-
Cureus Sep 2023An increase in cardiovascular implantable electronic devices (CIEDs) and undoubtedly the complications brought on by these devices coincide with an increase in... (Review)
Review
An increase in cardiovascular implantable electronic devices (CIEDs) and undoubtedly the complications brought on by these devices coincide with an increase in cardiovascular disorders, particularly heart rhythm abnormalities. The safest procedure to extract these devices is transvenous lead extraction (TLE). Thus, this systematic review aimed to summarize the possibility of success rates and the common complications that could arise during the surgery. Full-text publications in PubMed, MEDLINE, PubMed Central (PMC), and ScienceDirect were used in this study, which was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Seventeen studies were reviewed for this systematic review after being screened by title, abstract, full-text availability, and quality appraisal assessment. Heart and vascular tears, along with tricuspid regurgitation (TR), are common adverse events. Pulmonary embolism, hemothorax, hemopericardium, and ghost appearance in echo are less common consequences. In addition, the longer the dwelling time of the leads, the greater the chance of infection due to an increase in lead adhesions and fibrous tissue that has made the procedure unsafe as time passes. However, we concluded that TLE is a successful method across all age groups with an excellent probability of clinical and procedural success in a majority of studies.
PubMed: 37829955
DOI: 10.7759/cureus.45048 -
Resuscitation Plus Sep 2023Worldwide, bystander CPR rates are low; one effective way to increase these rates is to train schoolchildren; however, the most effective way to train them is currently... (Review)
Review
BACKGROUND
Worldwide, bystander CPR rates are low; one effective way to increase these rates is to train schoolchildren; however, the most effective way to train them is currently unknown.
METHODS
This systematic review and meta-analysis of randomized controlled trials (RCTs) and observational studies, evaluated whether CPR training for schoolchildren, using innovative teaching modalities (nonpractical, self, or peer-training) versus standard instructor-led training, resulted in higher quality CPR, self-confidence and short-term (≤3 months post-training) or long-term (>3 months post-training) retention of CPR skills.
RESULTS
From 9793 citations, 96 studies published between 1975 and 2022 (44 RCTs and 52 before/after studies) were included. There were 43,754 students, average age of 11.5 ± 0.9 (range 5.9-17.6) and 49.2% male. Only 13 RCTs compared practical vs. nonpractical training (n = 5), self- vs. instructor-led training (n = 7) or peer- vs. instructor-led training (n = 5). The observed statistically significant differences in mean depth and rate of compressions between children with hands-on practical training and those without were not clinically relevant. Regardless of training modality, compression depth was consistently suboptimal. No differences were observed in CPR skills immediately or ≤ 3 months post-training, between children who were self- or peer-trained vs. instructor-led. Due to lack of data, we were unable to evaluate the impact of these novel training modalities on student self-confidence.
CONCLUSION
Although innovative training modalities are equally effective to instructor-led training when teaching schoolchildren CPR, compression depth was frequently suboptimal. Recommendations on standardized training and evaluation methods are necessary to understand the best ways to train children.
PubMed: 37638097
DOI: 10.1016/j.resplu.2023.100439 -
Scientific Reports Aug 2023Risk stratification based mainly on the impairment of left ventricular ejection fraction has limited performance in patients with nonischemic dilated cardiomyopathy... (Meta-Analysis)
Meta-Analysis
Risk stratification based mainly on the impairment of left ventricular ejection fraction has limited performance in patients with nonischemic dilated cardiomyopathy (NIDCM). Evidence is rapidly growing for the impact of myocardial scar identified by late gadolinium enhancement (LGE) cardiac magnetic resonance imaging (CMR) on cardiovascular events. We aim to assess the prognostic value of LGE on long-term arrhythmic and mortality outcomes in patients with NIDCM. PubMed, Scopus, and Cochrane databases were searched from inception to January 21, 2022. Studies that included disease-specific subpopulations of NIDCM were excluded. Data were independently extracted and combined via random-effects meta-analysis using a generic inverse-variance strategy. Data from 60 studies comprising 15,217 patients were analyzed with a 3-year median follow-up. The presence of LGE was associated with major ventricular arrhythmic events (pooled OR: 3.99; 95% CI 3.08, 5.16), all-cause mortality (pooled OR: 2.14; 95% CI 1.81, 2.52), cardiovascular mortality (pooled OR 2.83; 95% CI 2.23, 3.60), and heart failure hospitalization (pooled OR: 2.53; 95% CI 1.78, 3.59). Real-world evidence suggests that the presence of LGE on CMR was a strong predictor of adverse long-term outcomes in patients with NIDCM. Scar assessment should be incorporated as a primary determinant in the patient selection criteria for primary prophylactic implantable cardioverter-defibrillator placement.
