-
HPB : the Official Journal of the... Dec 2023Post-hepatectomy diaphragmatic hernia is the second most common cause of acquired diaphragmatic hernia. This study aims to review the literature on this complication's... (Review)
Review
BACKGROUND
Post-hepatectomy diaphragmatic hernia is the second most common cause of acquired diaphragmatic hernia. This study aims to review the literature on this complication's incidence, treatment and prognosis.
METHODS
Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we systematically searched PubMed for all studies related to acquired diaphragmatic hernias after hepatectomy.
RESULTS
We included 28 studies in our final analysis, comprising 11,368 hepatectomies. The incidence of post-hepatectomy diaphragmatic hernia was 0.75% (n = 86). The most frequent type of hepatectomy performed was right hepatectomy (79%, n = 68), and the indications for liver resection were a liver donation for living donor transplantation (n = 40), malignant liver tumors (n = 13), and benign tumors (n = 11). The mean onset between liver resection and the diagnosis of diaphragmatic hernia was 25.7 months (range, 1-72 months), and the hernia was located on the right diaphragm in 77 patients (89.5%). Pain was the most common presenting symptom (n = 52, 60.4%), while six patients were asymptomatic (6.9%). Primary repair by direct suture was the most frequently performed technique (88.3%, n = 76). Six patients experienced recurrence (6.9%), and three died before diaphragmatic hernia repair (3.5%).
CONCLUSION
Diaphragmatic hernia is a rare complication occurring mainly after right liver resection. Repair should be performed once detected, given the not-negligible associated mortality in the emergency setting.
Topics: Humans; Hepatectomy; Incidence; Hernia, Diaphragmatic; Diaphragm; Liver Neoplasms
PubMed: 37648598
DOI: 10.1016/j.hpb.2023.08.008 -
Surgical Endoscopy Oct 2023Reinforcement of crural closure with synthetic resorbable mesh has been proposed to decrease recurrence rates after hiatal hernia repair, but continues to be... (Review)
Review
INTRODUCTION
Reinforcement of crural closure with synthetic resorbable mesh has been proposed to decrease recurrence rates after hiatal hernia repair, but continues to be controversial. This systematic review aims to evaluate the safety, efficacy, and intermediate-term results of using biosynthetic mesh to augment the hiatus.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed throughout this systematic review. The Risk of Bias in Non-Randomized Studies of Interventions and Risk of Bias in Randomized Trials tools were used to perform qualitative assessment of all studies included in this review. Recommendations were then summarized for the following pre-defined key items: protocol, research question, search strategy, study eligibility, data extraction, study design, risk of bias, publication bias, and statistical analysis.
RESULTS
The systematic literature search found 520 articles, 101 of which were duplicates and 355 articles were determined to be unrelated to our study and excluded. The full text of the remaining 64 articles was thoroughly assessed. A total of 18 articles (1846 patients) were ultimately included for this review, describing hiatal hernia repair using three different biosynthetic meshes-BIO-A, Phasix ST, and polyglactin mesh. Mean operative time varied from 127 to 223 min. Mean follow up varied from 12 to 54 months. There were no mesh erosions or explants. One mesh-related complication of stenosis requiring reoperation was reported with BIO-A. Studies showed significant improvement in symptom and quality-of-life scores, as well as satisfaction with surgery. Recurrence was reported as radiologic or clinical recurrence. Overall, recurrence rate varied from 0.9 to 25%.
CONCLUSION
The use of biosynthetic mesh is safe and effective for hiatal hernia repair with low complications rates and high symptom resolution. The reported recurrence rates are highly variable due to significant heterogeneity in defining and evaluating recurrences. Further randomized controlled trials with larger samples and long-term follow-up should be performed to better analyze outcomes and recurrence rates.
Topics: Humans; Hernia, Hiatal; Surgical Mesh; Herniorrhaphy; Laparoscopy; Recurrence; Treatment Outcome; Retrospective Studies
PubMed: 37721592
DOI: 10.1007/s00464-023-10379-1 -
World Journal of Clinical Cases Sep 2023Diaphragmatic hernia (DH) is extremely rarely described during pregnancy. Due to the rarity, there is no diagnostic or treatment algorithm for DH in pregnancy.
