Chest Aug 2023Respiratory failure is a significant concern in neuromuscular diseases (NMDs). This CHEST guideline examines the literature on the respiratory management of patients...
BACKGROUND
Respiratory failure is a significant concern in neuromuscular diseases (NMDs). This CHEST guideline examines the literature on the respiratory management of patients with NMD to provide evidence-based recommendations.
STUDY DESIGN AND METHODS
An expert panel conducted a systematic review addressing the respiratory management of NMD and applied the Grading of Recommendations, Assessment, Development, and Evaluations approach for assessing the certainty of the evidence and formulating and grading recommendations. A modified Delphi technique was used to reach a consensus on the recommendations.
RESULTS
Based on 128 studies, the panel generated 15 graded recommendations, one good practice statement, and one consensus-based statement.
INTERPRETATION
Evidence of best practices for respiratory management in NMD is limited and is based primarily on observational data in amyotrophic lateral sclerosis. The panel found that pulmonary function testing every 6 months may be beneficial and may be used to initiate noninvasive ventilation (NIV) when clinically indicated. An individualized approach to NIV settings may benefit patients with chronic respiratory failure and sleep-disordered breathing related to NMD. When resources allow, polysomnography or overnight oximetry can help to guide the initiation of NIV. The panel provided guidelines for mouthpiece ventilation, transition to home mechanical ventilation, salivary secretion management, and airway clearance therapies. The guideline panel emphasizes that NMD pathologic characteristics represent a diverse group of disorders with differing rates of decline in lung function. The clinician's role is to add evaluation at the bedside to shared decision-making with patients and families, including respect for patient preferences and treatment goals, considerations of quality of life, and appropriate use of available resources in decision-making.
Topics: Humans; Quality of Life; Respiration, Artificial; Noninvasive Ventilation; Respiratory Insufficiency; Physicians
PubMed: 36921894
DOI: 10.1016/j.chest.2023.03.011 -
American Journal of Perinatology Nov 2023Congenital heart defects (CHDs) are the most common neonatal malformations and are a leading cause of infant death in developed countries. Finding safe and effective... (Meta-Analysis)
Meta-Analysis
Congenital heart defects (CHDs) are the most common neonatal malformations and are a leading cause of infant death in developed countries. Finding safe and effective diagnostic methods to screen for CHDs is important. The aim of this study was to evaluate the effectiveness of pulse oximetry (PO) and perfusion index (PI) in screening CHD. We conducted a systematic review of studies in PubMed, Embase, and the Cochrane Library published on or before October 1, 2021. Studies based on PICOS were included in this systematic review. The flow chart is made by PRISMA software. The quality of included studies was assessed by RevMan5 software (QUADAS-2: Quality Assessment of Diagnostic Accuracy Studies-2). The sensitivity, specificity, and other measurements of accuracy were pooled using Stata/SE 12.0 software. Five studies containing 46,965 neonates were included in this study. A randomized-effects model was used for the meta-analysis because of significant heterogeneity. The combined sensitivity and specificity were 0.82 (95% confidence interval [CI], 0.53-0.95) and 0.97 (95% CI, 0.57-1.00), respectively. The area under the curve was 0.92 (95% CI, 0.89-0.94). The combination PO and PI was significant in CHD screening. Once diagnosed by the combined method, it means that the neonate is most likely to have a CHD. KEY POINTS: · Pulse oximetry and PI screening.. · Congenital heart defects.. · A systematic review and meta-analysis..
Topics: Infant, Newborn; Infant; Humans; Perfusion Index; Neonatal Screening; Oximetry; Sensitivity and Specificity; Heart Defects, Congenital
PubMed: 35580627
DOI: 10.1055/s-0042-1748163 -
Annals of Plastic Surgery Nov 2023Tissue oximetry monitoring has shown superior outcomes to conventional monitoring methods for autologous breast reconstruction in retrospective studies with consecutive... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Tissue oximetry monitoring has shown superior outcomes to conventional monitoring methods for autologous breast reconstruction in retrospective studies with consecutive cohorts. A recent study used consecutive cohorts with tissue oximetry as the earlier cohort and found that tissue oximetry was nonsuperior. We hypothesize that improvement in microsurgical outcomes with institutional experience confounds the superiority of tissue oximetry demonstrated in prior studies. This study aimed to perform a systematic review and meta-analysis of the outcomes of tissue oximetry monitoring compared with conventional monitoring.
METHODS
Relevant studies were found using PubMed, Embase, and Web of Science searches for keywords such as near-infrared spectroscopy or tissue oximetry and microsurgery. Studies included compared tissue oximetry and conventional monitoring in autologous breast reconstruction patients. Studies were excluded if they did not contain a comparison group. Random-effective models were used to analyze early returns to the operating room, the total number of partial or complete flap loss, and late fat necrosis.
