Medicine Nov 2023The Ozaki Procedure is an innovative surgical technique aiming of aortic valve neocuspidization using glutaraldehyde-treated autologous pericardium was first developed...
The Ozaki Procedure is an innovative surgical technique aiming of aortic valve neocuspidization using glutaraldehyde-treated autologous pericardium was first developed by Ozaki et al in 2007. With this newly developed technique, valve replacement was achieved without using prosthetic material due to both aortic stenosis and aortic insufficiency. Between December 2020 and December 2022, a total of 59 patients were operated on with the Ozaki Procedure due to aortic valve pathologies in our center. We evaluated the pre- and postoperative as well as the first-month data of a total of 44 patients with isolated the Ozaki Procedure and compared their echocardiographic changes. Patients with isolated aortic valve pathology were included in the study. Fifteen patients who underwent simultaneous coronary artery bypass surgery and Ozaki Procedure were excluded from the analysis. In the first month after the operation, n:2 (%4.5) patients died. When the preoperative and postoperative 1st month echocardiographic data of the remaining patients were compared, it was found that the decrease in mean gradient, max gradient and peak velocity values in the aortic valve was statistically significant. This is due to the fact that reaching neo-valves has very similar hemodynamics to the native aortic valve. Aortic valve neocuspidization by Ozaki Procedure may be a viable alternative to both surgical aortic valve replacement (AVR) and transcatheter aortic valve implantation. Its popularity and application is increasing all over the world. Short and mid-term results are available in the literature. The short and mid-term results are good, and the long-term results are hopeful.
Topics: Humans; Follow-Up Studies; Aortic Valve; Aortic Valve Insufficiency; Aortic Valve Stenosis; Heart Valve Prosthesis; Treatment Outcome
PubMed: 37960789
DOI: 10.1097/MD.0000000000035935 -
JACC. Cardiovascular Interventions Mar 2024
Topics: Humans; Aortic Valve; Aortic Valve Stenosis; Heart Valve Prosthesis; Prosthesis Design; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 38538171
DOI: 10.1016/j.jcin.2024.01.299 -
Journal of Nuclear Cardiology :... Dec 2023Our objective was to evaluate in patients with prosthetic valve endocarditis (PVE) treated conservatively, the prognostic value of white blood cell (WBC) signal...
BACKGROUND
Our objective was to evaluate in patients with prosthetic valve endocarditis (PVE) treated conservatively, the prognostic value of white blood cell (WBC) signal intensity on SPECT and to describe the evolution of the WBC signal under antibiotics.
METHODS
Patients with PVE treated conservatively and positive WBC-SPECT imaging were identified retrospectively. Signal intensity was classified as intense if equal to or higher, or mild if lower, than the liver signal. Clinical, biological, imaging and follow-up information were collected from medical files.
RESULTS
Among 47 patients, WBC signal was classified as intense in 10 patients and as mild, in 37. The incidence of the primary composite endpoint (death, late cardiac surgery, or relapse) was significantly higher in patients with intense vs. mild signal (90% vs. 11%). Twenty-five patients underwent a second WBC-SPECT imaging during follow-up. The prevalence of WBC signal decreased progressively from 89% between 3 and 6 weeks to 42% between 6 and 9 weeks and 8% more than 9 weeks after initiation of antibiotics.
CONCLUSIONS
In patients with PVE treated conservatively, intense WBC signal was associated with poor outcome. WBC-SPECT imaging appears as an interesting tool for risk stratification and to monitor locally the efficacy of antibiotic treatment.
