two hours before exercise, Tc-labelled diethylene-triamine-pentaacetate (DTPA) was administered i.v. to determine if there was paracellular flux of this molecule in sweat glands during the period of sweating. One hour before beginning moderate-intensity exercise, horses were nasogastrically administered either Na (1-3 litres) or K (8 litres) with water (control) or an electrolyte supplement. Both radiotracers appeared in sweat within 10 min of exercise onset, and the sweat specific activity of both ions increased during exercise (P < 0.001), approaching plasma specific activities. There was no appearance of Tc-DTPA in sweat. The activities of Na and K, together with the concentrations Na , K and Cl , argued against significant paracellular flux of these ions into the lumen of sweat glands. The flux analysis for Na indicated a small intracellular pool within sweat gland cells, and no evidence for an active transport component. The flux analysis for K indicated a relatively large intracellular equilibration pool within sweat gland cells, with evidence for an active transport component. The results are discussed with respect to the current understanding of sweat gland epithelial cell ion transport mechanisms at both the basal and the apical membranes. It appears likely that the majority of ions appearing in sweat pass through sweat gland epithelial cells by transcellular mechanisms that include ion transporting pathways as well as apical vesicular exocytosis.
Topics: Animals; Chlorides; Horses; Physical Conditioning, Animal; Potassium; Sodium; Sweat; Sweating; Water
PubMed: 33550621
DOI: 10.1113/EP089232 -
Microbiology Spectrum Feb 2023The microorganisms inhabiting human skin must overcome numerous challenges that typically impede microbial growth, including low pH, osmotic pressure, and low nutrient...
The microorganisms inhabiting human skin must overcome numerous challenges that typically impede microbial growth, including low pH, osmotic pressure, and low nutrient availability. Yet the skin microbiota thrive on the skin and have adapted to these stressful conditions. The limited nutrients available for microbial use in this unique niche include those from host-derived sweat, sebum, and corneocytes. Here, we have developed physiologically relevant, synthetic skin-like growth media composed of compounds present in sweat and sebum. We find that skin-associated bacterial species exhibit unique growth profiles at different concentrations of artificial sweat and sebum. Most strains evaluated demonstrate a preference for high sweat concentrations, while the sebum preference is highly variable, suggesting that the capacity for sebum utilization may be a driver of the skin microbial community structure. In particular, the prominent skin commensal Staphylococcus epidermidis exhibits the strongest preference for sweat while growing equally well across sebum concentrations. Conversely, the growth of Corynebacterium kefirresidentii, another dominant skin microbiome member, is dependent on increasing concentrations of both sweat and sebum but only when sebum is available, suggesting a lipid requirement of this species. Furthermore, we observe that strains with similar growth profiles in the artificial media cluster by phylum, suggesting that phylogeny is a key factor in sweat and sebum use. Importantly, these findings provide an experimental rationale for why different skin microenvironments harbor distinct microbiome communities. In all, our study further emphasizes the importance of studying microorganisms in an ecologically relevant context, which is critical for our understanding of their physiology, ecology, and function on the skin. The human skin microbiome is adapted to survive and thrive in the harsh environment of the skin, which is low in nutrient availability. To study skin microorganisms in a system that mimics the natural skin environment, we developed and tested a physiologically relevant, synthetic skin-like growth medium that is composed of compounds found in the human skin secretions sweat and sebum. We find that most skin-associated bacterial species tested prefer high concentrations of artificial sweat but that artificial sebum concentration preference varies from species to species, suggesting that sebum utilization may be an important contributor to skin microbiome composition. This study demonstrates the utility of a skin-like growth medium, which can be applied to diverse microbiological systems, and underscores the importance of studying microorganisms in an ecologically relevant context.