RESULTS
Six hundred sixty-nine studies were identified; 3 retrospective cohort studies met the inclusion criteria. A total of 1644 flaps were in the tissue oximetry cohort, and 1387 flaps were in the control cohort. One study contained tissue oximetry as the former cohort; 2 had tissue oximetry as the latter. Neither technique was superior for any measured outcomes. The estimated mean differences between tissue oximetry and conventional monitoring method were early returns, -0.06 (95% confidence interval [CI], -0.52 to 0.410; P = 0.82); partial flap loss, -0.04 (95% CI, -0.86 to 0.79; P = 0.93); complete flap loss, -1.29 (95% CI, -3.45 to 0.87; P = 0.24); and late fat necrosis -0.02 (95% CI, -0.42 to, 0.39; P = 0.94).
CONCLUSIONS
In a systematic review and meta-analysis of mixed timeline retrospective cohort studies, tissue oximetry does not provide superior patient outcomes and shifts our current understanding of postoperative breast reconstruction monitoring. Prospective studies and randomized trials comparing monitoring methods need to be included in the existing literature.
Topics: Humans; Retrospective Studies; Prospective Studies; Fat Necrosis; Mammaplasty; Postoperative Complications; Oximetry
PubMed: 37823627
DOI: 10.1097/SAP.0000000000003705 -
The Journal of Cardiovascular Nursing Sep 2023Lower limb peripheral artery disease (PAD) is associated with poor outcomes including ulceration, gangrene, amputations, and mortality. Clinicians therefore routinely...
BACKGROUND
Lower limb peripheral artery disease (PAD) is associated with poor outcomes including ulceration, gangrene, amputations, and mortality. Clinicians therefore routinely perform point-of-care tests in high-risk populations to identify PAD and subsequently implement cardiovascular management and appropriate interventions. Pulse oximetry has been suggested as a useful adjunct test for identifying PAD.
OBJECTIVE
The aim of this systematic review was to determine the sensitivity and specificity of pulse oximetry in the lower limb for identifying PAD.
METHODS
MEDLINE, EMBASE, and CINAHL were searched up until January 10, 2023, to identify studies of sensitivity and specificity of pulse oximetry that used criterion standard diagnostic imaging as a reference standard. Two authors screened articles for inclusion and appraised quality of included studies using the Quality Appraisal for Diagnostic Accuracy Studies, version 2.
RESULTS
A total of 6371 records were screened, and 4 were included. The included studies had a total of 471 participants, with an age range of 41 to 80.6 years. All studies were cross-sectional and conducted in hospital settings. Sensitivity values for pulse oximetry compared with diagnostic imaging in identifying PAD ranged from 44% to 76%, and specificity values ranged from 85% to 96%. There was no consensus regarding measurement techniques and diagnostic thresholds for pulse oximetry, which precluded meta-analysis.
CONCLUSIONS
There is currently inadequate evidence to support the use of pulse oximetry for identifying PAD. Current evidence suggests that pulse oximetry has low levels of sensitivity and is therefore likely to miss PAD when it is present.
PubMed: 37787731
DOI: 10.1097/JCN.0000000000001030 -
Journal of Clinical Anesthesia Jun 2024The current standards of postoperative respiratory monitoring on medical-surgical floors involve spot-pulse oximetry checks every 4-8 h, which can miss the opportunity... (Meta-Analysis)
Meta-Analysis Review
Role of continuous pulse oximetry and capnography monitoring in the prevention of postoperative respiratory failure, postoperative opioid-induced respiratory depression and adverse outcomes on hospital wards: A systematic review and meta-analysis.
OBJECTIVE
The current standards of postoperative respiratory monitoring on medical-surgical floors involve spot-pulse oximetry checks every 4-8 h, which can miss the opportunity to detect prolonged hypoxia and acute hypercapnia. Continuous respiratory monitoring can recognize acute respiratory depression episodes; however, the existing evidence is limited. We sought to review the current evidence on the effectiveness of continuous pulse oximetry (CPOX) with and without capnography versus routine monitoring and their effectiveness for detecting postoperative respiratory failure, opioid-induced respiratory depression, and preventing downstream adverse events.
METHODS
We performed a systematic literature search on Ovid Medline, Embase, and Cochrane Library databases for articles published between 1990 and April 2023. The study protocol was registered in Prospero (ID: 439467), and PRISMA guidelines were followed. The NIH quality assessment tool was used to assess the quality of the studies. Pooled analysis was conducted using the software R version 4.1.1 and the package meta. The stability of the results was assessed using sensitivity analysis.
