Arthroscopy : the Journal of... Apr 2024To analyze radiographic outcomes by conventional radiography, computed tomography (CT), or both and complication rates of open coracoid transfer at a minimum of... (Review)
Review
Postoperative Radiographic Outcomes Following Primary Open Coracoid Transfer (Bristow-Latarjet) Vary in Definition, Classification, and Imaging Modality: A Systematic Review.
PURPOSE
To analyze radiographic outcomes by conventional radiography, computed tomography (CT), or both and complication rates of open coracoid transfer at a minimum of 12-months follow-up.
METHODS
A literature search was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, using PubMed, Medline (Ovid), and EMBASE library databases. Inclusion criteria were clinical studies reporting on open Latarjet as the primary surgical procedure(revision coracoid transfer after failed prior stabilization excluded) with postoperative radiographic outcomes at a minimum mean 1-year follow-up. Patient demographics, type of postoperative imaging modality, and radiographic outcomes and complications including graft union, osteoarthritis, and osteolysis were systematically reviewed. Data were summarized as ranges of reported values for each outcome metric. Each radiographic outcome was graphically represented in a Forest plot with point estimates of the incidence of radiographic outcomes with corresponding 95% confidence intervals and I.
RESULTS
Thirty-three studies met inclusion criteria, with a total of 1,456 shoulders. The most common postoperative imaging modality was plain radiography only (n = 848 [58.2%]), both CT and radiography (n = 287 [19.7%]), and CT only (n = 321 [22.1%]). Overall, the reported graft union rate ranged from 75% to 100%, of which 79.8% (n = 395) were detected on plain radiography. The most common reported postoperative radiographic complications after the open coracoid transfer were osteoarthritis (range, 0%-100%, pooled mean 28%), graft osteolysis (range, 0%-100%, pooled mean 30%), nonunion (range, 0%-32%, pooled mean 5.1%), malpositioned graft (range, 0%-75%, pooled mean 14.75%), hardware issues (range, 0%-9.1%, pooled mean 5%), and bone block fracture (range, 0%-8%, pooled mean 2.1%). Graft healing was achieved in a majority of cases (range, 75%-100%).
CONCLUSION
Postoperative radiographic outcomes after open coracoid transfer vary greatly in definition, classification, and imaging modality of choice. Greater consistency in postoperative radiographic outcomes is essential to evaluate graft healing, osteolysis, and nonunion.
LEVEL OF EVIDENCE
Level IV, systematic review of Level III-IV studies.
Topics: Humans; Shoulder Joint; Osteolysis; Joint Instability; Shoulder; Shoulder Dislocation; Osteoarthritis; Fractures, Bone; Coracoid Process
PubMed: 37827435
DOI: 10.1016/j.arthro.2023.09.032 -
PloS One 2024Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as...
A scoping review on the clinical effectiveness of Trans-Impedance Matrix (TIM) measurements in detecting extracochlear electrodes and tip fold overs in Cochlear Ltd devices.
BACKGROUND
Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as Trans-Impedance Matrix (TIM) measurements may enable clinicians to identify electrode malposition and direct surgeons to correctly place the electrode array during surgery.
OBJECTIVES
To assess the current literature on the effectiveness of TIM measurements in identifying extracochlear electrodes and tip fold overs.
METHODS
A scoping review of studies on TIM-based measurements were carried out using the Databases-Medline/PubMed, AMED, EMBASE, CINAHL and the Cochrane Library following PRISMA guidelines. Eleven full texts articles met the inclusion criteria. Only human studies pertaining to TIM as a tool used in CI were included in the review. Further, patient characteristics, electrode design, and TIM measurement outcomes were reported.
RESULTS
TIM measurements were available for 550 implanted ears with the subjects age ranged between 9 months to 89 years. Abnormal TIM measurements were reported for 6.55% (36). Tip fold over was detected in 3.64% (20) of the cases, extracochlear electrodes in 1.45% (8), and 1.45% (8) were reported as buckling. Slim-modiolar electrode array designs were more common (54.71%) than pre-curved (23.34%) or lateral wall (21.95%) electrode array. Abnormal cochlear anatomy was reported for five ears (0.89%), with normal cochlear anatomy for all other patients.
CONCLUSION
TIM measurement is a promising tool for the intraoperative detection of electrode malposition. TIM measurement has a potential to replace intraoperative imaging in future. Though, TIM measurement is in its early stages of clinical utility, intuitive normative data sets coupled with standardised criteria for detection of abnormal electrode positioning would enhance its sensitivity.
Topics: Humans; Cochlea; Cochlear Implantation; Cochlear Implants; Electric Impedance; Electrodes, Implanted; Treatment Outcome
PubMed: 38452034
DOI: 10.1371/journal.pone.0299597