Topics: Humans; Sweat; Sebum; Skin; Microbiota; Bacteria
PubMed: 36602383
DOI: 10.1128/spectrum.04180-22 -
The Indian Journal of Medical Research Nov 2020
Topics: Humans; Hypohidrosis; Sweating
PubMed: 35345113
DOI: 10.4103/ijmr.IJMR_1768_19 -
Advanced Science (Weinheim,... Jan 2022Wearable sweat sensors have received significant research interest and have become popular as sweat contains considerable health information about physiological and... (Review)
Review
Wearable sweat sensors have received significant research interest and have become popular as sweat contains considerable health information about physiological and psychological states. However, measured biomarker concentrations vary with sweat rates, which has a significant effect on the accuracy and reliability of sweat biosensors. Wearable sweat loss measuring devices (SLMDs) have recently been proposed to overcome the limitations of biomarker tracking and reduce inter- and intraindividual variability. In addition, they offer substantial potential for monitoring human body homeostasis, because sweat loss plays an indispensable role in thermoregulation and skin hydration. Previous studies have not carried out a comprehensive and systematic review of the principles, importance, and development of wearable SLMDs. This paper reviews wearable SLMDs with a new health perspective from the role of sweat loss to advanced mechanisms and designs. Two types of sweat and their measurement significance for practical applications are highlighted. Then, a comprehensive review of advances in different wearable SLMDs based on hygrometers, absorbent materials, and microfluidics is presented by describing their respective device architectures, present situations, and future directions. Finally, concluding remarks on opportunities for future application fields and challenges for future sweat sensing are presented.
Topics: Biosensing Techniques; Equipment Design; Humans; Monitoring, Physiologic; Sweat; Wearable Electronic Devices
PubMed: 34713981
DOI: 10.1002/advs.202103257 -
Sensors (Basel, Switzerland) Nov 2020Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers... (Review)
Review
Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers and providers. This work overviews the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz. tears, sweat, saliva, and urine. Described electrochemical devices are based on different electrochemical techniques, viz. amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy. Challenges that confront researchers in this exciting area and key requirements for biodevices are discussed. It is concluded that the field of non-invasive sensing of biomarkers in bodily fluid is highly convoluted. Nonetheless, if the drawbacks are appropriately addressed, and the pitfalls are adroitly circumvented, the approach will most certainly disrupt current clinical and self-monitoring practices.
Topics: Biosensing Techniques; Body Fluids; Electrochemical Techniques; Humans; Saliva; Sweat; Tears; Urine
PubMed: 33171750
DOI: 10.3390/s20216352 -
Advanced Science (Weinheim,... Mar 2022Human health and performance monitoring (HHPM) is imperative to provide information necessary for protecting, sustaining, evaluating, and improving personnel in various... (Review)
Review
Human health and performance monitoring (HHPM) is imperative to provide information necessary for protecting, sustaining, evaluating, and improving personnel in various occupational sectors, such as industry, academy, sports, recreation, and military. While various commercially wearable sensors are on the market with their capability of "quantitative assessments" on human health, physical, and psychological states, their sensing is mostly based on physical traits, and thus lacks precision in HHPM. Minimally or noninvasive biomarkers detectable from the human body, such as body fluid (e.g., sweat, tear, urine, and interstitial fluid), exhaled breath, and skin surface, can provide abundant additional information to the HHPM. Detecting these biomarkers with novel or existing sensor technologies is emerging as critical human monitoring research. This review provides a broad perspective on the state of the art biosensor technologies for HHPM, including the list of biomarkers and their physiochemical/physical characteristics, fundamental sensing principles, and high-performance sensing transducers. Further, this paper expands to the additional scope on the key technical challenges in applying the current HHPM system to the real field.
Topics: Biomarkers; Biosensing Techniques; Humans; Monitoring, Physiologic; Sweat; Wearable Electronic Devices
PubMed: 35023321
DOI: 10.1002/advs.202104426 -
Talanta Mar 2021Rapid, periodic monitoring and detection of ethanol (EtOH) after consumption via a non-invasive measurement has been an area of increased research in recent years....
Rapid, periodic monitoring and detection of ethanol (EtOH) after consumption via a non-invasive measurement has been an area of increased research in recent years. Current point-of-care or on-site detection strategies rely on single use sensors which are inadequate for monitoring during a longer period. A low cost, portable and novel approach is developed here for real-time monitoring over several days utilising electrochemical techniques. The sensor shows oxidation of the ethanol in phosphate buffer and artificial sweat using the amperometric response from the application of +0.9 V to the polyaniline modified screen printed electrode using 1 mM EtOH as the averaged amount of EtOH eliminated in sweat after the consumption of one alcoholic beverage. Our enzyme based electrochemical sensor exhibits a qualitative assessment of the presence of EtOH in small volumes (≤40 μL) of 0.1 M sodium bicarbonate and subsequently artificial sweat, with 50 measurements taken daily over 11 days. While quantitative information is not obtained, the sensor system exhibits excellent stability after 3 months' dried storage in this complex biological matrix in an oxygen free cabinet. This addresses one of the key challenges for enzyme based electrochemical sensors, namely, the ability for real-time monitoring in complex biological matrices. The qualitative response illustrates the potential for this sensor to be exploited by non-experts which suggests the promise for their wider application in next-generation wearable electronics necessary for alcohol monitoring.
