-
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
The Journal of Prosthetic Dentistry Sep 2023Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are... (Review)
Review
STATEMENT OF PROBLEM
Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are currently unknown.
PURPOSE
The purpose of this systematic review was to evaluate the clinical and laboratory procedures for digital complete dentures, their outcomes, and associated complications.
MATERIAL AND METHODS
Electronic literature searches were conducted on PubMed/Medline, Embase, and Web of Science for studies published from January 2000 to September 2022 and screened by 2 independent reviewers. Information on digital complete denture procedures, materials, their outcomes, and associated complications was extracted.
RESULTS
Of 266 screened studies, 39 studies were included. While 26 assessed definitive complete dentures, 7 studies assessed denture bases, 2 assessed trial dentures, and 4 assessed the digital images only. Twenty-four studies used border molded impression technique, 3 studies used a facebow record, and 7 studies used gothic arch tracing. Only 13 studies performed trial denture placement. Twenty-one studies used milling, and 17 studies used 3D printing for denture fabrication. One study reported that the retention of maxillary denture bases fabricated from a border-molded impression (14.5 to 16.1 N) was statistically higher than the retention of those fabricated from intraoral scanning (6.2 to 6.6 N). The maximum occlusal force of digital complete denture wearers was similar across different fabrication procedures. When compared with the conventional workflow, digital complete dentures required statistically shorter clinical time with 205 to 233 minutes saved. Up to 37.5% of participants reported loss of retention and up to 31.3% required a denture remake. In general, ≥1 extra visit and 1 to 4 unscheduled follow-up visits were needed. The outcomes for patient satisfaction and oral health-related quality of life were similar between conventional, milled, and 3D-printed complete dentures.
CONCLUSIONS
Making a border-molded impression is still preferred for better retention, and trial denture placement is still recommended to optimize the fabrication of definitive digital complete dentures.
PubMed: 37689573
DOI: 10.1016/j.prosdent.2023.07.027 -
Journal of Prosthodontics : Official... Dec 2023To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans.
PURPOSE
To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans.
MATERIAL AND METHODS
A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the evaluation of ISB design on the accuracy of digital scans obtained by using IOSs were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. Articles were classified based on the ISB features of height, geometry, material, and retention system.
RESULTS
Twenty articles were included. Among the reviewed studies, 11 investigations analyzed the influence of different ISB geometries, 1 study assessed the impact of ISB diameter, 4 studies investigated the effect of ISB splinting, 2 articles evaluated ISB height, and 2 studies focused on the effect of ISB material on scan accuracy. In addition, 8 studies involved ISBs fabricated with different materials (1- and 2-piece polyetheretherketone and 1-piece titanium ISBs), and all of the reviewed articles tested screw-retained ISBs, except for 3 in vitro studies.
CONCLUSIONS
The findings did not enable concrete conclusions regarding the optimal ISB design, whether there is a relationship between IOS technology and a specific ISB design, or the clinical condition that maximizes intraoral scanning accuracy. Research efforts are needed to identify the optimal ISB design and its possible relationship with the IOS selected for acquiring intraoral digital implant scans.
Topics: Dental Implants; Imaging, Three-Dimensional; Dental Impression Technique; Computer-Aided Design; Models, Dental
PubMed: 37771200
DOI: 10.1111/jopr.13774 -
Journal of Prosthodontics : Official... Dec 2023To evaluate accuracy, scanning time, and patient satisfaction of photogrammetry (PG) systems for recording the 3D position of dental implants.
PURPOSE
To evaluate accuracy, scanning time, and patient satisfaction of photogrammetry (PG) systems for recording the 3D position of dental implants.
MATERIAL AND METHODS
A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the use of commercially available PG systems were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus.
RESULTS
A total of 14 articles were included: 3 in vivo, 6 in vitro, and 6 case report manuscripts. One clinical study evaluated trueness, another one tested precision, and the third one assessed impression time and patient and operator satisfaction. All the in vitro studies evaluated the trueness and precision of a PG system. Additionally, all the reviewed studies investigated completely edentulous conditions with multiple implants. The number of placed implants per arch among the reviewed clinical studies varied from 4 to 8 implants, while the number of implants placed on the reference casts included 4, 5, 6, or 8 implants. Not all the studies compared the accuracy of PG systems with conventional impression methods, using intraoral scanners as additional experimental groups. For the PIC system, trueness ranged from 10 to 49 μm and precision ranged from 5 to 65 μm. For the iCam4D system, trueness ranged from 24 to 77 μm and the precision value ranged from 2 to 203 μm.
CONCLUSIONS
PG systems may provide a reliable alternative for acquiring the 3D position of dental implants. However, this conclusion should be interpreted carefully, as one study reported a mean precision value of one PG system higher than the clinically acceptable discrepancy. Lower scanning time and higher patient and operator satisfaction have been reported when compared with conventional techniques. Further studies are needed to increase the evidence regarding the accuracy, scanning time, and patient and operator satisfaction of the commercially available PG systems.