DESIGN
Systematic Review and Meta-Analysis.
SETTING
Postoperative recovery area.
PATIENTS
56,538 patients, ASA class II to IV, non-invasive respiratory monitoring, and post-operative respiratory depression.
INTERVENTIONS
Continuous pulse oximetry with or without capnography versus routine monitoring.
MEASUREMENTS
Respiratory rate, oxygen saturation, adverse events, and rescue events.
RESULTS
23 studies (17 examined CPOX without capnography and 5 examined CPOX with capnography) were included in this systematic review. CPOX was better at recognizing desaturation (SpO < 90%) OR: 11.94 (95% CI: 6.85, 20.82; p < 0.01) compared to standard monitoring. No significant differences were reported for ICU transfer, reintubation, and non-invasive ventilation between the two groups.
CONCLUSIONS
Oxygen desaturation was the only outcome better detected with CPOX in postoperative patients in hospital wards. These comparisons were limited by the small number of studies that could be pooled for each outcome and the heterogeneity between the studies.
Topics: Humans; Analgesics, Opioid; Respiratory Rate; Capnography; Monitoring, Physiologic; Respiratory Insufficiency; Oximetry; Postoperative Complications; Hospitals
PubMed: 38184918
DOI: 10.1016/j.jclinane.2024.111374 -
International Wound Journal Dec 2023Ankle Brachial Pressure Index (ABPI) measurement has long been considered the gold standard of vascular assessment for people with lower limb ulceration. Despite this,... (Review)
Review
Ankle Brachial Pressure Index (ABPI) measurement has long been considered the gold standard of vascular assessment for people with lower limb ulceration. Despite this, only around 15% of patients in the United Kingdom who require an ABPI measurement undergo the assessment. The Lanarkshire Oximetry Index (LOI) is a cheaper and arguably more accessible approach to vascular assessment and was initially proposed as an alternative to the ABPI in 2000. No synthesis of evidence related to the LOI has been performed since its introduction into the literature. Primary studies were sought to determine the clinimetric properties of the LOI and its level of agreement with ABPI assessments. Systematic searches of MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials, BNI, ProQuest Health and Medicine, Science Direct, Google Scholar and the British Library (online search) were conducted. Reference lists of identified studies were also reviewed to identify additional studies. Three primary studies met the inclusion criteria, reporting data from 307 patients and 584 limbs assessed using both the LOI and ABPI. All three studies reported fair to moderate kappa values for interrater reliability (κ = 0.290-0.747) and statistically significant positive correlation coefficients (r = 0.37, p < 0.001 in two studies) between the LOI and ABPI. The combined data from the three studies indicated a sensitivity of 52% (41.78-62.1, 95% confidence interval [CI]) and specificity of 96.08% (93.4-97.9, 95% CI) for the LOI using the ABPI as a reference. Additional data are required to indicate the safety of the LOI in practice. Data are also required to determine if the LOI is more acceptable to clinicians compared to the ABPI and whether there are any barriers/enablers to its implementation in practice. Given the relatively low specificity of the LOI, it may be beneficial to combine measurement of the LOI with a subjective clinical risk assessment tool to improve the sensitivity of this alternative approach to vascular assessment.
PubMed: 38050665
DOI: 10.1111/iwj.14519 -
Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668 -
Archives of Disease in Childhood. Fetal... Dec 2023Measuring exhaled carbon dioxide (ECO) during non-invasive ventilation at birth may provide information about lung aeration. However, the International Liaison Committee...
OBJECTIVE
Measuring exhaled carbon dioxide (ECO) during non-invasive ventilation at birth may provide information about lung aeration. However, the International Liaison Committee on Resuscitation (ILCOR) only recommends ECO detection for confirming endotracheal tube placement. ILCOR has therefore prioritised a research question that needs to be urgently evaluated: 'In newborn infants receiving intermittent positive pressure ventilation by any non-invasive interface at birth, does the use of an ECO monitor in addition to clinical assessment, pulse oximetry and/or ECG, compared with clinical assessment, pulse oximetry and/or ECG only, decrease endotracheal intubation in the delivery room, improve response to resuscitation, improve survival or reduce morbidity?'.
DESIGN
Systematic review of randomised and non-randomised studies identified by Ovid MEDLINE, Embase and Cochrane CENTRAL search until 1 August 2022.
SETTING
Delivery room.
PATIENTS
Newborn infants receiving non-invasive ventilation at birth.
INTERVENTION
ECO measurement plus routine assessment compared with routine assessment alone.
MAIN OUTCOME MEASURES
Endotracheal intubation in the delivery room, response to resuscitation, survival and morbidity.
