International Wound Journal Dec 2023Ankle Brachial Pressure Index (ABPI) measurement has long been considered the gold standard of vascular assessment for people with lower limb ulceration. Despite this,... (Review)
Review
Ankle Brachial Pressure Index (ABPI) measurement has long been considered the gold standard of vascular assessment for people with lower limb ulceration. Despite this, only around 15% of patients in the United Kingdom who require an ABPI measurement undergo the assessment. The Lanarkshire Oximetry Index (LOI) is a cheaper and arguably more accessible approach to vascular assessment and was initially proposed as an alternative to the ABPI in 2000. No synthesis of evidence related to the LOI has been performed since its introduction into the literature. Primary studies were sought to determine the clinimetric properties of the LOI and its level of agreement with ABPI assessments. Systematic searches of MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials, BNI, ProQuest Health and Medicine, Science Direct, Google Scholar and the British Library (online search) were conducted. Reference lists of identified studies were also reviewed to identify additional studies. Three primary studies met the inclusion criteria, reporting data from 307 patients and 584 limbs assessed using both the LOI and ABPI. All three studies reported fair to moderate kappa values for interrater reliability (κ = 0.290-0.747) and statistically significant positive correlation coefficients (r = 0.37, p < 0.001 in two studies) between the LOI and ABPI. The combined data from the three studies indicated a sensitivity of 52% (41.78-62.1, 95% confidence interval [CI]) and specificity of 96.08% (93.4-97.9, 95% CI) for the LOI using the ABPI as a reference. Additional data are required to indicate the safety of the LOI in practice. Data are also required to determine if the LOI is more acceptable to clinicians compared to the ABPI and whether there are any barriers/enablers to its implementation in practice. Given the relatively low specificity of the LOI, it may be beneficial to combine measurement of the LOI with a subjective clinical risk assessment tool to improve the sensitivity of this alternative approach to vascular assessment.
PubMed: 38050665
DOI: 10.1111/iwj.14519 -
Journal of Global Health Sep 2023Pulse oximetry has been used in medical care for decades. Its use quickly became standard of care in high resource settings, with delayed widespread availability and use...
BACKGROUND
Pulse oximetry has been used in medical care for decades. Its use quickly became standard of care in high resource settings, with delayed widespread availability and use in lower resource settings. Pulse oximetry training initiatives have been ongoing for years, but a map of the literature describing such initiatives among health care workers in low- and middle-income countries (LMICs) has not previously been conducted. Additionally, the coronavirus disease 2019 (COVID-19) pandemic further highlighted the inequitable distribution of pulse oximetry use and training. We aimed to characterise the landscape of pulse oximetry training for health care workers in LMICs prior to the COVID-19 pandemic as described in the literature.
METHODS
We systematically searched six databases to identify studies reporting pulse oximetry training among health care workers, broadly defined, in LMICs prior to the COVID-19 pandemic. Two reviewers independently assessed titles and abstracts and relevant full texts for eligibility. Data were charted by one author and reviewed for accuracy by a second. We synthesised the results using a narrative synthesis.
RESULTS
A total of 7423 studies were identified and 182 screened in full. A total of 55 training initiatives in 42 countries met inclusion criteria, as described in 66 studies since some included studies reported on different aspects of the same training initiative. Five overarching reasons for conducting pulse oximetry training were identified: 1) anaesthesia and perioperative care, 2) respiratory support programme expansion, 3) perinatal assessment and monitoring, 4) assessment and monitoring of children and 5) assessment and monitoring of adults. Educational programmes varied in their purpose with respect to the types of patients being targeted, the health care workers being instructed, and the depth of pulse oximetry specific training.
CONCLUSIONS
Pulse oximetry training initiatives have been ongoing for decades for a variety of purposes, utilising a multitude of approaches to equip health care workers with tools to improve patient care. It is important that these initiatives continue as pulse oximetry availability and knowledge gaps remain. Neither pulse oximetry provision nor training alone is enough to bolster patient care, but sustainable solutions for both must be considered to meet the needs of both health care workers and patients.
Topics: Adult; Child; Female; Pregnancy; Humans; Developing Countries; Pandemics; COVID-19; Educational Status; Health Personnel
PubMed: 37736848
DOI: 10.7189/jogh.13.04074 -
BMC Pediatrics Oct 2023Bath is an external stimulus for preterm infants. Currently, three methods are used for preterm infants to bath. It is important to choose the best way for them. The... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Bath is an external stimulus for preterm infants. Currently, three methods are used for preterm infants to bath. It is important to choose the best way for them. The objective of this meta-analysis is to evaluate the effectiveness of different bath methods on physiological indexes and behavioral status of preterm infants.
