The Journal of Invasive Cardiology Jul 2023A 76-year-old female with severe symptomatic aortic stenosis underwent cardiac CT angiography imaging. Severe calcification of the ascending aorta (porcelain aorta)...
A 76-year-old female with severe symptomatic aortic stenosis underwent cardiac CT angiography imaging. Severe calcification of the ascending aorta (porcelain aorta) (Figures 1A and 1B) precluded surgical aortic valve replacement. The aortic annular area, perimeter, and diameter were 372 mm2, 68.5 mm, and 20 mm, respectively. Transcatheter aortic valve replacement (TAVR) was performed with direct implantation of a 23 mm Sapien S3 valve (Edwards Lifesciences). The valve was delivered via the right femoral artery and a pigtail catheter was delivered to the aortic root via the left femoral artery. The balloon ruptured during valve implantation (Video).
Topics: Female; Humans; Aged; Transcatheter Aortic Valve Replacement; Aortic Valve Stenosis; Aortic Valve; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Treatment Outcome; Prosthesis Design
PubMed: 37769616
DOI: No ID Found -
JACC. Cardiovascular Interventions Apr 2024
Topics: Humans; Transcatheter Aortic Valve Replacement; Treatment Outcome; Cardiac Pacing, Artificial; Aortic Valve Stenosis; Aortic Valve; Time Factors; Heart Rate; Risk Factors; Heart Valve Prosthesis; Pacemaker, Artificial
PubMed: 38658117
DOI: 10.1016/j.jcin.2024.03.003 -
Circulation. Cardiovascular... Nov 2023
Topics: Humans; Aortic Valve; Transcatheter Aortic Valve Replacement; Feasibility Studies; Treatment Outcome; Heart Valve Prosthesis Implantation; Aortic Valve Stenosis; Heart Valve Prosthesis; Risk Factors; Reoperation
PubMed: 37988435
DOI: 10.1161/CIRCINTERVENTIONS.123.013571 -
Biology of Sex Differences Oct 2023Aortic stenosis (AS) is characterized by inflammation, fibrosis, osteogenesis and angiogenesis. Men and women develop these mechanisms differently. Galectin-3 (Gal-3) is...
BACKGROUND
Aortic stenosis (AS) is characterized by inflammation, fibrosis, osteogenesis and angiogenesis. Men and women develop these mechanisms differently. Galectin-3 (Gal-3) is a pro-inflammatory and pro-osteogenic lectin in AS. In this work, we aim to analyse a potential sex-differential role of Gal-3 in AS.
METHODS
226 patients (61.50% men) with severe AS undergoing surgical aortic valve (AV) replacement were recruited. In AVs, Gal-3 expression and its relationship with inflammatory, osteogenic and angiogenic markers was assessed. Valve interstitial cells (VICs) were primary cultured to perform in vitro experiments.
RESULTS
Proteomic analysis revealed that intracellular Gal-3 was over-expressed in VICs of male AS patients. Gal-3 secretion was also higher in men's VICs as compared to women's. In human AVs, Gal-3 protein levels were significantly higher in men, with stronger immunostaining in VICs with myofibroblastic phenotype and valve endothelial cells. Gal-3 levels in AVs were positively correlated with inflammatory markers in both sexes. Gal-3 expression was also positively correlated with osteogenic markers mainly in men AVs, and with angiogenic molecules only in this sex. In vitro, Gal-3 treatment induced expression of inflammatory, osteogenic and angiogenic markers in male's VICs, while it only upregulated inflammatory and osteogenic molecules in women-derived cells. Gal-3 blockade with pharmacological inhibitors (modified citrus pectin and G3P-01) prevented the upregulation of inflammatory, osteogenic and angiogenic molecules.
CONCLUSIONS
Gal-3 plays a sex-differential role in the setting of AS, and it could be a new sex-specific therapeutic target controlling pathological features of AS in VICs.
Topics: Female; Humans; Male; Aortic Valve; Aortic Valve Stenosis; Endothelial Cells; Galectin 3; Proteomics
PubMed: 37875993
DOI: 10.1186/s13293-023-00556-1 -
Computers in Biology and Medicine Mar 2024Aortic valve disease is often treated with bioprosthetic valves. An alternative treatment is aortic valve neocuspidization which is a relatively new reparative procedure...
