Journal of Physical Activity & Health Dec 2023Recent statistical approaches have allowed consideration of the integrated relationships between sedentary behavior (SB) and physical activity (PA) with different health... (Review)
Review
BACKGROUND
Recent statistical approaches have allowed consideration of the integrated relationships between sedentary behavior (SB) and physical activity (PA) with different health outcomes. The present paper aimed to systematically review the literature and synthesize evidence about associations between hypothetical reallocations from SB to different PA intensities and cardiovascular risk factors in youth.
METHODS
A systematic search of 8 databases was performed. Observational studies with a population of children and/or adolescents and based on statistical analysis that investigated the associations between time reallocations from SB to PA and cardiovascular risk factors were included.
RESULTS
Twenty-eight studies met the inclusion criteria. Level of evidence (derived from cross-sectional studies) indicated that the reallocation from SB to moderate to vigorous PA was beneficially associated with adiposity, cardiorespiratory fitness, and cardiometabolic biomarkers in youth. Reallocation from SB to light PA was not associated with the analyzed outcomes. Associations derived from longitudinal studies were mostly inconclusive.
CONCLUSION
Cardiovascular risk factors could be improved by increasing moderate to vigorous PA at the expense of time spent in SB in pediatric populations. Prospective studies or studies investigating the effects of reallocating sedentary bouts to PA are needed.
Topics: Humans; Adolescent; Child; Exercise; Cardiovascular Diseases; Sedentary Behavior; Cross-Sectional Studies; Prospective Studies; Risk Factors; Heart Disease Risk Factors; Accelerometry
PubMed: 37704195
DOI: 10.1123/jpah.2022-0471 -
Psychiatry Research Oct 2023Sleep disturbances are often linked to attention-deficit/hyperactivity disorder (ADHD). Consistent findings document that children and adolescents with ADHD report more... (Meta-Analysis)
Meta-Analysis Review
Sleep disturbances are often linked to attention-deficit/hyperactivity disorder (ADHD). Consistent findings document that children and adolescents with ADHD report more sleep problems than their typically developing (TD) peers across subjective sleep domains. However, few differences between these groups were observed in objectively measured sleep parameters, such as polysomnography (PSG) and actigraphy. This study synthesized empirical studies to identify objectively measured sleep continuity differences between children and adolescents with ADHD and TD. We included observational research and baseline data from intervention studies between 5- to 18-year-old individuals with ADHD and their TD peers at five databases from inception and September 2022. This systematic review and meta-analysis of 45 articles, including 1622 children and adolescents with ADHD and 2013 TD, found that compared with TD, children and adolescents with ADHD have higher sleep latency and moderately decreased sleep efficiency measured by actigraphy. Polysomnography-measured differences between ADHD and TD were not significant. Medication status and comorbid psychiatric status significantly moderated the group differences in sleep efficiency between ADHD and TD. Also, the group differences in sleep latency between ADHD and TD were moderated by actigraphy recorded nights. These findings highlight the importance of reducing disparities in sleep parameters among children and adolescents with and without ADHD.
Topics: Humans; Child; Adolescent; Child, Preschool; Attention Deficit Disorder with Hyperactivity; Sleep; Polysomnography; Actigraphy; Sleep Latency; Sleep Wake Disorders
PubMed: 37657199
DOI: 10.1016/j.psychres.2023.115447 -
Sleep Medicine Clinics Dec 2023This scoping review aimed to synthesize evidence on sleep disturbances in female shift workers. The update Preferred Reporting Items for Systematic Reviews and... (Review)
Review
This scoping review aimed to synthesize evidence on sleep disturbances in female shift workers. The update Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews was used. Twelve studies were included, four of which used actigraphy to assess sleep duration, efficiency, and latency. Seven studies evaluated the quality of sleep and three verified the sleepiness of women. This review adds to the body of evidence as the findings are homogeneous and allow a robust conclusion, suggesting that night shift work may be a potential factor for adverse effects on sleep of female shift workers.
Topics: Humans; Female; Shift Work Schedule; Sleep; Sleep Wake Disorders; Wakefulness; Actigraphy
PubMed: 38501525
DOI: 10.1016/j.jsmc.2023.06.016 -
Current Obesity Reports Dec 2023We summarized research on the bidirectional association between intake of ultra-processed food (UPF) and sleep. (Review)
Review
PURPOSE OF REVIEW
We summarized research on the bidirectional association between intake of ultra-processed food (UPF) and sleep.
