Journal of Prosthodontics : Official... Dec 2023To evaluate accuracy, scanning time, and patient satisfaction of photogrammetry (PG) systems for recording the 3D position of dental implants.
PURPOSE
To evaluate accuracy, scanning time, and patient satisfaction of photogrammetry (PG) systems for recording the 3D position of dental implants.
MATERIAL AND METHODS
A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the use of commercially available PG systems were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus.
RESULTS
A total of 14 articles were included: 3 in vivo, 6 in vitro, and 6 case report manuscripts. One clinical study evaluated trueness, another one tested precision, and the third one assessed impression time and patient and operator satisfaction. All the in vitro studies evaluated the trueness and precision of a PG system. Additionally, all the reviewed studies investigated completely edentulous conditions with multiple implants. The number of placed implants per arch among the reviewed clinical studies varied from 4 to 8 implants, while the number of implants placed on the reference casts included 4, 5, 6, or 8 implants. Not all the studies compared the accuracy of PG systems with conventional impression methods, using intraoral scanners as additional experimental groups. For the PIC system, trueness ranged from 10 to 49 μm and precision ranged from 5 to 65 μm. For the iCam4D system, trueness ranged from 24 to 77 μm and the precision value ranged from 2 to 203 μm.
CONCLUSIONS
PG systems may provide a reliable alternative for acquiring the 3D position of dental implants. However, this conclusion should be interpreted carefully, as one study reported a mean precision value of one PG system higher than the clinically acceptable discrepancy. Lower scanning time and higher patient and operator satisfaction have been reported when compared with conventional techniques. Further studies are needed to increase the evidence regarding the accuracy, scanning time, and patient and operator satisfaction of the commercially available PG systems.
Topics: Humans; Computer-Aided Design; Dental Implants; Dental Impression Technique; Imaging, Three-Dimensional; Models, Dental; Patient Satisfaction; Photogrammetry
PubMed: 37591510
DOI: 10.1111/jopr.13751 -
Journal of Dentistry Nov 2023To compare the clinical performance (retention, secondary caries, marginal adaptation, marginal discoloration, and postoperative hypersensitivity) of self-adhesive... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
To compare the clinical performance (retention, secondary caries, marginal adaptation, marginal discoloration, and postoperative hypersensitivity) of self-adhesive flowable composite resins (SAFCs) and flowable composite resins (FCs) in permanent teeth with occlusal cavities.
DATA
Randomized controlled trials (RCTs) of SAFCs versus FCs with a follow-up length of at least one year. No restrictions were placed on language or publication date.
SOURCES
Five databases, including PubMed, Embase, Web of Science, Scopus, and the Cochrane Central Register of Controlled Trials, were searched manually by browsing ten related journals. On 14 June 2023, all electronic and manual searches were updated.
STUDY SELECTION
Five RCTs with 138 participants were included. Cochrane's risk of bias tool (2.0) was implemented in selected studies, and the GRADE tool was utilised to evaluate the evidence quality. To summarize the effects of the treatments and pool the data, a random-effects model was used.
CONCLUSIONS
According to the modified United States Public Health Service Evaluation (USPHS) criteria, there was no discernible difference between the groups during the two-year follow-up period (maximum follow-up time). Nevertheless, FCs applied with the etch-and-rinse mode demonstrated superior marginal adaptation and marginal discoloration at the two-year follow-up (relative risk = 3.21 [1.50 to 6.83], 3.40 [1.10, 10.48]). The evidence for marginal discoloration at any recall time and marginal adaptation at the one-year follow-up was graded as moderate quality due to inconsistency. Moreover, low-quality evidence for marginal adaptation at two-year follow-up was due to imprecision and inconsistency.
CLINICAL SIGNIFICANCE
SAFCs exhibited clinical performance comparable to that of FCs in occlusal cavities. Further high-quality clinical trials are needed to provide solid evidence to support the clinical application of SAFCs.
REGISTRATION
PROSPERO (CRD42022374983).
Topics: Humans; Resin Cements; Dental Cements; Composite Resins; Dentition, Permanent; Dental Caries; Dental Marginal Adaptation; Dental Restoration, Permanent
PubMed: 37683798
DOI: 10.1016/j.jdent.2023.104691 -
Supportive Care in Cancer : Official... May 2024This study is to conduct a comprehensive scoping review to map scientific evidence and clarify concepts regarding the commonly recommended preventive and restorative... (Review)
Review
PURPOSE
This study is to conduct a comprehensive scoping review to map scientific evidence and clarify concepts regarding the commonly recommended preventive and restorative dental treatments for patients diagnosed with head and neck cancer (HNC) and subjected to radiotherapy.
