Endocrine Aug 2023To summarize the more robust evidence about the performance of tools useful for diagnosis of medullary thyroid carcinoma (MTC) such as calcitonin (Ctn) and other... (Review)
Review
PURPOSE
To summarize the more robust evidence about the performance of tools useful for diagnosis of medullary thyroid carcinoma (MTC) such as calcitonin (Ctn) and other circulating markers, ultrasound (US), fine-needle aspiration (FNA), and other imaging procedures.
METHODS
This systematic review of systematic reviews was carried out according to a predefined protocol. A search string was created. An electronical comprehensive search of literature was performed on December 2022. Quality assessment of eligible systematic reviews was performed and main findings were described.
RESULTS
Twenty-three systematic reviews were included and several findings were achieved. Ctn is the most reliable diagnostic marker of MTC with no evidence of improvement with stimulation test. CEA doubling time is more reliable than Ctn in identifying MTC with poorer prognosis. US sensitivity is suboptimal in MTC and only just over half of cases are at high risk according to Thyroid Imaging And Reporting Data Systems. Cytology can correctly detect MTC in just over half of cases and measuring Ctn in washout fluid from FNA is necessary. PET/CT is useful for detecting recurrent MTC.
CONCLUSIONS
Future guidelines of both thyroid nodule management and MTC diagnosis should consider these evidence-based data.
Topics: Thyroid Neoplasms; Thyroid Nodule; Positron Emission Tomography Computed Tomography; Diagnostic Tests, Routine; Calcitonin; Systematic Reviews as Topic; Biopsy, Fine-Needle
PubMed: 36877452
DOI: 10.1007/s12020-023-03326-6 -
Respiratory Medicine Nov 2023New tools such as cryobiopsy of mediastinal lymph nodes (cryoEBUS) have been described to improve the diagnostic usefulness of endobronchial ultrasound-guided... (Meta-Analysis)
Meta-Analysis Review
Is the diagnostic yield of mediastinal lymph node cryobiopsy (cryoEBUS) better for diagnosing mediastinal node involvement compared to endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA)? A systematic review.
INTRODUCTION
New tools such as cryobiopsy of mediastinal lymph nodes (cryoEBUS) have been described to improve the diagnostic usefulness of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The literature suggests that this novel procedure could be associated with greater diagnostic usefulness than conventional EBUS-TBNA.
METHODS
To develop a systematic analysis and meta-analysis on the diagnostic diagnostic yield and safety of cryobiopsy of hilar and mediastinal adenopathies compared to EBUS-TBNA.
RESULTS
Seven studies that had included a total of 555 patients were considered in this review, with 365 (65.7%) of these patients having an etiology of malignant lymph node involvement. The overall diagnostic usefulness of cryoEBUS was higher compared to EBUS-TBNA (92% vs. 80%). However, when the results were analysed according to the specific aetiologies of the adenopathies, cryoEBUS was especially useful in cases of lymphomas or non-pulmonary carcinomas (83% vs. 42%) and in cases that were benign (87% vs. 60.1%), with no significant differences being found in specific cases of lung cancer. For lymphoma, cryoEBUS was diagnostic in 87% of cases compared to 12% for EBUS-TBNA and in addition, also allowed the characterisation of every lymphoma subtype. Genetic studies and immunohistochemical determination of PD-L1 was possible in almost all (97%) of the samples obtained by cryoEBUS, while this was only possible in 79% of those obtained by EBUS-TBNA. The most frequent complication was light bleeding, which was described in up to 85% of cases in some series.
CONCLUSION
CryoEBUS could represent a promising technique in the diagnostic algorithm used for mediastinal and hilar involvement. Although cryoEBUS did not significantly improve the diagnosis of lung cancer compared to EBUS-TBNA, the results were significantly better in patients with benign pathologies and other tumour types, including lymphomas. In addition, it seems that the samples obtained by cryoEBUS better defined the histological subtypes of lymphoma and allowed complete molecular characterisation in cases of lung cancer. The technique has proven to be safe and no serious complications were described after the procedure.
