Journal of Clinical Medicine Aug 2023The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided... (Review)
Review
PURPOSE
The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla.
METHODS
Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS.
RESULTS
A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34-2.29) at the entry point and 2.95 mm (95% CI: 1.66-4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04-4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83-1.54) at the entry point and 1.80 mm (95% CI: 1.10-2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43-2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69-2.39) at the entry point and 3.23 mm (95% CI: 2.34-4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86-5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups ( < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements.
CONCLUSION
Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.
PubMed: 37629460
DOI: 10.3390/jcm12165418 -
Clinical and Experimental Dental... Dec 2023The aim of this study was to review the selection criteria of resin cements for different types of partial coverage restorations (PCRs) and investigate if the type of... (Review)
Review
OBJECTIVE
The aim of this study was to review the selection criteria of resin cements for different types of partial coverage restorations (PCRs) and investigate if the type of restorations or restorative materials affect the type of selected resin cement.
MATERIALS AND METHODS
An electronic search (1991-2023) was performed in PubMed, Medline, Scopus, and Google Scholar databases by combinations of related keywords.
RESULTS
A total of 68 articles were included to review the selection criteria based on the advantages, disadvantages, indications, and performance of resin cements for different types of PCRs.
CONCLUSIONS
The survival and success of PCRs are largely affected by appropriate cement selection. Self-curing and dual-curing resin cements have been recommended for the cementation of metallic PCRs. The PCRs fabricated from thin, translucent, and low-strength ceramics could be adhesively bonded by light-cure conventional resin cements. Self-etching and self-adhesive cements, especially dual-cure types, are not generally indicated for laminate veneers.
Topics: Resin Cements; Ceramics; Dental Cements; Cementation
PubMed: 37427500
DOI: 10.1002/cre2.761 -
Medicina (Kaunas, Lithuania) Nov 2023: More than a billion people worldwide suffer from chronic periodontitis. The primary etiological factor of periodontal diseases is dental plaque and the bacteria it... (Review)
Review
: More than a billion people worldwide suffer from chronic periodontitis. The primary etiological factor of periodontal diseases is dental plaque and the bacteria it contains, particularly , , , , and . Zinc, owing to its antibacterial properties, can be employed in periodontology. The objective of this review was to analyze scientific literature that examines the effects of zinc on periopathogens. : A systematic review protocol of scientific literature was designed following PRISMA recommendations. Data search was conducted in PubMed, Web of Science, and ScienceDirect databases. Full-text articles in English that examine the effects of zinc on periopathogens and were published between 2011 and 2021 were included. Fifteen articles were included in the analysis based on inclusion criteria. ZnO exhibited antibacterial activity against and ( < 0.001). The minimum inhibitory concentration against was 10 μg/mL. ZnO demonstrated a significant antibacterial effect, as evidenced by inhibition zones of 15.10 mm for , 13.36 mm for , 12.98 mm for , and 14.01 mm for Zn (II)-based polymers inhibited the and genes of . Titanium dental implants coated with ZnO effectively disrupted the cell walls of and . ZnO inhibited the growth of within 2 h and the growth of and within 3 h. ZnO exhibited nontoxic effects, and concentrations up to 0.8 mg/L increased cell survival rates by up to 90%. The analysis of the literature confirms the antibacterial action of zinc against periodontal pathogenic bacteria. At low concentrations, these substances do not exhibit cytotoxic effects on fibroblasts.
Topics: Humans; Anti-Bacterial Agents; Anti-Infective Agents; Chronic Periodontitis; Organic Chemicals; Porphyromonas gingivalis; Systematic Reviews as Topic; Zinc; Zinc Oxide
PubMed: 38138191
DOI: 10.3390/medicina59122088 -
The Journal of Prosthetic Dentistry Sep 2023The implant abutment connection interface has been considered one of the major factors affecting the outcome of implant therapy. However, drawbacks of traditional... (Meta-Analysis)
Meta-Analysis Review
Comparison of external, internal flat-to-flat, and conical implant abutment connections for implant-supported prostheses: A systematic review and network meta-analysis of randomized clinical trials.
