Cureus Aug 2023Sudden cardiac death (SCD) is a condition that accounts for a high percentage of cardiovascular fatalities, with ventricular tachyarrhythmias being the most common... (Review)
Review
Sudden cardiac death (SCD) is a condition that accounts for a high percentage of cardiovascular fatalities, with ventricular tachyarrhythmias being the most common cause. There are signs and symptoms of SCD that occur spontaneously without any warning and are deadly. Despite preventative efforts focusing on the use of subcutaneous implanted cardioverter defibrillators (S-ICD) in the highest-risk population categories, a high number of SCDs occur in the normal population and in people who do not have a documented cardiac condition. Therefore, primary prevention for SCD should be a more viable strategy for the general population, considering measures in the form of preventive medicine such as knowing more about any genetic predisposition, family history of any fatal arrhythmia, continuous surveillance after any syncope with unknown causes, etc. However, little data about SCD risk factors are known in comparison with other well-known diseases like ischemic heart disease and stroke. In search of medical databases for relevant medical literature, we looked at PubMed/Medline, the Cochrane Library, and Google Scholar. Thirteen publications were discovered after the papers were located, assessed, and qualifying criteria were applied. The finished articles were done to give an overview of SCD. Some others have shown that the major predisposition for SCD is related to the male gender, which increases the incidence if they have a family history of SCD. We described the importance of obstructive sleep apnea (OSA) as a comorbid condition. Patients with S-ICD and young athletes with a history of ventricular arrhythmia showed us that the predisposition for SCD can be higher than in the normal population. Based on the above, we concluded that more study is required to establish the most important approach for each of the risk factors mentioned in this systematic review in order to apply them in daily practice and have more knowledge about how to apply preventive and therapeutic medicine to the population at risk and the ones that already develop the disease.
PubMed: 37664320
DOI: 10.7759/cureus.42859 -
Journal of the Saudi Heart Association 2023Cardiac implantable electronic devices (CIED) include permanent pacemakers (PPMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy... (Review)
Review
INTRODUCTION
Cardiac implantable electronic devices (CIED) include permanent pacemakers (PPMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices. They treat several cardiac issues and are dependent on batteries; however, similar to any medical equipment, they can fail. The prevalence and risk factors for CIED malfunction must be understood for earlier detection and better patient outcomes.
MATERIAL AND METHODS
A comprehensive search was conducted through electronic bibliographic sources (PubMed and Cochrane) until January 2023 in order to identify reviews, cohort studies and case reports pertaining to CIED. The primary outcome is the probability of CIED malfunction. The secondary outcome concerned significant risk factors. Two authors independently extracted articles by utilizing pre-established data fields. Using a random-effects model, the aggregated prevalence and 95 % confidence intervals (CIs) were computed.
RESULTS
The meta-analysis comprised eight review articles, twenty-two retrospective studies, and thirty-seven case reports from the systematic review. The eight review articles contained a CIED malfunction of 4.03 % (random-effects model). The pooled prevalence of CIED malfunction in the meta-analysis of 22 retrospective studies was 0.41 percent (using a fixed-effects model) and 8.01 percent (using a random-effects model). Moreover, age, pre-existing cardiac conditions, CIED type, lead placement, and medical device interactions all contributed to an increase in the heterogeneity (I2 = 98.90 %) of the risk of CIED malfunction.
CONCLUSION
CIED malfunction is common and more likely to occur in elderly individuals and in certain types of CIED. Clinicians should focus on risk factors and closely monitor the patients with higher probability for CIED malfunction with short intervals.
PubMed: 38179411
DOI: 10.37616/2212-5043.1359 -
Global Heart 2023Bystander cardiopulmonary resuscitation (CPR) and using an automated external defibrillator (AED) can improve out-of-hospital cardiac arrest survival. However, bystander...
Factors and Barriers on Cardiopulmonary Resuscitation and Automated External Defibrillator Willingness to Use among the Community: A 2016-2021 Systematic Review and Data Synthesis.
BACKGROUND
Bystander cardiopulmonary resuscitation (CPR) and using an automated external defibrillator (AED) can improve out-of-hospital cardiac arrest survival. However, bystander CPR and AED rates remained consistently low. The goal of this systematic review was to assess factors influencing community willingness to perform CPR and use an AED for out-of-hospital cardiac arrest survival (OHCA) victims, as well as its barriers.