Topics: Humans; Bronchoscopy; Mediastinum; Lymph Nodes; Lung Neoplasms; Endoscopic Ultrasound-Guided Fine Needle Aspiration; Lymphadenopathy; Lymphoma; Retrospective Studies
PubMed: 37579981
DOI: 10.1016/j.rmed.2023.107389 -
Medical Ultrasonography May 2024To evaluate the contrast-enhanced ultrasound (CEUS) versus conventional ultrasound (US) in guided liver puncture biopsy through a systematic review and meta-analysis. (Review)
Review
AIM
To evaluate the contrast-enhanced ultrasound (CEUS) versus conventional ultrasound (US) in guided liver puncture biopsy through a systematic review and meta-analysis.
MATERIAL AND METHODS
Comparative studies on CEUS and US in liver puncture biopsy were systematically searched from PubMed, Embase, Cochrane library, Chinese Biomedical Literature Database. Two researchers independently screened and extracted data, and RevMan 5.3 software was used for data analysis.
RESULTS
The area under the curve (AUC) for CEUS and US in diagnosing liver biopsy was 0.98 (95%CI 0.99-0.97) and 0.95 (95%CI 0.97-0.93), respectively. CEUS demonstrated significantly higher single puncture success rate (38.0% vs 36.4%) [OR=2.67; 95% CI 1.38-5 .17; p=0 .003] and pathological diagnosis rate (95.6% vs 90.5%) [OR =4.35; 95%CI 2.25 -8.39; p<0 .001] compared to the US group. The diagnostic accuracy of the CEUS group was 95.6 % (1964/2054), while that of the US group was 90.5% (1729/1909). The combined analysis indicated significant advantages for CEUS over US [(OR = 2.36). 95 %CI 1.81-3.09, p<0.001].
CONCLUSIONS
CEUS is superior to US in the diagnostic performance, single puncture success rate, pathological diagnosis rate and diagnostic accuracy of liver biopsy in patients with liver lesions.
PubMed: 38808493
DOI: 10.11152/mu-4374 -
Rheumatology International Oct 2023For knee osteoarthritis and related conditions, analysis of biomarkers hold promise to improve early diagnosis and/or offer patient-specific treatment. To compare... (Review)
Review
For knee osteoarthritis and related conditions, analysis of biomarkers hold promise to improve early diagnosis and/or offer patient-specific treatment. To compare biomarker analyses, reliable, high-quality biopsies are needed. The aim of this work is to summarize the literature on the current best practices of biopsy of the synovium and synovial fluid arthrocentesis. Therefore, PubMed, Embase and Web of Science were systematically searched for articles that applied, demonstrated, or evaluated synovial biopsies or arthrocentesis. Expert recommendations and applications were summarized, and evidence for superiority of techniques was evaluated. Thirty-one studies were identified for inclusion. For arthrocentesis, the superolateral approach in a supine position, with a 0°-30° knee flexion was generally recommended. 18-gage needles, mechanical compression and ultrasound-guidance were found to give superior results. For blind and image-guided synovial biopsy techniques, superolateral and infrapatellar approaches were recommended. Single-handed tools were preconized, including Parker-Pearson needles and forceps. Sample quantity ranged approximately from 2 to 20. Suggestions were compiled for arthrocentesis regarding approach portal and patient position. Further evidence regarding needle size, ultrasound-guidance and mechanical compression were found. More comparative studies are needed before evidence-based protocols can be developed.