Topics: Humans; Cardiomyopathy, Dilated; Gadolinium; Cicatrix; Contrast Media; Stroke Volume; Ventricular Function, Left; Magnetic Resonance Imaging
PubMed: 37612359
DOI: 10.1038/s41598-023-41087-4 -
Heart Failure Reviews Jul 2023Risk stratification for sudden cardiac death in dilated cardiomyopathy is a field of constant debate, and the currently proposed criteria have been widely questioned due... (Review)
Review
Risk stratification for sudden cardiac death in dilated cardiomyopathy is a field of constant debate, and the currently proposed criteria have been widely questioned due to their low positive and negative predictive value. In this study, we conducted a systematic review of the literature utilizing the PubMed and Cochrane library platforms, in order to gain insight about dilated cardiomyopathy and its arrhythmic risk stratification utilizing noninvasive risk markers derived mainly from 24 h electrocardiographic monitoring. The obtained articles were reviewed in order to register the various electrocardiographic noninvasive risk factors used, their prevalence, and their prognostic significance in dilated cardiomyopathy. Premature ventricular complexes, nonsustained ventricular tachycardia, late potentials on Signal averaged electrocardiography, T wave alternans, heart rate variability and deceleration capacity of the heart rate, all have both some positive and negative predictive value to identify patients in higher likelihood for ventricular arrhythmias and sudden cardiac death. Corrected QT, QT dispersion, and turbulence slope-turbulence onset of heart rate have yet to establish a predictive correlation in the literature. Although ambulatory electrocardiographic monitoring is frequently used in clinical practice in DCM patients, no single risk marker can be used for the selection of patients at high-risk for malignant ventricular arrhythmic events and sudden cardiac death who could benefit from the implantation of a defibrillator. More studies are needed in order to establish a risk score or a combination of risk factors with the purpose of selecting high-risk patients for ICD implantation in the context of primary prevention.
Topics: Humans; Electrocardiography, Ambulatory; Cardiomyopathy, Dilated; Electrocardiography; Death, Sudden, Cardiac; Arrhythmias, Cardiac; Risk Factors; Prognosis
PubMed: 36872393
DOI: 10.1007/s10741-023-10300-x -
Europace : European Pacing,... Jun 2024Persistent reluctance to perform magnetic resonance imaging (MRI) in patients with abandoned and/or epicardial leads of cardiac implantable electronic devices is related... (Meta-Analysis)
Meta-Analysis
AIMS
Persistent reluctance to perform magnetic resonance imaging (MRI) in patients with abandoned and/or epicardial leads of cardiac implantable electronic devices is related to in vitro studies reporting tip heating. While there is a plethora of data on the safety of MRI in conditional and non-conditional implantable devices, there is a clear lack of safety data in patients with abandoned and/or epicardial leads.
