-
BMC Oral Health Sep 2023A possible relationship between periodontitis (PD) and COVID-19 and its adverse outcomes has been suggested. Hence, the present systematic review and meta-analysis aimed... (Meta-Analysis)
Meta-Analysis
BACKGROUND
A possible relationship between periodontitis (PD) and COVID-19 and its adverse outcomes has been suggested. Hence, the present systematic review and meta-analysis aimed to investigate the available evidence regarding the potential association between periodontitis (PD) and COVID-19 and its adverse outcomes.
MATERIALS AND METHODS
PubMed, Scopus, Web of Science, and Google Scholar were searched for relevant studies published up to April 15, 2023. Studies that evaluated the association between PD and COVID-19 were included. Risk of bias was evaluated by two reviewers, and meta-analyses were performed using RevMan 5.3 software.
RESULTS
A total of 22 studies involving 92,535 patients from USA, Europe, Asia, the Middle East and South America were included; of these, 12 were pooled into the meta-analysis. Most of the studies (19 studies) reported a significant association between PD and COVID-19. The pooled data found a significant association between PD and COVID-19 outcomes: more severe symptoms (OR = 6.95, P = 0.0008), ICU admissions (OR = 3.15, P = 0.0001), and mortality (OR = 1.92, P = 0.21). Additionally, compared to mild PD, severe PD was significantly associated with higher risks of severe COVID-19 outcomes: severe symptoms (P = 0.02); ICU admission (P = 0.0001); and higher mortality rates (P = 0.0001). The results also revealed 58% higher risk for COVID-19 infection in patients with PD (P = 0.00001).
CONCLUSIONS
The present findings suggest a possible association between poor periodontal health and the risk of poor COVID-19 outcomes. However, owing to the observed methodological heterogeneity across the included studies, further prospective cohort studies with standardized methodologies are warranted to further unravel the potential association between periodontal disease and COVID-19 and its adverse outcomes.
Topics: Humans; Prospective Studies; COVID-19; Periodontal Diseases; Europe; Hospitalization
PubMed: 37689665
DOI: 10.1186/s12903-023-03378-0 -
Materials (Basel, Switzerland) Sep 2023The current review aims to provide an overview of the most recent research in the last 10 years on the potentials of graphene in the dental surgery field, focusing on... (Review)
Review
The current review aims to provide an overview of the most recent research in the last 10 years on the potentials of graphene in the dental surgery field, focusing on the potential of graphene oxide (GO) applied to implant surfaces and prosthetic abutment surfaces, as well as to the membranes and scaffolds used in Guided Bone Regeneration (GBR) procedures. "Graphene oxide" and "dental surgery" and "dentistry" were the search terms utilized on the databases Scopus, Web of Science, and Pubmed, with the Boolean operator "AND" and "OR". Reviewers worked in pairs to select studies based on specific inclusion and exclusion criteria. They included animal studies, clinical studies, or case reports, and in vitro and in vivo studies. However, they excluded systematic reviews, narrative reviews, and meta-analyses. Results: Of these 293 studies, 19 publications were included in this review. The field of graphene-based engineered nanomaterials in dentistry is expanding. Aside from its superior mechanical properties, electrical conductivity, and thermal stability, graphene and its derivatives may be functionalized with a variety of bioactive compounds, allowing them to be introduced into and improved upon various scaffolds used in regenerative dentistry. This review presents state-of-the-art graphene-based dental surgery applications. Even if further studies and investigations are still needed, the GO coating could improve clinical results in the examined dental surgery fields. Better osseointegration, as well as increased antibacterial and cytocompatible qualities, can benefit GO-coated implant surgery. On bacterially contaminated implant abutment surfaces, the CO coating may provide the optimum prospects for soft tissue sealing to occur. GBR proves to be a safe and stable material, improving both bone regeneration when using GO-enhanced graft materials as well as biocompatibility and mechanical properties of GO-incorporated membranes.
PubMed: 37763569
DOI: 10.3390/ma16186293 -
BMC Oral Health Oct 2023Today dental implants represent an effective therapy in case of partial or total edentulism, with an excellent success rate. Despite the results obtained, there may be...
BACKGROUND
Today dental implants represent an effective therapy in case of partial or total edentulism, with an excellent success rate. Despite the results obtained, there may be biological or mechanical complications during the therapy, which lead to the loss of the implant. This systematic review aims to evaluate the current state of the art in the literature on techniques used for the removal of dental implants. Various aspects will be analyzed, such as the success of the technique, any complications, and the advantages and disadvantages of their use.