Topics: Humans; Arthrocentesis; Synovial Fluid; Knee Joint; Biopsy; Synovial Membrane
PubMed: 36513849
DOI: 10.1007/s00296-022-05256-4 -
Endocrine-related Cancer Jul 2023Core needle biopsy (CNB) has been used with caution in pheochromocytoma and paraganglioma (PPGL) due to concerns about catecholamine-related complications. While it is... (Meta-Analysis)
Meta-Analysis
Core needle biopsy (CNB) has been used with caution in pheochromocytoma and paraganglioma (PPGL) due to concerns about catecholamine-related complications. While it is unclear what scientific evidence supports this claim, it has limited the acquisition of biological samples for diagnostic purposes and research, especially in metastatic PPGL. We performed a systematic review and individual patient meta-analysis to evaluate the risk of complications after CNB in PPGL patients. The primary and secondary objectives were to investigate the risk of death and the occurrence of complications requiring intervention or hospitalization, respectively. Fifty-six articles describing 86 PPGL patients undergoing CNB were included. Of the patients (24/71), 34% had metastases and 53.4% (31/58) had catecholamine-related symptoms before CNB. Of the patients (14/41), 34.1% had catecholamine excess testing prior to the biopsy. No CNB-related deaths were reported. Four patients (14.8%, 4/27) experienced CNB-related complications requiring hospitalization or intervention. One case had a temporary duodenal obstruction caused by hematoma, two cases had myocardial infarction, and one case had Takotsubo cardiomyopathy. Eight patients (32%, 8/25) had CNB-related catecholamine symptoms, mainly transient hypertension, excessive diaphoresis, tachycardia, or hypertensive crisis. The scientific literature does not allow us to make any firm conclusion on the safety of CNB in PPGL. However, it is reasonable to argue that CNB could be conducted after thorough consideration, preparation, and with close follow-up for PPGL patients with a strong clinical indication for such investigation.
Topics: Humans; Pheochromocytoma; Biopsy, Large-Core Needle; Paraganglioma; Catecholamines; Adrenal Gland Neoplasms; Retrospective Studies
PubMed: 37185155
DOI: 10.1530/ERC-22-0354 -
European Urology Focus Dec 2023There are several procedures for surgical nodal staging in clinically node-negative (cN0) penile carcinoma. (Review)
Review
CONTEXT
There are several procedures for surgical nodal staging in clinically node-negative (cN0) penile carcinoma.
OBJECTIVE
To evaluate the diagnostic accuracy, perioperative outcomes, and complications of minimally invasive surgical procedures for nodal staging in penile carcinoma.
EVIDENCE ACQUISITION
A systematic review of the Medline, Embase, and Cochrane controlled trials databases and ClinicalTrials.gov was conducted. Published and ongoing studies reporting on the management of cN0 penile cancer were included without any design restriction. Outcomes included the false negative (FN) rate, the number of nodes removed, surgical time, and postoperative complications.
EVIDENCE SYNTHESIS
Forty-one studies were eligible for inclusion. Four studies comparing robot-assisted (RA-VEIL) and video-endoscopic inguinal lymphadenectomy (VEIL) to open inguinal lymph node dissection (ILND) were suitable for meta-analysis. A descriptive synthesis was performed for single-arm studies on modified open ILND, dynamic sentinel node biopsy (DSNB) with and without preoperative inguinal ultrasound (US), and fine-needle aspiration cytology (FNAC). DSNB with US + FNAC had lower FN rates (3.5-22% vs 0-42.9%) and complication rates (Clavien Dindo grade I-II: 1.1-20% vs 2.9-11.9%; grade III-V: 0-6.8% vs 0-9.4%) in comparison to DSNB alone. Favourable results were observed for VEIL/RA-VEIL over open ILND in terms of major complications (2-10.6% vs 6.9-40.6%; odds ratio [OR] 0.18; p < 0.01). Overall, VEIL/RA-VEIL had lower wound-related complication rates (OR 0.14; p < 0.01), including wound infections (OR 0.229; p < 0.01) and skin necrosis (OR 0.16; p < 0.01). The incidence of lymphatic complications varied between 20.6% and 49%.
CONCLUSIONS
Of all the surgical staging options, DSNB with inguinal US + FNAC had the lowest complication rates and high diagnostic accuracy, especially when performed in high-volume centres. If DSNB is not available, favourable results were also found for VEIL/RA-VEIL over open ILND. Lymphatic-related complications were comparable across open and video-endoscopic ILND.
PATIENT SUMMARY
We reviewed studies on different surgical approaches for assessing lymph node involvement in cases with penile cancer. The results show that a technique called dynamic sentinel node biopsy with ultrasound guidance and fine-needle sampling has high diagnostic accuracy and low complication rates. For lymph node dissection in penile cancer cases, a minimally invasive approach may offer favourable postoperative outcomes.
