-
The Journal of Prosthetic Dentistry Apr 2024Data on the role of artificial intelligence (AI) in dental implant planning is insufficient. (Review)
Review
STATEMENT OF PROBLEM
Data on the role of artificial intelligence (AI) in dental implant planning is insufficient.
PURPOSE
The purpose of this systematic review with meta-analysis was to analyze and evaluate articles that assess the effectiveness of AI algorithms in dental implant planning, specifically in detecting edentulous areas and evaluating bone dimensions.
MATERIAL AND METHODS
A systematic review was conducted across the MEDLINE/PubMed, Web of Science, Cochrane, and Scopus databases. In addition, a manual search was performed. The inclusion criteria consisted of peer-reviewed studies that examined the accuracy of AI-based diagnostic tools on dental radiographs for dental implant planning. The most recent search was conducted in January 2024. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to assess the quality of the included articles.
RESULTS
Twelve articles met the inclusion criteria for this review and focused on the application of AI in dental implant planning using cone beam computed tomography (CBCT) images. The pooled data indicated an overall accuracy of 96% (95% CI=94% to 98%) for the mandible and 83% (95% CI=82% to 84%) for the maxilla in identifying edentulous areas for implant planning. Eight studies had a low risk of bias, 2 studies had some concern of bias, and 2 studies had a high risk of bias.
CONCLUSIONS
AI models have the potential to identify edentulous areas and provide measurements of bone as part of dental implant planning using CBCT images. However, additional well-conducted research is needed to enhance the accuracy, generalizability, and applicability of AI-based approaches.
PubMed: 38653687
DOI: 10.1016/j.prosdent.2024.03.032 -
The Journal of Prosthetic Dentistry Sep 2023Photogrammetry technology may be useful in implant dentistry, but a systematic review is lacking and is indicated before routine use in clinical practice. (Review)
Review
STATEMENT OF PROBLEM
Photogrammetry technology may be useful in implant dentistry, but a systematic review is lacking and is indicated before routine use in clinical practice.
PURPOSE
The purpose of this systematic review was to assess the role of the photogrammetry technology used in implant dentistry and determine its validity as an accurate tool with clinical applications.
MATERIAL AND METHODS
Four major databases, PubMed MEDLINE, Google Scholar, Scopus, and Web of Science, were selected to retrieve articles published from January 2011 to February 2021 based on custom criteria. The search was augmented by a manual search. After screening of the collected articles, data, including study design and setting, type of application, digitizer used, reference body, method of evaluation, and overall outcomes, were extracted.
RESULTS
Twenty articles were included based on the selection criteria. Most of the articles confirmed that the use of photogrammetry was promising as an implant coordinate transfer system. However, few articles showed its use for 3-dimensional scanning, which might require more development.
CONCLUSIONS
The initial reports of using photogrammetry technology considered this method as a valid and reliable clinical tool in implant dentistry. More studies to develop the photogrammetry technology and to assess the results with evidence-based research are recommended to enhance its application in different clinical situations.
Topics: Dental Implants; Photogrammetry; Databases, Factual
PubMed: 34801243
DOI: 10.1016/j.prosdent.2021.09.015 -
The Journal of Clinical Pediatric... Sep 2023The aim was to systematically evaluate the cost-effectiveness of pit and fissure sealants (PFSs) compared with that of fluoride varnishes (FVs) in dental caries...
The aim was to systematically evaluate the cost-effectiveness of pit and fissure sealants (PFSs) compared with that of fluoride varnishes (FVs) in dental caries prevention. We searched four electronic databases including the Cochrane Oral Health Group's Trials Register (till 03 June 2022), Web of Science (from 1945 to 03 June 2022), PubMed (from 1996 to 03 June 2022), and EMBASE Ovid (from 1980 to 03 June 2022) to identify the cost and effectiveness of PFSs and FVs in decreasing dental caries incidence. Two researchers independently screened search results, extracted data from the included studies, and conducted the risk of bias assessments. The main characteristics of the included studies were extracted and analyzed. The initial search produced 874 articles. After removing duplicates and full-text review, 19 studies were included. In this study: nine studies were on PFSs comparison with control; five on PFSs comparison with FVs; and five on FVs comparison with control. Regarding the type of economic evaluation (EE), 13 studies conducted cost-effectiveness analysis, five conducted cost-utility analyses, and one conducted both cost-effectiveness analysis and cost-utility analyses. The cost-effectiveness evaluation of PFSs and FVs in the available studies was limited. The prevalence of dental caries, payers' willingness to pay, length of follow-ups, delivery settings, retention rate of PFS, and application intervals of FV can affect the economic evaluation of these two methods for dental caries prevention. Therefore, more studies in the future are need to draw clear conclusions about which method is more cost-effective for the two preventive interventions in future.
