Journal of Clinical Medicine Apr 2024Accurate prenatal diagnosis of cleft lip and palate is essential to discuss severity prediction, perform appropriate parental counseling, and, at last, establish... (Review)
Review
Accurate prenatal diagnosis of cleft lip and palate is essential to discuss severity prediction, perform appropriate parental counseling, and, at last, establish long-term treatment planning. The aim of this systematic review was to analyze the accuracy of various imaging techniques for the prenatal diagnosis of cleft lip and palate, assess the pregnancy phase for orofacial clefts diagnosis, and study the different cleft types in terms of diagnostic methods, timing, and predictability. A search of the PubMed, EMBASE, Scopus, and Web of Science databases was conducted to identify potentially relevant studies published until January 2024. The quality of the selected articles was assessed using the Newcastle-Ottawa scale for methodological quality assessment of cohort studies and the QUADAS-2 scale for diagnostic test studies. A total of 18 studies met the eligibility criteria and were included in the review. The findings of this review indicate that the majority of studies showed improved diagnostic accuracy when supplementary techniques, such as 3D ultrasound or magnetic resonance imaging, were added to 2D ultrasound. The implementation of magnetic resonance imaging as a standard procedure could significantly improve the precision of diagnosing cleft lip and palate. Therefore, the diagnostic technique used will play a crucial role in the accuracy of the diagnosis.
PubMed: 38610855
DOI: 10.3390/jcm13072090 -
PloS One 2023In this review, we assessed the diagnostic efficiency of artificial intelligence (AI) models in detecting temporomandibular joint osteoarthritis (TMJOA) using... (Meta-Analysis)
Meta-Analysis
Artificial intelligence for detecting temporomandibular joint osteoarthritis using radiographic image data: A systematic review and meta-analysis of diagnostic test accuracy.
In this review, we assessed the diagnostic efficiency of artificial intelligence (AI) models in detecting temporomandibular joint osteoarthritis (TMJOA) using radiographic imaging data. Based upon the PRISMA guidelines, a systematic review of studies published between January 2010 and January 2023 was conducted using PubMed, Web of Science, Scopus, and Embase. Articles on the accuracy of AI to detect TMJOA or degenerative changes by radiographic imaging were selected. The characteristics and diagnostic information of each article were extracted. The quality of studies was assessed by the QUADAS-2 tool. Pooled data for sensitivity, specificity, and summary receiver operating characteristic curve (SROC) were calculated. Of 513 records identified through a database search, six met the inclusion criteria and were collected. The pooled sensitivity, specificity, and area under the curve (AUC) were 80%, 90%, and 92%, respectively. Substantial heterogeneity between AI models mainly arose from imaging modality, ethnicity, sex, techniques of AI, and sample size. This article confirmed AI models have enormous potential for diagnosing TMJOA automatically through radiographic imaging. Therefore, AI models appear to have enormous potential to diagnose TMJOA automatically using radiographic images. However, further studies are needed to evaluate AI more thoroughly.
Topics: Humans; Artificial Intelligence; ROC Curve; Temporomandibular Joint; Osteoarthritis; Diagnostic Tests, Routine
PubMed: 37450501
DOI: 10.1371/journal.pone.0288631 -
PloS One 2023Periorbital and orbital cellulitis are inflammatory conditions of the eye that can be difficult to distinguish using clinical examination alone. Computer tomography (CT)...
BACKGROUND
Periorbital and orbital cellulitis are inflammatory conditions of the eye that can be difficult to distinguish using clinical examination alone. Computer tomography (CT) scans are often used to differentiate these two infections and to evaluate for complications. Orbital ultrasound (US) could be used as a diagnostic tool to supplement or replace CT scans as the main diagnostic modality. No prior systematic review has evaluated the diagnostic test accuracy (DTA) of ultrasound compared to cross-sectional imaging.
OBJECTIVE
To conduct a systematic review of studies evaluating the DTA of orbital ultrasound compared with cross-sectional imaging, to diagnose orbital cellulitis.
METHODS
MEDLINE, EMBASE, CENTRAL, and Web of Science were searched from inception to August 10, 2022. All study types were included that enrolled patients of any age with suspected or diagnosed orbital cellulitis who underwent ultrasound and a diagnostic reference standard (i.e., CT or magnetic resonance imaging [MRI]). Two authors screened titles/abstracts for inclusion, extracted data, and assessed the risk of bias.