BACKGROUND
Diaphragmatic hernia (DH) is extremely rarely described during pregnancy. Due to the rarity, there is no diagnostic or treatment algorithm for DH in pregnancy.
AIM
To summarize and define the most appropriate diagnostic methods and therapeutic options for DH in pregnancy based on scarce literature.
METHODS
Literature search of English-, German-, Spanish-, and Italian-language articles were performed using PubMed (1946-2021), PubMed Central (1900-2021), and Google Scholar. The PRISMA protocol was followed. The search terms included: Maternal diaphragmatic hernia, congenital hernia, pregnancy, cardiovascular collapse, mediastinal shift, abdominal pain in pregnancy, hyperemesis, diaphragmatic rupture during labor, puerperium, hernie diaphragmatique maternelle, hernia diafragmática congenital. Additional studies were identified by reviewing reference lists of retrieved studies. Demographic, imaging, surgical, and obstetric data were obtained.
RESULTS
One hundred and fifty-eight cases were collected. The average maternal age increased across observed periods. The proportion of congenital hernias increased, while the other types appeared stationary. Most DHs were left-sided (83.8%). The median number of herniated organs declined across observed periods. A working diagnosis was correct in 50%. DH type did not correlate to maternal or neonatal outcomes. Laparoscopic access increased while thoracotomy varied across periods. Presentation of less than 3 days carried a significant risk of strangulation in pregnancy.
CONCLUSION
The clinical presentation of DH is easily confused with common chest conditions, delaying the diagnosis, and increasing maternal and fetal mortality. Symptomatic DH should be included in the differential diagnosis of pregnant women with abdominal pain associated with dyspnea and chest pain, especially when followed by collapse. Early diagnosis and immediate intervention lead to excellent maternal and fetal outcomes. A proposed algorithm helps manage pregnant women with maternal DH. Strangulated DH requires an emergent operation, while delivery should be based on obstetric indications.
PubMed: 37900237
DOI: 10.12998/wjcc.v11.i27.6440 -
Journal of Robotic Surgery Oct 2023The number of robotic hiatal hernia repairs (RHHR) is increasing. However, the superiority of this minimally invasive approach remains controversial. The aim of this... (Meta-Analysis)
Meta-Analysis Review
The number of robotic hiatal hernia repairs (RHHR) is increasing. However, the superiority of this minimally invasive approach remains controversial. The aim of this study was to evaluate the available literature reporting on outcomes of RHHR compared with laparoscopic hiatal hernia repair (LHHR) in adult patients. The design of this systematic review was developed using the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Web of Science, PubMed, the Cochrane Library, and ClinicalTrials.gov databases were searched. Identified publications were reviewed independently by two authors. High heterogeneity was further explored through sensitivity analysis. The primary endpoint was the development of postoperative complications. Secondary endpoints included operation time, intraoperative complications, 30 day readmission rates and length of stay. The analysis was performed using Stata 17.0 software. A total of 7 studies totaling 10078 patients met the inclusion criteria. Five studies included postoperative complications. The postoperative complications rate was 4.25% (302/7111) in the LHHR group, and 3.49% (38/1088) in the RHHR group. Postoperative complications significantly decreased after RHHR compared with LHHR (OR 0.52; 95% CI 0.36 to 0.75, P = 0.000). Three studies involving 2176 patients reported length of hospital stay. In the three studies, the mean Length of hospital stay was 3.2 days in the RHHR group, and 4.2 days in the LHHR group. Length of hospital stay was decreased by a mean of 0.68 days for RHHR compared with LHHR (WMD, - 0.68 days; 95% CI - 1.32 to - 0.03, P = 0.02). There was no significant difference between the RHHR group and the LHHR group regarding operative time, intraoperative complications, and 30 day readmission (P > 0.05). Our research shows that RHHR may be the better option, as the approach decreases postoperative complications and length of hospital stay.