PubMed: 38071107
DOI: 10.1016/j.euf.2023.11.010 -
Clinical Radiology Oct 2023To evaluate the diagnostic value and safety of ultrasound-guided core-needle biopsy for peripheral pulmonary lesions (PPLs). (Meta-Analysis)
Meta-Analysis
AIM
To evaluate the diagnostic value and safety of ultrasound-guided core-needle biopsy for peripheral pulmonary lesions (PPLs).
MATERIALS AND METHODS
PubMed, EMBASE, and the Cochrane Library for relevant were searched for studies published up to June 2022. The diagnostic accuracy of US-guided percutaneous transthoracic needle biopsy (PTNB) for the diagnosis of PPLs was evaluated using pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive and negative likelihood ratios (PLR and NLR), and the area under the summary receiver operating characteristic curves value (SROC).
RESULTS
The search included 12 original studies (3,830 procedures). For US-guided PTNB, the pooled sensitivity and specificity for the diagnosis of PPLs were 0.93 (95% confidence interval [CI]: 0.91-0.94) and 0.99 (95% CI: 0.96-1.00), respectively. The pooled estimates of the PLR, NLR, and DOR were 134.88 (95% CI: 24.88-731.74), 0.07 (95% CI: 0.06-0.09), and 1,814.95 (95% CI: 333.62-9,873.76), respectively. The area under the SROC curve was 0.95 (95% CI: 0.93-0.97). The overall complication rate was 3.6% (136 of 3,830), including self-limited haemoptysis and asymptomatic pneumothorax, and only six cases of pneumothorax requiring chest tube drainage and one case of severe bleeding were reported.
CONCLUSIONS
US-guided core-needle biopsy is an excellent diagnostic tool for PPLs, with high accuracy and excellent technical performance and safety.
Topics: Humans; Pneumothorax; Image-Guided Biopsy; Biopsy, Large-Core Needle; Sensitivity and Specificity; Ultrasonography, Interventional
PubMed: 37558538
DOI: 10.1016/j.crad.2023.07.005 -
Pediatric Blood & Cancer Feb 2024Image-guided core-needle biopsy (IGCNB) is a widely used and valuable clinical tool for tissue diagnosis of pediatric neuroblastoma. However, open surgical biopsy... (Meta-Analysis)
Meta-Analysis Review
Image-guided core-needle or surgical biopsy for neuroblastoma diagnosis in children: A systematic review and meta-analysis from the International Society of Pediatric Surgical Oncology (IPSO).
BACKGROUND
Image-guided core-needle biopsy (IGCNB) is a widely used and valuable clinical tool for tissue diagnosis of pediatric neuroblastoma. However, open surgical biopsy remains common practice even if children undergo more invasive and painful procedures. This review aims to determine the diagnostic accuracy and safety of IGCNBs in pediatric patients with neuroblastoma.
METHODS
We conducted a systematic review of peer-reviewed original articles published between 1980 and 2023, by searching "pediatric oncology," "biopsy," "interventional radiology," and "neuroblastoma." Exclusion criteria were patients older than 18 years, studies concerning non-neurogenic tumors, case reports, and language other than English. Both the systematic review and meta-analysis were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement.
RESULTS
A total of 533 abstracts articles were analyzed. Of these, eight retrospective studies met inclusion criteria (490 infants, 270 surgical biopsies [SB], 220 image-guided biopsies). Tissue adequacy for primary diagnosis (SB: n = 265, 98%; IGCNB: n = 199, 90%; p = .1) and biological characterization (SB: n = 186, 95%; IGCNB: n = 109, 89%; p = .15) was similar with both biopsy techniques, while intraoperative transfusion rate (SB: n = 51, 22%; IGCNB: n = 12, 6%; p = .0002) and complications (%) (SB: n = 58, 21%; IGCNB: n = 14, 6%; p = .005) were higher with surgical biopsy. Length of stay was similar in both groups; however, no additional data about concurrent diagnostic or treatment procedures were available in the analyzed studies.
CONCLUSIONS
IGCNB is a safe and effective strategic approach for diagnostic workup of NB and should be considered in preferance to SB wherever possible.