MATERIAL AND METHODS
This systematic scoping review was performed under the PRISMA-ScR guidelines. The study's experimental design was registered in the Open Science Framework. In vitro studies that evaluated preventive and restorative dental treatment over 50 Gy radiation doses were included. The search was conducted in November 2023 in five electronic databases (PubMed, Scopus, Web of Science, Cochrane Library, and Embase) without language or date restriction. A search strategy was applied based on keywords, MeSh terms, or synonyms. A descriptive analysis was conducted.
RESULTS
A total of 49 studies, out of 3679 original articles identified, were included and reviewed. Of the included studies, three evaluated saliva stimulants and 35 evaluated fluoride-based preventive materials: gel (n = 18) toothpaste (n = 11) mouth rinse (n = 8) and varnish (n = 5) while 14 evaluated restorative materials: resin composite (n = 12) glass ionomer cement (n = 6) and amalgam (n = 1) Of those studies, 36 were clinical trials and 13 were in vitro studies.
CONCLUSION
Fluoride gel was the most frequently recommended preventive material for preventing radiation caries with supportive clinical evidence. Resin composite and glass ionomer were the most frequently used restorative materials, respectively. However, there is not yet clinical evidence to support the use of resin composite in irradiated teeth.
Topics: Humans; Dental Caries; Head and Neck Neoplasms; Dental Restoration, Permanent
PubMed: 38702458
DOI: 10.1007/s00520-024-08522-2 -
Journal of Endodontics Jun 2024This systematic review and meta-analysis aimed to evaluate the clinical and radiographic failure of nonsurgical endodontic treatment and retreatment for mature permanent... (Meta-Analysis)
Meta-Analysis Review
Clinical and Radiographic Failure of Nonsurgical Endodontic Treatment and Retreatment Using Single-cone Technique With Calcium Silicate-based Sealers: A Systematic Review and Meta-analysis.
INTRODUCTION
This systematic review and meta-analysis aimed to evaluate the clinical and radiographic failure of nonsurgical endodontic treatment and retreatment for mature permanent teeth with or without apical periodontitis using the single-cone (SC) obturation technique with calcium silicate-based bio-ceramic (CSBC) sealers and to compare these failure rates to other sealer materials and obturation techniques.
METHODS
A comprehensive search was conducted using MEDLINE (PubMed), Embase, Cochrane Library, Scopus, Web of Science, and gray literature up to March 2023. Two reviewers assessed the eligibility of the included studies. Eligible studies were critically appraised for risk of bias and quality of evidence. Subsequently, a meta-analysis of pooled data was conducted utilizing the RevMan software (P < .05) to evaluate the failure rate of non-surgical root canal therapy using CSBC sealers and SC obturation procedures. Separately, another analysis was conducted to compare those results with the outcome of nonsurgical root canal therapy using alternative obturation materials and methods.
RESULTS
Five studies were included. The pooled failure rate for nonsurgical endodontic treatment and retreatment combined using CSBC sealers and SC obturation technique was 6.8% [95% confidence interval (CI) = (3%-12%), I = 46%]. A second analysis was conducted on the 3 included clinical trials to compare the outcomes of the intervention (CSBC sealers and SC obturation technique) and control groups (other sealers and other obturation techniques). This analysis found no significant difference between the 2 groups regarding clinical and radiographic failure of endodontic treatment and retreatment [Risk ratio = 0.71, 95% CI = (0.33, 1.51), I = 0]. This difference was also not statistically significant when the failure rate of primary root canal treatment and retreatment were separately analyzed [Combined Risk ratio of primary root canal treatment = 0.94, 95% CI = (0.46, 1.93), I = 0%; Combined Risk ratio of retreatment = 0.21, 95% CI = (0.001, 75.46), I = 0%].
CONCLUSIONS
The overall results of this systematic review and meta-analysis demonstrate that the SC obturation technique with CSBC sealer provides similar results compared to other obturation materials and techniques in facilitating the healing of apical periodontitis.
Topics: Humans; Calcium Compounds; Dental Restoration Failure; Periapical Periodontitis; Retreatment; Root Canal Filling Materials; Root Canal Obturation; Root Canal Therapy; Silicates; Treatment Failure
PubMed: 38548045
DOI: 10.1016/j.joen.2024.03.007 -
Clinical Oral Investigations Dec 2023The aim of this systematic review was to compare the expectation and perception of pain reported by patients before and after the installation of interradicular... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review was to compare the expectation and perception of pain reported by patients before and after the installation of interradicular mini-implants.
MATERIALS AND METHODS
Electronic search was performed in six databases. Inclusion criteria were randomized controlled trials (RCTs) or non-randomized controlled clinical trials (nRCTs); studies using mini-implants in the interradicular region; assessment of pain intensity by visual analogue or numerical scale. The risk of bias assessment was based on the Rob 2 tool and Robins-I.