METHODS
The review processes (PROSPERO: CRD42021257851) were conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) review protocol; formulation of review questions; systematic search strategy based on identification, screening, and eligibility using established databases including Scopus, Web of Science, and Medline Complete via EBSCOhost; quality appraisal; and data extraction and analysis. There is identification of full-text journal articles that were published between 2016 and 2021 and written in English.
RESULTS
Of the final 13 articles, there are six identified factors associated with willingness to perform CPR and use an AED, including socio-demographics, training, attitudes, perceived norms, self-efficacy, and legal obligation. Younger age, men, higher level of education, employed, married, having trained in CPR and AED in the previous 5 years, having received CPR education on four or more occasions, having a positive attitude and perception toward CPR and AED, having confidence to perform CPR and to apply an AED, and legal liability protection under emergency medical service law were reasons why one would be more likely to indicate a willingness to perform CPR and use an AED. The most reported barriers were fear of litigation and injuring a victim.
CONCLUSIONS
There is a need to empower all the contributing factors and reduce the barrier by emphasizing the importance of CPR and AEDs. The role played by all stakeholders should be strengthened to ensure the success of intervention programs, and indirectly, that can reduce morbidity and mortality among the community from OHCA.
Topics: Child, Preschool; Humans; Male; Cardiopulmonary Resuscitation; Databases, Factual; Educational Status; Emergency Medical Services; Out-of-Hospital Cardiac Arrest
PubMed: 37649652
DOI: 10.5334/gh.1255 -
Cureus Nov 2023Implantable cardioverter defibrillators (ICD) have been recommended as an effective therapy in treating sudden cardiac deaths. This study evaluates the safety and... (Review)
Review
Implantable cardioverter defibrillators (ICD) have been recommended as an effective therapy in treating sudden cardiac deaths. This study evaluates the safety and efficacies of ICDs in detecting arrhythmias. Different ICDs, such as the transvenous cardioverter defibrillator (TV-ICD) and the subcutaneous implantable cardioverter defibrillator (S-ICD), are used. This systematic review identified Embase, PubMed, Medical Literature Analysis and Retrieval System Online (MEDLINE), and Web of Science as the primary electronic databases for research. Supplementation of the available articles for the review was done using Google Scholar. The population, exposure, control, outcome, and studies (PECOS) criteria were used in this study. The quality of the included studies was assessed using the Critical Appraisal Skills Program (CASP) standard checklist. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used in this systematic review. Two researchers conducted the extraction of data. A pre-designed Excel worksheet (Microsoft, Redmond, Washington) was used in the recording of extracted data. Eight studies were identified for use in this systematic review. Safety of the ICDs was observed with the minimum number of reported inappropriate shocks. Studies conducted identified that women had a lower number of incidences when a long detection setting by sex was conducted. Strategic programming of ICDs was noted as effective in lowering the levels of mortality. Studies claimed that the reduction of inappropriate shocks were important in the reduction of myocardial damage, which resulted in the mortality rate among the patients decreasing. Having high cutoff rates and long intervals for detection in ICD programming was noted to help in reducing ICD therapy intervention among patients. Differences among the male and female populations were inconsequential in the efficacy and safety of ICDs. Their effectiveness in sensitivity, pacing success, and defibrillation success were high and very significant. ICDs were safe in their use in the detection of arrhythmias.
PubMed: 38074043
DOI: 10.7759/cureus.48471 -
Current Heart Failure Reports Oct 2023This systematic review aims to summarise clustering studies in heart failure (HF) and guide future clinical trial design and implementation in routine clinical practice. (Review)
Review
REVIEW PURPOSE
This systematic review aims to summarise clustering studies in heart failure (HF) and guide future clinical trial design and implementation in routine clinical practice.