STATEMENT OF PROBLEM
The implant abutment connection interface has been considered one of the major factors affecting the outcome of implant therapy. However, drawbacks of traditional meta-analyses are the inability to compare more than 2 treatments at a time, which complicates the decision-making process for dental clinicians, and the lack of a network meta-analysis.
PURPOSE
The purpose of this network meta-analysis was to assess whether the implant abutment connection influences the outcome of implant-supported prostheses.
MATERIAL AND METHODS
An electronic search was undertaken to identify all randomized clinical trials comparing the effect of at least 2 different implant abutment connection designs published from 2009 up to May 2020. Outcome variables were implant survival rate, peri-implant marginal bone loss, and biologic and prosthetic complication rates at 12 months after prosthetic loading. Relevant information was extracted, and quality and risk of bias assessed. Pairwise meta-analyses and network meta-analyses based on a multivariate random-effects meta-regression were performed to assess the comparisons (α=.05 for all analyses).
RESULTS
For peri-implant marginal bone loss and prosthetic complications, conical interfaces were determined to be the most effective, with significant differences when compared with external hexagonal connections (P=.011 and P=.038, respectively). No significant differences were found among the implant abutment connections in terms of survival and biologic complications (P>.05 in all direct, indirect, and mixed comparisons).
CONCLUSIONS
After 1 year of loading, conical connections showed lower marginal bone loss and fewer prosthetic complications than external hexagonal connections. However, the implant abutment connection design had no influence on the implant survival and biologic complication rates.
Topics: Dental Implants; Network Meta-Analysis; Dental Implant-Abutment Design; Dental Prosthesis, Implant-Supported; Randomized Controlled Trials as Topic; Biological Products
PubMed: 34776267
DOI: 10.1016/j.prosdent.2021.09.029 -
Medicina (Kaunas, Lithuania) Dec 2023: The present systematic review and meta-analysis undertake a comparison of studies that examine the accuracy of robot-assisted dental implant placement in relation to... (Meta-Analysis)
Meta-Analysis Review
Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies.
: The present systematic review and meta-analysis undertake a comparison of studies that examine the accuracy of robot-assisted dental implant placement in relation to static computer-assisted implant surgery (SCAIS), dynamic computer-assisted implant surgery (DCAIS), and freehand procedures. This study aims to provide a comprehensive understanding of the precision of robot-assisted dental implant placement and its comparative efficacy in relation to other placement techniques. : The guidelines recommended by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were used to organize and compose this review. Four electronic databases (PubMed, Web of Science, Scopus, and Cochrane) were systematically searched for pertinent articles. Articles were selected following the inclusion and exclusion criteria. Qualitative and quantitative analyses of the selected articles were performed. : The initial electronic search resulted in 1087 hits. Based on the inclusion and exclusion criteria, five articles were selected for qualitative analysis, out of which three were considered for quantitative analysis. Three parameters were considered for accuracy evaluation (angular, coronal, and apical deviation). The mean angular deviation was -1.22 degrees (95% CI, -1.06--1.39), the mean coronal deviation was -0.15 mm (95% CI, -0.24--0.07), and the mean apical deviation was -0.19 mm (95% CI, -0.27--0.10). : The robotic implant system was found to have significantly lower angular deviations and insignificantly lower coronal and apical deviations compared to DCAIS. Within the limitations of this review, it can be concluded that robot-assisted implant placement in resin models permits higher accuracy compared to DCAIS and SCAIS systems. However, due to the limited number of comparative studies with high heterogeneity, the findings of this review should be interpreted with caution. Further research is necessary to confirm the clinical application of robotics in implant surgery.
Topics: Humans; Dental Implants; Robotics; Surgery, Computer-Assisted; Research Design; Computers; Imaging, Three-Dimensional
PubMed: 38276045
DOI: 10.3390/medicina60010011 -
Maxillofacial Plastic and... Jul 2023This systematic review and meta-analysis aimed to evaluate the factors influencing and success rates of dental implants for functional and dental rehabilitation... (Review)
Review
Outcomes and influential factors in functional and dental rehabilitation following microvascular fibula flap reconstruction in the maxillomandibular region: a systematic review and meta-analysis.