RESULTS
A total of 1566 articles were retrieved, and 21 met the eligibility criteria. Six were classified as high risk, one as critical and the other one as uncertain, according to the Robins-I tool. In articles evaluated by the Rob2 tool, ten were classified as serious risk and three as moderate risk. A meta-analysis was also performed. Weighted means were calculated among the studies using the random-effects model and forest plots were generated. Heterogeneity was assessed through the Q test and I statistics. It was observed, with moderate evidence, that on a scale of 0 to 10, the pain expectation (effect size 4.75) is higher than that effectively pain generated by the procedure (effect size 1.94).
CONCLUSION
Pain expectation was greater than that actually generated by the procedure, being almost non-existent 7 days postoperatively.
CLINICAL RELEVANCE
This study may help the clinician to reassure the patient regarding the sensations that could be experienced during and after the installation.
Topics: Humans; Motivation; Dental Implants; Pain; Pain Perception
PubMed: 37864604
DOI: 10.1007/s00784-023-05311-9 -
Clinical and Experimental Dental... Dec 2023The aim of the systematic review was to compare studies on implant-supported two-unit cantilever crowns with two adjacent implant-supported crowns in the anterior...
OBJECTIVES
The aim of the systematic review was to compare studies on implant-supported two-unit cantilever crowns with two adjacent implant-supported crowns in the anterior region. The second aim was to assess in a 10-year prospective comparative pilot study, hard and soft peri-implant tissue changes in patients with a missing central and adjacent lateral upper incisor, treated with either an implant-supported two-unit cantilever crown or two single implant-supported crowns.
MATERIALS AND METHODS
Medline, Embase, and the Cochrane Central Register of Controlled Trials were searched (last search March 1, 2023). Inclusion criteria were studies reporting outcomes of two missing adjacent teeth in the esthetic region and treated with a single implant-supported two-unit cantilever fixed dental prosthesis, or with two solitary implant-supported crowns. Outcome measures assessed included implant survival (primary), changes in marginal bone and gingiva level, restoration survival, subjective and objective esthetic scores, papilla volume, mid-facial marginal mucosa level, probing depth, bleeding on probing, and biological and technical complications with ≥1-year follow-up. In addition, in a 10-year pilot study, the same outcome measures were assessed of five patients with a single implant-supported two-unit cantilever crown and compared with five patients with two adjacent single implant-supported crowns in the esthetic zone.
RESULTS
Nine articles with 11 study groups were found eligible for data extraction. Meta-analyses of implant survival rates were 96.9% (mean follow-up 3.4 ± 1.4 years) for the implant-cantilever treatment and 97.6% (mean follow-up 3.0 ± 1.8 years) for the adjacent implants treatment (p = .79). In the 10-year comparative pilot study, no clinically relevant changes in hard and soft peri-implant tissue levels occurred in both groups. Patient satisfaction was also high in both groups.
CONCLUSION
Single implant-supported two-unit crowns can be a viable alternative to the placement of two adjacent single implant crowns in the esthetic zone.
Topics: Humans; Dental Implants; Treatment Outcome; Pilot Projects; Dental Implants, Single-Tooth; Prospective Studies; Esthetics, Dental
PubMed: 37592440
DOI: 10.1002/cre2.773 -
International Journal of Implant... Dec 2023This systematic review aimed to investigate the accuracy of intraoral scan (IOS) impressions of implant-supported restorations in in vivo studies. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
This systematic review aimed to investigate the accuracy of intraoral scan (IOS) impressions of implant-supported restorations in in vivo studies.
METHODS
A systematic electronic search and review of studies on the accuracy of IOS implant impressions were conducted to analyze the peer-reviewed literature published between 1989 and August 2023. The bias analysis was performed by two reviewers. Data on the study characteristics, accuracy outcomes, and related variables were extracted. A meta-analysis of randomized control trials was performed to investigate the impact of IOS on peri-implant crestal bone loss and the time involved in the impression procedure.
RESULTS
Ten in vivo studies were included in this systematic review for final analysis. Six studies investigated the trueness of IOS impressions, but did not reach the same conclusions. One study assessed the precision of IOS impressions for a single implant. Four clinical studies examined the accuracy of IOS implant impressions with a follow-up of 1-2 years. In full arches, IOS impression procedure needed significantly less time than conventional one (mean difference for procedure time was 8.59 min [6.78, 10.40 min], P < 0.001), prosthetic survival rate was 100%, and marginal bone levels of all participants could be stably maintained (mean difference in marginal bone loss at 12 months was 0.03 mm [-0.08, 0.14 mm], P = 0.55).