Topics: Humans; Endocarditis, Bacterial; Follow-Up Studies; Retrospective Studies; Heart Valve Prosthesis; Endocarditis; Prognosis; Tomography, Emission-Computed, Single-Photon; Leukocytes; Anti-Bacterial Agents; Prosthesis-Related Infections
PubMed: 37430176
DOI: 10.1007/s12350-023-03335-y -
JACC. Cardiovascular Interventions Aug 2023
Topics: Humans; Treatment Outcome; Heart Valve Prosthesis Implantation; Pulmonary Valve; Heart Valve Prosthesis; Cardiac Catheterization
PubMed: 37204398
DOI: 10.1016/j.jcin.2023.04.007 -
The Journal of International Medical... Nov 2023is a Gram-negative bacillus typically associated with bacteremia in immunocompromised patients. Prosthetic valve endocarditis (PVE) is a serious complication of... (Review)
Review
is a Gram-negative bacillus typically associated with bacteremia in immunocompromised patients. Prosthetic valve endocarditis (PVE) is a serious complication of prosthetic valve surgery, with a high mortality rate if not treated promptly. We present a rare case of PVE caused by . A man in his mid-60s presented to the Emergency Department with a fever and showed elevated C-reactive protein concentrations. He had prosthetic mitral and aortic valve replacement surgery 15 years previously. Gram-negative rods were detected in a blood culture. These rods were identified as using matrix-assisted laser desorption ionization time-of-flight mass spectrometry and confirmed by 16S rRNA sequencing. The patient was treated with gentamicin and imipenem, and underwent valve replacement surgery. was isolated in a left atrial appendage swab obtained during the surgery. Follow-up blood cultures were negative after treatment. However, after a cardiac arrest event, the patient's general condition deteriorated, and he died. To the best of our knowledge, this is the first case of PVE caused by in Korea and the second fatality to date. This case highlights the importance of considering as a potential cause of PVE, even in patients without known risk factors.
Topics: Humans; Male; Aortic Valve; Campylobacter fetus; Endocarditis, Bacterial; Heart Valve Prosthesis; RNA, Ribosomal, 16S; Aged
PubMed: 37987669
DOI: 10.1177/03000605231213264 -
Small (Weinheim An Der Bergstrasse,... Jun 2024Valvular heart disease (VHD) has become a burden and a growing public health problem in humans, causing significant morbidity and mortality worldwide. An increasing... (Review)
Review
Valvular heart disease (VHD) has become a burden and a growing public health problem in humans, causing significant morbidity and mortality worldwide. An increasing number of patients with severe VHD need to undergo heart valve replacement surgery, and artificial heart valves are in high demand. However, allogeneic valves from donors are lacking and cannot meet clinical practice needs. A mechanical heart valve can activate the coagulation pathway after contact with blood after implantation in the cardiovascular system, leading to thrombosis. Therefore, bioprosthetic heart valves (BHVs) are still a promising way to solve this problem. However, there are still challenges in the use of BHVs. For example, their longevity is still unsatisfactory due to the defects, such as thrombosis, structural valve degeneration, calcification, insufficient re-endothelialization, and the inflammatory response. Therefore, strategies and methods are needed to effectively improve the biocompatibility and longevity of BHVs. This review describes the recent research advances in BHVs and strategies to improve their biocompatibility and longevity.
Topics: Heart Valve Prosthesis; Humans; Bioprosthesis; Animals; Biocompatible Materials; Heart Valves
PubMed: 38279610
DOI: 10.1002/smll.202309844 -
Heart Failure Reviews Jan 2024Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority... (Review)
Review
Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.
Topics: Humans; Male; Middle Aged; Female; Tricuspid Valve Insufficiency; Tricuspid Valve; Treatment Outcome; Retrospective Studies; Heart Valve Prosthesis; Heart Transplantation; Heart Valve Prosthesis Implantation
PubMed: 37851119
DOI: 10.1007/s10741-023-10364-9 -
European Journal of Cardio-thoracic... Aug 2023The Commando technique for reconstruction of the aortomitral intervalvular fibrous body is effective to facilitate double valve surgery in cases of endocarditis or...
OBJECTIVES
The Commando technique for reconstruction of the aortomitral intervalvular fibrous body is effective to facilitate double valve surgery in cases of endocarditis or infiltrative calcification. The length of patch utilized in reconstruction of the intervalvular fibrous body has an important relationship to the geometry of the mitral valve (MV) and aortic valve (AV) and may impact on potential future valve-in-valve (VIV) therapy. Here we report anatomic measurements after Commando reconstruction in a small group of patients and analyse the impact of reconstruction techniques on transcatheter VIV therapies.