Topics: Humans; Cost-Benefit Analysis; Fluorides, Topical; Pit and Fissure Sealants; Dental Caries; Cost-Effectiveness Analysis
PubMed: 37732430
DOI: 10.22514/jocpd.2023.048 -
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
Clinical Oral Implants Research Sep 2023In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year?
MATERIALS AND METHODS
This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487).
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material.
CONCLUSIONS
Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Topics: Humans; Titanium; Dental Implants; Alloys; Aluminum Oxide
PubMed: 37750527
DOI: 10.1111/clr.14159 -
BMC Oral Health Nov 2023The purpose of this study is to investigate the long-term efficacy and stability of Miniscrew-assisted Rapid Palatal Expansion (MARPE), including its primary outcomes,... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The purpose of this study is to investigate the long-term efficacy and stability of Miniscrew-assisted Rapid Palatal Expansion (MARPE), including its primary outcomes, namely the nasomaxillary complex transverse skeletal and dental expansion, and related secondary outcomes.
METHODS
Electronic databases and manual literature searches, up to October 31, 2022, were performed. The eligibility criteria were the following: studies on patients with transverse maxillary deficiency treated with MARPE in adults and adolescents over 13.5 years of age.
RESULTS
Ultimately, twelve articles were included in the analysis, one prospective and eleven retrospective observational studies. Five studies showed a moderate risk of bias, while the remaining seven studies were at a serious risk of bias. The GRADE quality of evidence was very low. MARPE is an effective treatment modality for transverse maxillary deficiency (mean success rate: 93.87%). Patients showed increased mean in the skeletal and dental transverse expansion. The basal bone composition, mean alveolar bone and mean dental expansion accounted for 48.85, 7.52, and 43.63% of the total expansion, respectively. There was a certain degree of skeletal and dental relapse over time. MARPE could also cause dental, alveolar, and periodontal side effects, and have an impact on other craniofacial bones, upper airway, and facial soft tissue.
CONCLUSIONS
MARPE is an effective treatment for transverse maxillary deficiency, with a high success rate and a certain degree of skeletal and dental relapse over time.
Topics: Humans; Adult; Adolescent; Retrospective Studies; Palatal Expansion Technique; Prospective Studies; Neoplasm Recurrence, Local; Palate; Recurrence; Maxilla; Cone-Beam Computed Tomography
PubMed: 37924088
DOI: 10.1186/s12903-023-03574-y -
The Journal of Prosthetic Dentistry Mar 2024The consequences of edentulism depend on its complexity and are far-reaching, but limited evidence regarding its association with neurologic health is available. (Review)
Review
STATEMENT OF PROBLEM
The consequences of edentulism depend on its complexity and are far-reaching, but limited evidence regarding its association with neurologic health is available.
PURPOSE
The purpose of this systematic review was to establish the relationship between oral prosthetic rehabilitation and the regional increase in brain activity.
MATERIAL AND METHODS
This systematic review was registered in the International Prospective Register of Systematic Reviews (CRD42021262247), and the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guideline was followed. Randomized clinical trials, prospective studies comparing the brain activity of patients rehabilitated with and without the use of dental prostheses, and studies that analyzed the human brain by using noninvasive techniques were used as inclusion criteria. The risk of bias in each study was assessed by using the Risk Of Bias In Non-randomized Studies-of Interventions (ROBINS-I).
RESULTS
The search was carried out in the PubMed/MEDLINE, Embase, Cochrane Library, and https://clinicaltrials.gov databases up to June 2021. After a search conducted by 2 reviewers, 8 articles were included in the review. A regional increase in blood flow and regional cerebral activity during dental prosthesis use was identified in the studies.
CONCLUSIONS
A positive association was found between the different types of prosthetic rehabilitation and brain function. Prostheses may preserve and restore neurological health.
Topics: Humans; Brain; Databases, Factual; Dental Prosthesis; Prosthesis Implantation
PubMed: 35305835
DOI: 10.1016/j.prosdent.2022.02.007 -
Clinical Oral Investigations Sep 2023The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium disilicate, leucite, and indirect composite materials.