RECENT FINDINGS
Sleep contributes to cardiometabolic health in part via food intake patterns. Restricting sleep increases intakes of high-carbohydrate/high-fat foods, a profile representative of UPF. This systematic review covers the association of UPF intake, as an exposure or an outcome, and sleep. UPF was defined as NOVA Group 4. MEDLINE and EMBASE were searched through April 2023 for epidemiological studies with general-population adult samples. Fifteen studies met the inclusion criteria; all were cross-sectional, published between 2016 and 2023, with samples from Brazil (n = 8), Spain (n = 2), Italy (n = 1), the UK (n = 1), Paraguay (n = 1), Iran (n = 1) and China (n = 1). Thirteen studies examined UPF intake as the exposure whereas two tested UPF intake as the outcome. UPF intakes were determined using food frequency questionnaires (73%) or 24-h recalls (27%). Two studies assessed sleep via accelerometry; the remaining studies relied on self-reports of sleep quality, duration, anxiety-induced insomnia, and napping, with 60% using a single question. The average methodological quality across the studies was deemed "fair". Six of the 13 studies that examined UPF consumption as the exposure revealed inverse associations with sleep outcomes in adjusted (n = 5) or bivariate (n = 1) analyses. Both studies addressing UPF consumption as the outcome and sleep as the exposure showed significant inverse associations. Evidence for UPF-sleep associations is accumulating, although sleep assessment limitations are apparent. This review can provide impetus for research using comprehensive and validated sleep measures and nudge policymakers towards refining dietary guidelines worldwide.
Topics: Adult; Humans; Diet; Food, Processed; Food Handling; Fast Foods; Sleep; Energy Intake
PubMed: 37477854
DOI: 10.1007/s13679-023-00512-5 -
Journal of Clinical Medicine Dec 2023Balance disturbances in people with lived experience of stroke affect activities of daily living and social participation, so assessing them is essential to know the... (Review)
Review
Balance disturbances in people with lived experience of stroke affect activities of daily living and social participation, so assessing them is essential to know the level of functional independence. Accelerometers are electronic devices that allow kinematic variables of balance to be recorded and are a tool of great interest in the assessment of functional balance. To determine the validity and reliability of, as well as the most performed protocols using accelerometers in the functional assessment of balance in people with experience of stroke, a systematic search of articles published in the electronic databases PubMed, Scopus, the Web of Science, the Cochrane Library, the PEDro and the Virtual Health Library from Spain was performed following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. We used QUADAS-2 to assess the quality of the included studies. Eight studies met the inclusion criteria, two studied reliability and validity, two studied reliability and four studied the validity of accelerometers in the assessment of balance in people with stroke. All studies indicated the kind of accelerometer, localization on the body, tests and outcome variables. The results indicate that accelerometers show excellent reliability values in the assessment of balance in people who had a prior stroke and disparate results in terms of validity. Triaxial accelerometers were most used, and the 4th and 5th lumbar and 1st and 2nd sacral vertebrae were the body areas most used for their placement.
PubMed: 38137771
DOI: 10.3390/jcm12247701 -
Aging & Mental Health 2023To analyze studies that investigated the association between physical activity assessed by accelerometry and cognitive function in older people. (Review)
Review
OBJECTIVE
To analyze studies that investigated the association between physical activity assessed by accelerometry and cognitive function in older people.
METHODS
A systematic review was carried out in four electronic databases (PubMed, Web of Science, Scopus, and SportsDiscus).
RESULTS
In total, 195 records were identified. Fifty-two studies were selected for a full evaluation; 23 were selected according to the inclusion criteria adopted and divided into four chapters (characteristics of the studies, the association between physical activity level and cognitive function decline, effects of physical activity in reducing the chances of cognitive function decline and effects of physical activity on brain plasticity. The cross-sectional studies had an average score of 7 points, and the cohort studies obtained 10 points, indicating the high quality of the selected studies. Seven studies indicated an association between Moderate to vigorous physical activities (MVPA) and cognitive function, two specifically indicated a reduction in the chances of cognitive function decline according to the interquartile of MVPA, and three studies indicated improvements in MVPA in brain plasticity.
CONCLUSION
Measured by accelerometry, seems to be favorably associated with important outcomes in cognitive function assessed through questionnaires, imaging analyses, and biochemical markers with older adults.