BACKGROUND
This systematic review and meta-analysis aimed to evaluate the factors influencing and success rates of dental implants for functional and dental rehabilitation following microvascular fibula flap reconstruction in the maxillomandibular region.
MAIN TEXT
We conducted a comprehensive search of electronic databases, including MEDLINE, Web of Science, Embase, Scopus, and Cochrane's CENTRAL, as well as gray literature sources and manual searches of notable journals. The search was performed from inception until February 2023. Studies were included if they examined functional and dental rehabilitation outcomes in patients receiving maxillofacial reconstruction using microvascular fibula flaps and were retrospective or prospective cohort studies involving human subjects. Case-control studies, research involving other reconstruction methods, and animal-based studies were excluded. Data was extracted and confirmed by two independent researchers, and risk of bias was assessed using the Newcastle-Ottawa Scale. Meta-analyses were conducted for dental implant and graft success rate, with separate analyses for different factors affecting the outcome. Heterogeneity was evaluated using Cochran's Q test and the I test. The pooled success rate for implants was 92% and for grafts, 95%, with significant heterogeneity. Implants in fibular grafts had a 2.91 times higher failure rate than those in natural bones. Radiated bone and smoking were identified as factors influencing implant failure, with radiated bone having a 2.29 times higher risk and smokers having a 3.16 times higher risk compared to their respective counterparts. Patient-reported outcomes showed improvements in key areas such as dietary intake, mastication, speech, and esthetics. The success rates declined over time, emphasizing the importance of long-term follow-up.
CONCLUSIONS
Dental implants in free fibula grafts generally have favorable success rates, with minimal bone resorption, manageable probing depths, and limited bleeding on probing. Implant success is influenced by factors such as smoking and radiated bone.
PubMed: 37418121
DOI: 10.1186/s40902-023-00392-8 -
Pharmaceutics Feb 2024Bone defects represent an everyday challenge for clinicians who work in the fields of orthopedic surgery, maxillofacial and oral surgery, otorhinolaryngology, and dental... (Review)
Review
Bone defects represent an everyday challenge for clinicians who work in the fields of orthopedic surgery, maxillofacial and oral surgery, otorhinolaryngology, and dental implantology. Various bone substitutes have been developed and utilized, according to the needs of bone reconstructive surgery. Carbonate apatite has gained popularity in recent years, due to its excellent tissue behavior and osteoconductive potential. This systematic review aims to evaluate the role of carbonate apatite in bone reconstructive surgery and tissue engineering, analyze its advantages and limitations, and suggest further directions for research and development. The Web of Science, PubMed, and Scopus electronic databases were searched for relevant review articles, published from January 2014 to 21 July 2023. The study was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Eighteen studies were included in the present review. The biological properties and medical applications of carbonate apatite (COAp) are discussed and evaluated. The majority of articles demonstrated that COAp has excellent biocompatibility, resorbability, and osteoconductivity. Furthermore, it resembles bone tissue and causes minimal immunological reactions. Therefore, it may be successfully utilized in various medical applications, such as bone substitution, scaffolding, implant coating, drug delivery, and tissue engineering.
PubMed: 38399345
DOI: 10.3390/pharmaceutics16020291 -
Cureus Nov 2023Congenital clefts impair function and appearance, thus impacting a patient's social and mental health. A multidisciplinary team that can offer comprehensive treatment... (Review)
Review
Congenital clefts impair function and appearance, thus impacting a patient's social and mental health. A multidisciplinary team that can offer comprehensive treatment from infancy through maturity and beyond can successfully address these abnormalities. Dental rehabilitation is very important for these patients; these abnormalities should be identified and must be treated accordingly. Hence it is of utmost importance to know the success rate and changes in quality of life from patient satisfaction in order to plan future treatment goals when coming across such cases. The aim of this article is to determine success rate, esthetics, and patient satisfaction in implant-based oral rehabilitation in bone-grafted regions of cleft patients. Registration was carried out in PROSPERO (International Prospective Register of Systematic Review) with registration number CRD42022329861 on May 7, 2022. Medical Subject Headings (MeSH) terms such as cleft lip, cleft palate, survival rate, and dental implants were used to handpick articles via an electronic database. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed to compile all the data gathered from an electronic database. According to the collected data, 93.5% of the survival rate with dental implants was noted irrespective of the type of bone grafts used. Also, improvement in quality of life was achieved in these patients. Effectiveness, esthetics, and success rate are very well achievable with implants in cleft patients. Although the aesthetics are not equivalent to that of dental implants in normal patients, patient satisfaction is still satisfactory in patients with dental implants in bone-grafted regions of cleft lip and palate.