FINDINGS
34 studies were identified (n = 19 in HF with preserved ejection fraction (HFpEF)). There was significant heterogeneity invariables and techniques used. However, 149/165 described clusters could be assigned to one of nine phenotypes: 1) young, low comorbidity burden; 2) metabolic; 3) cardio-renal; 4) atrial fibrillation (AF); 5) elderly female AF; 6) hypertensive-comorbidity; 7) ischaemic-male; 8) valvular disease; and 9) devices. There was room for improvement on important methodological topics for all clustering studies such as external validation and transparency of the modelling process. The large overlap between the phenotypes of the clustering studies shows that clustering is a robust approach for discovering clinically distinct phenotypes. However, future studies should invest in a phenotype model that can be implemented in routine clinical practice and future clinical trial design. HF = heart failure, EF = ejection fraction, HFpEF = heart failure with preserved ejection fraction, HFrEF = heart failure with reduced ejection fraction, CKD = chronic kidney disease, AF = atrial fibrillation, IHD = ischaemic heart disease, CAD = coronary artery disease, ICD = implantable cardioverter-defibrillator, CRT = cardiac resynchronization therapy, NT-proBNP = N-terminal pro b-type natriuretic peptide, BMI = Body Mass Index, COPD = Chronic obstructive pulmonary disease.
PubMed: 37477803
DOI: 10.1007/s11897-023-00615-z -
Annals of Noninvasive Electrocardiology... Sep 2023Double sequential external defibrillation (DSED) and vector-change defibrillation (VCD) have been suggested to enhance clinical outcomes for patients with ventricular... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND AND OBJECTIVE
Double sequential external defibrillation (DSED) and vector-change defibrillation (VCD) have been suggested to enhance clinical outcomes for patients with ventricular fibrillation (VF) refractory of standard defibrillation (SD). Therefore, this network meta-analysis aims to evaluate the comparative efficacy of DSED, VCD, and SD for refractory VF.
METHODS
A systematic review and network meta-analysis synthesizing randomized controlled trials (RCTs) and comparative observational studies retrieved from PubMed, EMBASE, WOS, SCOPUS, and Cochrane through November 15th, 2022. R software netmeta and netrank package (R version 4.2.0) and meta-insight software were used to pool dichotomous outcomes using odds ratio (OR) presented with the corresponding confidence interval (CI). Our protocol was prospectively published in PROSPERO with ID: CRD42022378533.
RESULTS
We included seven studies with a total of 1632 participants. DSED was similar to SD in survival to hospital discharge (OR: 1.14 with 95% CI [0.55, 2.83]), favorable neurological outcome (modified Rankin scale ≤2 or cerebral performance category ≤2) (OR: 1.35 with 95% CI [0.46, 3.99]), and return of spontaneous circulation (ROSC) (OR: 0.81 with 95% CI [0.43; 1.5]). In addition, VCD was similar to SD in survival to hospital discharge (OR: 1.12 with 95% CI [0.27, 4.57]), favorable neurological outcome (OR: 1.01 with 95% CI [0.18, 5.75]), and ROSC (OR: 0.88 with 95% CI [0.24; 3.15]).
CONCLUSION
Double sequential external defibrillation and VCD were not associated with enhanced outcomes in patients with refractory VF out-of-hospital cardiac arrest, compared to SD. However, the current evidence is still inconclusive, warranting further large-scale RCTs.
Topics: Humans; Electric Countershock; Ventricular Fibrillation; Out-of-Hospital Cardiac Arrest; Network Meta-Analysis; Electrocardiography; Cardiopulmonary Resuscitation
PubMed: 37482919
DOI: 10.1111/anec.13075 -
Europace : European Pacing,... Nov 2023Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two... (Meta-Analysis)
Meta-Analysis
AIMS
Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis.
METHODS AND RESULTS
We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01).
CONCLUSION
Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.
Topics: Humans; Defibrillators, Implantable; Vena Cava, Superior; Device Removal; Lasers; Cardiac Catheterization; Pacemaker, Artificial; Treatment Outcome; Retrospective Studies
PubMed: 37882609
DOI: 10.1093/europace/euad316 -
Journal of Medical Systems May 2024Virtual reality (VR) is becoming increasingly popular to train health-care professionals (HCPs) to acquire and/or maintain cardiopulmonary resuscitation (CPR) basic or... (Review)
Review
INTRODUCTION
Virtual reality (VR) is becoming increasingly popular to train health-care professionals (HCPs) to acquire and/or maintain cardiopulmonary resuscitation (CPR) basic or advanced skills.