RESULTS
Of the 3548 studies identified, 20 were included: 3 cohort studies and 17 case reports/series. None of the cohort studies directly compared the diagnostic accuracy of ultrasound with CT or MRI, and all had high risk of bias. Among the 46 participants, diagnostic findings were interpretable in 18 (39%) cases which reported 100% accuracy. We were unable to calculate sensitivity and specificity due to limited data. In the descriptive analysis of the case reports, ultrasound was able to diagnose orbital cellulitis in most (n = 21/23) cases.
CONCLUSION
Few studies have evaluated the diagnostic accuracy of orbital ultrasound for orbital cellulitis. The limited evidence based on low quality studies suggests that ultrasound may provide helpful diagnostic information to differentiate orbital inflammation. Future research should focus studies to determine the accuracy of orbital US and potentially reduce unnecessary exposure to radiation.
Topics: Humans; Orbital Cellulitis; Ultrasonography; Magnetic Resonance Imaging; Radionuclide Imaging; Diagnostic Tests, Routine; Sensitivity and Specificity
PubMed: 37410730
DOI: 10.1371/journal.pone.0288011 -
European Journal of Orthopaedic Surgery... Aug 2023This study aims to examine the clinical and radiological outcomes of patients who underwent ACL reconstruction (ACLR) combined with anterior closed-wedge high tibial... (Meta-Analysis)
Meta-Analysis Review
Could anterior closed-wedge high tibial osteotomy be a viable option in patients with high posterior tibial slope who undergo anterior cruciate ligament reconstruction? A systematic review and meta-analysis.
PURPOSE
This study aims to examine the clinical and radiological outcomes of patients who underwent ACL reconstruction (ACLR) combined with anterior closed-wedge high tibial osteotomy (ACW-HTO) for posterior tibial slope (PTS) reduction to investigate the efficacy of this procedure in improving anterior knee stability and preventing graft failure in primary and revision ACLR.
METHODS
A literature search was conducted in six databases (PubMed, Embase, Medline, Web of Science, Cochrane, and Scopus). The study was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. The initial screening identified 1246 studies. Each eligible clinical article was screened according to the Oxford Centre for Evidence-Based Medicine 2011 levels of evidence (LoE), excluding clinical studies of LoE V. Quality assessment of the articles was performed using the ROBINS-I methodological evaluation. This systematic review and meta-analysis was registered on the International Prospective Register of Systematic Reviews (PROSPERO). For the outcomes that were possible to perform a meta-analysis, a p < 0.05 was considered statistically significant.
RESULTS
Five clinical studies were included in the final analysis. A total of 110 patients were examined. Pre- and post-operative clinical and objective tests that assess anteroposterior knee stability, PTS, clinical scores, and data on surgical characteristics, complications, return to sports activity, and graft failure after ACLR were investigated. A meta-analysis was conducted using R software, version 4.1.3 (2022, R Core Team), for Lysholm score and PTS outcomes. A statistically significant improvement for both these clinical and radiological outcomes (p < 0.05) after the ACW-HTO surgical procedure was found.
CONCLUSION
ACLR combined with ACW-HTO restores knee stability and function with satisfactory clinical and radiological outcomes in patients with an anterior cruciate ligament injury associated with a high PTS and seems to have a protective effect from further ruptures on the reconstructed ACL.
LEVEL OF EVIDENCE
Level IV.
Topics: Humans; Anterior Cruciate Ligament; Knee Joint; Anterior Cruciate Ligament Injuries; Tibia; Osteotomy; Anterior Cruciate Ligament Reconstruction; Retrospective Studies
PubMed: 36308547
DOI: 10.1007/s00590-022-03419-4 -
Cureus Oct 2023Due to the clear depiction of facial aesthetics and other craniofacial parameters, portraiture photography (PP) is becoming more and more necessary in modern clinical... (Review)
Review
Due to the clear depiction of facial aesthetics and other craniofacial parameters, portraiture photography (PP) is becoming more and more necessary in modern clinical practice. The studies chosen for this review's inclusion looked at how PP affected the orthodontic treatment and diagnostic procedure on the subjects who were watched in the studies. Studies published within the last decade precisely from 2013 were searched for across major online databases after devising a proper search strategy. Multiple reviewers created a specific data extraction form that was used for the investigation, followed by the evaluation of bias and the variables found in each of the chosen papers. This form was meant for the assessment for various variables encountered in this study. According to the meta-analysis, using PP was related with a statistically significant decrease in the risk of orthodontic treatment and diagnostic modalities, with odds ratios (OR) of 0.52 with a 95% confidence interval (CI) of (0.28, 0.96), and a relative risk (RR) of 0.66 with a CI of (0.45, 0.96). In orthodontics, PP is an important tool that offers useful data for diagnosis, treatment planning, and tracking treatment success. To validate the results of studies like ours, a sizable evidence sample is required due to the limited number of trials that have been performed in this area.