PubMed: 38125258
DOI: 10.7759/cureus.49101 -
BMC Oral Health Aug 2023A treatment approach that is widely used as a permanent and natural replacement for missing or extracted teeth is dental implants .VR is a computer-generated simulation...
BACKGROUND AND OBJECTIVE
A treatment approach that is widely used as a permanent and natural replacement for missing or extracted teeth is dental implants .VR is a computer-generated simulation that creates a three-dimensional (3D) image or environment. Advances in VR -based learning allow learners and students to practice and also help professionals plan a wide variety of surgical procedures, including the correct placement of dental implants. Therefore, in this systematic review, our aim was to investigate and evaluate the available virtual reality tools for dental implants and their effectiveness.
MATERIALS AND METHODS
Studies published up to 01/30/2023 which report the applications of using virtual reality technology in dental implants, were reviewed in three databases, including PubMed, Web of Science, and Scopus. All studies with evidence reporting the role of virtual reality technology in the field of dental implants were included in our analyses, written in English and published in peer-reviewed form, are included. Theoretical articles, and letters that did not provide original data, as well as studies that reported incomplete information, were excluded. Two reviewers independently assessed search results, extracted data, and assessed the quality of the included studies, and decisive agreement was reached by discussion and consultation with the third researcher. Narrative synthesis was undertaken to summarize and report the findings.
RESULTS
Out of 1633 initial search results, nine were included in the present study based on the inclusion criteria. The focus of seven studies was on teaching and learning, and two studies have examined the implant planning procedure. The most commonly used hardware and software were head-mounted display and Unity3D, respectively. In almost all studies, the results showed that the use of virtual reality-based systems improves and enhances the skills of users, including dental students and specialists.
CONCLUSIONS
Our findings showed that VR is an effective method for teaching and planning the implant process. Although the use of VR technology is limited for various reasons such as cost, it can increase the skills of dental professionals in performing dental implants.
Topics: Humans; Dental Implants; Virtual Reality; Computer Simulation; Databases, Factual; Learning
PubMed: 37641060
DOI: 10.1186/s12903-023-03290-7 -
International Journal of Molecular... Aug 2023The use of platelet-rich plasma (PRP) has gained increasing interest in recent decades. The platelet secretome contains a multitude of growth factors, cytokines,... (Review)
Review
The use of platelet-rich plasma (PRP) has gained increasing interest in recent decades. The platelet secretome contains a multitude of growth factors, cytokines, chemokines, and other biological biomolecules. In recent years, developments in the field of platelets have led to new insights, and attention has been focused on the platelets' released extracellular vesicles (EVs) and their role in intercellular communication. In this context, the aim of this review was to compile the current evidence on PRP-derived extracellular vesicles to identify the advantages and limitations fortheir use in the upcoming clinical applications. A total of 172 articles were identified during the systematic literature search through two databases (PubMed and Web of Science). Twenty publications met the inclusion criteria and were included in this review. According to the results, the use of PRP-EVs in the clinic is an emerging field of great interest that represents a promising therapeutic option, as their efficacy has been demonstrated in the majority of fields of applications included in this review. However, the lack of standardization along the procedures in both the field of PRP and the EVs makes it extremely challenging to compare results among studies. Establishing standardized conditions to ensure optimized and detailed protocols and define parameters such as the dose or the EV origin is therefore urgent. Further studies to elucidate the real contribution of EVs to PRP in terms of composition and functionality should also be performed. Nevertheless, research on the field provides promising results and a novel basis to deal with the regenerative medicine and drug delivery fields in the future.
Topics: Blood Platelets; Cell Communication; Extracellular Vesicles; Platelet-Rich Plasma; Regenerative Medicine
PubMed: 37685849
DOI: 10.3390/ijms241713043