Khirurgiia 2024The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of... (Review)
Review
The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of transcatheter pulmonary valve replacement. The authors also overviewed modern valves for transcatheter pulmonary artery replacement. Effectiveness of transcatheter pulmonary valve implantation has been substantiated. Various studies comparing the outcomes of different valve systems for endovascular implantation were analyzed. The authors concluded the prospects for transcatheter pulmonary valve implantation.
Topics: Humans; Cardiac Catheterization; Cardiac Surgical Procedures; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Prosthesis Design; Pulmonary Valve; Replantation; Treatment Outcome
PubMed: 38344958
DOI: 10.17116/hirurgia202402132 -
The Thoracic and Cardiovascular Surgeon Apr 2024Bioprosthetic stentless aortic valves may degenerate over time and will require replacement. This study aimed to evaluate early- and mid-term outcomes after isolated... (Review)
Review
BACKGROUND
Bioprosthetic stentless aortic valves may degenerate over time and will require replacement. This study aimed to evaluate early- and mid-term outcomes after isolated surgical redo aortic valve replacement (redo-SAVR) and transcatheter valve-in-valve implantation (TAVI-VIV) for degenerated stentless Freestyle bioprostheses.
METHODS
We reviewed records of 56 patients at a single center. Overall, 37 patients (66.1%) received TAVI-VIV and 19 (33.9%) received redo-SAVR.
RESULTS
Thirty-day survival was similar in both groups (100%). One-year survival was comparable between groups (97.3% in TAVI-VIV and 100% in redo-SAVR, = 1.0). The difference in mid-term survival after adjusting for age and EuroScore II was not significant ( = 0.41). The incidence of pacemaker implantation after TAVI-VIV was higher than after redo-SAVR (19.4% vs. 0%, = 0.08).
CONCLUSION
The 30-day and 1-year survival rates after both procedures were outstanding, irrespective of baseline characteristics. Isolated redo-SAVR should be favored in young patients, as the pacemaker implantation rate is lower. TAVI-VIV for degenerated Freestyle prosthesis can be a method of choice in elderly patients and those with high operative risk.
Topics: Aged; Humans; Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Prosthesis Failure; Reoperation; Risk Factors; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 36858066
DOI: 10.1055/s-0043-1763286 -
Circulation Oct 2023Computed tomography (CT) is recommended for guiding transcatheter aortic valve replacement (TAVR). However, a sizable proportion of TAVR candidates have chronic kidney... (Randomized Controlled Trial)
Randomized Controlled Trial
BACKGROUND
Computed tomography (CT) is recommended for guiding transcatheter aortic valve replacement (TAVR). However, a sizable proportion of TAVR candidates have chronic kidney disease, in whom the use of iodinated contrast media is a limitation. Cardiac magnetic resonance imaging (CMR) is a promising alternative, but randomized data comparing the effectiveness of CMR-guided versus CT-guided TAVR are lacking.
METHODS
An investigator-initiated, prospective, randomized, open-label, noninferiority trial was conducted at 2 Austrian heart centers. Patients evaluated for TAVR according to the inclusion criteria (severe symptomatic aortic stenosis) and exclusion criteria (contraindication to CMR, CT, or TAVR, a life expectancy <1 year, or chronic kidney disease level 4 or 5) were randomized (1:1) to undergo CMR or CT guiding. The primary outcome was defined according to the Valve Academic Research Consortium-2 definition of implantation success at discharge, including absence of procedural mortality, correct positioning of a single prosthetic valve, and proper prosthetic valve performance. Noninferiority was assessed using a hybrid modified intention-to-treat/per-protocol approach on the basis of an absolute risk difference margin of 9%.
RESULTS
Between September 11, 2017, and December 16, 2022, 380 candidates for TAVR were randomized to CMR-guided (191 patients) or CT-guided (189 patients) TAVR planning. Of these, 138 patients (72.3%) in the CMR-guided group and 129 patients (68.3%) in the CT-guided group eventually underwent TAVR (modified intention-to-treat cohort). Of these 267, 19 patients had protocol deviations, resulting in a per-protocol cohort of 248 patients (121 CMR-guided, 127 CT-guided). In the modified intention-to-treat cohort, implantation success was achieved in 129 patients (93.5%) in the CMR group and in 117 patients (90.7%) in the CT group (between-group difference, 2.8% [90% CI, -2.7% to 8.2%]; <0.01 for noninferiority). In the per-protocol cohort (n=248), the between-group difference was 2.0% (90% CI, -3.8% to 7.8%; <0.01 for noninferiority).
CONCLUSIONS
CMR-guided TAVR was noninferior to CT-guided TAVR in terms of device implantation success. CMR can therefore be considered as an alternative for TAVR planning.
REGISTRATION
URL: https://www.