METHODS
Seven patients from January 2018 to April 2022 who underwent double valve surgery with the Commando technique with postoperative computed tomography (CT) scans were identified. Computed tomographic reconstruction of the AV and MV was performed using 3mensio software and virtual transcatheter valve replacement was performed. Two of these patients who had preoperative imaging was analysed to assess the change in aortomitral geometry resulting from reconstruction.
RESULTS
Measurements for each patient post-reconstruction are given in the table. Aortomitral length was grossly inversely proportional to aortomitral angle (AMA). AMA and aortomitral curtain (AMC) length were significantly altered post-Commando in 2 analysed patients with pre- and postoperative computed tomography scan. Transcatheter AV and MV replacements were feasible in all patients post-Commando. The AMA was larger and more favorable for mitral VIV in patients in which the AMC was short.
CONCLUSIONS
AMC length, as determined by location of AV annular sutures, may be an important consideration in surgical decision-making for VIV after the Commando procedure.
Topics: Humans; Heart Valve Prosthesis Implantation; Aortic Valve; Mitral Valve; Heart Valve Prosthesis; Endocarditis; Treatment Outcome
PubMed: 37067485
DOI: 10.1093/ejcts/ezad155 -
Khirurgiia 2024The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of... (Review)
Review
The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of transcatheter pulmonary valve replacement. The authors also overviewed modern valves for transcatheter pulmonary artery replacement. Effectiveness of transcatheter pulmonary valve implantation has been substantiated. Various studies comparing the outcomes of different valve systems for endovascular implantation were analyzed. The authors concluded the prospects for transcatheter pulmonary valve implantation.
Topics: Humans; Cardiac Catheterization; Cardiac Surgical Procedures; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Prosthesis Design; Pulmonary Valve; Replantation; Treatment Outcome
PubMed: 38344958
DOI: 10.17116/hirurgia202402132 -
European Heart Journal. Cardiovascular... Nov 2023To determine the conditions under which early hypoattenuated leaflet thickening (HALT) after transcatheter aortic valve implantation (TAVI) becomes haemodynamically...
AIMS
To determine the conditions under which early hypoattenuated leaflet thickening (HALT) after transcatheter aortic valve implantation (TAVI) becomes haemodynamically relevant.
METHODS AND RESULTS
The study included 100 patients (age: 81.5 ± 5.5 years; female 63%), thereof 50 patients with HALT. After anonymization and randomization, blinded readers measured maximum thrombus thickness per prosthesis (MT_pr) and movement restriction (MR_pr) on electrocardiogram (ECG)-gated whole heart cycle computed tomography angiography. These measurements were compared with echocardiographic mean pressure gradient (mPG), its increase from baseline (ΔmPG), and Doppler velocity index (DVI). Haemodynamic valve deterioration (HVD) was defined as mPG > 20 mmHg. Age, body mass index, valve type, valve size, left ventricular ejection fraction, and atrial fibrillation were considered as influencing factors. Multiple regression analysis revealed that only valve size (P = 0.001) and MT_pr (P = 0.02) had a significant influence on mPG. In an interaction model, valve size moderated the effect of MT_pr on mPG significantly (P = 0.004). Sub-group analysis stratified by valve sizes showed a strong correlation between MT_pr and echocardiographic parameters for 23 mm valves (mPG: r = 0.57, ΔmPG: r = 0.68, DVI: r = 0.55, each with P < 0.001), but neither for 26 nor 29 mm valves (r < 0.2, P > 0.2 for all correlations). Six of seven prostheses with HVD had a 23 mm valve diameter, while one had 29 mm (P = 0.02).
CONCLUSION
Early HALT rarely causes significant mPG increase. Our study shows that valve size is a key factor influencing the haemodynamic impact of HALT. In small valve sizes, mPG is more likely to increase. Our study is the first to offer in vivo evidence supporting previous in vitro findings on this topic.
Topics: Aged; Aged, 80 and over; Female; Humans; Aortic Valve; Aortic Valve Stenosis; Heart Valve Prosthesis; Stroke Volume; Thrombosis; Transcatheter Aortic Valve Replacement; Treatment Outcome; Ventricular Function, Left; Male
PubMed: 37409579
DOI: 10.1093/ehjci/jead156