Journal of Dentistry Mar 2024This systematic review and network meta-analysis (NMA) aimed to establish a clinically relevant hierarchy of the different adhesive and/or restorative approaches to... (Meta-Analysis)
Meta-Analysis
AIM
This systematic review and network meta-analysis (NMA) aimed to establish a clinically relevant hierarchy of the different adhesive and/or restorative approaches to restore cavitated root caries lesions through the synthesis of available evidence.
MATERIALS AND METHODS
A systematic search was conducted in Medline/Web of Science/Embase/ Cochrane Library/Scopus/grey literature. RCTs investigating ≥2 restorative strategies (restorative /adhesive materials) for root caries lesions in adult patients were included. Risk of bias within studies was assessed (Cochrane_RoB-2) and the primary outcome was survival rate of restorations at different follow-up times (6-/12-/24-months). Network meta-analyses were conducted using a random effects model stratified by follow-up times. I-statistics assessed the ratio of true to total variance in the observed effects. All available combinations of adhesives (1-SE: one-step self-etch; 2-3ER: two-/three-step etch-and-rinse) and restorative materials (conventional composite (CC) as well as conventional and resin-modified glass ionomer cements (GIC, RMGIC)) were included. Risk of bias across studies and confidence in NMA (CINeMA) were assessed.
RESULTS
547 studies were identified and nine were eligible for the NMA. In total, 1263 root caries lesions have been restored in 473 patients in the included clinical trials. Patients involved were either healthy (n = 6 trials), living in nursing homes (n = 1 trial) or received head-and-neck radiotherapy (n = 2 trials). There was statistically weak evidence to favour either of material/material combination regarding the survival rate. A tendency for higher survival rate (24-months) was observed for 2-3ER/CC (OR 2.65; CI=1.45/4.84) as well as RMGIC (OR 2.05; CI=1.17/3.61) compared to GIC. These findings were though not statistically significant and confidence of the NMA was low.
CONCLUSION
An evidence-based choice of restorative strategy for managing cavitated root caries lesions is currently impossible. There is a clear need for more standardised, well-designed RCTs evaluating the retention rate of root caries restoration approaches.
Topics: Adult; Humans; Root Caries; Dental Cements; Network Meta-Analysis; Dental Restoration, Permanent; Dental Materials; Dental Caries; Glass Ionomer Cements; Composite Resins
PubMed: 37977410
DOI: 10.1016/j.jdent.2023.104776 -
The Journal of Prosthetic Dentistry Nov 2023Standard-diameter dental implants are not always applicable because of anatomic limitations of the residual ridge. Thus, mini-implants have been increasingly used and... (Meta-Analysis)
Meta-Analysis Review
STATEMENT OF PROBLEM
Standard-diameter dental implants are not always applicable because of anatomic limitations of the residual ridge. Thus, mini-implants have been increasingly used and offer an alternative. However, data regarding prosthetic complications, maintenance factors, and clinical outcomes are limited.
PURPOSE
The purpose of this systematic review and meta-analysis was to compare prosthetic complications and maintenance events and clinical outcomes in residual ridges rehabilitated with mandibular implant overdentures (IODs) by using standard implants or mini-implants.
MATERIAL AND METHODS
Nine electronic databases were searched. Quantitative analyses to measure the risk ratio (RR) and standardized mean difference (SMD) were applied. Those methods were used to assess prosthetic complications and maintenance events (abutment adjustments, replacement of retentive element, occlusal adjustment, and overdenture fracture) and clinical outcomes related to postoperative pain, probing depth (PD), plaque index (PI), marginal bone loss (MBL), and implant survival rate.
RESULTS
Altogether, 7 publications were selected. Mini-implants presented reduced abutment adjustments (RR 0.23 [0.07, 0.73], P=.01), replacement of retentive element (RR 0.41 [0.31, 0.54], P<.001), occlusal adjustment (RR 0.53 [0.31, 0.91], P=.02), and overdenture fracture (RR 0.46 [0.23, 0.94], P=.03) compared with standard implants. Additionally, mini-implants presented lower values for PI at 6 months (SMD -0.27 [-0.47, -0.08], P=.006) and 12 months (SMD -0.25 [-0.46, -0.05], P=.01). No additional tangible differences were noted.
CONCLUSIONS
Mini-implants might be an alternative choice based on the number of prosthetic complications and maintenance events. This was also confirmed by the comparable clinical data between standard implants and mini-implants.
