Clinical Microbiology and Infection :... Apr 2024The current tools for tuberculosis (TB) treatment monitoring, smear microscopy and culture, cannot accurately predict poor treatment outcomes. Research into new TB...
SCOPE
The current tools for tuberculosis (TB) treatment monitoring, smear microscopy and culture, cannot accurately predict poor treatment outcomes. Research into new TB treatment monitoring tools (TMTs) is growing, but data are unreliable. In this article, we aim to provide guidance for studies investigating and evaluating TB TMT for use during routine clinical care. Here, a TB TMT would guide treatment during the course of therapy, rather than testing for a cure at the regimen's end. This article does not cover the use of TB TMTs as surrogate endpoints in the clinical trial context.
METHODS
Guidelines were initially informed by experiences during a systematic review of TB TMTs. Subsequently, a small content expert group was consulted for feedback on initial recommendations. After revision, feedback from substantive experts across sectors was sought.
QUESTIONS ADDRESSED BY THE GUIDELINE AND RECOMMENDATIONS
The proposed considerations and recommendations for studies evaluating TB TMTs for use during the treatment in routine clinical care fall into eight domains. We provide specific recommendations regarding study design and recruitment, outcome definitions, reference standards, participant follow-up, clinical setting, study population, treatment regimen reporting, and index tests and data presentation. Overall, TB TMTs should be evaluated in a manner similar to diagnostic tests, but TB TMT accuracy must be assessed at multiple timepoints throughout the treatment course, and TB TMTs should be evaluated in study populations who have already received a diagnosis of TB. Study design and outcome definitions must be aligned with the developmental phase of the TB TMT under evaluation. There is no reference standard for TB treatment response, so different reference standards and comparator tests have been proposed, the selection of which will vary depending on the developmental phase of the TMT under assessment. The use of comparator tests can assist in generating evidence. Clarity is required when reporting of timepoints, TMT read-outs, and analysis results. Implementing these recommendations will lead to higher quality TB TMT studies that will allow data to be meaningfully compared, thereby facilitating the development of novel tools to guide individual TB therapy and improve treatment outcomes.
Topics: Humans; Research Design; Treatment Outcome; Tuberculosis
PubMed: 38182047
DOI: 10.1016/j.cmi.2023.12.027 -
Cerebrovascular Diseases (Basel,... 2024Chronic internal carotid artery occlusion (CICAO) is a common cause of stroke and ischemia recurrence. An increasing number of reports have highlighted the potential of... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
Chronic internal carotid artery occlusion (CICAO) is a common cause of stroke and ischemia recurrence. An increasing number of reports have highlighted the potential of hybrid surgery for treating CICAO. There are few studies, specifically nonrandomized controlled trials, on the safety and effectiveness of hybrid surgery for the treatment of CICAO, so in this study, we hypothesized that hybrid surgery would be safe, have an acceptable complication rate and a high success rate.
METHODS
MEDLINE, Embase, Cochrane Library, and Web of Science databases were searched for relevant studies published up to January 30, 2023. The primary endpoint was recanalization rates of occluded vessels, and the secondary endpoint was perioperative death and procedure-related complications. Subgroup analysis focused on the recanalization rates of endovascular intervention (EI) and hybrid surgery, as well as the rates of recanalization below the clinoid segment and at the clinoid segment and beyond. The follow-up visit was conducted at least 3 months after surgery, and stenosis or occlusion recurrence was confirmed by review of CTA or DSA scan.
RESULTS
The databases were searched and 1,709 records were identified, of which 16 articles were used in the meta-analysis, and 464 CICAO patients with complete data who underwent hybrid surgery were enrolled. Hybrid surgery was associated with higher success rates (RD = 0.87, 95% CI [0.84-0.91], p < 0.00001) than EI (OR = 4.71, 95% CI [2.32-9.56], p < 0.0001). The procedural success rate in the below-clinoid segment group was significantly higher than that in the clinoid segment and beyond group (OR = 13.76, 95% CI [5.31-35.66], p < 0.00001). The total periprocedural complication rate was low (RD = 0.11, 95% CI [0.07-0.15], p < 0.00001 and RD = 0.04, 95% CI [0.00-0.07], p = 0.03). Target vessel restenosis or reocclusion occurred in 35 patients (8%) during the follow-up period (RD = 0.08, 95% CI [0.04-0.12], p < 0.0001).