MATERIAL AND METHODS
This systematic review and meta-analysis were conducted following the Cochrane Handbook for Systematic Reviews of Interventions and PRISMA guidelines. The protocol for this study was registered in PROSPERO (registration number: CRD42021233185). A comprehensive literature search was conducted across various databases and sources, including PubMed/Medline, Embase, Cochrane Library, Web of Science, ClinicalTrials.gov, and gray literature. A total of 7826 articles were screened on title and abstract. Articles were not excluded based on the vitality of teeth, the language of the study, or the observation period. The risk difference was utilized for the analyses, and a random-effects model was applied. All analyses were conducted with a 95% confidence interval (95% CI). The calculated risk differences were derived from the combined data on restoration survival and failures obtained from each individual article. The presence of heterogeneity was assessed using the I statistic, and if present, the heterogeneity of the data in the articles was evaluated using the non-parametric chi-squared statistic (p < 0.05).
RESULTS
A total of 12 eligible studies were selected, which included 946 restorations evaluated over a minimum observation period of 1 year and a maximum observation period of 7 years. Results of the meta-analysis indicated that intracoronal indirect resin composite restorations have an 18% higher rate of failure when compared to intracoronal gold restorations over 5-7 years of clinical service (risk difference = - 0.18 [95% CI: - 0.27, - 0.09]; p = .0002; I = 0%). The meta-analysis examining the disparity in survival rates between intracoronal gold and leucite restorations could not be carried out due to methodological differences in the studies.
CONCLUSIONS
According to the currently available evidence, medium-quality data indicates that lithium disilicate and indirect composite materials demonstrate comparable survival rates in short-term follow-up. Furthermore, intracoronal gold restorations showed significantly higher survival rates, making them a preferred option over intracoronal indirect resin-composite restorations. Besides that, the analysis revealed no statistically significant difference in survival rates between leucite and indirect composite restorations. The short observation period, limited number of eligible articles, and low sample size of the included studies were significant limitations.
CLINICAL SIGNIFICANCE
Bearing in mind the limitations of the reviewed literature, this systematic review and meta-analysis help clinicians make evidence-based decisions on how to restore biomechanically compromised posterior teeth.
Topics: Dental Porcelain; Aluminum Silicates; Composite Resins; Gold
PubMed: 37597003
DOI: 10.1007/s00784-023-05050-x -
The Journal of Prosthetic Dentistry Nov 2023Standard-diameter dental implants are not always applicable because of anatomic limitations of the residual ridge. Thus, mini-implants have been increasingly used and... (Meta-Analysis)
Meta-Analysis Review
STATEMENT OF PROBLEM
Standard-diameter dental implants are not always applicable because of anatomic limitations of the residual ridge. Thus, mini-implants have been increasingly used and offer an alternative. However, data regarding prosthetic complications, maintenance factors, and clinical outcomes are limited.
PURPOSE
The purpose of this systematic review and meta-analysis was to compare prosthetic complications and maintenance events and clinical outcomes in residual ridges rehabilitated with mandibular implant overdentures (IODs) by using standard implants or mini-implants.
MATERIAL AND METHODS
Nine electronic databases were searched. Quantitative analyses to measure the risk ratio (RR) and standardized mean difference (SMD) were applied. Those methods were used to assess prosthetic complications and maintenance events (abutment adjustments, replacement of retentive element, occlusal adjustment, and overdenture fracture) and clinical outcomes related to postoperative pain, probing depth (PD), plaque index (PI), marginal bone loss (MBL), and implant survival rate.
RESULTS
Altogether, 7 publications were selected. Mini-implants presented reduced abutment adjustments (RR 0.23 [0.07, 0.73], P=.01), replacement of retentive element (RR 0.41 [0.31, 0.54], P<.001), occlusal adjustment (RR 0.53 [0.31, 0.91], P=.02), and overdenture fracture (RR 0.46 [0.23, 0.94], P=.03) compared with standard implants. Additionally, mini-implants presented lower values for PI at 6 months (SMD -0.27 [-0.47, -0.08], P=.006) and 12 months (SMD -0.25 [-0.46, -0.05], P=.01). No additional tangible differences were noted.
CONCLUSIONS
Mini-implants might be an alternative choice based on the number of prosthetic complications and maintenance events. This was also confirmed by the comparable clinical data between standard implants and mini-implants.
Topics: Humans; Dental Implants; Denture, Overlay; Dental Prosthesis, Implant-Supported; Alveolar Bone Loss; Mandible
PubMed: 35120735
DOI: 10.1016/j.prosdent.2021.11.010