Topics: Humans; Computer-Aided Design; Dental Implants; Dental Impression Technique; Imaging, Three-Dimensional; Models, Dental; Patient Satisfaction; Photogrammetry
PubMed: 37591510
DOI: 10.1111/jopr.13751 -
Cureus Jan 2024The accuracy of definitive impressions has a significant impact on the quality of the final prosthesis. Elastic impression materials are commonly used in the traditional... (Review)
Review
The accuracy of definitive impressions has a significant impact on the quality of the final prosthesis. Elastic impression materials are commonly used in the traditional approach to replicate anatomical structures while indirectly fabricating prostheses. Digital impression has gained increasing popularity due to its various advantages, including three-dimensional previsualization, cost-effectiveness, and reduced time consumption. The objective of this study is to evaluate existing studies to provide an overview of the comparative advantages of digital impression techniques over conventional techniques. The review will focus on evaluating the accuracy, patient acceptability, operator preference, and time effectiveness of digital impression techniques in comparison to conventional techniques. The Population, Intervention, Comparison, and Outcome framework served as the basis for this study's search strategy. We conducted a comprehensive literature review by electronically searching articles published between 2000 and 2023 in PubMed, Medline, Cochrane, and the Web of Science. Furthermore, additional manual searches were conducted. The study examined the differences between optical impressions and traditional impressions in terms of accuracy, patient outcomes, and operator outcomes. It included both clinical and preclinical studies as well as randomized controlled trials. In conclusion, this review provides a short summary indicating that digital impressions exhibit comparable accuracy to conventional impressions without any statistically significant difference. This conclusion is based on an evaluation of accuracy, patient preference, and operator preference.
PubMed: 38304652
DOI: 10.7759/cureus.51537 -
BMC Oral Health Jul 2023Polyvinyl ether siloxane (PVES) possesses ideal characteristics for making precise and accurate dental impressions. PVES dimensional stability owes to its better... (Meta-Analysis)
Meta-Analysis
BACKGROUND AND OBJECTIVES
Polyvinyl ether siloxane (PVES) possesses ideal characteristics for making precise and accurate dental impressions. PVES dimensional stability owes to its better polymeric properties derived from its parent materials poly ethers and polyvinyl siloxanes. As recommended use of chemical disinfecting agents is getting more popular, there is a growing concern associated with the effect of disinfectants on PVES dimensional stability. This study was aimed to understand the PVES behavior when subjected to chemical disinfectants.
MATERIALS AND METHODOLOGY
The data was collected from research studies retrieved from Google Scholar, Scopus, and PubMed using MeSH terms of keywords "vinyl polyether siloxane AND Disinfection" or (Vinyl polyether siloxane OR polyvinyl siloxane ether OR PVES) AND (disinfectant OR disinfection)" without any restriction to publication date. The PRISMA (Preferred Reporting Items for Systemic Review and Meta-Analysis) directions were observed during the data collection, screening of studies, and meta-analysis. The primary data were retrieved, and batch exported from databases using Harzing's Publish or Perish software; primary analysis was performed in Microsoft Excel, while statistical analysis for effect size, two-tailed p-values, and heterogeneity among studies was performed using Meta Essentials. The effect size was calculated using Hedge's g values at the 95% confidence level using the random-effects model. Heterogeneity among studies was measured using the Cochrane Q and I.
RESULTS AND CONCLUSION
Dental impressions made from the PVES elastomeric impression materials showed no significant changes in dimensional stability. Immersion in the chemical disinfectant for 10 min was associated with clinically irrelevant changes in the dimensions of the PVES impressions. Disinfection with sodium hypochlorite was associated with clinically significant changes in dimensions, with a two-tailed p-value of 0.049. Disinfection with 2-2.5% glutaraldehyde solution was not associated with any significant dimensional variability.
Topics: Humans; Disinfectants; Disinfection; Ether; Ethers; Ethyl Ethers; Polyvinyls; Siloxanes
PubMed: 37430254
DOI: 10.1186/s12903-023-03168-8 -
The Journal of Prosthetic Dentistry Jan 2024Time and cost are factors that influence a patient's decision on dental prosthetic treatment. Evidence is needed to demonstrate that restoration using digital systems is... (Review)
Review
STATEMENT OF PROBLEM
Time and cost are factors that influence a patient's decision on dental prosthetic treatment. Evidence is needed to demonstrate that restoration using digital systems is more rapid and less costly than the conventional process.
PURPOSE
The purpose of this systematic review was to analyze and compare the duration and cost of fixed dental prostheses fabricated using digital and conventional methods from scanning or impression making to delivery of the prosthesis.
MATERIAL AND METHODS
A systematic review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol (PRISMA-P 2015) guidelines. The analysis methods and inclusion criteria were documented in a protocol registered in the Prospective International Register of Systematic Reviews (PROSPERO) (CRD42023458734). The bibliographic search was carried out using PubMed, Cochrane, and PROSPERO databases. The main keywords used were (Prosthodontic OR restorative dentistry OR denture) AND (CAD CAM OR Digital workflow OR Computer Dentistry OR Digital Design) AND (Economic OR cost OR Financial OR time efficiency). Two investigators undertook the different steps of article selection.