AIM
To understand whether VR in CPR training or retraining courses can have benefits for patients (neonatal, pediatric, and adult), HCPs and health-care organizations as compared to traditional CPR training.
METHODS
A systematic review (PROSPERO: CRD42023431768) following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. In June 2023, the PubMed, Cochrane Library, Scopus and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases were searched and included studies evaluated in their methodological quality with Joanna Briggs Institute checklists. Data were narratively summarized.
RESULTS
Fifteen studies published between 2013 and 2023 with overall fair quality were included. No studies investigated patients' outcomes. At the HCP level, the virtual learning environment was perceived to be engaging, realistic and facilitated the memorization of the procedures; however, limited decision-making, team building, psychological pressure and frenetic environment were underlined as disadvantages. Moreover, a general improvement in performance was reported in the use of the defibrillator and carrying out the chest compressions. At the organizational level, one study performed a cost/benefit evaluation in favor of VR as compared to traditional CPR training.
CONCLUSIONS
The use of VR for CPR training and retraining is in an early stage of development. Some benefits at the HCP level are promising. However, more research is needed with standardized approaches to ensure a progressive accumulation of the evidence and inform decisions regarding the best training methodology in this field.
Topics: Cardiopulmonary Resuscitation; Humans; Virtual Reality; Health Personnel
PubMed: 38748244
DOI: 10.1007/s10916-024-02063-1 -
Cureus Oct 2023Out-of-hospital cardiac arrest (OHCA) remains a significant cause of death. The chance of survival significantly increases when immediate defibrillation with an... (Review)
Review
Out-of-hospital cardiac arrest (OHCA) remains a significant cause of death. The chance of survival significantly increases when immediate defibrillation with an on-site automated external defibrillator (AED) is available. Our aim is to systematically evaluate the impact of public access defibrillators (PAD) on the outcomes of outpatient cardiac arrest. We conducted a systematic review of the data from global studies on the role of bystander and emergency medical service (EMS) interventions, primarily focusing on the usage of AEDs, during OHCA events. The results highlight the critical significance of PADs in improving survival outcomes in OHCA settings. The majority of OHCA incidents occurred in private residences, but public spaces such as schools and airports had better outcomes, likely due to AED accessibility and trained individuals. Placing AEDs in public areas, especially high-risk zones, can boost survival chances. Timely defibrillation, particularly by bystanders, correlated with better survival and neurological conditions. The review emphasizes the importance of widespread cardiopulmonary resuscitation (CPR) and AED training, strategic AED placement, and continuous monitoring of interventions and outcomes to enhance survival rates and neurological recovery after OHCAs. This systematic review showed that bystander interventions, including CPR and AED usage, significantly increased the survival rate. Overall, immediate response and accessibility to AEDs in public areas can significantly improve outcomes in OHCA events.
PubMed: 38021997
DOI: 10.7759/cureus.47721 -
Cureus Sep 2023An increase in cardiovascular implantable electronic devices (CIEDs) and undoubtedly the complications brought on by these devices coincide with an increase in... (Review)
Review
An increase in cardiovascular implantable electronic devices (CIEDs) and undoubtedly the complications brought on by these devices coincide with an increase in cardiovascular disorders, particularly heart rhythm abnormalities. The safest procedure to extract these devices is transvenous lead extraction (TLE). Thus, this systematic review aimed to summarize the possibility of success rates and the common complications that could arise during the surgery. Full-text publications in PubMed, MEDLINE, PubMed Central (PMC), and ScienceDirect were used in this study, which was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Seventeen studies were reviewed for this systematic review after being screened by title, abstract, full-text availability, and quality appraisal assessment. Heart and vascular tears, along with tricuspid regurgitation (TR), are common adverse events. Pulmonary embolism, hemothorax, hemopericardium, and ghost appearance in echo are less common consequences. In addition, the longer the dwelling time of the leads, the greater the chance of infection due to an increase in lead adhesions and fibrous tissue that has made the procedure unsafe as time passes. However, we concluded that TLE is a successful method across all age groups with an excellent probability of clinical and procedural success in a majority of studies.
PubMed: 37829955
DOI: 10.7759/cureus.45048