Evidence-based Dentistry Sep 2023To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression.
MATERIALS AND METHODS
The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.
RESULTS
A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).
CONCLUSION
Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.
Topics: Humans; Dental Implants; Dental Prosthesis, Implant-Supported; Artificial Limbs; Prosthesis Implantation
PubMed: 37369705
DOI: 10.1038/s41432-023-00904-5 -
Heliyon May 2024The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive... (Review)
Review
The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive manufacturing on their physical and mechanical properties?" This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the Open Science Framework (OSF) (osf.io/rdc84). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on February 17th, 2024. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: In vitro studies that evaluated the influence of the impression direction of titanium implants produced by additive manufacturing on their physical and mechanical properties were selected. Articles were excluded that (1) did not use additive technology to obtain the implants, 2) used surfaces other than titanium, 3) did not evaluate the direction of impression, 4) Studies with only in vivo analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports, and personal opinions.). In the initial search, 581 results were found. Of this total, 108 were excluded for duplication and, after applying the eligibility criteria, 16 articles were included in the present review. The risk of bias was analyzed using the RoBDEMAT. The risk of bias was analyzed using the RoBDEMAT. In addition, the coefficient of interagreement of the reviewers (Cohen's Kappa) and the certainty of evidence by GRADE were analyzed. In general, different impression angles showed variations in the physical and mechanical characteristics of the groups evaluated, including roughness, tensile strength, hardness, and modulus of elasticity. While some impression orientations resulted in greater strength or hardness, others showed greater elasticity or lower surface roughness. These findings suggest that print orientation plays a significant role in determining material properties. It can be concluded that printing directions influence the physical and mechanical properties of titanium implants and the studies included showed that the 0°, 45°, and 90° directions are the most evaluated as they present lower probabilities of structural anisotropies and provide better results in their roughness, hardness, tensile and compressive strength.
PubMed: 38774089
DOI: 10.1016/j.heliyon.2024.e30108 -
Clinical Implant Dentistry and Related... Mar 2024The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely... (Review)
Review
OBJECTIVES
The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely edentulous patients.
MATERIALS AND METHODS
Electronic searches were performed in PubMed, Embase and Cochrane CENTRAL up to December 1, 2023. Clinical studies and in vitro studies reporting the accuracy of digital full arch impressions were included. The primary outcome is the 3-dimensional deviations between the study reference models. A risk of bias assessment was performed for clinical studies. A stratified meta-analysis and a single-armed meta-analysis were conducted.
RESULTS
A total of 49 studies were included, with 8 clinical studies and 41 in vitro studies. For comparison between IOS and conventional impressions, studies were categorized into two groups based on the different measurement methods employed: RMS and CMM. In studies using RMS, the result favored the IOS in the unparalleled situation with the mean difference of -99.29 μm (95% CI: [-141.38, -57.19], I = 81%), while the result was opposite with the mean difference of 13.62 μm (95% CI: [10.97, 16.28], I = 26%) when implants were paralleled. For different brands of IOS, the accuracy ranged from 76.11 μm (95% CI: [42.36, 109.86]) to 158.63 μm (95% CI: [-14.68, 331.93]).
CONCLUSIONS
Accuracy of intraoral scan is clinically acceptable in edentulous arches, especially for unparalleled implants. More clinical studies are needed to verify the present finding.
PubMed: 38517307
DOI: 10.1111/cid.13321 -
International Journal of Implant... May 2024The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific... (Review)
Review
PURPOSE
The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs).
METHODS
Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes.
RESULTS
16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature.
CONCLUSIONS
The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.
Topics: Humans; Dental Implants; Imaging, Three-Dimensional; Computer-Aided Design; Dental Implantation, Endosseous; Dental Prosthesis Design
PubMed: 38691258
DOI: 10.1186/s40729-024-00543-0 -
Journal of Dentistry Nov 2023To review the factors that influence the accuracy of the maxillomandibular relationship at maximum intercuspation (MIP) acquired by using intraoral scanners (IOSs).
OBJECTIVE
To review the factors that influence the accuracy of the maxillomandibular relationship at maximum intercuspation (MIP) acquired by using intraoral scanners (IOSs).
MATERIAL AND METHODS
A systematic search was performed using five databases: MEDLINE/PubMed, Cochrane, Embase, World of Science, and Scopus. A manual search was also completed. Studies assessing the factors that influence the MIP acquired by using IOSs were included and organized based on the analyzed factor. Studies were evaluated by applying the Joanna Briggs Institute Critical Appraisal Checklist.
