Journal of Neuroengineering and... Nov 2023The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced... (Review)
Review
BACKGROUND
The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure.
METHODS
Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices.
RESULTS
50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (nā=ā16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket.
DISCUSSION
There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.
Topics: Humans; Prosthesis Design; Research Design; Amputation Stumps; Artificial Limbs; Extremities
PubMed: 37926807
DOI: 10.1186/s12984-023-01270-0 -
The Pan African Medical Journal 2024During the 1970s, scientists first used botulinum toxin to treat strabismus. While testing on monkeys, they noticed that the toxin could also reduce wrinkles in the... (Review)
Review
During the 1970s, scientists first used botulinum toxin to treat strabismus. While testing on monkeys, they noticed that the toxin could also reduce wrinkles in the glabella area. This led to its widespread use in both medical and cosmetic fields. The objective of the study was to evaluate the potential use of Botox in managing post-operative contracture after below-knee amputation. We conducted a systematic review In Pubmed, Cochrane Library, Embase, and Google Scholar using the MESH terms Botox, botulinum toxin, post-operative contracture, amputation, and below knee amputation. Our goal was to evaluate the potential use of Botox to manage post-operative contracture in patients who have undergone below-knee amputation. Our findings show evidence in the literature that Botox can effectively manage stump hyperhidrosis, phantom pain, and jumping stump, but no clinical trial has been found that discusses the use of Botox for post-operative contracture. Botox has been used in different ways to manage spasticity. Further studies and clinical trials are needed to support the use of Botox to manage this complication.
Topics: Humans; Botulinum Toxins, Type A; Amputation, Surgical; Contracture; Amputation Stumps; Muscle Spasticity; Joint Dislocations; Neuromuscular Agents
PubMed: 38558551
DOI: 10.11604/pamj.2024.47.26.42249 -
Cureus Mar 2024Lower limb amputation is a common orthopedic surgery in the United States and can be performed either above or below the knee. Prosthetics are typically externally... (Review)
Review
Lower limb amputation is a common orthopedic surgery in the United States and can be performed either above or below the knee. Prosthetics are typically externally fitted to the patient's residual stump; however, osseointegrated implants offer a potential alternative to this process. Transcutaneous limb osseointegration involves the intramedullary anchoring of an implant that can later attach to a prosthetic via a stoma in the residual limb. There are proposed benefits to this, including decreased skin and soft tissue complications as well as an increased sense of stability. As this is a relatively new procedure, the complications and efficacy are not well supported by the literature at this time. The primary aim of this analysis was to synthesize the currently available data on transfemoral and transtibial osseointegration in order to improve our understanding of the potential complications of the procedure. A literature search was performed in the following databases: Biomedical Reference Collection, CINAHL, Cochrane Library, and PubMed/MEDLINE. Articles were screened by three independent reviewers for studies written or available in English, study design, and study outcomes, including complications. No filter was applied for publication date, publication national origin, or sample size. A total of 20 articles were selected for the final qualitative analysis. This review demonstrates an overall low or non-inferior rate of both minor and severe complications in transtibial and transfemoral osseointegration. This procedure should be considered as an option during preoperative planning in the context of above-the-knee and below-the-knee amputations. However, continued studies with larger sample sizes and extended postoperative follow-up are necessary for a greater strength of recommendation.
PubMed: 38681289
DOI: 10.7759/cureus.57045