Bovine Viral Diarrhea Virus (BVDV) and Infectious Bovine Rhinotracheitis Virus (IBRV) are the two most prevalent infectious diseases in cattle. They both can cause persistent infection and immunosuppression, resulting in significant economic losses in the livestock industry. Therefore, rapid detection of early BVDV and IBRV infections is crucial. In this study, a method for the rapid detection of BVDV and IBRV was established by using recombinase polymerase amplification (RPA) combined with lateral flow device (LFD). By optimizing the temperature and time conditions of the RPA reaction, the sensitivity, specificity, and clinical performance were evaluated. The results indicated that the RPA reaction could be completed at 40°C within 25 min. The LOD for BVDV and IBRV by RPA-LFD were 5.1 × 10 copies/μL and 6.65 × 10 copies/μL, respectively, with no cross-reactivity observed with other viruses such as CSFV, BRSV, BPIV3, BRV, and BCoV. Testing of 32 clinical samples showed consistent results between RPA-LFD and qPCR. The RPA-LFD method established in this study can be used for the rapid clinical detection of BVDV and IBRV, which providing a rapid and convenient molecular biology approach for on-site rapid detection and epidemiological investigations. Simultaneously, it offers technical support for the prevention and control of these viruses.
PubMed: 38601910
DOI: 10.3389/fvets.2024.1360504 -
Journal of Wound, Ostomy, and...To assess the performance of a new urinary intermittent catheter (IC) prototype designed with a micro-hole drainage zone compared to a conventional eyelet catheter (CEC)... (Randomized Controlled Trial)
Randomized Controlled Trial
Improved Performance With the Micro-Hole Zone Intermittent Catheter: A Combined Analysis of 3 Randomized Controlled Studies Comparing the New Catheter Technology With a Conventional Eyelet Catheter.
PURPOSE
To assess the performance of a new urinary intermittent catheter (IC) prototype designed with a micro-hole drainage zone compared to a conventional eyelet catheter (CEC) in terms of flow-stop, bladder emptying, and hematuria.
DESIGN
Randomized controlled crossover studies.
SUBJECT AND SETTING
The sample comprised 15 male healthy volunteers (HV) and 15 IC users, along with 15 female HV and 15 IC users. The age range was lower for HV participants than for IC users (range: 20-57 years for HV vs 21-82 years for IC users). The study setting was the Department of Urology, located in Rigshospitalet, Copenhagen.
METHODS
Number of flow-stop incidents, residual urine volume at first flow-stop (RV1), and dipstick hematuria were measured during and after catheterization by a health care professional (HV) and by self-catheterisation (IC-users). Results from the 3 studies were combined for HV and IC users on RV1 and number of flow-stop incidents but separated on sex. For incidents of hematuria, an effect of underlying condition was assumed, and a combined analysis on sex was performed, separating HV and IC users.
RESULTS
When compared to the micro-hole drainage zone design, catheterizations with CEC resulted in a significantly higher mean RV1 (mean difference: 49 mL in males and 32 mL in females, both P < .001) and average number of flow-stop incidents (8 and 21 times more frequent for males and females, respectively, both P < .001). The likelihood for hematuria was 5.84 higher with CEC than with micro-hole drainage hole design, P = .053, during normal micturition in HV postcatheterization. No serious adverse events were reported.
CONCLUSION
The micro-hole drainage zone catheter provides IC users fewer premature flow-stops. This design feature reduces modifiable urinary tract infection risk factors, such as residual urine and micro-trauma; additional research is needed to determine its effects on bladder health.
Topics: Adult; Female; Humans; Male; Middle Aged; Young Adult; Hematuria; Technology; Urinary Bladder; Urinary Catheterization; Urinary Catheters; Urinary Tract Infections; Cross-Over Studies
PubMed: 37966080
DOI: 10.1097/WON.0000000000001029 -
Clinica Chimica Acta; International... Oct 2023Urinalysis is essential for diagnosing kidney-related medical conditions. Urine test strip analysis serves as an initial and efficient screening method for reflex...
INTRODUCTION
Urinalysis is essential for diagnosing kidney-related medical conditions. Urine test strip analysis serves as an initial and efficient screening method for reflex testing with accurate quantitative methods.