Aortic valve disease is often treated with bioprosthetic valves. An alternative treatment is aortic valve neocuspidization which is a relatively new reparative procedure whereby the three aortic cusps are replaced with patient pericardium or bovine tissues. Recent research indicates that aortic blood flow is disturbed, and turbulence effects have yet to be evaluated in either bioprosthetic or aortic valve neocuspidization valve types in patient-specific settings. The aim of this study is to better understand turbulence production in the aorta and evaluate its effects on laminar and turbulent wall shear stress. Four patients with aortic valve disease were treated with either bioprosthetic valves (n=2) or aortic valve neocuspidization valvular repair (n=2). Aortic geometries were segmented from magnetic resonance images (MRI), and 4D flow MRI was used to derive physiological inlet and outlet boundary conditions. Pulsatile large-eddy simulations were performed to capture the full range of laminar, transitional and turbulence characteristics in the aorta. Turbulence was produced in all aortas with highest levels occurring during systolic deceleration. In the ascending aorta, turbulence production is attributed to a combination of valvular skew, valvular eccentricity, and ascending aortic dilation. In the proximal descending thoracic aorta, turbulence production is dependent on the type of arch-descending aorta connection (e.g., a narrowing or sharp bend) which induces flow separation. Laminar and turbulent wall shear stresses are of similar magnitude throughout late systolic deceleration and diastole, although turbulent wall shear stress magnitudes exceed laminar wall shear stresses between 27.3% and 61.1% of the cardiac cycle. This emphasises the significance of including turbulent wall shear stress to improve our comprehension of progressive arterial wall diseases. The findings of this study recommend that aortic valve treatments should prioritise minimising valvular eccentricity and skew in order to mitigate turbulence generation.
Topics: Humans; Animals; Cattle; Aortic Valve; Blood Flow Velocity; Hemodynamics; Aorta; Aortic Valve Disease; Stress, Mechanical
PubMed: 38354498
DOI: 10.1016/j.compbiomed.2024.108123 -
The Journal of Thoracic and... Aug 2023Existing replacement options for the aortic valve have significant drawbacks, especially in children. A geometric annuloplasty ring can help to achieve consistently...
OBJECTIVE
Existing replacement options for the aortic valve have significant drawbacks, especially in children. A geometric annuloplasty ring can help to achieve consistently successful aortic valve repair, but only limited experience with use of this device has been reported in pediatric and congenital heart disease patients.
METHODS
All pediatric and adult congenital patients at our institution who underwent aortic valve repair with placement of a geometric annuloplasty ring were reviewed. The study period spanned from July 2018 to April 2022. Hemodynamic outcomes were evaluated using transthoracic echocardiography.
RESULTS
The study included 36 subjects. The median age was 17.4 years (range, 8-30 years). Twenty-one subjects were younger than age 18 years. The most common primary diagnoses were neoaortic valve insufficiency or neoaortic root dilation, and congenital aortic stenosis with bicuspid or functionally unicuspid aortic valve. Of the 34 subjects with procedural success, 31 (91%) had use of additional valve repair techniques and 26 (76%) had an additional concomitant procedure performed. Operative mortality was 0% (0/33), and major complication rate was 6% (2/33). The median follow-up time was 1.9 years (maximum, 3.8 years). The mean grade of aortic insufficiency was signific antly reduced after repair, with no change in mean gradients. Freedom from reoperation over the follow-up period was 97% (33/34), and freedom from ≥3+ recurrent aortic insufficiency was 94% (32/34).
CONCLUSIONS
A geometric annuloplasty ring can be used to help achieve consistently successful aortic valve repair with excellent perioperative and follow-up outcomes, even in pediatric and complex congenital heart disease patients.
Topics: Adult; Humans; Child; Adolescent; Aortic Valve; Heart Valve Prosthesis; Cardiac Valve Annuloplasty; Aortic Valve Insufficiency; Heart Defects, Congenital; Reoperation; Treatment Outcome
PubMed: 36404145
DOI: 10.1016/j.jtcvs.2022.10.017 -
Cardiovascular Revascularization... May 2024
Topics: Humans; Aortic Valve Stenosis; Calcinosis; Aortic Valve; Risk Factors; Comorbidity; Heart Valve Prosthesis Implantation; Treatment Outcome
PubMed: 38195344
DOI: 10.1016/j.carrev.2023.12.018 -
The American Journal of Cardiology Dec 2023Low-flow low-gradient (LF-LG) aortic stenosis (AS) may occur with preserved or depressed left ventricular ejection fraction (LVEF). Both situations represent the most...