CONCLUSION
Hybrid surgery is the combination of the advantages of open surgery and EI, has a high success rate and a low risk of recurrence of stenosis and occlusion in the long term. Randomized controlled trials on hybrid surgery for internal carotid artery occlusion are necessary.
Topics: Humans; Carotid Stenosis; Carotid Artery, Internal; Constriction, Pathologic; Treatment Outcome; Carotid Artery Diseases
PubMed: 38061340
DOI: 10.1159/000535373 -
Archives of Gynecology and Obstetrics Aug 2023Abnormal flow in the ductus venosus (DV) has been reported to be associated with adverse perinatal outcome, chromosomal abnormalities, and congenital heart defects... (Meta-Analysis)
Meta-Analysis
The diagnostic performance of the ductus venosus for the detection of cardiac defects in the first trimester: a systematic review and diagnostic test accuracy meta-analysis.
PURPOSE
Abnormal flow in the ductus venosus (DV) has been reported to be associated with adverse perinatal outcome, chromosomal abnormalities, and congenital heart defects (CHD). Aneuploid fetuses have increased risk of CHD, but there are discrepancies on the performance of this markers in euploid fetuses. The aim of this meta-analysis was to establish the predictive accuracy of DV for CHD.
METHODS
MEDLINE, EMBASE, and CINAHL were searched from inception to February 2022. No language or geographical restrictions were applied. Inclusion criteria regarded observational and randomized studies concerning first-trimester DV flow as CHD marker. Random effect meta-analyses to calculate risk ratio (RR) with 95% confidence interval (CI), hierarchical summary receiver-operating characteristics (HSROC), and bivariate models to evaluate diagnostic accuracy were used. Primary outcome was the diagnostic performance of DV in detecting prenatal CHD by means of area under the curve (AUROC). Subgroup analysis for euploid, high-risk, and normal NT fetuses was performed. Quality assessment of included papers was performed using QUADAS-2.
RESULTS
Twenty two studies, with a total of 204.829 fetuses undergoing first trimester scan with DV Doppler evaluation, fulfilled the inclusion criteria for this systematic review. Overall, abnormal DV flow at the time of first trimester screening was associated to an increased risk of CHD (RR 6.9, 95% CI 3.7-12.6; I = 95.2%) as well in unselected (RR: 6.4, 95% CI 2.5-16.4; I = 93.3%) and in euploid (RR: 6.45, 95% CI 3.3-12.6; I = 95.8%) fetuses. The overall diagnostic accuracy of abnormal DV in detecting CHD was good in euploid fetuses with an AUROC of 0.81 (95% CI 0.78-0.84), but it was poor in the high-risk group with an AUROC of 0.66 (95% CI 0.62-0.70) and in the unselected population with an AUROC of 0.44 (95% CI 0.40-0.49).
CONCLUSIONS
Abnormal DV in the first trimester increases the risk of CHD with a moderate sensitivity for euploid fetuses. In combination with other markers (NT, TV regurgitation) could be helpful to identify fetuses otherwise considered to be at low risk for CHD. In addition to the improvement of the fetal heart examination in the first trimester, this strategy can increase the detection of major CHD at earlier stage of pregnancy.
Topics: Female; Humans; Pregnancy; Chromosome Aberrations; Diagnostic Tests, Routine; Heart Defects, Congenital; Pregnancy Trimester, First; Ultrasonography, Prenatal
PubMed: 36315269
DOI: 10.1007/s00404-022-06812-w -
BMC Musculoskeletal Disorders Jun 2024At present, the core decompression (CD) has become the main surgical procedure for the treatment of osteonecrosis of the femoral head (ONFH); however, the CD surgery... (Meta-Analysis)
Meta-Analysis Comparative Study
Comparison of clinical efficacy of robot-assisted and freehand core decompression in the treatment of osteonecrosis of the femoral head: a systematic review and meta-analysis.