MATERIALS AND METHODS
Freshly voided urines (n = 206) were analysed using two urine test strip brands on UC-MAX (Menarini) and cobas u 601 (Roche Diagnostics) instruments. Ordinal scale categories and reflectance signals (if available) were both used for the comparison with reference quantitative methods for glucose, proteins and albumin (cobas 503). Samples were considered positive when glucose > 15 or ≥ 54 mg/dL, proteins ≥ 200 mg/L and albumin ≥ 10 mg/L. Optimized reflectance thresholds were calculated by ROC curve analysis. Analytical performance specifications (APS) for trueness of test strip were gathered from the EFLM guideline (FP, FN, FN).
RESULTS
Reflectance signals were significantly lower in urine samples considered positive by the reference method (p < 0.0001). Reflectance signals were also correlated with quantitative measurements, showing strong correlation (0.754 to 0.969). Only the use of optimized reflectance thresholds on cobas u 601 achieved at least the minimum EFLM APS (FP < 20%, FN < 50% and FN < 10%).
CONCLUSION
The use of reflectance signals from urine test strips enhanced accuracy for glucose, proteins, and albumin measurement and may contribute to improve diagnosis of diverse kidney-related conditions.
Topics: Humans; Reagent Strips; Urinalysis; Glucose; Proteins; Albumins
PubMed: 37739023
DOI: 10.1016/j.cca.2023.117534 -
Luminescence : the Journal of... May 2024Fluorene nucleus derivatives show great potential for building outstanding fluorescence probes. In this paper, a novel fluorescent probe was developed by reacting with...
Fluorene nucleus derivatives show great potential for building outstanding fluorescence probes. In this paper, a novel fluorescent probe was developed by reacting with fluorene core with azacyclobutane, which exhibits typical solvation chromogenic effect in solvent. The fluorescence of the probe quenched in highly polar solvent. Based on this phenomenon, a novel fluorescence system for trace water was constructed. The response of this probe was fast (30 s) and sensitive for the detection of trace water in organic solvents, and the detection limit of water content in DMSO reached 0.13%. In addition, the probe can also be made as a test strip combined with homemade portable device and a smartphone for rapid detection of trace water. The luminescence mechanism of the probe is theoretically calculated based on time-contained density functional theory (TDDFT). To showcase its practicality, it has been applied for the detection of trace water in honey and alcohol by dipstick. This method provides a new idea for designing efficient fluorescent probes based on dipstick and mobile phone rapid detection.
Topics: Fluorescent Dyes; Fluorenes; Water; Spectrometry, Fluorescence; Molecular Structure; Limit of Detection; Density Functional Theory; Fluorescence; Water Pollutants, Chemical
PubMed: 38720528
DOI: 10.1002/bio.4769 -
Kidney360 Jun 2024
Topics: Humans; Proteinuria; Urinalysis; Reagent Strips; Specific Gravity; Male; Female; Middle Aged; Adult; Aged
PubMed: 38664867
DOI: 10.34067/KID.0000000000000452 -
Acta Tropica Aug 2024The World Health Organization calls for schistosomiasis endemic countries to regularly monitor the efficacy of Praziquantel (PZQ) drug, the only antischistosomal drug...
Efficacy of praziquantel drug against Schistosoma haematobium and performance of urine reagent strips among pre-and-school aged children during the high transmission season in North-Western Tanzania.
The World Health Organization calls for schistosomiasis endemic countries to regularly monitor the efficacy of Praziquantel (PZQ) drug, the only antischistosomal drug used for four decades in Tanzania. In response to that call, the current study investigated the efficacy of single dose of PZQ against Schistosoma haematobium during the high transmission season and further assessed, the sensitivity and specificity of urine reagent strips before and after treatment. The study recruited a total of 2,498 -children aged (4 -17 years old) who provided a single urine sample that was visually examined for macro-haematuria, then using urine dipstick and urine filtration technique for microhaematuria and the presence of S. haematobium eggs. The baseline prevalence of S. haematobium eggs positive based on urine filtration test was 29.2 % (95 %CI:27.5-31.0) and that of microhaematuria was 43.1 % (95 %CI:41.1-45.0). Of the infected participants, 40.9 % (95 %CI:37.4-44.6) had a heavy intensity of infection and the geometrical mean intensity (GMI) of infection was 33.7 eggs/10mls of urine. A single dose of PZQ reduced the prevalence of infection to 16.2 %, the GMI of infection to 18.8eggs/10mls of urine and that of microhaematuria to 27.9 %. Cure rate and egg reduction rates (ERR) were 83.8 % and 44.3 % respectively. At baseline, the sensitivity and specificity of the urine reagent strips were 59.7 % and 93.8 %, whereas at post-treatment they were 16.7 % and 93.6 %. When PZQ drug is administered during the high transmission season, its efficacy in term of ERR is poor. The urine reagent strips had low sensitivity but high specificity at pre-and-post PZQ treatment.