Topics: Humans; Aged; Cross-Sectional Studies; Cognition; Exercise; Cognitive Dysfunction; Accelerometry
PubMed: 37667883
DOI: 10.1080/13607863.2023.2248477 -
PeerJ 2024Disrupted circadian rhythm commonly reported in cancer survivors is closely associated with cancer related fatigue, sleep disturbances and compromised quality of life.... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Disrupted circadian rhythm commonly reported in cancer survivors is closely associated with cancer related fatigue, sleep disturbances and compromised quality of life. As more cancer survivors request non-pharmacological treatment strategies for the management of their chronic sleep-related symptoms, there is a need for meta-analyses of various interventions such as exercise on sleep and circadian rhythm disturbances.
METHODS
A search for RCT's was conducted in April 2020 and updated in July 2023 using relevant keywords for cancer, sleep, circadian rhythm and exercise interventions on PubMed, Scopus, Web of Science, PEDro and CINAHL.
RESULTS
Thirty-six studies were included for qualitative analysis and 26, for meta-analysis. Thirty-five studies analyzed sleep outcomes, while five analyzed circadian rhythm. RCT's studying the effect of aerobic exercise, resistance exercise, combined aerobic and resistance exercise, physical activity, yoga, or tai chi were included. Meta-analysis results showed significant exercise-related improvements on sleep quality assessed by Pittsburgh Sleep Quality index (PSQI) (SMD = -0.50 [-0.87, -0.13], = 0.008), wake after sleep onset (WASO) (SMD = -0.29 [-0.53, -0.05], = 0.02) and circadian rhythm, assessed by salivary cortisol levels (MD = -0.09 (95% CI [-0.13 to -0.06]) mg/dL, < 0.001). Results of the meta-analysis indicated that exercise had no significant effect on sleep efficiency, sleep onset latency, total sleep time and circadian rhythm assessed by accelerometry values.
CONCLUSION
While some sleep and circadian rhythm outcomes (PSQI, WASO and salivary cortisol) exhibited significant improvements, it is still somewhat unclear what exercise prescriptions would optimize different sleep and circadian rhythm outcomes across a variety of groups of cancer survivors.
IMPLICATION
As exercise does not exacerbate cancer-related circadian rhythm and sleep disturbances, and may actually produce some significant benefits, this meta-analysis provides further evidence for cancer survivors to perform regular exercise.
Topics: Humans; Cancer Survivors; Quality of Life; Hydrocortisone; Sleep; Neoplasms; Circadian Rhythm
PubMed: 38468641
DOI: 10.7717/peerj.17053 -
Journal of Medical Internet Research Jul 2023Wearable sensor technologies have the potential to improve monitoring in people with multiple sclerosis (MS) and inform timely disease management decisions. Evidence of... (Review)
Review
BACKGROUND
Wearable sensor technologies have the potential to improve monitoring in people with multiple sclerosis (MS) and inform timely disease management decisions. Evidence of the utility of wearable sensor technologies in people with MS is accumulating but is generally limited to specific subgroups of patients, clinical or laboratory settings, and functional domains.
OBJECTIVE
This review aims to provide a comprehensive overview of all studies that have used wearable sensors to assess, monitor, and quantify motor function in people with MS during daily activities or in a controlled laboratory setting and to shed light on the technological advances over the past decades.
METHODS
We systematically reviewed studies on wearable sensors to assess the motor performance of people with MS. We scanned PubMed, Scopus, Embase, and Web of Science databases until December 31, 2022, considering search terms "multiple sclerosis" and those associated with wearable technologies and included all studies assessing motor functions. The types of results from relevant studies were systematically mapped into 9 predefined categories (association with clinical scores or other measures; test-retest reliability; group differences, 3 types; responsiveness to change or intervention; and acceptability to study participants), and the reporting quality was determined through 9 questions. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) reporting guidelines.
RESULTS
Of the 1251 identified publications, 308 were included: 176 (57.1%) in a real-world context, 107 (34.7%) in a laboratory context, and 25 (8.1%) in a mixed context. Most publications studied physical activity (196/308, 63.6%), followed by gait (81/308, 26.3%), dexterity or tremor (38/308, 12.3%), and balance (34/308, 11%). In the laboratory setting, outcome measures included (in addition to clinical severity scores) 2- and 6-minute walking tests, timed 25-foot walking test, timed up and go, stair climbing, balance tests, and finger-to-nose test, among others. The most popular anatomical landmarks for wearable placement were the waist, wrist, and lower back. Triaxial accelerometers were most commonly used (229/308, 74.4%). A surge in the number of sensors embedded in smartphones and smartwatches has been observed. Overall, the reporting quality was good.
