-
Aesthetic Plastic Surgery Oct 2023Upper eyelid blepharoplasty is a surgical procedure that aims to correct the typical changes that occur with aging to the periorbital area. The outcomes of this surgery... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Upper eyelid blepharoplasty is a surgical procedure that aims to correct the typical changes that occur with aging to the periorbital area. The outcomes of this surgery are aesthetic, as well as functional. Many studies have described an impact on the cornea, intraocular pressure, dry eye syndrome, and visual quality. The aim of this systematic review is to compare the different surgical techniques and their outcomes.
METHODS
The authors performed a literature review through online databases PubMed, Web of Science, Clinicaltrials.gov, and CENTRAL libraries. Information was collected about the surgery techniques and the functional and aesthetic outcomes as well as complications of the interventions. Six types of upper blepharoplasty surgery were studied. Data were analyzed using Cochrane RevMan.
RESULTS
Twenty studies were included in our systematic review and nine in our meta-analysis. We presented results about intraocular pressure, central corneal thickness, flattest keratometry, steepest keratometry, corneal astigmatism, visual acuity, Schirmer test 1 and 2, tear film break-up time and the ocular surface disease index questionnaire, according to type of surgery. Our meta-analysis showed no significant results.
CONCLUSIONS
No significant results were found; however, many studies reported an impact of upper blepharoplasty surgery in the outcomes studied. Only a small number of complications were reported, and patients were satisfied with the aesthetic outcomes.
LEVEL OF EVIDENCE III
This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://www.springer.com/00266 .
Topics: Humans; Blepharoplasty; Eyelids; Aging; Esthetics; Face; Retrospective Studies
PubMed: 37430010
DOI: 10.1007/s00266-023-03436-6 -
Scientific Reports Nov 2023To conduct a systematic review and meta-analysis of the association between children and adolescents with attention deficit hyperactivity disorder (ADHD) or autism... (Meta-Analysis)
Meta-Analysis
To conduct a systematic review and meta-analysis of the association between children and adolescents with attention deficit hyperactivity disorder (ADHD) or autism spectrum disorder (ASD) and ocular characteristics. Systematic review with meta-analysis. Six databases (PubMed, Scopus, APA PsycInfo, Embase, EBSCOhost, and Cochrane library) were selected for a systematic literature search from database inception to July 2022. The observational studies assessing and reporting at least one outcome regarding ocular characteristics in children and adolescents with ADHD or ASD aged 6-17 were included. Studies in languages other than English, studies of adult or elderly human populations, and animal studies were excluded. The results were analyzed following the PRISMA guideline 2020. The findings of 15 studies, including 433 participants with ADHD, 253 participants with ASD, and 514 participants with typical development (TD), revealed that there were no significant differences in retinal nerve fiber layer, ganglion cell complex, and macular thickness between the ADHD group and the TD group. In subgroup analysis, significant differences in inferior ganglion cell (MD = - 3.19; 95% CI = [- 6.06, - 0.31], p = 0.03) and nasal macular thickness (MD = 5.88; 95% CI = [- 0.01, 11.76], p = 0.05) were detected between the ADHD group and the TD group. A significant difference in pupillary light reflex (PLR) was also observed between the ASD group and the TD group (MD = 29.7; 95% CI = [18.79, 40.63], p < 0.001). Existing evidence suggests a possible association between children and adolescents with ADHD or ASD and ocular characteristics. Given the limited number of studies, further research on a larger cohort is necessary to claim a possible diagnosis of ADHD or ASD through ocular characteristics.
Topics: Adult; Animals; Aged; Adolescent; Child; Humans; Autism Spectrum Disorder; Face; Retina; Nose; Neurodevelopmental Disorders
PubMed: 37938638
DOI: 10.1038/s41598-023-46206-9 -
BMJ Open Ophthalmology Nov 2023To explore the current research about the role of optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA) in dysthyroid optic neuropathy... (Meta-Analysis)
Meta-Analysis
PURPOSE
To explore the current research about the role of optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA) in dysthyroid optic neuropathy (DON).
METHODS
Studies in the literature that focused on OCT, OCTA and DON were retrieved by searching PubMed, EMBASE, Cochrane databases and Clinical Trial before 20 June 2023. The methodological quality was assessed using the Newcastle-Ottawa scale. The quantitative calculation was performed using Review Manager V.5.3.