PubMed: 37933372
DOI: 10.7759/cureus.48054 -
Cureus Jan 2024Grisel's syndrome is an uncommon cervical spine condition marked by non-traumatic rotational subluxation of the atlantoaxial joint. This systematic review aims to... (Review)
Review
Grisel's syndrome is an uncommon cervical spine condition marked by non-traumatic rotational subluxation of the atlantoaxial joint. This systematic review aims to collect potential evidence from relevant studies that reported symptoms, diagnostic methods, and management options among pediatric cases of Grisel's syndrome post otolaryngology procedures, which can aid and guide the diagnosis and management in clinical practice. We conducted both electronic and manual search strategies within the potential databases and included case reports, case series, and articles; however, review papers and correspondence papers were excluded. The post-otolaryngology procedures included adenoidectomy, tonsillectomy, tympanoplasty, cochlear implantation, double opposing Z plasty and pharyngeal flap, and adenotonsillectomy. In this systematic review, we identified and analyzed 20 studies encompassing a total of 24 pediatric patients with Grisel's syndrome following otolaryngology procedures. The patient demographics revealed a fairly even distribution between females (45.83%) and males (50.00%), with ages ranging from 2.5 to 12 years. The most common otolaryngology procedures associated with Grisel's syndrome were adenoidectomy (29.17%) and adenotonsillectomy (33.33%). Clinical symptoms included neck pain (75.00%), torticollis (50.00%), and limited neck mobility (20.83%), while diagnostic confirmation primarily relied on CT scans (50.00%). Treatment strategies varied, with conservative measures being the most frequent choice, followed by surgical interventions in four cases (16.67%). Complications were reported in 20.83% of cases. Due to the rarity of this condition, our findings are limited to case reports only, which may limit the generalizability of results. Grisel syndrome can be effectively managed through conservative treatment, including antibiotics and anti-inflammatory drugs if diagnosed timely. Early diagnosis and prompt management are essential to avoid neurological and fatal complications. This analysis would contribute to improving clinical knowledge and treatment strategies while providing additional insights into this rare condition.
PubMed: 38187032
DOI: 10.7759/cureus.51739 -
Journal of Pharmacy & Bioallied Sciences Apr 2024May-Thurner syndrome (MTS) is an anatomical condition of external luminal compression of common iliac vein due to a partial obstruction of the common iliac vein between... (Review)
Review
May-Thurner syndrome (MTS) is an anatomical condition of external luminal compression of common iliac vein due to a partial obstruction of the common iliac vein between common iliac artery and lumbar vertebra causes deep-vein thrombosis, venous hypertension, and chronic venous insufficiencies. In this article, we review present evidence of the clinical diagnosis and management of MTS. Here, we conducted a literature review of studies on MTS. We also reviewed different clinical features, presentation, diagnostic methods, and therapeutic procedure for this condition. Most studies mentioned the diagnosis of this condition is performed by color Doppler, computed tomographic angiography, venography, and problem-solving cases by intravascular ultrasound technique. Nonsurgical methods of management are first line, and vascular surgery is reserved for refractory cases. Multiple modalities are required to reach the diagnosis of MTS, and noninvasive intervention radiology methods are the first line of management. This review highlights the presentations of MTS and outlines diagnostic procedure and management.
PubMed: 38882842
DOI: 10.4103/jpbs.jpbs_1135_23 -
The Medical Journal of Australia Dec 2023To review evaluations of the diagnostic accuracy of coronavirus disease 2019 (COVID-19) rapid antigen tests (RATs) approved by the Therapeutic Goods Administration (TGA)... (Review)
Review
COVID-19 rapid antigen tests approved for self-testing in Australia: published diagnostic test accuracy studies and manufacturer-supplied information. A systematic review.
OBJECTIVES
To review evaluations of the diagnostic accuracy of coronavirus disease 2019 (COVID-19) rapid antigen tests (RATs) approved by the Therapeutic Goods Administration (TGA) for self-testing by ambulatory people in Australia; to compare these estimates with values reported by test manufacturers.