Topics: Humans; Dental Implants; Denture, Overlay; Dental Prosthesis, Implant-Supported; Alveolar Bone Loss; Mandible
PubMed: 35120735
DOI: 10.1016/j.prosdent.2021.11.010 -
Journal of Oral Rehabilitation Dec 2023Adequate muscle activity is important for the success of oral rehabilitation: it maintains the integrity of the stomatognathic system and is responsible for chewing... (Review)
Review
BACKGROUND
Adequate muscle activity is important for the success of oral rehabilitation: it maintains the integrity of the stomatognathic system and is responsible for chewing movements needed to break, crush and grind food.
OBJECTIVE
To compare muscle activity using electromyography (EMG) while clenching or chewing soft and/or hard foods among individuals with natural dentition (ND) and edentulous patients rehabilitated with dental prostheses.
METHODS
This review was conducted until March, 2023, and the research question was "Is the muscle activity of edentulous patients rehabilitated with dental prostheses similar to that of dentate individuals?" A search strategy was conducted in PubMed/MEDLINE, The Cochrane Library, Web of Science, Lilacs, Embase and manual journal searches.
RESULTS
Ten studies were included in the analysis. Most of them reported that individuals with ND had significant higher muscle activity (clenching or chewing) than complete dentures (CD) users. However, no difference was observed between patients with full mouth implant-supported fixed dental prosthesis (ISFDP) and ND. Additionally, two studies compared patients with mandibular ISFDP with maxillary CD and individuals with ND and found no differences; however, one study concluded that patients with ISFDP with CD (maxillary or mandibular) had lower muscle activity than individuals with ND. Only one study reported a higher muscle activity in patients with full-mouth ISFDP than in individuals with ND.
CONCLUSIONS
Bimaxillary CD users had lower muscle activity than individuals with ND. During rehabilitation, the muscle activity of patients with full-mouth ISFDP and mandibular ISFDP with maxillary CD is similar to individuals with ND.
Topics: Humans; Dental Prosthesis, Implant-Supported; Mouth, Edentulous; Denture, Complete; Mastication; Muscles; Dental Implants; Denture, Overlay
PubMed: 37605296
DOI: 10.1111/joor.13564 -
Clinical Oral Implants Research Sep 2023This review evaluated the effects of rehabilitation with implant-supported prostheses on the oral function of completely edentulous adults. (Meta-Analysis)
Meta-Analysis
OBJECTIVES
This review evaluated the effects of rehabilitation with implant-supported prostheses on the oral function of completely edentulous adults.
MATERIALS AND METHODS
Systematic literature searches were performed to identify records reporting on oral function in completely edentulous adults rehabilitated with implant-supported prostheses. Meta-analyses were performed on various outcomes including bite force, masticatory performance, muscle activity, mandibular movement/chewing pattern, and salivary flow.
RESULTS
5507 records were identified. Thirty studies qualified for data extraction and analysis. The kappa (𝛋) for the search and identification strategy ranged between 0.50 and 1.00. Meta-analysis was performed grouping the studies by outcomes and split by time points of 6-12 months, 12-36 months, and >36 months after implant therapy. The meta-analyses revealed a significant improvement in oral function of completely edentulous adults after rehabilitation with implant-supported prostheses at 6-12 months (Z = -4.895, p < .001; 95% CI: -0.703, -0.301; τ = .609; Q = 114.953, df = 17, p < .001; I = 85.2%), at 12-36 months (Z = -4.886, p < .001; 95% CI: -0.580, -0.248; τ = .908; Q = 280.611, df = 35, p < .001; I = 87.5%) and at more than 36 months (Z = -9.108, p < .001; 95% CI: -1.472, -0.951; τ = .019; Q = 7.918, df = 7, p = .340; I = 11.6%). The included studies demonstrated a low to moderate risk of bias.
CONCLUSIONS
This systematic review concluded that the oral function of completely edentate adults significantly improved with implant-supported/retained prostheses, even when only one jaw received implant therapy. Therefore, implant therapy should be promoted for edentulous adults to alleviate the shortcomings of conventional complete removable dental prostheses.
Topics: Adult; Humans; Dental Prosthesis, Implant-Supported; Dental Implants; Bite Force; Mandible; Mastication; Mouth, Edentulous
PubMed: 37750517
DOI: 10.1111/clr.14068 -
The Journal of Prosthetic Dentistry Oct 2023Knowledge of the effectiveness of hydroxyapatite coatings on the surface of titanium dental implants is lacking because of difficulties in standardizing their thickness,... (Review)
Review
STATEMENT OF PROBLEM
Knowledge of the effectiveness of hydroxyapatite coatings on the surface of titanium dental implants is lacking because of difficulties in standardizing their thickness, roughness, and effect on osseointegration. The selection of articles describing this coating in osseointegration will be of great relevance to implant dentistry.