RESULTS
Twelve studies met the eligibility criteria and were included. DON group presented lower macular ganglion cell complex in the overall, superior and inferior hemifields compared with the non-DON group. Furthermore, the ganglion cell layer and inner plexiform layer in DON group was thinner in contrast to the non-DON group. The optic nerve head vessel density was lower in the DON group than that in the non-DON group. A reduction of radial peripapillary capillary vessel density could be seen in the DON group than the non-DON group in overall, inside disc, peripapillary, superior-hemifield, temporal and nasal. Besides, the macular superficial retinal capillary layer of non-DON and DON is lower than the healthy control group.
CONCLUSIONS
This study supported the potential value of OCT and OCTA metrics as novel biomarkers of DON. Ophthalmologists should comprehensively consider the retinal structure and microvasculature in dealing with DON.
ETHICS AND DISSEMINATION
This systematic review included data from published literature and was exempt from ethics approval. Results would be disseminated through peer-reviewed publication and presented at academic conferences engaging clinicians.
PROSPERO REGISTRATION NUMBER
CRD42023414907.
Topics: Humans; Tomography, Optical Coherence; Optic Disk; Angiography; Retinal Ganglion Cells; Optic Nerve Diseases
PubMed: 37996119
DOI: 10.1136/bmjophth-2023-001379 -
Surgical Endoscopy May 2024Ultrasound has been nicknamed "the surgeon's stethoscope". The advantages of laparoscopic ultrasound beyond a substitute for the sense of touch are considerable,... (Review)
Review
INTRODUCTION
Ultrasound has been nicknamed "the surgeon's stethoscope". The advantages of laparoscopic ultrasound beyond a substitute for the sense of touch are considerable, especially for robotic surgery. Being able to see through parenchyma and into vascular structures enables to avoid unnecessary dissection by providing a thorough assessment at every stage without the need for contrast media or ionising radiation. The limitations of restricted angulation and access within the abdominal cavity during laparoscopy can be overcome by robotic handling of miniaturised ultrasound probes and the use of various and specific frequencies will meet tissue- and organ-specific characteristics. The aim of this systematic review was to assess the reported applications of intraoperative ultrasound-guided robotic surgery and to outline future perspectives.
METHODS
The study adhered to the PRISMA guidelines. PubMed, Google Scholar, ScienceDirect and ClinicalTrials.gov were searched up to October 2023. Manuscripts reporting data on ultrasound-guided robotic procedures were included in the qualitative analysis.
RESULTS
20 studies met the inclusion criteria. The majority (53%) were related to the field of general surgery during liver, pancreas, spleen, gallbladder/bile duct, vascular and rectal surgery. This was followed by other fields of oncological surgery (42%) including urology, lung surgery, and retroperitoneal lymphadenectomy for metastases. Among the studies, ten (53%) focused on locating tumoral lesions and defining resection margins, four (15%) were designed to test the feasibility of robotic ultrasound-guided surgery, while two (10.5%) aimed to compare robotic and laparoscopic ultrasound probes. Additionally two studies (10.5%) evaluated the robotic drop-in probe one (5%) assessed the hepatic tissue consistency and another one (5%) aimed to visualize the blood flow in the splenic artery.
CONCLUSION
The advantages of robotic instrumentation, including ergonomics, dexterity, and precision of movements, are of relevance for robotic intraoperative ultrasound (RIOUS). The present systematic review demonstrates the virtue of RIOUS to support surgeons and potentially reduce minimally invasive procedure times.
Topics: Robotic Surgical Procedures; Humans; Ultrasonography, Interventional; Laparoscopy
PubMed: 38512350
DOI: 10.1007/s00464-024-10772-4 -
International Ophthalmology Jun 2024This meta-analysis reviews the evidence for the risks and benefits associated with orthokeratology (OK) treatment compared with other methods of myopia control in... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
This meta-analysis reviews the evidence for the risks and benefits associated with orthokeratology (OK) treatment compared with other methods of myopia control in children and adults.
METHODS
A systematic search of Cochrane Central Register of Controlled Trials, Pubmed, Embase and Ovid was conducted from database inception to 22nd August 2021. Studies that reported on risks, visual and ocular biometric effects of OK in patients > 5 years of age with myopia (- 0.75 to - 6.00D) were included. Main outcomes are change in axial length and any adverse event.
RESULTS
Fourty-five papers were included in this systematic review and meta-analysis. The quality of data was variable and of moderate certainty, and selection bias likely skewed the results towards a relative benefit for OK. The rate of axial elongation in children was lower for OK treatment compared to other treatment modalities at one year (MD - 0.16 mm, 95% CI - 0.25 to - 0.07). Rate of change in axial length in children rebounded after OK discontinuation compared to participants who continued treatment (MD 0.10 mm, 95% CI 0.06 to 0.14). Adults and children wearing OK were up to 3.79 times more likely to experience an adverse event when compared with conventional contact lenses (OR 3.79, 95% CI 1.24 to ll.), though this evidence base is underdeveloped and requires additional well-designed studies for substantial conclusions to be drawn.