STUDY DESIGN
Systematic review of publications in any language that reported cross-sectional, case-control, or cohort studies in which the participants were ambulatory people in the community or health care workers in hospitals in whom severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection was suspected, and the results of testing self-collected biological samples with a TGA-approved COVID-19 RAT were compared with those of reverse transcription-polymerase chain reaction (RT-PCR) testing for SARS-CoV-2. Estimates of diagnostic accuracy (sensitivity, specificity) were checked and compared with manufacturer estimates published on the TGA website.
DATA SOURCES
Publications (to 1 September 2022) identified in the Cochrane COVID-19 Study Register and the World Health Organization COVID-19 research database. Information on manufacturer diagnostic accuracy evaluations was obtained from the TGA website.
DATA SYNTHESIS
Twelve publications that reported a total of eighteen evaluations of eight RATs approved by the TGA for self-testing (manufacturers: All Test, Roche, Flowflex, MP Biomedicals, Clungene, Panbio, V-Chek, Whistling) were identified. Five studies were undertaken in the Netherlands, two each in Germany and the United States, and one each in Denmark, Belgium, and Canada; test sample collection was unsupervised in twelve studies, and supervised by health care workers or researchers in six. Estimated sensitivity with unsupervised sample collection ranged from 20.9% (MP Biomedicals) to 74.3% (Roche), and with supervised collection from 7.7% (V-Chek) to 84.4% (Panbio); the estimates were between 8.2 and 88 percentage points lower than the values reported by the manufacturers. Test specificity was high for all RATs (97.9-100%).
CONCLUSIONS
The risk of false negative results when using COVID-19 RATs for self-testing may be considerably higher than apparent in manufacturer reports on the TGA website, with implications for the reliability of these tests for ruling out infection.
Topics: Humans; COVID-19; SARS-CoV-2; Self-Testing; Cross-Sectional Studies; Reproducibility of Results; Sensitivity and Specificity; Diagnostic Tests, Routine; COVID-19 Testing
PubMed: 37903650
DOI: 10.5694/mja2.52151 -
The Lancet. Child & Adolescent Health May 2024Febrile infants presenting in the first 90 days of life are at higher risk of invasive and serious bacterial infections than older children. Modern clinical practice... (Meta-Analysis)
Meta-Analysis
Diagnostic test accuracy of procalcitonin and C-reactive protein for predicting invasive and serious bacterial infections in young febrile infants: a systematic review and meta-analysis.
BACKGROUND
Febrile infants presenting in the first 90 days of life are at higher risk of invasive and serious bacterial infections than older children. Modern clinical practice guidelines, mostly using procalcitonin as a diagnostic biomarker, can identify infants who are at low risk and therefore suitable for tailored management. C-reactive protein, by comparison, is widely available, but whether C-reactive protein and procalcitonin have similar diagnostic accuracy is unclear. We aimed to compare the test accuracy of procalcitonin and C-reactive protein in the prediction of invasive or serious bacterial infections in febrile infants.
METHODS
For this systematic review and meta-analysis, we searched MEDLINE, EMBASE, Web of Science, and The Cochrane Library for diagnostic test accuracy studies up to June 19, 2023, using MeSH terms "procalcitonin", and "bacterial infection" or "fever" and keywords "invasive bacterial infection*" and "serious bacterial infection*", without language or date restrictions. Studies were selected by independent authors against eligibility criteria. Eligible studies included participants aged 90 days or younger presenting to hospital with a fever (≥38°C) or history of fever within the preceding 48 h. The primary index test was procalcitonin, and the secondary index test was C-reactive protein. Test kits had to be commercially available, and test samples had to be collected upon presentation to hospital. Invasive bacterial infection was defined as the presence of a bacterial pathogen in blood or cerebrospinal fluid, as detected by culture or quantitative PCR; authors' definitions of serious bacterial infection were used. Data were extracted from selected studies, and the detection of invasive or serious bacterial infections was analysed with two models for each biomarker. Diagnostic accuracy was determined against internationally recognised cutoff values (0·5 ng/mL for procalcitonin, 20 mg/L for C-reactive protein) and pooled to calculate partial area under the curve (pAUC) values for each biomarker. Optimum cutoff values were identified for each biomarker. This study is registered with PROSPERO, CRD42022293284.