OBJECTIVE
At present, the core decompression (CD) has become the main surgical procedure for the treatment of osteonecrosis of the femoral head (ONFH); however, the CD surgery requires high operator experience and repeated fluoroscopy increases the radiation damage to patients, and medical staff. This article compares the clinical efficacy of robot-assisted and freehand CD for ONFH by meta-analysis.
METHODS
Computer searches of PubMed, Web of Science, Embase, Cochrane Library, Chinese National Knowledge Infrastructure, China Science and Technology Journal Database, WanFang, and Chinese BioMedical Literature Database were conducted from the time of database inception to November 15, 2023. The literature on the clinical efficacy of robot-assisted and freehand CD in the treatment of ONFH was collected. Two researchers independently screened the literature according to the inclusion and exclusion criteria, extracted data, and strictly evaluated the quality of the included literature. Outcome measures encompassed operative duration, intraoperative blood loss volume, frequency of intraoperative fluoroscopies, visual analog scale (VAS) score, Harris hip score (HHS), complications, and radiographic progression. Data synthesis was carried out using Review Manager 5.4.1 software. The quality of evidence was evaluated according to Grades of Recommendation Assessment Development and Evaluation (GRADE) standards.
RESULTS
Seven retrospective cohort studies involving 355 patients were included in the study. The results of meta-analysis showed that in the robot-assisted group, the operative duration (MD = -17.60, 95% CI: -23.41 to -11.78, P < 0.001), intraoperative blood loss volume (MD = -19.98, 95% CI: -28.84 to -11.11, P < 0.001), frequency of intraoperative fluoroscopies (MD = -6.60, 95% CI: -9.01 to -4.20, P < 0.001), and ΔVAS score (MD = -0.45, 95% CI: -0.67 to -0.22, P < 0.001) were significantly better than those in the freehand group. The GRADE evidence evaluation showed ΔVAS score as low quality and other indicators as very low quality. There was no significant difference in the terms of ΔHHS (MD = 0.51, 95% CI: -1.34 to 2.35, P = 0.59), complications (RR = 0.30, 95% CI: 0.03 to 2.74, P = 0.29), and radiographic progression (RR = 0.50, 95% CI: 0.25 to 1.02, P = 0.06) between the two groups.
CONCLUSION
There is limited evidence showing the benefit of robot-assisted therapy for treatment of ONFH patients, and much of it is of low quality. Therefore, caution should be exercised in interpreting these results. It is recommended that more high-quality studies be conducted to validate these findings in future studies.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/prospero/ #recordDetails, CRD42023420593.