Topics: Infant; Child; Humans; Surgical Oncology; Retrospective Studies; Neuroblastoma; Image-Guided Biopsy
PubMed: 38015091
DOI: 10.1002/pbc.30789 -
Digestive Diseases and Sciences Oct 2023Transjugular liver biopsy (TJLB) procedurally samples liver tissue through the internal jugular vein. It is indicated in the presence of coagulopathies and/or ascites. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Transjugular liver biopsy (TJLB) procedurally samples liver tissue through the internal jugular vein. It is indicated in the presence of coagulopathies and/or ascites.
AIMS
This meta-analysis aimed to assess the safety and efficacy of TJLB in children.
METHODS
A literature search of several databases was conducted from inception to August 2022. Eligible studies reported pediatric patients (< 18 years old) who underwent TJLB. The pooled proportion was analyzed using a random-effects model. This review was registered in PROSPERO (CRD42022354421).
RESULTS
From 921 initial studies screened, eight met the eligibility criteria, with a total of 361 pediatric patients who underwent 374 TJLBs. All eight studies reported pooled rates of technical success at 99.1% (95% CI 0.982, 1.001; I = 0%) and histological adequacy of sampling at 97.5% (95% CI 0.954, 0.995; I = 27.66%). A total of 49 complications were reported across six studies, the most common being bleeding from the entry site (38.78%), fevers for less than 24 h (12.24%), red blood cells transfusion requirement (10.2%), supraventricular tachycardia (8.16%), and pain requiring analgesia (8.16%).
CONCLUSION
Pediatric TJLB demonstrates high rates of technical success and adequate liver core biopsy samples, with a low rate of complications. These results suggest that TJLB is an effective method for diagnostic yield and postprocedural outcomes, especially in patients with preexisting coagulopathies and ascites where percutaneous liver biopsy is contraindicated. Additional studies evaluating larger groups of pediatric patients may provide further support for the use of TJLB in this population.
Topics: Humans; Child; Adolescent; Ascites; Liver; Biopsy; Biopsy, Needle; Digestive System Surgical Procedures; Pain; Liver Diseases; Retrospective Studies
PubMed: 37555881
DOI: 10.1007/s10620-023-08071-4 -
Journal of Plastic, Reconstructive &... Mar 2024Implant-based breast augmentations and reconstructions are one of the most common surgical procedures performed by plastic surgeons in the United States, which has... (Review)
Review
INTRODUCTION
Implant-based breast augmentations and reconstructions are one of the most common surgical procedures performed by plastic surgeons in the United States, which has rapidly increased in popularity since the 2000s. Silicone lymphadenopathy (SL) is a complication of breast implants that involves migration of silicone to nearby soft tissue/lymph nodes. Data on its clinical features and management is scarce.
METHODS
SL-related search terms were used to find articles in 3 databases. Of 598 articles, 101 studies met the inclusion criteria. Demographics, clinical presentation, workup, and management data were analyzed.
RESULTS
Of 279 cases of SL and 107 with information on initial diagnosis, 35 (33%) were incidental. The most common symptom was painless lymphadenopathy, followed by painful lymphadenopathy. 251 (95%) and 13 (5%) patients had silicone and saline implants, respectively. 149 (68%) patients had implant rupture. Axillary lymphadenopathy was the most affected region (136 cases, 72%), followed by internal mammary (40 cases, 21%), cervical/supraclavicular (36 cases, 19%), and mediastinal (24 cases, 13%) regions. 25% of patients underwent fine-needle aspiration, 12% core needle biopsy, and 59% excisional biopsy. 32% of cases underwent explantation and/or implant exchange. The most common indication for surgery was implant rupture. Histology showed multinucleated giant cells, large histiocytes, and silicone accumulation.
CONCLUSIONS
SL is a complication associated with breast implants. The majority of patients are asymptomatic, and most cases are managed conservatively. Minority need a biopsy and surgical interventions due to abnormal imaging, persistent symptoms, and/or implant rupture. Workup and management should be tailored to the patient.
Topics: Humans; Silicone Gels; Prevalence; Lymphadenopathy; Breast Implants; Breast Implantation
PubMed: 38364672
DOI: 10.1016/j.bjps.2024.01.011