RESULTS
Among 2370 articles, 23 were included; however, none had a relevant control group. Although studies indicated that the absence of ECO may signify airway obstruction and ECO detection may precede a heart rate increase in adequately ventilated infants, they did not directly address the research question.
CONCLUSIONS
Evidence to support the use of an ECO monitor to guide non-invasive positive pressure ventilation at birth is lacking. More research on the effectiveness of ECO measurement in addition to routine assessment during non-invasive ventilation of newborn infants at birth is needed.
PROSPERO REGISTRATION NUMBER
CRD42022344849.
Topics: Infant, Newborn; Infant; Humans; Noninvasive Ventilation; Carbon Dioxide; Respiration, Artificial; Positive-Pressure Respiration; Resuscitation; Intermittent Positive-Pressure Ventilation
PubMed: 37558397
DOI: 10.1136/archdischild-2023-325698 -
Journal of Plastic, Reconstructive &... Dec 2023Patent microvascular anastomoses are essential for successful free tissue transfer. Early accurate detection of microvascular compromise is required for flap salvage....
Patent microvascular anastomoses are essential for successful free tissue transfer. Early accurate detection of microvascular compromise is required for flap salvage. Adjunctive monitoring techniques, in addition to clinical examination, are increasingly used to detect flap compromise. This systematic review synthesized and appraised the literature to determine the efficacy of different postoperative monitoring technologies. Rates of flap takeback, salvage, failure, and mean time to detection of microvascular compromise were extracted, synthesized, and reviewed. Twenty-two studies were included, comprising 6370 flaps. One thousand three hundred and ninety-five flaps were monitored with Cook Swartz Doppler (21.83%), 1417 flaps with tissue oximetry (22.24%), 291 with laser Doppler (4.56%), 175 with duplex echography (2.74%), 210 with indocyanine green (ICG) fluorescence (3.30%), 196 with Synovis flow coupler (3.07%), and 81 (1.27%) with light spectroscopy. The overall true positive rate for microvascular compromise in taken back flaps was 70.18%. Cook Swartz Doppler (n = 1391) had a true positive rate of 80.17% and 83.63% salvage rate and was associated with an overall 2.60% rate of flap failure. Tissue oximetry (n = 1417) had a true positive rate of 74.76% and a salvage rate of 88.62%. Laser Doppler, duplex echography, light spectroscopy, and Synovis flow coupler demonstrated true positive rates between 69.4% and 100% with salvage rates between 64% and 100%. Cook Swartz Doppler and tissue oximetry are associated with prompt identification of microvascular compromise and return to theatre. Alternative modalities, including near-infrared spectroscopy, laser Doppler, and duplex echography, show promise. Further well-designed randomised controlled trials (RCTs) appraising head-to-head efficacy are required to comparatively assess adjunctive technologies.
Topics: Humans; Free Tissue Flaps; Monitoring, Physiologic; Ultrasonography, Doppler; Physical Examination; Ultrasonography, Doppler, Duplex; Postoperative Complications; Retrospective Studies
PubMed: 37844383
DOI: 10.1016/j.bjps.2023.09.015 -
Respiratory Care Sep 2023The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S... (Review)
Review
BACKGROUND
The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S measurement.
METHODS
We queried PubMed, Embase, and CINAHL databases for publications indexed through December 2022. We included studies providing paired S data from fingertips without and after nail polish application or reporting the number of subjects whose S could not be measured due to fingernail polish. We used random effects modeling to summarize standardized mean differences (SMDs) and corresponding 95% CI for different nail polish colors from comparative studies.
RESULTS
We retrieved 122 studies and included 21 publications, mostly performed on healthy volunteers. Of these, 17 (81.0%) studies had a low risk of bias. We summarized mean SMD for 10 nail polish colors (black, blue, brown, green, orange, pink, purple, red, white, and yellow) from 25 paired data sets on S across 20 studies. We found small (likely clinically insignificant) but statistically significant differences in mean S when fingers were coated with black, blue, brown, or purple nail polish (SMD -0.57, -0.47, -0.33, and -0.25, respectively; 95% CI -0.86 to -0.29, -0.84 to -0.10, -0.59 to -0.07, and -0.48 to -0.02, respectively). Only one of 4 studies reported a high proportion of unsuccessful oximeter readings from fingers painted with black (88.0%) or brown (36.0%) nail polish.
CONCLUSIONS
Although fingernail polish of some colors can marginally reduce S reading or occasionally impede S measurement, the variability is clinically insignificant.
Topics: Humans; Color; Cosmetics; Nails; Oximetry; Oxygen
PubMed: 37185113
DOI: 10.4187/respcare.10399