Topics: Adult; Humans; Herniorrhaphy; Robotic Surgical Procedures; Laparoscopy; Intraoperative Complications; Postoperative Complications; Length of Stay; Hernia, Hiatal
PubMed: 37247119
DOI: 10.1007/s11701-023-01636-5 -
Archives of Disease in Childhood. Fetal... Nov 2023Prognostication of mortality and decision to offer extracorporeal membrane oxygenation (ECMO) treatment in infants with congenital diaphragmatic hernia (CDH) can inform... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Prognostication of mortality and decision to offer extracorporeal membrane oxygenation (ECMO) treatment in infants with congenital diaphragmatic hernia (CDH) can inform clinical management.
OBJECTIVE
To summarise the prognostic value of echocardiography in infants with CDH.
METHODS
Electronic databases Ovid MEDLINE, Embase, Scopus, CINAHL, the Cochrane Library and conference proceedings up to July 2022 were searched. Studies evaluating the prognostic performance of echocardiographic parameters in newborn infants were included. Risk of bias and applicability were assessed using the Quality Assessment of Prognostic Studies tool. We used a random-effect model for meta-analysis to compute mean differences (MDs) for continuous outcomes and relative risk (RR) for binary outcomes with 95% CIs. Our primary outcome was mortality; secondary outcomes were need for ECMO, duration of ventilation, length of stay, and need for oxygen and/or inhaled nitric oxide.
RESULTS
Twenty-six studies were included that were of acceptable methodological quality. Increased diameters of the right and left pulmonary arteries at birth (mm), MD 0.95 (95% CI 0.45 and 1.46) and MD 0.79 (95% CI 0.58 to 0.99), respectively) were associated with survival. Left ventricular (LV) dysfunction, RR 2.40, (95% CI 1.98 to 2.91), right ventricular (RV) dysfunction, RR 1.83 (95% CI 1.29 to 2.60) and severe pulmonary hypertension (PH), RR 1.69, (95% CI 1.53 to 1.86) were associated with mortality. Left and RV dysfunctions, RR 3.30 (95% CI 2.19 to 4.98) and RR 2.16 (95% CI 1.85 to 2.52), respectively, significantly predicted decision to offer ECMO treatment. Limitations are lack of consensus on what parameter is optimal and standardisation of echo assessments.
CONCLUSIONS
LV and RV dysfunctions, PH and pulmonary artery diameter are useful prognostic factors among patients with CDH.
Topics: Infant, Newborn; Infant; Humans; Hernias, Diaphragmatic, Congenital; Prognosis; Echocardiography; Lung; Hypertension, Pulmonary; Retrospective Studies
PubMed: 37130729
DOI: 10.1136/archdischild-2022-325257 -
Scientific Reports Sep 2023Outcomes of conventional mechanical ventilation (CMV) and high-frequency oscillatory ventilation (HFOV) in patients with congenital diaphragmatic hernia (CDH) were... (Meta-Analysis)
Meta-Analysis
Outcomes of conventional mechanical ventilation (CMV) and high-frequency oscillatory ventilation (HFOV) in patients with congenital diaphragmatic hernia (CDH) were compared through a systematic review and meta-analysis. Outcome measures included mortality and incidence of chronic lung disease (CLD). Odds ratio (OR) and 95% confidence interval (95%CI) were evaluated. Subgroup analyses were performed according to the strategy for applying HFOV in CDH patients. Group A: CMV was initially applied in all CDH patients, and HFOV was applied in unstable patients. Group B: chronologically analyzed. (CMV and HFOV era) Group C: CMV or HFOV was used as the initial MV. Of the 2199 abstracts screened, 15 full-text articles were analyzed. Regarding mortality, 16.7% (365/2180) and 32.8% (456/1389) patients died in CMV and HFOV, respectively (OR, 2.53; 95%CI 2.12-3.01). Subgroup analyses showed significantly worse, better, and equivalent mortality for HFOV than that for CMV in group A, B, and C, respectively. CLD occurred in 32.4% (399/1230) and 49.3% (369/749) patients in CMV and HFOV, respectively (OR, 2.37; 95%CI 1.93-2.90). The evidence from the literature is poor. Mortality and the incidence of CLD appear worse after HFOV in children with CDH. Cautious interpretation is needed due to the heterogeneity of each study.