FINDINGS
Of 734 studies derived from the literature search, 14 studies (n=7755) were included in the meta-analysis. For the detection of invasive bacterial infections, pAUC values were greater for procalcitonin (0·72, 95% CI 0·56-0·79) than C-reactive protein (0·28, 0·17-0·61; p=0·016). Optimal cutoffs for detecting invasive bacterial infections were 0·49 ng/mL for procalcitonin and 13·12 mg/L for C-reactive protein. For the detection of serious bacterial infections, procalcitonin and C-reactive protein had similar pAUC values (0·55, 0·44-0·69 vs 0·54, 0·40-0·61; p=0·92). For serious bacterial infections, the optimal cutoffs for procalcitonin and C-reactive protein were 0·17 ng/mL and 16·18 mg/L, respectively. Heterogeneity was low for studies investigating the test accuracy of procalcitonin in detecting invasive bacterial infection (I=23·5%), high for studies investigating procalcitonin for serious bacterial infection (I=75·5%), and moderate for studies investigating C-reactive protein for invasive bacterial infection (I=49·5%) and serious bacterial infection (I=28·3%). The absence of a single definition of serious bacterial infection across studies was the greatest source of interstudy variability and potential bias.
INTERPRETATION
Within a large cohort of febrile infants, a procalcitonin cutoff of 0·5 ng/mL had a superior pAUC value to a C-reactive protein cutoff of 20 mg/L for identifying invasive bacterial infections. In settings without access to procalcitonin, C-reactive protein should therefore be used cautiously for the identification of invasive bacterial infections, and a cutoff value below 20 mg/L should be considered. C-reactive protein and procalcitonin showed similar test accuracy for the identification of serious bacterial infection with internationally recognised cutoff values. This might reflect the challenges involved in confirming serious bacterial infection and the absence of a universally accepted definition of serious bacterial infection.
FUNDING
None.
Topics: Infant; Child; Humans; Adolescent; C-Reactive Protein; Procalcitonin; Fever; Biomarkers; Bacterial Infections; Diagnostic Tests, Routine
PubMed: 38499017
DOI: 10.1016/S2352-4642(24)00021-X -
International Journal of Surgery... Jun 2024Deep learning (DL)-assisted detection and segmentation of intracranial hemorrhage stroke in noncontrast computed tomography (NCCT) scans are well-established, but... (Meta-Analysis)
Meta-Analysis
Deep learning-assisted detection and segmentation of intracranial hemorrhage in noncontrast computed tomography scans of acute stroke patients: a systematic review and meta-analysis.
BACKGROUND
Deep learning (DL)-assisted detection and segmentation of intracranial hemorrhage stroke in noncontrast computed tomography (NCCT) scans are well-established, but evidence on this topic is lacking.
MATERIALS AND METHODS
PubMed and Embase databases were searched from their inception to November 2023 to identify related studies. The primary outcomes included sensitivity, specificity, and the Dice Similarity Coefficient (DSC); while the secondary outcomes were positive predictive value (PPV), negative predictive value (NPV), precision, area under the receiver operating characteristic curve (AUROC), processing time, and volume of bleeding. Random-effect model and bivariate model were used to pooled independent effect size and diagnostic meta-analysis data, respectively.
RESULTS
A total of 36 original studies were included in this meta-analysis. Pooled results indicated that DL technologies have a comparable performance in intracranial hemorrhage detection and segmentation with high values of sensitivity (0.89, 95% CI: 0.88-0.90), specificity (0.91, 95% CI: 0.89-0.93), AUROC (0.94, 95% CI: 0.93-0.95), PPV (0.92, 95% CI: 0.91-0.93), NPV (0.94, 95% CI: 0.91-0.96), precision (0.83, 95% CI: 0.77-0.90), DSC (0.84, 95% CI: 0.82-0.87). There is no significant difference between manual labeling and DL technologies in hemorrhage quantification (MD 0.08, 95% CI: -5.45-5.60, P =0.98), but the latter takes less process time than manual labeling (WMD 2.26, 95% CI: 1.96-2.56, P =0.001).
CONCLUSION
This systematic review has identified a range of DL algorithms that the performance was comparable to experienced clinicians in hemorrhage lesions identification, segmentation, and quantification but with greater efficiency and reduced cost. It is highly emphasized that multicenter randomized controlled clinical trials will be needed to validate the performance of these tools in the future, paving the way for fast and efficient decision-making during clinical procedure in patients with acute hemorrhagic stroke.
Topics: Humans; Deep Learning; Intracranial Hemorrhages; Tomography, X-Ray Computed; Stroke; Sensitivity and Specificity
PubMed: 38489547
DOI: 10.1097/JS9.0000000000001266