CONCLUSIONS
OK arrests myopia progression while in use, however, there remain unanswered questions about the optimal duration of treatment, discontinuation effects and long-term risk for adverse events.
Topics: Humans; Orthokeratologic Procedures; Myopia; Refraction, Ocular; Visual Acuity; Axial Length, Eye; Contact Lenses; Child; Risk Assessment
PubMed: 38904856
DOI: 10.1007/s10792-024-03175-w -
BMC Ophthalmology Nov 2023Refractive errors are one of the most common ocular conditions among children and adolescents, with myopia showing an increasing prevalence and early onset in this... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Refractive errors are one of the most common ocular conditions among children and adolescents, with myopia showing an increasing prevalence and early onset in this population. Recent studies have identified a correlation between refractive errors and ocular biometric parameters.
METHODS
A systematic search was conducted in electronic databases including PubMed, EMBASE, Cochrane Library, Web of Science, and Medline from January 1, 2012, to May 1, 2023. Various ocular biometric parameters were summarized under different refractive states, including axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), corneal curvature (CC), Corneal curvature radius (CR),axial length-to-corneal radius ratio (AL/CR ratio), choroidal thickness (ChT), retinal thickness (RT), retinal nerve fiber layer thickness (RNFL), and retinal blood density (VD). The differences in these parameters among different refractive states were analyzed using Stata software with fixed or random-effects models, taking into account the assessed heterogeneity level.
RESULTS
This meta-analysis included a total of 69 studies involving 128,178 eyes, including 48,795 emmetropic eyes, 60,691 myopic eyes, 13,983 hyperopic eyes, 2,040 low myopic eyes, 1,201 moderate myopic eyes, and 1,468 high myopic eyes. The results of our study demonstrated that, compared to the control group (emmetropic group), the myopic group and low, moderate, and high myopic groups showed significant increases in AL, AL/CR ratio, and ACD, while the hyperopic group exhibited significant decreases. Compared to the control group, the myopic group had a significantly increase for CC, while CR, CCT, perifoveal RT, subfoveal ChT, foveal ChT, parafoveal ChT, perifoveal (except nasal) ChT, and pRNFL (except temporal) significantly decreased. Compared to the control group, the hyperopic group had a significantly increase for subfoveal ChT, foveal ChT, parafoveal ChT, perifoveal ChT, and nasal pRNFL. Compared to the control group, the low and moderate myopic groups had a significantly decreases for the CCT, parafoveal RT (except nasal), perifoveal RT (except nasal), and pRNFL (except superior and temporal). Compared to the control group, the high myopic group had a significantly increase for CR, while LT, perifoveal ChT (except nasal), parafoveal RT, perifoveal RT, and pRNFL (except temporal) had significant decreased.
CONCLUSION
The changes of ocular biometric parameters in children and adolescents are closely related to refractive errors. Ocular biometric parameters devices, as effective non-invasive techniques, provide objective biological markers for monitoring refractive errors such as myopia.
Topics: Humans; Child; Adolescent; Tomography, Optical Coherence; Refractive Errors; Myopia; Retina; Refraction, Ocular; Hyperopia; Biometry
PubMed: 37990308
DOI: 10.1186/s12886-023-03222-7 -
Journal of Clinical Medicine Oct 2023This PRISMA-compliant systematic review aimed to investigate the use of and the most common procedures performed with the novel 3D 4K exoscope in surgical pediatric head... (Review)
Review
UNLABELLED
This PRISMA-compliant systematic review aimed to investigate the use of and the most common procedures performed with the novel 3D 4K exoscope in surgical pediatric head and neck settings.
METHODS
Search criteria were applied to PubMed, EMBASE and the Cochrane Review databases and included all studies published up to January 2023 reporting 3D 4K exoscope-assisted surgeries in pediatric patients. After the removal of duplicates, selection of abstracts and full-text articles, and quality assessment, we reviewed eligible articles for number of patients treated, age, surgical procedures, and outcomes.