METHODS
This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses [PRISMA] guidelines and was registered in PROSPERO(CRD42022377657). PubMed, Embase, Cochrane Library, Web of Science, CINAHL, Sino Med, China National Knowledge Internet (CNKI) and Wan-Fang database were systematically searched for randomized controlled trials on the effects of different bath methods for preterm infants. The retrieval time was from the establishment of the database to February 2023. According to the inclusion and exclusion criteria, the literature was screened, quality evaluated and the data was extracted. Reman Version 5.4 was used for meta-analysis and Stata 16.0 software for publication bias Egger's test.
RESULTS
A total of 11 RCTs with 828 preterm infants were included. The results of meta-analysis showed that the body temperature and oxygen saturation of preterm infants in the sponge bath group were lower than those in conventional tub bath group (SMD = -0.34; 95%CI -0.56 to -0.12; I = 0; p < 0.01), (MD = -0.39; 95%CI -0.76 to -0.02; I = 39%; p = 0.04), while the heart rates were higher than those in conventional tub bath group(MD = 5.90; 95%CI 0.44 to 11.35; I = 61%; p = 0.03). Preterm infant's body temperature and blood oxygen saturation of in swaddle bath group were higher than those in conventional tub bath group (MD = 0.18; 95%CI 0.05 to 0.30; I = 88%; p < 0.01), (MD = 1.11; 95%CI 0.07 to 2.16; I = 86%; p = 0.04), respiratory rates were more stable compared with infants in conventional tub bath group (MD = -2.73; 95%CI -3.43 to -2.03; I = 0; p < 0.01). The crying duration, stress and pain scores of preterm infants in swaddle bath group were lower than those in conventional tub bath group (SMD = -1.64; 95CI -2.47 to -0.82; I = 91%; p < 0.01), (SMD = -2.34; 95%CI -2.78 to -1.91; I = 0; p < 0.01), (SMD = -1.01; 95%CI -1.40 to -0.62; I = 49%; p < 0.01). Egger's test showed no publication bias in body temperature, respiratory rate, oxygen saturation, and crying duration.
CONCLUSIONS
Swaddle bath is the best bathing method than conventional tub bath and sponge bath in maintaining the stability of preterm infant's body temperature, blood oxygen saturation and respiratory rate. In addition, swaddle bath also plays a role in reducing cry duration, stress scores, and pain levels of preterm infant compared with conventional tub bath and sponge bath. However, due to the important heterogeneity in some outcomes, future studies with larger sample size and more appropriately design are needed to conduct before recommendation.
TRIAL REGISTRATION
Prospero CRD42022377657.
Topics: Infant; Infant, Newborn; Humans; Infant, Premature; Body Temperature; Crying; Oximetry; Pain
PubMed: 37828460
DOI: 10.1186/s12887-023-04280-y -
European Journal of Emergency Medicine... Aug 2023Carbon monoxide (CO) poisoning is one of the most common causes of poisoning death and its diagnosis requires an elevated carboxyhemoglobin (COHb) level. Noninvasive CO... (Meta-Analysis)
Meta-Analysis
Carbon monoxide (CO) poisoning is one of the most common causes of poisoning death and its diagnosis requires an elevated carboxyhemoglobin (COHb) level. Noninvasive CO saturation by pulse oximetry (SpCO) has been available since 2005 and has the advantage of being portable and easy to use, but its accuracy in determining blood COHb level is controversial. To evaluate the accuracy of SpCO (index test) to estimate COHb (reference test). Systematic review and meta-analysis of diagnostic test accuracy (DTA) studies. Four electronic databases were searched (Medline, Embase, Cochrane Central Register of Controlled Trials, and OpenGrey) on 2 August 2022. All studies of all designs published since the 2000s evaluating the accuracy and reliability of SpCO measurement compared to blood COHb levels in human volunteers or ill patients, including children, were included. The primary outcome was to assess the diagnostic accuracy of SpCO for estimating COHb by blood sampling by modeling receiver operating characteristic (ROC) curves and calculating sensitivity and specificity (primary measures). The secondary measures were to calculate the limits of agreement (LOA) and the mean bias. This systematic review was conducted according to the Preferred Reporting Items for a Systematic Review and Meta-analysis-DTA 2018 guidelines and has been registered on International Prospective Register of Systematic Reviews (PROSPERO, CRD42020177940). The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Twenty-one studies were eligible for the systematic review; 11 could be included for the quantitative analysis of the primary measures and 18 for the secondary measures. No publication bias was found. The area under the summary ROC curve was equal to 86%. The mean sensitivity and specificity were 0.77, 95% confidence interval (CI, 0.66-0.85) and 0.83, 95% CI (0.74-0.89), respectively (2089 subjects and 3381 observations). The mean bias was 0.75% and the LOA was -7.08% to 8.57%, 95% CI (-8.89 to 10.38) (2794 subjects and 4646 observations). Noninvasive measurement of COHb (SpCO) using current pulse CO oximeters do not seem to be highly accurate to estimate blood COHb (moderate sensitivity and specificity, large LOA). They should probably not be used to confirm (rule-in) or exclude (rule-out) CO poisoning with certainty.