METHODS
Two reviewers conducted a literature analysis (PubMed, Embase, Web of Science) of the last 20 years (2003-2023). The main criterion analyzed was the success of the technique, while secondary outcomes such as complications and risks of the technique were also analyzed. 258 articles were identified in the various search databases. 42 eligible articles were subsequently identified after an article screening. Only 18 full texts were subsequently included in the review.
RESULTS
A total of 18 articles were selected and 1142 implants and 595 patients were included. The main techniques used were the Counter-Torque Ratchet Technique (CTRT), Piezoelectric bone surgery (PBS), trephine drills, carbide burs, Erbium, Chromium, Yttrium, Scandium, Gallium, Garnett (Er:Cr:YSGG) laser and carbon dioxide (CO) laser. Combined uses of techniques have been identified such as: PBS and trephine burs or carbide burs, trephine burs with the use of a 3d-printed guide, CTRT and trephine burs. The technique with the highest success rate, less morbidity for the patient, and less removal of bone appears to be the CTRT.
CONCLUSIONS
The use of conservative techniques, especially CTRT, in bone removal is useful to allow for immediate implant placement in the removal area. However, further studies with a high sample size are needed to be performed on all techniques, particularly new randomized controlled trials (RCTs) that allow for the analysis of the success of alternative techniques such as Laser and Piezosurgery, which appear to be very promising.
Topics: Humans; Dental Implants; Bone-Anchored Prosthesis; Dental Implantation, Endosseous; Yttrium; Lasers, Solid-State
PubMed: 37833674
DOI: 10.1186/s12903-023-03438-5 -
The Japanese Dental Science Review Dec 2023The use of graphecs excellent mechanical properties. However, it is necessary to evaluate the biological effects of this material. This systematic review aimed to... (Review)
Review
The use of graphecs excellent mechanical properties. However, it is necessary to evaluate the biological effects of this material. This systematic review aimed to observe and understand through studies the current state of the art regarding osseointegration, antimicrobial capacity, and the cytotoxicity of graphene coating applied to the surface of dental implant materials. Searches in PubMed, Embase, Science Direct, Web of Science, and Google Scholar databases were conducted between June and July 2021 and updated in May 2022 using the keywords: graphene, graphene oxide, dental implants, zirconium, titanium, peek, aluminum, disilicate, methyl-methacrylate, cytotoxicity, osseointegration, and bone regeneration. The criteria included in vivo and in vitro studies that evaluated antimicrobial capacity and/or osseointegration and/or cytotoxicity of dental implant materials coated with graphene compounds. The risk of bias for in vitro studies was assessed by the JBI tool, and for in vivo studies, Syrcle's risk of bias tool for animal studies was used. The database search resulted in 176 articles. Of the 18 articles selected for full reading, 16 remained in this systematic review. The use of graphene compounds as coatings on the surface of implant materials is promising because it promotes osseointegration and has antimicrobial capacity. However, further studies are needed to ensure its cytotoxic potential.
PubMed: 37680613
DOI: 10.1016/j.jdsr.2023.08.005 -
Journal of Oral & Maxillofacial Research 2024The purpose of this systematic review is to disclose the impact of autoimmune diseases and their medical treatment on dental implant survival and success. (Review)
Review
OBJECTIVES
The purpose of this systematic review is to disclose the impact of autoimmune diseases and their medical treatment on dental implant survival and success.
MATERIAL AND METHODS
A literature search was conducted using MEDLINE (PubMed), The Cochrane Library and Embase up to December 6, 2021. Any clinical study on patients with an autoimmune disease in whom implant therapy was performed was eligible. The quality of included studies was assessed using the Newcastle-Ottawa Scale. For each autoimmune disease group, data synthesis was divided into three groups: 1) overall results of the autoimmune disease, 2) overall results of corresponding control groups and 3) overall results of the autoimmune disease with a concomitant autoimmune disease (a subgroup of group 1). Descriptive statistics were used.
RESULTS
Of 4,865 identified articles, 67 could be included and mainly comprising case reports and retrospective studies with an overall low quality. Implant survival rate was 50 to 100% on patient and implant level after a weighted mean follow-up of 17.7 to 68.1 months. Implant success was sporadically reported. Data on immunosuppressive medication were too heterogeneously reported to allow detailed analysis.
CONCLUSIONS
Overall, a high implant survival rate was reported in patients with autoimmune diseases. However, the identified studies were characterized by a low quality. No conclusions could be made regarding implant success and the effect of immunosuppressants due to heterogeneous reporting.