Topics: Praziquantel; Tanzania; Humans; Schistosomiasis haematobia; Child; Animals; Child, Preschool; Female; Male; Sensitivity and Specificity; Anthelmintics; Schistosoma haematobium; Adolescent; Reagent Strips; Prevalence; Urine; Treatment Outcome; Parasite Egg Count
PubMed: 38729329
DOI: 10.1016/j.actatropica.2024.107232 -
Physical Chemistry Chemical Physics :... Jun 2024The vanadium redox flow battery (VRFB) is considered a promising candidate for large-scale energy storage in the transition from fossil fuels to renewable energy...
The vanadium redox flow battery (VRFB) is considered a promising candidate for large-scale energy storage in the transition from fossil fuels to renewable energy sources. VRFBs store energy by electrochemical reactions of different electroactive species dissolved in electrolyte solutions. The redox couples of VRFBs are VO/VO and V/V, the ratio of which to the total vanadium content determines the state of charge (SOC). V(IV) and V(II) are paramagnetic half-integer spin species detectable and quantifiable with electron paramagnetic resonance spectroscopy (EPR). Common commercial EPR spectrometers, however, employ microwave cavity resonators which necessitate the use of large electromagnets, limiting their application to dedicated laboratories. For an SOC monitoring device for VRFBs, a small, cost-effective submersible EPR spectrometer, preferably with a permanent magnet, is desirable. The EPR-on-a-Chip (EPRoC) spectrometer miniaturises the complete EPR spectrometer onto a single microchip by utilising the coil of a voltage-controlled oscillator as both microwave source and detector. It is capable of sweeping the frequency while the magnetic field is held constant enabling the use of small permanent magnets. This drastically reduces the experimental complexity of EPR. Hence, the EPRoC fulfils the requirements for an SOC sensor. We, therefore, evaluate the potential for utilisation of an EPRoC dipstick spectrometer as an operando and continuously online monitor for the SOC of VRFBs. Herein, we present quantitative proof-of-principle submersible EPRoC experiments on variably charged vanadium electrolyte solutions. EPR data obtained with a commercial EPR spectrometer are in good agreement with the EPRoC data.
PubMed: 38874514
DOI: 10.1039/d4cp00373j -
Tropical Medicine and Infectious Disease Jun 2024Echinococcosis poses a significant concern in the fields of public health and veterinary care as it can be transmitted between animals and humans. The primary endemic...
Rapid Discriminative Identification of the Two Predominant Echinococcus Species from Canine Fecal Samples in the Tibetan Region of China by Loop-Mediated Isothermal Amplification-Lateral Flow Dipstick Assay.
Echinococcosis poses a significant concern in the fields of public health and veterinary care as it can be transmitted between animals and humans. The primary endemic subtypes are cystic echinococcosis (CE) and alveolar echinococcosis (AE), which result from infestation by and , respectively. A prominent epidemic of echinococcosis greatly affects the Tibet Autonomous Region (TAR) in China. A new technique called the loop-mediated isothermal amplification-lateral flow dipstick (LAMP-LFD) test is introduced in this research to differentiate between and using their repetitive genetic sequences. The test is characterized by its portable nature, simple operation, quick result production, high sensitivity, and low susceptibility to aerosol contamination. The LAMP-LFD method demonstrated an exceptional minimal detection limit, reaching levels as low as approximately 1 fg/μL (femtogram per microliter) of genomic DNA. The assay's specificity was assessed, and no cross-reactivity was seen. A total of 982 dog fecal samples were collected from 54 counties in the TAR region between July 2021 and June 2022. The established method underwent validation using a commercially available ELISA kit. The agreement rate between the LAMP-LFD and ELISA methods was 97.25%, with a sensitivity of 96.05% and a specificity of 97.35%. The assay described in this study improves specificity by using a double-labeled probe, and it reduces the risk of false-positive results caused by aerosol contamination through the use of a sealed device. This makes it a suitable choice for quickly and accurately identifying the two main types of in field settings.