CLINICALTRIALS
gov; Unique identifier: NCT03831087.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Aortic Valve Stenosis; Prospective Studies; Treatment Outcome; Heart Valve Prosthesis Implantation; Tomography, X-Ray Computed; Heart Valve Prosthesis; Magnetic Resonance Imaging; Renal Insufficiency, Chronic; Risk Factors
PubMed: 37634187
DOI: 10.1161/CIRCULATIONAHA.123.066498 -
Seminars in Thoracic and Cardiovascular... 2024When the options of aortic valve repair or the Ross procedure are not feasible or have been exhausted, mechanical aortic valve replacement (AVR) may provide a reliable... (Review)
Review
When the options of aortic valve repair or the Ross procedure are not feasible or have been exhausted, mechanical aortic valve replacement (AVR) may provide a reliable and structurally durable alternative, but with the limitations of long-term anticoagulation, thrombosis risk and lack of valve growth potential. In this article, we review the longitudinal outcomes of mechanical AVR in children in our institution and compare them to those recently reported by others. From 1978 to 2020, 62 patients underwent mechanical AVR at a median age of 12.4 years (interquartile range (IQR): 8.6-16.8 years). The most common underlying diagnoses were: conotruncal anomalies (40%, 25/62), congenital aortic stenosis (16%, 10/62), rheumatic valve disease (16%, 10/62), connective tissue disease (8.1%, 5/62) and infective endocarditis (6.5%, 4/62). Thirty-two patients (52%, 32/62) had at least 1 prior aortic valve surgery prior to mechanical AVR. Early death was 3.2% (2/62). Median follow-up was 14.4 years (IQR: 8.4-28.2 years). Kaplan-Meier survival was 96.8%, 91.9%, 86.3%, and 81.9% at 1, 5, 10, and 20 years. On competing risk analysis, the proportion of patients alive without aortic valve reoperation at 1, 5, 10, and 20 years was 95.2%, 87.0%, 75.5% and 55.4%, respectively, while the proportion of patients that had aortic valve reoperation (with death as a competing event) at 1, 5, 10, and 20 years was 1.6%, 4.9%, 12.8%, and 28.5%, respectively. In conclusion, when the options of aortic valve repair or the Ross procedure are not feasible in children, mechanical AVR is an alternative, yet the long-term rates of mortality and need for aortic valve reoperation are of concern.
Topics: Child; Humans; Aortic Valve; Heart Valve Prosthesis Implantation; Treatment Outcome; Retrospective Studies; Heart Valve Diseases; Heart Valve Prosthesis; Reoperation
PubMed: 38522873
DOI: 10.1053/j.pcsu.2023.12.003 -
European Heart Journal Dec 2023
Topics: Humans; Tricuspid Valve; Heart Valve Prosthesis Implantation; Heart Valve Prosthesis; Cardiac Surgical Procedures
PubMed: 37936267
DOI: 10.1093/eurheartj/ehad622 -
European Journal of Cardio-thoracic... Oct 2023Existing aortic graft complicates the surgical management of prosthetic valve endocarditis (PVE); yet, its impact has not been well studied. We compared outcomes of...
OBJECTIVES
Existing aortic graft complicates the surgical management of prosthetic valve endocarditis (PVE); yet, its impact has not been well studied. We compared outcomes of patients with prior aortic valve replacement (AVR) versus aortic surgery plus AVR, who underwent reoperative aortic root replacement (ARR) for PVE of the aortic valve.
METHODS
All patients who underwent reoperative ARR for PVE between 2004 and 2021 from 2 aortic centres were included. Two groups were formed based on the presence/absence of aortic graft: prior aortic surgery (AO) and prior AVR (AV) alone. Inverse propensity treatment weighting matched the groups. The Kaplan-Meier method was used to analyse long-term survival, and Fine and Gray model was used to compare the cumulative incidence of reoperation.
RESULTS
A total of 130 patients were included (AO n = 59; AV n = 71). After matching, AO patients had increased stroke incidence (12.4% vs 0.9%) and renal failure requiring dialysis (11.5% vs 2.5%). In-hospital mortality was comparable (21.5% AO and 18.6% AV). Survival over 5 years was 68.9% (56.6-83.8%) in AO and 62.7% (48.1-81.7%) in AV (P = 0.70). The cumulative incidence of reoperation was similar [AO 6.3% (0.0-13.2%) vs AV 6.1% (0.0-15.1%), P = 0.69].
CONCLUSIONS
Reoperative ARRs for prosthetic valve/graft endocarditis are high-risk procedures. AO patients had higher incidence of postoperative morbidity versus AV patients. For all patients surviving operative intervention, survival and reoperation rates over 5 years were comparable between groups.
Topics: Humans; Aortic Valve; Endocarditis, Bacterial; Heart Valve Prosthesis; Reoperation; Heart Valve Prosthesis Implantation; Endocarditis; Treatment Outcome; Retrospective Studies
PubMed: 37494468
DOI: 10.1093/ejcts/ezad268 -
The Annals of Thoracic Surgery Oct 2023Biologic prostheses are being increasingly used for aortic and mitral valve replacement (AVR and MVR). This study evaluated the long-term durability of bioprosthetic...