Topics: Humans; Femur Head Necrosis; Decompression, Surgical; Treatment Outcome; Robotic Surgical Procedures; Operative Time
PubMed: 38890631
DOI: 10.1186/s12891-024-07592-x -
Cureus Jan 2024Point-of-care ultrasound (POCUS) is an imaging modality that has become a fundamental part of clinical care provided in the emergency department (ED). The applications... (Review)
Review
Point-of-care ultrasound (POCUS) is an imaging modality that has become a fundamental part of clinical care provided in the emergency department (ED). The applications of this tool in the ED have ranged from resuscitation, diagnosis, and therapeutic to procedure guidance. This review aims to summarize the evidence on the use of POCUS for diagnosis and procedure guidance. To achieve this, CrossRef, PubMed, Cochrane Library, Web of Science, and Google Scholar databases were extensively searched for studies published between January 2000 and November 2023. Additionally, the risk of bias assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies 2 (for studies on the diagnostic role of POCUS) and Cochrane Risk of Bias tool (for studies on the use of POCUS for procedure guidance). Furthermore, diagnostic accuracy outcomes were pooled using STATA 16 software (StatCorp., College Station, TX, USA), while outcomes related to procedure guidance were pooled using the Review Manager software. The study included 81 articles (74 evaluating the diagnostic application of POCUS and seven evaluating the use of POCUS in guiding clinical procedures). In our findings sensitivities and specificities for various conditions were as follows: appendicitis, 65% and 89%; hydronephrosis, 82% and 74%; small bowel obstruction, 93% and 82%; cholecystitis, 75% and 96%; retinal detachment, 94% and 91%; abscess, 95% and 85%; foreign bodies, 67% and 97%; clavicle fractures, 93% and 94%; distal forearm fractures, 97% and 94%; metacarpal fractures, 94% and 92%; skull fractures, 91% and 97%; and pleural effusion, 91% and 97%. A subgroup analysis of data from 11 studies also showed that the two-point POCUS has a sensitivity and specificity of 89% and 96%, while the three-point POCUS is 87% sensitive and 92% specific in the diagnosis of deep vein thrombosis. In addition, the analyses showed that ultrasound guidance significantly increases the overall success rate of peripheral venous access (p = 0.02) and significantly reduces the number of skin punctures (p = 0.01) compared to conventional methods. In conclusion, POCUS can be used in the ED to diagnose a wide range of clinical conditions accurately. Furthermore, it can be used to guide peripheral venous access and central venous catheter insertion.
PubMed: 38694948
DOI: 10.7759/cureus.52371 -
PloS One 2023This systematic scoping review aims to summarize findings regarding kinetic, kinematic, and electromyographic analyses of different characteristics (i.e., type/direction...
This systematic scoping review aims to summarize findings regarding kinetic, kinematic, and electromyographic analyses of different characteristics (i.e., type/direction and stance style) of the tennis serve and groundstroke. A systematic search of the literature was performed on the databases PubMed, Web of Science, and SportDiscus from their inception date till May 2023. A descriptive analysis of results was conducted. The literature search identified a total of N = 899 records, 23 of which met the inclusion criteria and were analysed in this review. A total of 229 participants aged 18 to 62 years participated in the studies. The studies revealed varying results, ranging from significantly lower/higher values to no significant differences between serve/groundstroke characteristics. These inconsistent results may most likely be attributed to discrepancies in the methodological approach such as players' age (18-62 years), sex (i.e., men only or both sexes), and performance level (i.e., recreational, intermediate, or advanced) as well as the applied measurement devices (i.e., force plate or pressure-detecting insoles; motion capture system, high-speed video recordings, or IMU sensors) and used outcomes (i.e., measured or estimated force etc.). Future research is needed to provide a comprehensive biomechanical analysis of different serve/groundstroke characteristics. Specifically, it is recommended to compare different tennis serve and groundstroke types/directions and stance styles in female and male age-matched players with diverging performance levels (i.e., recreational, intermediate, advanced) using combined (i.e., kinetic, kinematic, and electromyographic) biomechanical analysis.
Topics: Humans; Female; Male; Tennis; Bone Plates; Databases, Factual; Kinetics; Motion Capture
PubMed: 37590226
DOI: 10.1371/journal.pone.0290320 -
Journal of Clinical Medicine Jan 2024Thoracoscopic surgical biopsy has shown excellent histological characterization of undetermined interstitial lung diseases, although the morbidity rates reported are not... (Review)
Review
Thoracoscopic surgical biopsy has shown excellent histological characterization of undetermined interstitial lung diseases, although the morbidity rates reported are not negligible. In delicate patients, interstitial lung disease and restrictive ventilatory impairment morbidity are thought to be due at least in part to tracheal intubation with single-lung mechanical ventilation; therefore, spontaneous ventilation thoracoscopic lung biopsy (SVTLB) has been proposed as a potentially less invasive surgical option. This systematic review summarizes the results of SVTLB, focusing on diagnostic yield and operative morbidity. A systematic search for original studies regarding SVTLB published between 2010 to 2023 was performed. In addition, articles comparing SVTLB to mechanical ventilation thoracoscopic lung biopsy (MVTLB) were selected for a meta-analysis. Overall, 13 studies (two before 2017 and eleven between 2018 and 2023) entailing 675 patients were included. Diagnostic yield ranged from 84.6% to 100%. There were 64 (9.5%) complications, most of which were minor. There was no 30-day operative mortality. When comparing SVTLB to MVTLB, the former group showed a significantly lower risk of complications ( < 0.001), whereas no differences were found in diagnostic accuracy. The results of this review suggest that SVTLB is being increasingly adopted worldwide and has proven to be a safe procedure with excellent diagnostic accuracy.