RESULTS
A total of 8 articles published between 2010 and 2023 were found for the qualitative synthesis by using the search criteria. Two studies showed that conventional impressions took more time than digital scans for the fabrication of a single crown, and 1 study showed the opposite. One study found that a digital scan was faster than conventional impression making for the fabrication of a 3-unit fixed partial denture, and another study showed the opposite. The dental laboratory technician spent more time on the conventional workflow than the digital workflow for the 3-unit framework and veneering process. No difference was found between conventional and digital workflows for clinical evaluation and chairside adjustment for the fabrication of a single crown. No articles have compared the cost of fixed prostheses.
CONCLUSIONS
The digital pathway can shorten the laboratory process. However, the duration of the impression or scan may vary depending on the technique used. Studies are needed to analyze the cost-effectiveness of the fabrication of tooth-supported restorations.
PubMed: 38302291
DOI: 10.1016/j.prosdent.2024.01.003 -
Biomimetics (Basel, Switzerland) Mar 2024The popular immediate dentin sealing (IDS) technique is used to improve the bond strength of indirect restorations. This systematic review assessed whether bond strength... (Review)
Review
The popular immediate dentin sealing (IDS) technique is used to improve the bond strength of indirect restorations. This systematic review assessed whether bond strength is affected by the type of aging conditions, bonding agents, flowable resin composites, impression materials, temporary materials, and/or resin cement used within the IDS procedure. A comprehensive database search of PubMed, Embase, Scopus, Ovid Medline, Web of Sciences, Cochrane Library, Dentistry & Oral Sciences Source, and ProQuest was carried out up to 30 January 2024 without publication year or language limitations. Only in vitro full-texts regarding the effect of IDS on bond strength were included, and the quality of their methods was assessed via a Risk of Bias (RoB) test. In total, 1023 pertinent studies were initially found, and 60 articles were selected for review after screening for the title, abstract, and full texts. IDS application improves the bond strength of indirect restorations to dentin and reduces the negative effects of temporary materials on the bond durability of final indirect restorations. Filled dentin bonding agents or combinations with flowable resin composite are preferred to protect the IDS layer from conditioning procedures.
PubMed: 38534867
DOI: 10.3390/biomimetics9030182 -
BMC Oral Health Dec 2023The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications... (Meta-Analysis)
Meta-Analysis
PURPOSE OF THE STUDY
The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications using conventional impression methods improve the marginal and internal fit?
BACKGROUND
The incorporation of digital technology in the fabrication of fixed partial dentures (FPDs) has accelerated over the past decade. This study is directed at evaluating the marginal and internal fit of FPDs manufactured using digital approaches compared to conventional techniques. The need for updated data has encouraged this review.
MATERIALS AND METHODS
An electronic search was conducted in PubMed, Scopus, Web of Science, and the Grey Database to identify relevant studies. The Modified Methodological Index for Non-Randomized Studies (MINORS) was used to assess the risk of bias in in vitro experiments. The key results of this meta-analysis were the standard mean differences (SMDs) and 95% confidence intervals (CI) of each main variance, marginal fit, and internal fit between the digital and conventional techniques. Additional analyses were performed to assess the significance of three subgroup parameters: method of digitalization, cement spacer thickness, and span length, and their influence on the fit of the FPDs.
RESULTS
Based on predefined criteria, of the seven articles included in this systematic review, only five were selected for the quantitative data analysis. The marginal fit results were (P = 0.06; SMD: -1.88; 95% CI: - 3.88, 0.11) (P > 0.05) and the internal fit results were (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.10) (P < 0.05). Regarding the subgroup analyses, the method of digitalization subgroup results were (P = 0.35; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.80; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively. The span length results were (P = 0.10; SMD: -1.89; 95% CI: - 3.89, 0.11) for marginal fit and (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.11) for internal fit. The cement spacer thickness (P = 0.01; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.04; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively.
CONCLUSION
Tooth-retained fixed partial dentures FPDs produced by digital scanning and computer-aided design/computer-aided manufacturing (CAD/CAM) systems can significantly enhance the internal fit compared with those manufactured by traditional methods. Intraoral scanners can replace conventional impressions for the fabrication of FPDs because they minimize the operating time and reduce patient pain. Further clinical studies are required to obtain more conclusive results.
SYSTEMATIC REVIEW REGISTRATION
This systematic review and meta-analysis was registered in the International Prospective Register of Systematic Reviews (PROSPERO), registration number CRD42021261397.
Topics: Humans; Dental Marginal Adaptation; Denture, Partial, Fixed; Computer-Aided Design; Research Design; Dental Prosthesis Design
PubMed: 38049754
DOI: 10.1186/s12903-023-03628-1 -
Evidence-based Dentistry Sep 2023To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression.
MATERIALS AND METHODS
The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.
RESULTS
A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).
CONCLUSION
Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.
Topics: Humans; Dental Implants; Dental Prosthesis, Implant-Supported; Artificial Limbs; Prosthesis Implantation
PubMed: 37369705
DOI: 10.1038/s41432-023-00904-5