PubMed: 38922048
DOI: 10.3390/tropicalmed9060136 -
Scientific Reports Jul 2023Lyme disease, one of the most common tickborne diseases, has been rapidly spreading in parallel with the expansion of the range of its tick vector. Better tick...
Lyme disease, one of the most common tickborne diseases, has been rapidly spreading in parallel with the expansion of the range of its tick vector. Better tick surveillance efforts are needed to accurately estimate disease risk and to guide public health and clinical management. We have developed two multiplex loop-mediated isothermal amplification (LAMP) reactions coupled with oligonucleotide strand displacement (OSD) probes to identify the tick host, Ixodes scapularis, and the Lyme disease pathogen, Borrelia burgdorferi, they carry. In each multiplex LAMP-OSD assay the co-presence of two target sequences is computed at the DNA level by linking the two corresponding amplicons and detecting the co-product on colorimetric lateral flow dipsticks. In tests with synthetic DNA, the co-presence of as few as four copies of input DNA could be detected, without producing spurious signals. Most importantly, though, the LAMP-OSD assay is amenable to being carried out directly with macerated tick samples, without any sample preparation. In such field conditions, assays performed robustly and demonstrated 97-100% sensitivity and 100% specificity with both field-collected and lab-raised artificially infected ticks. Such easy-to-use, arthropod and pathogen-specific assays would be well suited to field and near patient use without relying on complex instrumentation or infrastructure.
Topics: Animals; Humans; Ixodes; Borrelia; Colorimetry; Lyme Disease; Borrelia burgdorferi; Nucleic Acids
PubMed: 37454160
DOI: 10.1038/s41598-023-38452-8 -
Neurourology and Urodynamics Feb 2024To confirm the improved performance of the micro-hole zone catheter (MHZC) compared to a conventional eyelet catheter (CEC) in male users of clean intermittent... (Randomized Controlled Trial)
Randomized Controlled Trial
Improved emptying performance with a new micro-hole zone catheter in adult male intermittent catheter users: A comparative multi-center randomized controlled cross-over study.
AIMS
To confirm the improved performance of the micro-hole zone catheter (MHZC) compared to a conventional eyelet catheter (CEC) in male users of clean intermittent catheterizations (CICs).
METHODS
Male self-catheterizing subjects, who used hydrophilic sleeved soft/flexible CIC as the only bladder emptying method, were enrolled into a multi-center, randomized, cross-over study performed across six European sites. Subjects tested the MHZC, featuring a drainage zone with 120 micro-holes and a CEC with two eyelets. The study consisted of four study visits (V0-V3), during which endpoints related to catheter performance (urinary flow-stops, bladder emptying, and intra-catheter pressure) were measured and two 4-week test periods at home (T1 and T2) where dipstick hematuria and user perception between catheters were evaluated.
RESULTS
Seventy-three male subjects with non-neurogenic and neurogenic bladder dysfunction (3:2) were enrolled. On average, catheterizations with the MHZC led to close to mean zero flow-stops compared to ≥1 flow-stops with the CEC, during both HCP- and self-led catheterizations (both p < 0.001). Residual urine at first flow-stop was significantly reduced for the MHZC compared to CEC (p = 0.001 and p = 0.004, for HCP- and self-led catheterizations, respectively). This was substantiated by a significantly smaller pressure peak at first flow-stop, a proxy for minimized mucosal suction (both HCP- and self-led catheterizations, p < 0.001). After home-use catheterizations, dipstick hematuria was comparable between catheters, whereas catheterizations were associated with significantly improved perception in favor of MHZC regarding bladder emptying, less blocking sensation, and improved hygienic catheterization compared to the CEC.
CONCLUSION
This study confirmed the evidence of improved bladder emptying with the MHZC compared to a CEC without the need to reposition the catheter. The MHZC therefore offers an enhanced benefit for the dependent CIC user securing complete bladder emptying in an uninterrupted free flow and reducing the need to reposition the catheter during emptying.
Topics: Adult; Humans; Male; Cross-Over Studies; Hematuria; Urinary Tract Infections; Intermittent Urethral Catheterization; Urinary Catheters; Urinary Catheterization; Urinary Bladder, Neurogenic
PubMed: 38196237
DOI: 10.1002/nau.25383