PubMed: 38256508
DOI: 10.3390/jcm13020374 -
European Journal of Nuclear Medicine... Feb 2024Molecular imaging is pivotal in staging and response assessment of children with neuroblastoma (NB). [I]-metaiodobenzylguanidine (mIBG) is the standard imaging method;...
BACKGROUND
Molecular imaging is pivotal in staging and response assessment of children with neuroblastoma (NB). [I]-metaiodobenzylguanidine (mIBG) is the standard imaging method; however, it is characterised by low spatial resolution, time-consuming acquisition procedures and difficult interpretation. Many PET catecholaminergic radiotracers have been proposed as a replacement for [I]-mIBG, however they have not yet made it into clinical practice. We aimed to review the available literature comparing head-to-head [I]-mIBG with the most common PET catecholaminergic radiopharmaceuticals.
METHODS
We searched the PubMed database for studies performing a head-to-head comparison between [I]-mIBG and PET radiopharmaceuticals including meta-hydroxyephedrine ([C]C-HED), F-18F-3,4-dihydroxyphenylalanine ([F]DOPA) [I]mIBG and Meta-[18F]fluorobenzylguanidine ([F]mFBG). Review articles, preclinical studies, small case series (< 5 subjects), case reports, and articles not in English were excluded. From each study, the following characteristics were extracted: bibliographic information, technical parameters, and the sensitivity of the procedure according to a patient-based analysis (PBA) and a lesion-based analysis (LBA).
RESULTS
Ten studies were selected: two regarding [C]C-HED, four [F]DOPA, one [I]mIBG, and three [F]mFBG. These studies included 181 patients (range 5-46). For the PBA, the superiority of the PET method was reported in two out of ten studies (both using [F]DOPA). For LBA, PET detected significantly more lesions than scintigraphy in seven out of ten studies.
CONCLUSIONS
PET/CT using catecholaminergic tracers shows superior diagnostic performance than mIBG scintigraphy. However, it is still unknown if such superiority can influence clinical decision-making. Nonetheless, the PET examination appears promising for clinical practice as it offers faster image acquisition, less need for sedation, and a single-day examination.
Topics: Child; Humans; 3-Iodobenzylguanidine; Dihydroxyphenylalanine; Neuroblastoma; Positron Emission Tomography Computed Tomography; Positron-Emission Tomography; Radiopharmaceuticals
PubMed: 37962616
DOI: 10.1007/s00259-023-06486-9 -
Family Practice Feb 2024Recognition of acute diverticulitis is important to determine an adequate management strategy. Differentiating it from other gastrointestinal disorders is challenging as... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Recognition of acute diverticulitis is important to determine an adequate management strategy. Differentiating it from other gastrointestinal disorders is challenging as symptoms overlap. Clinical tests might assist the clinician with this diagnostic challenge. Previous reviews have focussed on prognostic questions and imaging examinations in secondary care.
OBJECTIVE
To evaluate the diagnostic accuracy of clinical tests feasible in primary care for acute diverticulitis in suspected patients.
METHOD
We have systematically searched multiple databases for diagnostic accuracy studies of tests feasible in primary care compared to a reference standard in suspected patients. Two reviewers independently selected studies, extracted data, and assessed study quality with the QUADAS-2 tool. We have meta-analysed the results in the case of more than four studies per index test.