BACKGROUND
Biologic prostheses are being increasingly used for aortic and mitral valve replacement (AVR and MVR). This study evaluated the long-term durability of bioprosthetic valves in the mitral and aortic positions, as no well-designed population-based studies have addressed this issue before.
METHODS
Using Taiwan's National Health Insurance Research Database, we compared biologic valve durability in the mitral and aortic positions in patients hospitalized between 2001 and 2017, with reoperation as the primary outcome. Both between-subject and within-subject designs were used, and the propensity score matching cohort (1:1 ratio) was created for the former.
RESULTS
We identified a total of 10,308 patients, 5462 of whom received AVR, 3901 received MVR, and 945 received double valve replacement. Both AVR and MVR cohorts had 2259 patients after matching. During a mean follow-up of 4.2 years (range, 1 day to 17.9 years), the reoperation rate in the MVR cohort (3.5%) was higher than that in the AVR cohort (2.6%) (hazard ratio 1.41; 95% CI, 1.01-1.98). A higher risk of all-cause death was observed in the MVR cohort (36.5%) than in the AVR cohort (32.6%) (hazard ratio 1.21; 95% CI, 1.10-1.34). Among patients receiving double valve replacement with the same prosthesis type, valves implanted in the aortic position were considerably less likely to require reimplantation.
CONCLUSIONS
Bioprosthetic valve placement in the aortic position is associated with superior outcomes in terms of durability, long-term mortality, and perioperative morbidity. Developing novel interventions and enhancing valve durability would expand bioprosthesis use for valve replacement.
Topics: Humans; Cohort Studies; Mitral Valve; Aortic Valve; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Bioprosthesis; Reoperation; Biological Products; Follow-Up Studies
PubMed: 37356516
DOI: 10.1016/j.athoracsur.2023.05.038 -
The American Journal of Cardiology Feb 2024Valve-in-valve (ViV) transcatheter aortic valve implantation (ViV-TAVI) in patients with failed bioprostheses arose as an alternative to redo surgical aortic valve... (Meta-Analysis)
Meta-Analysis
Valve-in-valve (ViV) transcatheter aortic valve implantation (ViV-TAVI) in patients with failed bioprostheses arose as an alternative to redo surgical aortic valve replacement (SAVR). To evaluate all-cause mortality in ViV-TAVI versus redo-SAVR, we performed a study-level meta-analysis of reconstructed time-to-event data from Kaplan-Meier curves of nonrandomized studies published by August 2023. A total of 16 studies met our eligibility criteria, with a total of 4,373 patients (2,204 patients underwent ViV-TAVI and 2,169 patients underwent redo-SAVR). Pooling all the studies, ViV-TAVI showed a lower risk of all-cause mortality in the first 6 months (hazard ratio [HR] 0.58, 95% confidence interval [CI] 0.46 to 0.73, p <0.001), with an HR reversal after this time point favoring redo-SAVR (HR 1.92, 95% CI 1.58 to 2.33, p <0.001). Pooling only the matched populations (which represented 64.6% of the overall population), ViV-TAVI showed a lower risk of all-cause mortality in the first 6 months (HR 0.56, 95% CI 0.43 to 0.73, p <0.001], with a reversal after 6 months favoring redo-SAVR (HR 1.55, 95% CI 1.25 to 1.93, p <0.001). The meta-regression analyses revealed a modulating effect of the following covariates: age, coronary artery disease, history of coronary artery bypass graft surgery, and implanted valves <25 mm. In conclusion, ViV-TAVI is associated with better survival immediately after the procedure than redo-SAVR; however, this primary advantage reverses over time, and redo-SAVR seems to offer better survival at a later stage. Because these results are pooled data from observational studies, they should be interpreted with caution, and randomized controlled trials are warranted.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Heart Valve Prosthesis Implantation; Heart Valve Prosthesis; Aortic Valve Stenosis; Bioprosthesis; Treatment Outcome; Risk Factors
PubMed: 38070591
DOI: 10.1016/j.amjcard.2023.11.054 -
International Journal of Cardiology May 2024
Topics: Humans; Aortic Valve; Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis; Treatment Outcome; Prosthesis Design; Aortic Valve Stenosis
PubMed: 38373684
DOI: 10.1016/j.ijcard.2024.131883 -
The American Journal of Cardiology Sep 2023
Topics: Humans; Transcatheter Aortic Valve Replacement; Cardiac Conduction System Disease; Aortic Valve; Treatment Outcome; Aortic Valve Stenosis; Heart Valve Prosthesis; Pacemaker, Artificial; Risk Factors
PubMed: 37385924
DOI: 10.1016/j.amjcard.2023.06.020