Topics: Child; Humans; Carboxyhemoglobin; Reproducibility of Results; Oximetry; Carbon Monoxide Poisoning; Diagnostic Tests, Routine
PubMed: 37171830
DOI: 10.1097/MEJ.0000000000001043 -
PloS One 2023Recovery of cognitive and physiological responses following a hypoxic exposure may not be considered in various operational and research settings. Understanding recovery...
Recovery of cognitive and physiological responses following a hypoxic exposure may not be considered in various operational and research settings. Understanding recovery profiles and influential factors can guide post-hypoxia restrictions to reduce the risk of further cognitive and physiological deterioration, and the potential for incidents and accidents. We systematically evaluated the available evidence on recovery of cognitive and basic physiological responses following an acute hypoxic exposure to improve understanding of the performance and safety implications, and to inform post-hypoxia restrictions. This systematic review summarises 30 studies that document the recovery of either a cognitive or physiological index from an acute hypoxic exposure. Titles and abstracts from PubMed (MEDLINE) and Scopus were searched from inception to July 2022, of which 22 full text articles were considered eligible. An additional 8 articles from other sources were identified and also considered eligible. The overall quality of evidence was moderate (average Rosendal score, 58%) and there was a large range of hypoxic exposures. Heart rate, peripheral blood haemoglobin-oxygen saturation and heart rate variability typically normalised within seconds-to-minutes following return to normoxia or hyperoxia. Whereas, cognitive performance, blood pressure, cerebral tissue oxygenation, ventilation and electroencephalogram indices could persist for minutes-to-hours following a hypoxic exposure, and one study suggested regional cerebral tissue oxygenation requires up to 24 hours to recover. Full recovery of most cognitive and physiological indices, however, appear much sooner and typically within ~2-4 hours. Based on these findings, there is evidence to support a 'hypoxia hangover' and a need to implement restrictions following acute hypoxic exposures. The severity and duration of these restrictions is unclear but should consider the population, subsequent requirement for safety-critical tasks and hypoxic exposure.
Topics: Humans; Hypoxia; Oximetry; Respiration; Blood Pressure; Cognition
PubMed: 37585402
DOI: 10.1371/journal.pone.0289716 -
Sports Medicine (Auckland, N.Z.) Apr 2024In the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy...
BACKGROUND
In the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles.
OBJECTIVES
Considering the consistent number of studies on the application of muscle oximetry in sports science published over the last 5 years, the objectives of this updated systematic review were to highlight the applications of muscle oximetry in the assessment of skeletal muscle oxidative performance in sports activities and to emphasize how this technology has been applied to exercise and training over the last 5 years. In addition, some recent instrumental developments will be briefly summarized.
METHODS
Preferred Reporting Items for Systematic Reviews guidelines were followed in a systematic fashion to search, appraise and synthesize existing literature on this topic. Electronic databases such as Scopus, MEDLINE/PubMed and SPORTDiscus were searched from March 2017 up to March 2023. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programmes, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation.
RESULTS
Of the identified records, 191 studies regrouping 3435 participants, met the eligibility criteria. This systematic review highlighted a number of key findings in 37 domains of sport activities. Overall, NIRS information can be used as a meaningful marker of skeletal muscle oxidative capacity and can become one of the primary monitoring tools in practice in conjunction with, or in comparison with, heart rate or mechanical power indices in diverse exercise contexts and across different types of training and interventions.