RESULTS
Seventeen studies were included, all studies were performed in secondary care (median prevalence 48%). Individual signs and symptoms showed a wide range in sensitivity (range 0.00-0.98) and specificity (range 0.08-1.00). Of the four laboratory tests evaluated, CRP >10 mg/l had the highest sensitivity (range 0.89-0.96) with specificity ranging from 0.28 to 0.61. Ultrasound had the highest pooled sensitivity and specificity of 0.92 (95% CI 0.86-0.96) and 0.94 (95% CI 0.88-0.97), respectively.
CONCLUSION
None of the studies were performed in primary care. Individual signs and symptoms alone are insufficiently informative for acute diverticulitis diagnosis. CRP showed potential for ruling out and ultrasound had a high diagnostic accuracy. More research is needed about the diagnostic accuracy of these tests in primary care.
PROSPERO REGISTRATION NUMBER
CRD42021230622.
Topics: Humans; Sensitivity and Specificity; Ultrasonography; Diagnostic Tests, Routine; Primary Health Care
PubMed: 38271592
DOI: 10.1093/fampra/cmad118 -
Orthopaedic Surgery Sep 2023The tibial tubercle-trochlear groove (TT-TG) distance is now routinely utilized to help determine whether a realignment procedure is necessary for patients with patellar... (Review)
Review
Tibial Tubercle-Trochlear Groove Distance Has Better Diagnostic Reliability Than Tubercle-Posterior Cruciate Ligament Distance For Predicting Patellar Instability: A Systematic Review.
OBJECTIVE
The tibial tubercle-trochlear groove (TT-TG) distance is now routinely utilized to help determine whether a realignment procedure is necessary for patients with patellar instability. The tibial tubercle-posterior cruciate ligament (TT-PCL) distance has been explored as an alternative measurement. The aim of this study is to compare the reliability of TT-TG and TT-PCL; to explore whether there is a relationship between the TT-PCL and the TT-TG distance; to determine whether there is a relationship between the TT-TG and TT-PCL distances and knee rotation; and to compare the abilities of the TT-PCL distance and the TT-TG distance with predicted patellar instability.
METHOD
This systematic review was performed in accordance with PRISMA guidelines. Three databases, PubMed, EMBASE, and Cochrane Central Register of Controlled Trials, were searched from inception to September 2021 to identify clinical studies comparing TT-TG and TT-PCL distances to patellar instability. Data on patient baseline characteristics, TT-TG and TT-PCL distances, inter-observer reliability, and area under the receiver-operating characteristic curve (AUC) were recorded. The methodological quality of the studies was assessed using the quality assessment form recommended by the Agency for Healthcare Research and Quality (AHRQ).
RESULT
Twenty studies were included in the final analysis, comprising 2330 knees from 2260 patients. The current study showed that TT-TG and TT-PCL have similar observer reliability. The inter- and intra-observer reliability of TT-TG ranged from 0.807 to 0.98 and 0.553 to 0.99, respectively. The inter- and intra-observer reliability of TT-PCL ranged from 0.553 to 0.99 and 0.88 to 0.981, respectively. Six studies compared the AUC for predicting patellar instability and showed that TT-TG had better predictive performance than TT-PCL. Three studies reported a correlation between TT-TG and knee rotation, but no such relationship was found for TT-PCL. Eight studies reported a weak or moderate correlation between TT-TG and TT-PCL.
CONCLUSION
TT-TG and TT-PCL have similar inter- and intra-rater reliability (as measured by ICC), but TT-TG has greater discriminatory power to predict patellar instability than TT-PCL (as measured by AUC values and odds ratio). However, considering trochlear dysplasia and individual variations, future studies need to find more accurate and individualized methods to predict patellar instability.
Topics: Humans; Posterior Cruciate Ligament; Patellofemoral Joint; Joint Instability; Reproducibility of Results; Magnetic Resonance Imaging; Observer Variation; Tibia; Patellar Dislocation
PubMed: 37427672
DOI: 10.1111/os.13819