CONCLUSIONS
Continuous monitoring with wearable sensors could optimize the management of people with MS, but some hurdles still exist to full clinical adoption of digital monitoring. Despite a possible publication bias and vast heterogeneity in the outcomes reported, our review provides an overview of the current literature on wearable sensor technologies used for people with MS and highlights shortcomings, such as the lack of harmonization, transparency in reporting methods and results, and limited data availability for the research community. These limitations need to be addressed for the growing implementation of wearable sensor technologies in clinical routine and clinical trials, which is of utmost importance for further progress in clinical research and daily management of people with MS.
TRIAL REGISTRATION
PROSPERO CRD42021243249; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=243249.
Topics: Humans; Reproducibility of Results; Sclerosis; Wearable Electronic Devices; Gait; Exercise; Multiple Sclerosis
PubMed: 37498655
DOI: 10.2196/44428 -
Sensors (Basel, Switzerland) Sep 2023Measurement of real-world physical activity (PA) data using accelerometry in older adults is informative and clinically relevant, but not without challenges. This review... (Review)
Review
Measurement of real-world physical activity (PA) data using accelerometry in older adults is informative and clinically relevant, but not without challenges. This review appraises the reliability and validity of accelerometry-based PA measures of older adults collected in real-world conditions. Eight electronic databases were systematically searched, with 13 manuscripts included. Intraclass correlation coefficient (ICC) for were: walking duration (0.94 to 0.95), lying duration (0.98 to 0.99), sitting duration (0.78 to 0.99) and standing duration (0.98 to 0.99). ICCs for ranged from 0.24 to 0.82 for step counts and 0.48 to 0.86 for active calories. ranged from 5864 to 10,832 steps and for active calories from 289 to 597 kcal. ICCs for for step count were 0.02 to 0.41, and for active calories 0.07 to 0.93. for step count ranged from 0.83 to 0.98. Percentage of agreement for walking ranged from 63.6% to 94.5%; for lying 35.6% to 100%, sitting 79.2% to 100%, and standing 38.6% to 96.1%. between step count and criteria for moderate-to-vigorous PA was = 0.68 and 0.72. Inter-rater reliability and criterion validity for walking, lying, sitting and standing duration are established. Criterion validity of step count is also established. Clinicians and researchers may use these measures with a limited degree of confidence. Further work is required to establish these properties and to extend the repertoire of PA measures beyond "volume" counts to include more nuanced outcomes such as intensity of movement and duration of postural transitions.
Topics: Independent Living; Reproducibility of Results; Exercise; Walking; Accelerometry
PubMed: 37688071
DOI: 10.3390/s23177615 -
Journal of Science and Medicine in Sport Feb 2024To review cut-points calibrated and independently validated from wrist-worn ActiGraph accelerometers to measure moderate to vigorous physical activity (MVPA) and time... (Review)
Review
OBJECTIVES
To review cut-points calibrated and independently validated from wrist-worn ActiGraph accelerometers to measure moderate to vigorous physical activity (MVPA) and time spent sedentary (SED) in children and adolescents.
DESIGN
Systematic literature review.
METHODS
Five databases were searched for relevant cut-point calibration and independent validation studies relating to wrist worn ActiGraphs in children and adolescents from inception through 30 April 2022. Extracted data included: country of publication; study name; population; device model; wear location; sampling frequency; epoch length; activity protocol; criterion method and definitions used to classify PA intensity; statistical methods for calibration; statistical methods for validation/cross-validation; and MVPA and SED outcome.
RESULTS
Fourteen calibration studies and seven independent validation studies were identified. Calibrated cut-points for MVPA vector magnitude counts ranged from 7065 to 9204 counts per minute (cpm) and 63.5 to 201 milli-gravitational units (mg). For SED, calibrated cut-points ranged from <2556 cpm to 4350 cpm and 30.8 to 48.1 mg. Classification accuracy values determined by independent validation studies varied, with kappa values ranging from 0.31 to 0.60 and area under the curve statistics ranging from 0.51 to 0.84 for MVPA and kappa values ranging from 0.31 to 0.44 and area under the curve statistics ranging from 0.70 to 0.85 for SED.
CONCLUSIONS
The results of this systematic literature review support the use of the Crouter and colleagues cut-points for the measurement of MVPA and SED for children and adolescents aged 6-12 years. Further work is required to independently validate cut-points developed in younger children and older adolescents.
Topics: Child; Humans; Adolescent; Wrist; Exercise; Calibration; Wrist Joint; Research Design; Accelerometry
PubMed: 38087661
DOI: 10.1016/j.jsams.2023.11.008