CONCLUSIONS
Although the feasibility and success of the use of muscle oximetry in sports science is well documented, there is still a need for further instrumental development to overcome current instrumental limitations. Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
Topics: Humans; Oximetry; Muscle, Skeletal; Spectroscopy, Near-Infrared; Oxygen Consumption; Sports Medicine
PubMed: 38345731
DOI: 10.1007/s40279-023-01987-x -
Cureus Oct 2023Hemodynamic monitoring of neonates is crucial because neonates are easily and acutely susceptible to hemodynamic disturbances. As such, non-invasive monitoring of... (Review)
Review
Hemodynamic monitoring of neonates is crucial because neonates are easily and acutely susceptible to hemodynamic disturbances. As such, non-invasive monitoring of hemodynamics is preferable. It has been postulated that non-invasive pulse oximetry determines the perfusion index and pulse variability index and provides accurate measurements to predict hemodynamic changes in preterm or term infants. Equally, numerous studies have investigated the efficacy of perfusion and pulse variability indices in monitoring neonatal hemodynamics. The aim of this study was to systematically review studies that have delved into the role of perfusion and pulse variability indices in the assessment of neonatal hemodynamics. The study collected data from 2010-2023 using the patient, intervention, comparison, outcome (PICO) search strategy using the databases PubMed, Scopus, and Excerpta Medica database (Embase). A total of 616 articles were evaluated based on their appropriateness and relevance; we included seven studies. As per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we conducted a systematic review. Our study concluded that these indices were effective in measuring hemodynamics.
PubMed: 38046508
DOI: 10.7759/cureus.48058 -
Brazilian Oral Research 2023The main purpose of this study was to answer the question: "Can radiotherapy cause changes in the dental pulp condition of patients treated with irradiation in the head...
The main purpose of this study was to answer the question: "Can radiotherapy cause changes in the dental pulp condition of patients treated with irradiation in the head and neck region?" Clinical observational studies in adults with head and neck cancer undergoing treatment with ionizing radiation, longitudinal or cross-sectional follow-up to measure oxygen saturation (SpO2), and/or pulp sensitivity test to cold stimulation, were considered eligible. A systematic literature search was performed in six different databases, including the gray literature, and in article references. Two independent evaluators selected the studies, extracted the data, recorded the data on electronic spreadsheets, and then evaluated the methodological quality using the Checklist for Quasi-Experimental Studies tool devised by JBI. The data were assessed qualitatively using the Synthesis Without Metanalysis (SWiM) guidelines. After removing the duplicate articles, carefully analyzing the titles and abstracts, and reading the papers in full, seven studies were included. Four of the studies evaluated applied the cold sensitivity test, two associated pulse oximetry and cold sensitivity, and only one used just pulse oximetry. Evaluation using the cold sensitivity test and pulse oximetry in the initial periods before radiotherapy showed a decrease in the sensitive response and in SpO2 levels during a maximum period of 1 year. However, analyses thereafter indicated a normal response in both tests from 5 to 6 years after the end of radiotherapy treatment. Radiotherapy causes changes in pulp behavior patterns in the short term; however, recovery and return to average values occurs after long periods.
Topics: Adult; Humans; Cross-Sectional Studies; Head and Neck Neoplasms; Oximetry; Dental Pulp Diseases; Radiation, Ionizing; Dental Pulp
PubMed: 37531515
DOI: 10.1590/1807-3107bor-2023.vol37.0079 -
Medicina (Kaunas, Lithuania) Aug 2023Limited palatal muscle resection (PMR) is a surgical technique employed to alleviate respiratory disturbances in obstructive sleep apnea (OSA) patients with... (Meta-Analysis)
Meta-Analysis
Limited palatal muscle resection (PMR) is a surgical technique employed to alleviate respiratory disturbances in obstructive sleep apnea (OSA) patients with retropalatal narrowing by reducing soft palate volume and tightening the muscles. Although some previous publications have demonstrated the effectiveness of limited PMR, the overall efficacy and therapeutic role of limited PMR for the treatment of OSA remain uncertain. This study utilized meta-analysis and a systematic literature review to estimate the overall effectiveness of limited PMR in treating OSA. Multiple databases, including PubMed, EMBASE, Cochrane Library, and Web of Science, were searched using specific keywords related to OSA and limited PMR. Original articles assessing respiratory disturbances before and after limited PMR in patients with OSA were included. Data from selected articles were collected using standardized forms, including clinicodemographic characteristics, apnea-hypopnea index (AHI), and lowest pulse oximetry values (minimum SpO). Random effect models were used for analyzing significant heterogeneity. Egger's test and funnel plot were used to identify publication bias. Four studies were included in this meta-analysis for AHI, and three studies were included for minimum SpO during sleep. A significant reduction in the AHI and an increase in the minimum SpO were shown following limited PMR as the standardized mean difference (95% confidence interval) was 2.591 (1.092-4.090) and 1.217 (0.248-2.186), respectively. No publication bias was found in either analysis. The results of the meta-analysis and systemic review add to the literature that limited PMR can result in a reduction in the AHI and an increase in min SaO. In OSA patients with suspected retropalatal obstruction, limited PMR may be efficiently performed.
Topics: Humans; Databases, Factual; Palatal Muscles; Sleep; Sleep Apnea, Obstructive
PubMed: 37629722
DOI: 10.3390/medicina59081432 -
Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668