Low-flow low-gradient (LF-LG) aortic stenosis (AS) may occur with preserved or depressed left ventricular ejection fraction (LVEF). Both situations represent the most challenging subset of patients to manage and generally have a poor prognosis. Few and controversial data exist on the outcomes of these patients compared with normal flow-high gradient (NF-HG) AS after transcatheter aortic valve replacement (TAVR). We sought to characterize different transvalvular flow-gradient patterns and to examine their prognostic value after TAVR. We enrolled 1,208 patients with severe AS and categorized as follow: 976 patients NF-HG (mean aortic pressure gradient [MPG] ≥40 mm Hg), 107 paradoxical LF-LG (pLF-LG, MPG <40 mm Hg, LVEF ≥50%, stroke volume index <35 ml/m), and 125 classical LF-LG (cLF-LG) (MPG <40 mm Hg, LVEF <50%, stroke volume index <35 ml/m). When compared with NF-HG and pLF-LG, cLF-LG had a worse symptomatic status (New York Heart Association III to IV 86% vs 62% and 67%, p <0.001), a higher prevalence of eccentric hypertrophy and a higher level of LV global afterload reflected by a higher valvuloarterial impedance. Valvular function after TAVR was excellent over time in all patients. While 30-day mortality (p = 0.911) did not differ significantly among groups, cLF-LG had a lower 5-year survival rate (LF-LG 50% vs pLF-LG 62% and NF-HG 68%, p <0.05). cLF-LG was associated with a hazard ratio for mortality of 2.41 (95% confidence interval 1.65 to 3.52, p <0.001). In conclusion, TAVR is an effective procedure regardless of transvalvular flow-gradient patterns. However, special care should be given to characterized hemodynamic of AS, as patients with pLF-LG had similar survival rates than patients with NF-HG, whereas cLF-LG is associated with a twofold increased risk of mortality at 5-year follow-up.
Topics: Humans; Transcatheter Aortic Valve Replacement; Stroke Volume; Ventricular Function, Left; Treatment Outcome; Aortic Valve Stenosis; Aortic Valve; Severity of Illness Index
PubMed: 37858597
DOI: 10.1016/j.amjcard.2023.09.095 -
Catheterization and Cardiovascular... Dec 2023To report our single-center data, regarding the first 100 patients who underwent TAVR procedure with the new balloon-expandable MYVAL system. We report 30-day and 1-year...
AIMS
To report our single-center data, regarding the first 100 patients who underwent TAVR procedure with the new balloon-expandable MYVAL system. We report 30-day and 1-year outcomes in low to high-risk TAVR patient population.
METHODS
From November 2019 to July 2021, 100 consecutive patients underwent TAVR procedure. Patient outcome was classified according to the VARC-2 definitions. The device performance was assessed using transthoracic echocardiography. Data collection was allowed by the Local Ethical Committee.
RESULTS
The mean age was 74.7 years, 63 (63%) were male. The mean Euroscore II and STS score were 4.8 ± 4.9 and 5.6 ± 3.9, respectively. Transfemoral access was the most frequent (surgical vs. percutaneous 2% vs. 97%) and in one patient surgical subclavian access was used. VARC-2 outcomes were as follows: device success 99%, STROKE 1%, major and minor vascular complication was 1% and 11%, respectively, the rate of new permanent pacemaker implantation was 30.7%. At discharge, the incidence of grade I, grade II aortic regurgitation was 39% and 1%, respectively, without relevant PVL. In-hospital mortality was only 1%. These results included a high proportion (17%) of patients with bicuspid aortic valves. At 1 year, the all-cause mortality rate was 7% (only two due to cardiac event) and only a single patient had valve-related dysfunction requiring surgical aortic replacement.
CONCLUSIONS
TAVR procedure with MYVAL transcatheter heart valve system shows excellent 30-day and 1-year outcomes regarding patient survival, technical success, and valve-related adverse events. The limitations of our study comprise a single-center study with retrospective data collection.
Topics: Humans; Male; Aged; Female; Aortic Valve; Aortic Valve Stenosis; Transcatheter Aortic Valve Replacement; Follow-Up Studies; Retrospective Studies; Treatment Outcome; Heart Valve Prosthesis; Prosthesis Design
PubMed: 37870123
DOI: 10.1002/ccd.30868 -
Multimedia Manual of Cardiothoracic... Mar 2024Micro-invasive totally endoscopic aortic valve replacement surgery is a minimally invasive cardiac procedure that can be performed with the help of several techniques...
Micro-invasive totally endoscopic aortic valve replacement surgery is a minimally invasive cardiac procedure that can be performed with the help of several techniques and technologies that employ the latest innovations in instrumentation and technological advances in the field, thereby greatly limiting the overall invasiveness of the procedure. With the help of a 3-dimensional camera, long instruments, a very small thoracotomy and a soft-tissue retractor without any rib retractor, the aortic valve can be easily and safely accessed for replacement. The other main features of these techniques are extracorporeal circulation that is achieved through peripheral percutaneous cannulation of the femoral vessels, antegrade cardioplegia, the use of automated devices for suturing the valvular ring and the prosthetic suture cuff, namely the RAM device, the Sew-Easy device and the Cor-Knot Mini device. Additionally, an automated vascular closure device such as the MANTA device is later used to close the femoral artery following decannulation.
Topics: Humans; Aortic Valve; Catheters; Endoscopy; Femoral Artery; Lower Extremity
PubMed: 38530245
DOI: 10.1510/mmcts.2023.094