PubMed: 38812949
DOI: 10.5037/jomr.2024.15101 -
Graphene loaded into dental polymers as reinforcement of mechanical properties: A systematic review.The Japanese Dental Science Review Dec 2023Graphene compounds are incorporated into polymers in order to improve their mechanical properties and in dentistry this modification favors the clinical performance of... (Review)
Review
Graphene compounds are incorporated into polymers in order to improve their mechanical properties and in dentistry this modification favors the clinical performance of these materials. The aim of this review was to evaluate graphene compounds, their concentrations, and their effect on mechanical properties as flexural, tensile, and compressive strength and hardness of polymethylmethacrylate (PMMA) and polyether-ether-ketone (PEEK) for dental application. The search was carried out in two steps in PubMed/Medline, Embase, Scopus, and Web of Science databases. The eligibility criteria included studies that incorporated pure graphene compounds into dental polymers and evaluated their mechanical properties. Were found 4984 results, of which 11 articles were included in this review. Graphene compounds: graphene oxide (GO), reduced graphene oxide (rGO), and graphene nanoplatelets (GNP) were incorporated into PMMA and PEEK, in concentrations ranging from 0.1 to 10 wt%. Concentrations lower than 0.75 wt% of GO in PMMA and 1 wt% of GNP in PEEK resulted in increased flexural, tensile, compression strength, and hardness of these polymers. It was concluded that the incorporation of graphene compounds in low concentrations increases dental polymers' mechanical properties.
PubMed: 37362606
DOI: 10.1016/j.jdsr.2023.06.003 -
Annals of Medicine and Surgery (2012) Aug 2023Augmented reality (AR) technology is being used recently in healthcare, especially for rehabilitation purposes, owing to its ability for repetition, rapid feedback, and...
UNLABELLED
Augmented reality (AR) technology is being used recently in healthcare, especially for rehabilitation purposes, owing to its ability for repetition, rapid feedback, and motivation for patients. This systematic review and meta-analysis aims to compare the efficacy of AR-based interventions to conventional physical interventions in improving balance, mobility, and fall risk.
MATERIAL AND METHODS
PubMed, Google Scholar, Scopus, and the Cochrane Central Register of Controlled Trials were systematically searched from inception to January 2023. Randomized trials and observational cohort studies comparing the effects of AR-based exercises with conventional training in patients 18 years and older were included in the analysis. Studies using virtual reality, case reports and series, reviews, meta-analyses, letters, and editorials were excluded. Post-intervention data on the Berg Balance Scale (BBS) and Timed Up and Go (TUG) Test were extracted and studied. The fixed-effects inverse variance model was utilized to pool the extracted data.
RESULTS
Out of 438 articles, seven articles (199 participants) comparing AR-based exercise with the standard training were included in the systematic review. Six articles with sufficient data on the parameters were included in the meta-analysis. AR-based exercises resulted in a significantly higher BBS score than conventional exercise (Hedge's g=0.48, 95% CI=0.19-0.77, <0.001). The BBS value was significantly higher in AR-based training of 8 weeks or more (Hedge's g=0.88, 95% CI=0.46-1.31) when compared with trainings conducted for less than 8 weeks (Hedge's g=0.11, 95% CI=-0.30 to 0.52), =0.01). Likewise, the TUG Test score was found to be to be significantly lower in ARgroup than the controls (Hedge's g= -0.54, 95% CI=-0.85 to -0.23, <0.01).
CONCLUSION
In comparison to conventional methods, AR-based exercises had higher improvements in balance, mobility, and fall risk parameters. The use of AR technology in elderly patients can promote independence while preventing falls and associated morbidity and mortality. There is a need for a larger randomized controlled trial to provide a more accurate comparison on efficacy and safety of different modalities of training.
PubMed: 37554880
DOI: 10.1097/MS9.0000000000000986 -
International Journal of Molecular... Dec 2023The dental material industry is rapidly developing resin-based composites (RBCs), which find widespread use in a variety of clinical settings. As such, their... (Review)
Review
The dental material industry is rapidly developing resin-based composites (RBCs), which find widespread use in a variety of clinical settings. As such, their biocompatibility has gained increasing interest. This literature review presents a summary of research into the cytotoxicity of methacrylate-based composites published from 2017 to 2023. Subject to analysis were 14 in vitro studies on human and murine cell lines. Cytotoxicity in the included studies was measured via MTT assay, LDH assay, and WST-1 assay. The QUIN Risk of Bias Tool was performed to validate the included studies. Included studies (based entirely on the results of in vitro studies) provide evidence of dose- and time-dependent cytotoxicity of dental resin-based composites. Oxidative stress and the depletion of cellular glutathione (GSH) were suggested as reasons for cytotoxicity. Induction of apoptosis by RBCs was indicated. While composites remain the golden standard of dental restorative materials, their potential cytotoxicity cannot be ignored due to direct long-term exposure. Further in vitro investigations and clinical trials are required to understand the molecular mechanism of cytotoxicity and produce novel materials with improved safety profiles.