Topics: Child; Humans; Respiration, Artificial; Hernias, Diaphragmatic, Congenital; High-Frequency Ventilation; Death; Cytomegalovirus Infections
PubMed: 37752154
DOI: 10.1038/s41598-023-42344-2 -
Diseases of the Esophagus : Official... Jul 2023Laparoscopic hiatal hernia repair (HHR) and fundoplication is a common low risk procedure providing excellent control of gastro-oesophageal reflux disease and restoring... (Meta-Analysis)
Meta-Analysis
What works best in hiatus hernia repair, sutures alone, absorbable mesh or non-absorbable mesh? A systematic review and network meta-analysis of randomized clinical trials.
Laparoscopic hiatal hernia repair (HHR) and fundoplication is a common low risk procedure providing excellent control of gastro-oesophageal reflux disease and restoring of normal anatomy at the hiatus. HHR may fail, however, resulting in hiatus hernia (HH) recurrence, and the use of tension-free mesh-augmented hernioplasty has been proposed to reduce recurrence. Previous research on this topic has been heterogeneous, including study methods, mesh type used and technique performed. A systematic review and network meta-analysis were carried out. An electronic systematic research was carried out using 'PUBMED', 'EMBASE', 'Medline (OVID)' and 'Web of Science', of articles identifying HHR with suture cruroplasty, non-absorbable mesh (NAM) and absorbable mesh (AM) reinforcement. Eight RCTs with 766 patients were evaluated. NAM had significantly (P < 0.05) lower early recurrence rates (OR: 0.225, 95% CI 0.0342, 0.871) compared with suture repair alone; however, no differences in late recurrences were evident. For AM, no difference in early (0.508, 95% CI 0.0605, 4.81) or late (1.07. 95% CI 0.116, 11.4) recurrence rates were evident compared with the suture only group. Major complication rates were similar in all groups. NAM reinforcement significantly reduced early HH recurrence when compared with sutured cruroplasty alone; however, late recurrence rates were similar with all techniques. Given the limited data in comparing AM with NAM, this study was unable to conclude which composition was significant. We emphasize caution when interpreting small sample size RCTs, and recommend more research with larger randomized studies.
Topics: Humans; Herniorrhaphy; Treatment Outcome; Surgical Mesh; Network Meta-Analysis; Laparoscopy; Randomized Controlled Trials as Topic; Hernia, Hiatal; Sutures; Recurrence
PubMed: 36563005
DOI: 10.1093/dote/doac101 -
Prenatal Diagnosis Jul 2023This systematic review and meta-analysis aimed to review the optimal timing of delivery at term for neonates with prenatally diagnosed congenital diaphragmatic hernia... (Meta-Analysis)
Meta-Analysis Review
This systematic review and meta-analysis aimed to review the optimal timing of delivery at term for neonates with prenatally diagnosed congenital diaphragmatic hernia (CDH). We reviewed the literature up to December 19, 2022 using MEDLINE and the Cochrane Library databases. The inclusion criteria were original articles, comparative studies of CDH neonates delivered at an early term (37-38 weeks of gestation) and at full term (39 weeks of gestation or later), and comparative studies investigating outcomes of CDH neonates. Six studies met the inclusion criteria, including 985 neonates delivered at an early term and 629 delivered at full term. The cumulative rate of survival to discharge showed no significant difference between CDH neonates delivered at an early term (395/515; 76.7%) or at full term (345/467; 73.9%) (risk ratio [RR] 1.01; 95% confidence interval [CI], 0.89-1.16; p = 0.85). Furthermore, the number of neonates requiring oxygen therapy at discharge was not significantly different between CDH neonates delivered at an early term (32/370; 8.6%) and at full term (14/154; 9.1%) (RR, 0.99; 95% CI, 0.36-2.70; p = 0.99). Therefore, the optimal timing of delivery at term for neonates with CDH remains unclear.