PURPOSE
This systematic review aimed to answer the question, "How effective is hydroxyapatite on titanium surfaces for osseointegration?"
MATERIAL AND METHODS
The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) 2020 guidelines were followed, and the protocol was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42023422601). The PubMed, Scopus, Web of Science, and Embase databases were searched, and articles were selected manually in 2 steps by 2 blinded investigators according to the previously selected eligibility criteria. The risk of bias was assessed using the systematic review center for laboratory animal experimentation (SYRCLE) tool.
RESULTS
Initially, 671 results were found. After analysis of eligibility criteria and full reading, 15 articles were included in the present review. Of these, 12 reported favorable osseointegration results for hydroxyapatite-coated surfaces, and 3 found no significant long-term difference between the coated and uncoated groups.
CONCLUSIONS
Hydroxyapatite surface treatment is effective in the osseointegration of titanium dental implants because it favors the absorption of proteins, adhesion, and proliferation of bone cells when obtained by methods that ensure proper adhesion. (J Prosthet Dent xxxx;xxx:xxx-xxx).
PubMed: 37845113
DOI: 10.1016/j.prosdent.2023.09.019 -
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
The Journal of Prosthetic Dentistry Mar 2024The consequences of edentulism depend on its complexity and are far-reaching, but limited evidence regarding its association with neurologic health is available. (Review)
Review
STATEMENT OF PROBLEM
The consequences of edentulism depend on its complexity and are far-reaching, but limited evidence regarding its association with neurologic health is available.
PURPOSE
The purpose of this systematic review was to establish the relationship between oral prosthetic rehabilitation and the regional increase in brain activity.
MATERIAL AND METHODS
This systematic review was registered in the International Prospective Register of Systematic Reviews (CRD42021262247), and the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guideline was followed. Randomized clinical trials, prospective studies comparing the brain activity of patients rehabilitated with and without the use of dental prostheses, and studies that analyzed the human brain by using noninvasive techniques were used as inclusion criteria. The risk of bias in each study was assessed by using the Risk Of Bias In Non-randomized Studies-of Interventions (ROBINS-I).
RESULTS
The search was carried out in the PubMed/MEDLINE, Embase, Cochrane Library, and https://clinicaltrials.gov databases up to June 2021. After a search conducted by 2 reviewers, 8 articles were included in the review. A regional increase in blood flow and regional cerebral activity during dental prosthesis use was identified in the studies.
CONCLUSIONS
A positive association was found between the different types of prosthetic rehabilitation and brain function. Prostheses may preserve and restore neurological health.
Topics: Humans; Brain; Databases, Factual; Dental Prosthesis; Prosthesis Implantation
PubMed: 35305835
DOI: 10.1016/j.prosdent.2022.02.007 -
Evidence-based Dentistry Sep 2023A systematic appraisal and statistical aggregation of primary studies in humans. (Meta-Analysis)
Meta-Analysis
DESIGN
A systematic appraisal and statistical aggregation of primary studies in humans.
DATA SOURCES
The researchers utilized PubMed (Medline) and Scopus databases as the primary data sources for this study. They performed a comprehensive literature search based on free keywords and Medical Subject Heading (MeSH) terms to enhance the search accuracy. The database search was concluded on November 13, 2022. Furthermore, a meticulous examination of the references cited in the selected studies was conducted to identify additional relevant articles that could be incorporated into the analysis.
STUDY SELECTION
The systematic review focused on partially or fully edentulous patients receiving dental implants and aimed to determine if the lack of keratinized mucosa at the implant site increased the risk of peri-implantitis compared to patients with adequate keratinized mucosa. Human studies with a minimum of 100 implants, cross-sectional, cohort, or case-control designs, and a follow-up period of at least one year were included. Studies lacking a clear case definition or information on peri-implantitis and those that did not investigate keratinized mucosa as a risk indicator were excluded.