Topics: Biosensing Techniques; Electrochemical Techniques; Electrodes; Ethanol; Sweat
PubMed: 33379040
DOI: 10.1016/j.talanta.2020.121815 -
Forensic Science International Dec 2016Passive exposure to cannabis smoke may induce effects on behavior and psychomotor skills, and have legal consequences, including the risk of being falsely considered as... (Review)
Review
Passive exposure to cannabis smoke may induce effects on behavior and psychomotor skills, and have legal consequences, including the risk of being falsely considered as a cannabis user. This can become a concern, especially in occupational contexts or when driving vehicles. In order to enable a differentiation between a passive and an active exposure to cannabis and to limit the likeliness to be detected positive following passive exposure, this review identified specific biomarkers of passive exposure in urine, blood, oral fluid, hair, and sebum. Out of 958 papers identified on passive exposure to cannabis, 21 were selected. Although positive tests had been observed in all matrices following extremely high passive exposure, some distinctive features were observed in each matrix compared to cannabis active use. More specifically, in everyday life conditions, 11-nor-delta-9-THC-carboxylic acid (THC-COOH) urinary level should be detected below the positivity threshold used to confirm active smoking of cannabis, especially after normalization to creatinine level. Measuring delta-9-tetrahydrocannabinol (THC) and THC-COOH in blood is an appropriate alternative for appraising passive exposure as low and very low concentrations of THC and THC-COOH, respectively, should be measured. In hair, oral fluid (OF) and sweat/sebum emulsion, no THCCOOH should be detected. Its presence in hair argues for regular cannabis consumption and in OF or sweat for recent consumption. The experts should recommend to persons who have to demonstrate abstinence from cannabis to avoid heavily smoky and unventilated environments.
Topics: Biomarkers; Dronabinol; Hair; Humans; Marijuana Smoking; Saliva; Sweat; Tobacco Smoke Pollution
PubMed: 27883985
DOI: 10.1016/j.forsciint.2016.11.017 -
The Journal of Thoracic and... Nov 2019
Topics: Humans; Hyperhidrosis; Sweat; Sweating; Sympathectomy; Thoracic Surgical Procedures
PubMed: 31623816
DOI: 10.1016/j.jtcvs.2019.08.035 -
Biosensors Oct 2022Wearable sensors and invasive devices have been studied extensively in recent years as the demand for real-time human healthcare applications and seamless human-machine... (Review)
Review
Wearable sensors and invasive devices have been studied extensively in recent years as the demand for real-time human healthcare applications and seamless human-machine interaction has risen exponentially. An explosion in sensor research throughout the globe has been ignited by the unique features such as thermal, electrical, and mechanical properties of graphene. This includes wearable sensors and implants, which can detect a wide range of data, including body temperature, pulse oxygenation, blood pressure, glucose, and the other analytes present in sweat. Graphene-based sensors for real-time human health monitoring are also being developed. This review is a comprehensive discussion about the properties of graphene, routes to its synthesis, derivatives of graphene, etc. Moreover, the basic features of a biosensor along with the chemistry of sweat are also discussed in detail. The review mainly focusses on the graphene and its derivative-based wearable sensors for the detection of analytes in sweat. Graphene-based sensors for health monitoring will be examined and explained in this study as an overview of the most current innovations in sensor designs, sensing processes, technological advancements, sensor system components, and potential hurdles. The future holds great opportunities for the development of efficient and advanced graphene-based sensors for the detection of analytes in sweat.
Topics: Humans; Sweat; Graphite; Wearable Electronic Devices; Monitoring, Physiologic; Biosensing Techniques; Glucose
PubMed: 36291046
DOI: 10.3390/bios12100910