METHODS AND RESULTS
Relevant literature was identified in Medline and CINAHL using the key terms 'magnetic resonance imaging' AND 'abandoned leads' OR 'epicardial leads'. Secondary literature and cross-references were supplemented. For reporting guidance, the Preferred Reporting Items for Systematic reviews and Meta-Analyses 2020 was used. International Prospective Register of Systematic Reviews (PROSPERO) registration number 465530. Twenty-one publications with a total of 656 patients with 854 abandoned and/or epicardial leads and 929 MRI scans of different anatomical regions were included. No scan-related major adverse cardiac event was documented, although the possibility of under-reporting of critical events in the literature should be considered. Furthermore, no severe device dysfunction or severe arrhythmia was reported. Mainly transient lead parameter changes were observed in 2.8% in the subgroup of patients with functional epicardial leads. As a possible correlate of myocardial affection, subjective sensations occurred mainly in the subgroup with abandoned epicardial leads (4.0%), but no change in myocardial biomarkers was observed.
CONCLUSION
Existing publications did not report any relevant adverse events for MRI in patients with abandoned and/or epicardial leads if performed according to strict safety guidelines. However, a more rigorous risk-benefit calculation should be made for patients with epicardial leads.
Topics: Humans; Defibrillators, Implantable; Magnetic Resonance Imaging; Pacemaker, Artificial; Patient Safety
PubMed: 38918179
DOI: 10.1093/europace/euae165 -
International Journal of Cardiology.... Dec 2023
Authors' reply to Critical appraisal of "Goetz G, Wernly B, Wild C (2023) Wearable cardioverter defibrillator for preventing sudden cardiac death in patients at risk: An updated systematic review of comparative effectiveness and safety. IJC Heart & Vasculature 45 (2023) 101189" by M. Nürnberg, F....
PubMed: 38059169
DOI: 10.1016/j.ijcha.2023.101299 -
International Journal of Cardiology.... Oct 2023
PubMed: 37680548
DOI: 10.1016/j.ijcha.2023.101258 -
International Journal of Cardiology.... Jun 2024Recent studies investigating the effects of fish oil on shocks administered by ICDs in patients with ventricular tachycardias produced inconclusive results. This... (Review)
Review
BACKGROUND
Recent studies investigating the effects of fish oil on shocks administered by ICDs in patients with ventricular tachycardias produced inconclusive results. This systematic review aims to evaluate the effectiveness of omega-3 polyunsaturated fatty acids in lowering the risk of life-threatening VTs among individuals with implantable cardioverter-defibrillators.
METHODS
We searched five databases, including Central, PubMed, EMBASE, Web of Science, and Scopus, for studies evaluating the efficacy of omega-3 polyunsaturated fatty acids (PUFAs) for the prevention of ICD events for VT or VF, published up to December 1, 2023.
RESULTS
Four trials were finally included in the study. The pooled risk ratios for mortality and ICD events were 0.87 (95% CI:0.58-1.32) and 0.75 (95% CI:0.48-1.18), respectively.
CONCLUSION
No significant effect was discovered to support the antiarrhythmic properties or survival advantages of n-3 polyunsaturated fatty acids (PUFA) in individuals with implanted implantable cardioverter-defibrillators (ICD).
PubMed: 38584673
DOI: 10.1016/j.ijcha.2024.101397 -
Resuscitation Plus Jun 2024To evaluate the effectiveness of Rapid Cycle Deliberate Practice (RCDP) compared to traditional instruction or other forms of learning on resuscitation training outcomes... (Review)
Review
AIM
To evaluate the effectiveness of Rapid Cycle Deliberate Practice (RCDP) compared to traditional instruction or other forms of learning on resuscitation training outcomes and on clinical and/or patient-related outcomes.
METHODS
As part of the continuous evidence evaluation process of the International Liaison Committee on Resuscitation it was conducted this review and searched Medline, Embase and Cochrane from inception to Feb 12th, 2024. Risk of bias assessment was performed with the Risk of Bias in Non-randomized Studies of Interventions assessment tool and the Revised Cochrane risk-of-bias tool for randomized trials. The GRADE approach was used to evaluate the overall certainty of evidence for each outcome.