Topics: Humans; Animals; Mice; Apoptosis; Biological Assay; Cell Line; Dental Materials; Glutathione
PubMed: 38203323
DOI: 10.3390/ijms25010152 -
Cureus Jan 2024The biocompatibility of 3D-printed dental resins has become a critical concern in modern dentistry due to the increasing utilization of additive manufacturing (AM)... (Review)
Review
BACKGROUND
The biocompatibility of 3D-printed dental resins has become a critical concern in modern dentistry due to the increasing utilization of additive manufacturing (AM) techniques in dental applications. These resins serve as essential materials for fabricating dental prostheses, orthodontic devices, and various dental components. As the clinical adoption of 3D printing in dentistry grows, it is imperative to comprehensively assess the biocompatibility of these materials to ensure patient safety and dental treatment efficacy. This systematic review aimed to evaluate the existing body of literature on the biocompatibility of 3D-printed dental resins, thereby providing valuable insights into the potential biological risks associated with their use.
METHODS
The search strategy to identify relevant papers was implemented across PubMed/MEDLINE, Scopus, Web of Science, Embase, Cochrane Library, CINAHL, and Google Scholar to identify relevant studies. Study selection was not limited to any particular timeframe of publishing. The revised CONSORT criteria were used to ascertain the authenticity and dependability of the review's outcomes. Comprehensive screening and eligibility assessment processes were conducted to select studies meeting predefined criteria. Biocompatibility-related parameters, including toxicity, mechanical properties, cell viability, and other relevant outcomes, were analyzed across selected studies using a standardized variable extraction protocol.
RESULTS
A total of 9 studies were included in the systematic review. The findings encompassed various aspects of biocompatibility assessment, including material composition, mechanical properties, cell viability, and cytotoxicity. Some studies revealed significant improvements in flexural strength and cell viability with specific resin formulations, demonstrating their potential for enhanced clinical utility. Conversely, certain resins exhibited cytotoxicity, while others displayed promising biocompatibility profiles.
CONCLUSION
As per the assessed findings, material composition, post-processing techniques, and manufacturing methods emerged as critical factors influencing biocompatibility outcomes. While some resins exhibited favorable biocompatibility profiles, others raised concerns due to cytotoxicity. These findings emphasize the need for careful consideration when selecting and implementing 3D-printed dental resins, with a focus on materials engineering and comprehensive biocompatibility testing. Further research is warranted to elucidate the long-term biocompatibility and clinical implications of these materials.
PubMed: 38318586
DOI: 10.7759/cureus.51721 -
Medicina (Kaunas, Lithuania) Dec 2023Zirconia-reinforced lithium silicate (ZLS) ceramic is a new innovative dental material with unique a chemical composition that is designed to combine harmoniously with... (Review)
Review
Zirconia-reinforced lithium silicate (ZLS) ceramic is a new innovative dental material with unique a chemical composition that is designed to combine harmoniously with the appropriate optical properties of lithium disilicate and the enhanced mechanical strength of zirconia. A thorough understanding of ZLS materials is essential for both clinicians and dental technicians. At present, the mechanical behavior and optical properties of the ZLS ceramic system have not been extensively researched, and there is still a lack of consensus regarding the fabrication process and clinical behavior of ZLS all-ceramic restorations. The aim of the present study was to present a selection of comprehensive information concerning zirconia-reinforced lithium silicate ceramics and their optical and mechanical properties, as well as to assess data regarding cementation procedures and clinical outcomes for ZLS all-ceramic restorations. Three electronic databases (PubMed, Web of Science, and the Cochrane Library) were used for the research by two independent reviewers. The search was limited to articles published in the English language, as well as clinical and in vitro studies of color and studies on mechanical behavior and the cementation procedures of ZLS restorations. The exclusion criteria comprised abstracts, questionnaire-based studies, case reports, literature reviews, and studies that were not available in English. Zirconia-reinforced lithium-silicate-based ceramic presents a unique and complex microstructure that increases mechanical resistance but decreases aesthetic appearance, especially its translucency, due to tetragonal zirconia content. A material's thickness, the color of the underlying tooth structure, and the resin cement shade are important factors that influence the final shade and aesthetic appearance of ZLS restorations. Mechanical properties, which are defined by the fracture toughness, flexural strength, elastic modulus, and hardness of ZLS ceramic are higher compared to feldspathic, lithium disilicate, and hybrid ceramics, as well as resin nanoceramics; however, they are lower than translucent or high-translucency zirconia. Acid etching, sandblasting, and laser etching represent the most used methods to prepare the ZLS restoration surfaces for proper bonding procedures.
Topics: Humans; Ceramics; Dentistry; Lithium; Materials Testing; Silicates; Surface Properties
PubMed: 38138238
DOI: 10.3390/medicina59122135