CONCLUSIONS
The accuracy of IOS impressions of implant-supported restorations varied greatly depending on the scanning strategy. The trueness and precision of IOS in the partial and complete arches remain unclear and require further assessment. Based on follow-up clinical studies, IOS impressions were accurate in clinical practice. However, these results should be interpreted with caution, as some evidences are obtained from the same research group.
Topics: Humans; Dental Implants; Research Design; Bone Diseases, Metabolic; Clonal Hematopoiesis; Electronics
PubMed: 38055096
DOI: 10.1186/s40729-023-00517-8 -
Clinical Oral Implants Research Sep 2023To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on dental patient-reported outcomes (dPROs).
MATERIALS AND METHODS
In January 2022, Medline, Embase, CINAHL, Cochrane Library, PubMed Central, Web of Science, and ClinicalTrials.gov were screened for prospective clinical studies on completely edentulous patients treated with IFCDs and/or IODs, reporting pre-treatment and follow-up dPROs. Hedges' g effect sizes (ES) with corresponding 95% confidence intervals (CI) were calculated. Afterward, meta-analyses were conducted using random effect models.
RESULTS
A total number of 1608 records was initially identified. Of those, 28 studies reporting dPROs from 1457 patients were finally included. The applied dental patient-reported outcome measures (dPROMs) included several versions of the Oral Health Impact Profile (OHIP) or specific items assessing satisfaction with Visual Analogue Scales (VAS). The overall ES was large for rehabilitation with IFCDs (1.68 [CI: 1.15, 2.20]) and IODs (1.26 [CI: 0.99, 1.52]) with no significant difference (p = .165) between the two. Denture stability was the only factor rated significantly higher for IFCDs (ES difference: 2.37 [CI: 0.21, 4.54]; p = .032). Subgroup analyses revealed moderately higher ES for IODs on two implants relative to one implant (ES difference: 0.73 [CI: 0.34, 1.12]; p < .001).
CONCLUSIONS
There is a strong positive effect of implant treatment in edentulous patients, independent of the type of prosthetic rehabilitation. In patients seeking high stability, IFCDs may be preferable. In mandibular IODs on a single implant, there was a significantly positive effect of an additional implant on dPROs.
Topics: Humans; Denture, Overlay; Prospective Studies; Dental Implants; Denture, Complete; Mouth, Edentulous; Patient Reported Outcome Measures
PubMed: 37750530
DOI: 10.1111/clr.14065 -
Medicina (Kaunas, Lithuania) May 2024: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets... (Meta-Analysis)
Meta-Analysis Comparative Study Review
: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets with and without periapical pathology. : After the search and review of the literature in the electronic databases, 109 publications were achieved. The titles and abstracts of 66 publications were screened. After the evaluation of the full text of 22 publications, based on the inclusion criteria, six controlled clinical studies were included in this systematic review and meta-analysis. The statistical calculation showed no heterogeneity among the studies included. The implant survival was 99.6% in the test (socket with periapical pathology) and control (socket without periapical pathology) groups of all the clinical trials. The results of the meta-analysis showed no statistically significant difference between test and control groups regarding the marginal bone level and the width of keratinized mucosa in all the studies. Other parameters indicating plaque level, bleeding on probing, and gingival recession also did not differ between test and control groups at the final follow-up in nearly all studies. : Within the limitation of this systemic review and meta-analysis, the obtained data suggest that implants immediately placed into the extraction sockets of teeth exhibiting periapical pathology can be successfully osseointegrated for an extended period.
Topics: Humans; Tooth Socket; Dental Implantation, Endosseous; Dental Implants; Immediate Dental Implant Loading
PubMed: 38929509
DOI: 10.3390/medicina60060893 -
Dentistry Journal Oct 2023Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose... (Review)
Review
Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose of this study is to systematically review studies (both clinical and in vitro) and determine whether intraoral scanners have clinically acceptable accuracy when recording completely edentulous arches for the fabrication of removable complete dentures. An electronic search in medical databases like PubMed, Scopus, and Web of Science (WOS), using a combination of relevant keywords, retrieved 334 articles. After full-text evaluation, twelve articles fulfilled the inclusion criteria for this review (eight clinical studies and four in vitro studies). A quality analysis of the included studies was carried out using the QUADAS-2 tool. The accuracy values varied between different intraoral scanners. Different regions of the edentulous arches showed differences in trueness and precision values in both in vitro and clinical studies. Peripheral borders, the inner seal, and poorly traceable structures like the soft palate showed maximum discrepancies. The accuracy of intraoral scanners in recording clear anatomic landmarks like hard tissues with attached mucosa was comparable to conventional edentulous arch impressions. However, higher discrepancies were recorded when digitizing mobile and poorly traceable structures. Intraoral scanners can be used to digitize denture-bearing areas, but the interpretation of the peripheral border and the soft palate should be carefully carried out.
PubMed: 37886926
DOI: 10.3390/dj11100241