RESULTS
Twenty-nine articles were included. Seven factors have been identified: IOS system, scan extension, edentulous areas, number, location, and extension of occlusal records, occlusal force, tooth mobility, and alignment methods. Nine studies evaluated the influence of IOS system. Four studies assessed the influence of the extension of the arch scan. Three studies evaluated the effect of edentulous spaces. Four studies agreed on the impact of the number, location, and extension of the occlusal records on the MIP accuracy. One study assessed the influence of the occlusal force, showing a smaller average interocclusal space with increased occlusal force. One study evaluated the influence of tooth mobility. Seven studies analyzed the influence of the alignment method on the MIP accuracy.
CONCLUSIONS
Most of the studies reported no difference on the MIP accuracy between half- and complete-arch scans. Areas with 2 or more missing teeth reduce the MIP accuracy. A bilateral and frontal record including 2 teeth or a bilateral posterior occlusal including at least 4-teeth is indicated for maximizing the MIP accuracy.
CLINICAL IMPLICATIONS
When a complete-arch intraoral scans is obtained, a bilateral and frontal record including 2 teeth or a bilateral posterior occlusal record including at least 4-teeth is recommended for maximizing the accuracy of the MIP. When a half-arch intraoral scan is acquired, a posterior occlusal record including at least 4-teeth is indicated for optimizing the accuracy of the MIP.
Topics: Humans; Imaging, Three-Dimensional; Tooth Mobility; Dental Impression Technique; Models, Dental; Dental Arch; Mouth, Edentulous; Computer-Aided Design
PubMed: 37775027
DOI: 10.1016/j.jdent.2023.104718 -
The European Journal of Prosthodontics... Feb 2024Additive manufacturing is a tool with potential use in medicine and dentistry. The manufacture of metals and composites is already advanced, however, concerns about...
INTRODUCTION
Additive manufacturing is a tool with potential use in medicine and dentistry. The manufacture of metals and composites is already advanced, however, concerns about titanium hypersensitivity, tissue staining, and corrosion caused by gradual material degradation encourage research into more biocompatible alternatives.
OBJECTIVE
This systematic scoping review aimed to gather studies that evaluated zirconia implants produced by additive manufacturing to describe the current stage of the printing technique and the final product.
METHODS
Searches in Embase, PubMed, SCOPUS, Web of Science, and Google Scholar databases were enriched with manual searches between February and March 2021 and updated in June 2022 using keywords: zirconium implants, zirconium oxide, additive manufacturing, rapid prototyping, 3D printing, selective laser melting, and electron beam melting. The criteria included studies that evaluated or described zirconia implants obtained by 3D printing, with a direct relationship to dentistry or orthopedics.
RESULTS
The database search resulted in 671 articles. Eight articles were selected for full reading and remained in this systematic review.
CONCLUSION
The printing technique for zirconia implants is promising. However, further studies are required before implants produced by the printing technique can be tested clinically. The literature with results regarding the impression product is still limited.
Topics: Zirconium; Dental Implants; Printing, Three-Dimensional; Titanium
PubMed: 37721549
DOI: 10.1922/EJPRD_2513Kreve11 -
BMC Oral Health Jan 2024The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS)... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS) elastomers, has been a subject of interest in recent studies. This study aimed to assess the physical properties of hybrid PVES materials by analyzing existing data from recent studies on this topic.
METHODS
A systematic literature search was conducted to retrieve peer-reviewed articles published up to February 5, 2023. The population, intervention, comparison, and pertinent outcomes were specified under the PICO framework. The primary data analysis was performed in Microsoft Excel, while statistical analysis used Meta-Essentials.
RESULTS
Of the 1152 articles assessed, 14 met the inclusion criteria. The meta-analysis of the selected studies indicated that polyether (PE) and polyvinyl siloxane (PVS) were highly correlated (two-tailed p-values of 0.000 and 0.001, respectively) with the improved tensile strength of vinyl polyether siloxane (PVES) with a significantly positive effect size. Similarly, the hydrophilic characteristics of PVES were significantly improved compared to those of PE and PVS. PE was a significant contributor to the hydrophilic characteristics of PVES, with a two-tailed p-value of 0.000. The effect size was highly positive for hydrophilicity but showed high heterogeneity. It was also observed that the dimensional accuracy of PVES was comparable to those of PE and PVS, with no statistically significant differences among the three materials.
CONCLUSIONS
PVES showed promising features, with improved tensile strength and hydrophilic characteristics compared to those of PE and PVS.
Topics: Humans; Siloxanes; Polyethylene; Elastomers; Parents
PubMed: 38195442
DOI: 10.1186/s12903-023-03830-1