RESULTS
4420 abstracts were retrieved by the initial search and 10 additional studies were identified through other resources. Sixty-five studies were selected for eligibility and nine simulated studies met the inclusion criteria. A -analysis was performed on three outcomes: time to chest compressions, time to defibrillation and time to first epinephrine given, which showed that RCDP had significantly shorter time to defibrillation and time to administration of epinephrine than controls. The overall certainty of evidence was very low across all outcomes due to risk of bias, inconsistency, indirectness, and imprecision.
CONCLUSION
It may be reasonable to include RCDP as an instructional design feature of basic and advanced life support training. However, substantial variations of delivering RCDP exist and there is no uniform use of RCDP. Further research is necessary on medium/long-term effects of RCDP training, and on the effects on different target groups of training.
PubMed: 38757054
DOI: 10.1016/j.resplu.2024.100648 -
Journal of Medical Internet Research Apr 2024Telemonitoring patients with cardiac implantable electronic devices (CIEDs) can improve their care management. However, the results of cost-effectiveness studies are... (Review)
Review
BACKGROUND
Telemonitoring patients with cardiac implantable electronic devices (CIEDs) can improve their care management. However, the results of cost-effectiveness studies are heterogeneous. Therefore, it is still a matter of debate whether telemonitoring is worth the investment.
OBJECTIVE
This systematic review aims to investigate the cost-effectiveness of telemonitoring patients with CIEDs, focusing on its key drivers, and the impact of the varying perspectives.
METHODS
A systematic review was performed in PubMed, Web of Science, Embase, and EconLit. The search was completed on July 7, 2022. Studies were included if they fulfilled the following criteria: patients had a CIED, comparison with standard care, and inclusion of health economic evaluations (eg, cost-effectiveness analyses and cost-utility analyses). Only complete and peer-reviewed studies were included, and no year limits were applied. The exclusion criteria included studies with partial economic evaluations, systematic reviews or reports, and studies without standard care as a control group. Besides general study characteristics, the following outcome measures were extracted: impact on total cost or income, cost or income drivers, cost or income drivers per patient, cost or income drivers as a percentage of the total cost impact, incremental cost-effectiveness ratios, or cost-utility ratios. Quality was assessed using the Consensus Health Economic Criteria checklist.
RESULTS
Overall, 15 cost-effectiveness analyses were included. All studies were performed in Western countries, mainly Europe, and had primarily a male participant population. Of the 15 studies, 3 (20%) calculated the incremental cost-effectiveness ratio, 1 (7%) the cost-utility ratio, and 11 (73%) the health and cost impact of telemonitoring. In total, 73% (11/15) of the studies indicated that telemonitoring of patients with implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs was cost-effective and cost-saving, both from a health care and patient perspective. Cost-effectiveness results for telemonitoring of patients with pacemakers were inconclusive. The key drivers for cost reduction from a health care perspective were hospitalizations and scheduled in-office visits. Hospitalization costs were reduced by up to US $912 per patient per year. Scheduled in-office visits included up to 61% of the total cost reduction. Key drivers for cost reduction from a patient perspective were loss of income, cost for scheduled in-office visits and transport. Finally, of the 15 studies, 8 (52%) reported improved quality of life, with statistically significance in only 1 (13%) study (P=.03).
CONCLUSIONS
From a health care and patient perspective, telemonitoring of patients with an ICD or a cardiac resynchronization therapy ICD is a cost-effective and cost-saving alternative to standard care. Inconclusive results were found for patients with pacemakers. However, telemonitoring can lead to a decrease in providers' income, mainly due to a lack of reimbursement. Introducing appropriate reimbursement could make telemonitoring sustainable for providers while still being cost-effective from a health care payer perspective.
TRIAL REGISTRATION
PROSPERO CRD42022322334; https://tinyurl.com/puunapdr.
Topics: Humans; Male; Cost-Benefit Analysis; Quality of Life; Defibrillators, Implantable; Cardiac Resynchronization Therapy; Europe
PubMed: 38640471
DOI: 10.2196/47616