DATA EXTRACTION AND SYNTHESIS
Two reviewers independently utilized a systematic review screening website (Rayyan, Qatar Computing Research Institute, Qatar Foundation) to select potential articles, and conflicts were resolved through discussion or consultation with a third reviewer. The data extraction process involved recording information from the included articles, such as study design, patient and implant numbers, prosthesis type (fixed or removable), follow-up duration, peri-implantitis case definition, prevalence at patient and implant levels, keratinized mucosa cutoff value, odds ratio (OR) of peri-implantitis considering keratinized mucosa, and conclusions on the potential effect of keratinized mucosa from each study. The Newcastle Ottawa scale (NOS) and a modified version of NOS were used, respectively, to assess the quality of cohort and cross-sectional studies. Studies scoring below 6 out of 9 points were classified as low quality. For the meta-analysis, the relationship between peri-implantitis and keratinized mucosa was evaluated using the odds ratio (OR) and standard error (SE). Heterogeneity was assessed through the Chi test and I index, determining whether a random-effects or fixed-effects model should be applied. Subgroup and cluster analyses were conducted based on specific criteria, and forest plots and funnel plots were generated to visualize results and identify potential study bias. Sensitivity analysis was performed to verify the robustness of the meta-analysis, with statistical significance set at p < 0.05. The Review Manager (RevMan) software facilitated data analysis. The GRADE rating system was used to determine the level of evidence, considering factors such as bias risk, imprecision, inconsistency, indirectness, and publication bias. The certainty of the evidence was evaluated based on the overall outcomes of analyzed subgroups.
RESULTS
Twenty-two primary studies were identified, and a meta-analysis was conducted on 16 cross-sectional studies. The prevalence of peri-implantitis ranged from 6.68% to 62.3% at the patient level and from 4.5% to 58.1% at the implant level. The overall analysis revealed a significant association between the lack of keratinized mucosa and a higher prevalence of peri-implantitis (OR = 2.78, 95% CI 2.07-3.74, p < 0.00001). Subgroup analyses with a consistent case definition of peri-implantitis (MBL ≥ 2 mm) showed similar results (OR = 1.96, 95% CI 1.41-2.73, p < 0.0001). Studies focusing on fixed prostheses only demonstrated that the lack of keratinized mucosa was associated with an increased prevalence of peri-implantitis (OR = 2.82, 95% CI 1.85-4.28, p < 0.00001). Among patients under regular implant maintenance, the absence of keratinized mucosa significantly raised the occurrence of peri-implantitis (OR = 2.08, 95% CI 1.41-3.08, p = 0.0002). Studies adjusting for other variables also confirmed a higher risk of peri-implantitis with inadequate keratinized mucosa (OR = 3.68, 95% CI 2.32-5.82, p = 0.007). Although some publication bias was observed, the certainty of evidence based on the GRADE system was judged to be "moderate."
CONCLUSIONS
The lack of keratinized mucosa increased the risk of peri-implantitis, emphasizing the need to consider it during dental implant placement. Inadequate data on patient-specific factors and the predominance of cross-sectional studies influenced the evidence quality (i.e., moderate). Future studies with consistent methodologies shall confirm these findings and identify additional risk indicators to improve implant dentistry practices.
Topics: Humans; Peri-Implantitis; Dental Implants; Cross-Sectional Studies; Mucous Membrane; Risk Factors
PubMed: 37537217
DOI: 10.1038/s41432-023-00913-4 -
Clinical Oral Investigations Oct 2023To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia... (Review)
Review
Clinical outcomes of tooth-supported monolithic zirconia vs. porcelain-veneered zirconia fixed dental prosthesis, with an additional focus on the cement type: a systematic review and meta-analysis.
PURPOSE
To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia (PVZ) fixed dental prosthesis, based on a systematic literature review.
METHODS
An electronic search was performed in three databases, supplemented by hand searching. Several statistical methods were used.
RESULTS
Seventy-four publications reported 6370 restorations (4264 PVZ; 2106 MZ; 8200 abutment teeth; 3549 patients), followed up until 152 months. A total of 216 prostheses failed, and survival was statistically significant different between groups. PVZ had higher occurrence of complications than MZ; the difference was especially greater for either minor or major chipping. The difference in prevalence of either minor or major chipping was statistically significant for PVZ prostheses between cementation with glass ionomer and adhesive resin cement (higher), adhesive resin and resin-modified glass ionomer cement (RMGIC, higher), and between RMGIC (higher) and glass ionomer cement. For MZ the difference was significant only for minor chipping between RMGIC (higher) and adhesive resin cement. Abutment teeth to PVZ prostheses more often lost vitality. Decementation was not observed with RMGIC. Air abrasion did not seem to clinically decrease the decementation risk. The 5-year difference in the occurrence of minor or major chipping between MZ and PVZ prostheses was statistically significant, but nor for catastrophic fracture.
CONCLUSION
Tooth-supported PVZ prostheses present higher failure and complication rates than MZ prosthesis. The difference in complications is striking when it comes to chipping.
CLINICAL RELEVANCE
Awareness of the outcome differences between different types of zirconia prostheses is important for clinical practice.
PubMed: 37626273
DOI: 10.1007/s00784-023-05219-4