Topics: Humans; Infant, Newborn; Databases, Factual; Hernias, Diaphragmatic, Congenital; Odds Ratio; Retrospective Studies; Delivery, Obstetric; Female; Pregnancy
PubMed: 37127552
DOI: 10.1002/pd.6365 -
Journal of Clinical Medicine Jun 2024We aimed to conduct a systematic review and meta-analysis to evaluate the fetoscopic tracheal occlusion in patients with isolated severe and left-sided diaphragmatic... (Review)
Review
We aimed to conduct a systematic review and meta-analysis to evaluate the fetoscopic tracheal occlusion in patients with isolated severe and left-sided diaphragmatic hernia. Cochrane Library, Embase, and PubMed (Medline) databases were searched from inception to February 2024 with no filters or language restrictions. We included studies evaluating the outcomes of fetoscopic intervention compared to expectant management among patients with severe congenital diaphragmatic hernia exclusively on the left side. A random-effects pairwise meta-analysis was performed using RStudio version 4.3.1. In this study, we included 540 patients from three randomized trials and five cohorts. We found an increased likelihood of neonatal survival associated with fetoscopic tracheal occlusion (Odds Ratio, 5.07; 95% Confidence Intervals, 1.91 to 13.44; < 0.01) across general and subgroup analyses. Nevertheless, there were higher rates of preterm birth (OR, 5.62; 95% CI, 3.47-9.11; < 0.01) and preterm premature rupture of membranes (OR, 7.13; 95% CI, 3.76-13.54; < 0.01) in fetal endoscopic tracheal occlusion group compared to the expectant management. Our systematic review and meta-analysis demonstrated the benefit of fetoscopic tracheal occlusion in improving neonatal and six-month postnatal survival in fetuses with severe left-sided CDH. Further studies are still necessary to evaluate the efficacy of tracheal occlusion for isolated right-sided CDH, as well as the optimal timing to perform the intervention.
PubMed: 38930102
DOI: 10.3390/jcm13123572 -
Annals of Surgery Mar 2024This systematic review aims to evaluate current choice in practice and outcomes of biomaterials used in patch repair of congenital diaphragmatic hernia (CDH).
OBJECTIVE
This systematic review aims to evaluate current choice in practice and outcomes of biomaterials used in patch repair of congenital diaphragmatic hernia (CDH).
BACKGROUND
Multiple biomaterials, both novel and combinations of pre-existing materials are employed in patch repair of large size CDH.
METHODS
Literature search was performed across Embase, Medline, Scopus, and Web of Science. Publications that explicitly reported patch repair, material used and recurrences following CDH repair were selected.
RESULTS
Sixty-three papers were included, presenting data on 4598 patients of which 1811 (39.4%) were managed using 19 types of patches. Goretex® (GTX) (n=1259) was the most frequently employed patch followed by Surgisis® (n=164), Dualmesh® (n=114), Marlex®/GTX® (n=56), Tutoplast dura® (n=40), Dacron® (n=34), Dacron®/GTX® (n=32), Permacol® (n=24), Teflon® (n=24), Surgisis®/GTX® (n=15), Sauvage® Filamentous Fabric (n=13), Marlex® (n=9), Alloderm® (n=8), Silastic® (n=4), Collagen coated Vicryl® mesh (CCVM) (n=1), Mersilene® (n=1), and MatriStem® (n=1) Biomaterials were further subgrouped as: Synthetic non-resorbable (SNOR) (n=1458), Natural-resorbable (NR) (n=249), Combined natural and synthetic non-resorbable (NSNOR) (n=103), and Combined natural and synthetic resorbable (NSR) (n=1). Overall recurrence rate for patch repair was 16.8% (n=305). For patch types with n>20, recurrence rate was lowest in GTX/Marlex (3.6%), followed by Teflon (4.2%), Dacron (5.6%), GTX (13.8%), Permacol (16.0%), Tutoplast Dura (17.5%), Dualmesh (20.2%), SIS/GTX (26.7%), SIS (36.6%), and Dacron/GTX (37.5%).When analysed by biomaterial groups, recurrence was highest in NSR (100%), followed by NR (32.9%), NSNOR (17.5) and SNOR the least (14.0%).
CONCLUSION
In this cohort, over one-third of CDH were closed using patches. To date, 19 patch types/variations have been employed for CDH closure. GTX is the most popular, employed in 70% of patients; however excluding smaller cohorts (n<20) GTX/Marlex is associated with the lowest recurrence rate (3.6%). SNOR was the material type least associated with recurrence while NSR experienced recurrence in every instance.
PubMed: 38450531
DOI: 10.1097/SLA.0000000000006256