RESULTS
Among 54 potentially relevant records, 5 studies were considered eligible and included in this systematic review, with reported treatment data for 182 patients. The surgical procedures belong to the otologic field (121 cases), head and neck surgery (25 cases) and transoral surgery (36 cases). Exoscopy allowed high quality visualization of anatomical structures during cochlear implantation and during reconstruction in head and neck surgery; moreover, it improved the surgical view of surgeons, spectators and ENT students.
CONCLUSIONS
The use of 3D 4K exoscopy has shown promising potential as a valuable tool in pediatric ORL-head and neck surgery; nevertheless, further validation of these encouraging outcomes is necessary through larger-scale studies specifically focused on pediatric patients.
PubMed: 37892666
DOI: 10.3390/jcm12206528 -
Experimental Eye Research Sep 2023Animal models of choroidal neovascularization (CNV) are extensively used in translational studies of CNV formation and to evaluate angiostatic treatment strategies.... (Review)
Review
Animal models of choroidal neovascularization (CNV) are extensively used in translational studies of CNV formation and to evaluate angiostatic treatment strategies. However, the current paucity of large animal models compared with rodent models constitutes a knowledge gap regarding the clinical translation of findings. Ocular anatomical and physiological similarities to humans suggest the pig as a relevant model animal. Thus, a systematic survey of porcine CNV models was performed to identify pertinent model parameters and suggest avenues for model standardization and optimization. A systematic search was performed in PubMed and EMBASE on November 28, 2022 for porcine models of CNV. Following inclusion by two investigators, data from the articles were extracted according to a predefined protocol. A total of 14 articles, representing 19 independent porcine CNV models were included. The included models were almost equally divided between laser-induced (53%) and surgically-induced (47%) models. Different specified breeds of domestic pigs (71%) were most commonly used in the studies. All studies used normal animals. Female pigs were reported used in 43% of the studies, while 43% did not report on sex of the animals. Younger pigs were typically used. The surgical models reported consistent CNV induction following mechanical Bruch's membrane rupture. The laser models used variants of the infrared diode laser (40%) or the frequency-doubled Nd:YAG laser (50%). Both lasers enabled successful CNV induction with reported induction rates ranging from 60 to 100%. Collateral damage to the neuroretina was reported for the infrared diode laser. CNV evaluation varied across studies with fluorescein angiography (50%) as the most used in vivo method and retinal sections (71%) as the most used ex vivo method. In interventional studies, quantification of lesions was in general performed between 7 and 14 days. The field of porcine CNV models is relatively small and heterogeneous and almost equally divided between surgically-induced and laser-induced models. Both methods have allowed successful modeling of CNV formation with induction rates comparable to those of non-human primates. However, the field would benefit from standardization of model parameters and reporting. This includes laser parameters and validation of CNV formation as well as methods of CNV evaluation and statistical analysis.
Topics: Female; Humans; Swine; Animals; Disease Models, Animal; Choroidal Neovascularization; Retina; Bruch Membrane; Fluorescein Angiography
PubMed: 37474015
DOI: 10.1016/j.exer.2023.109590 -
Medicine Aug 2023Small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) have been extensively studied as the main surgical methods for... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) have been extensively studied as the main surgical methods for corneal refractive surgery. However, there is no consensus on whether SMILE is superior to FS-LASIK in corneal biomechanics. Therefore, this systematic review and meta-analysis used the results of ocular response analyzer and corvis ST to explore whether SMILE is superior to FS-LASIK in corneal biomechanics.
METHODS
The literature was searched in PubMed, EMBASE, and Controlled Trials Register databases. The Cochrane Collaboration's "risk of bias" tool was used to evaluate the quality of the included randomized clinical trials, and the Newcastle-Ottawa Scale was used to evaluate the included non-randomized controlled trials. The results were analyzed using Revman 5.3.
RESULTS
Sixteen studies (3 randomized clinical trials and 13 non-randomized controlled trials) were included in this meta-analysis. There was no statistical difference in corneal biomechanics between SMILE and FS-LASIK in corneal hysteresis [mean difference (MD), 0.20; 95% confidence interval (CI): -0.09, 0.49; P = .18] and corneal resistant factor (MD, 0.31; 95% CI: -0.09, 0.71; P = .13), A1 time (MD, -0.02; 95% CI: -0.11, 0.07; P = .66), A1 length (MD, 0.01; 95% CI: -0.01, 0.03; P = .42), A1 velocity (MD, 0.00; 95% CI: -0.01, 0.01; P = .85), A2 velocity (MD, -0.01; 95% CI: -0.11, 0.09; P = .86), HC time (MD, 0.12; 95% CI: -0.13, 0.38; P = .35), The stiffness parameter at first applanation (MD, -7.91; 95% CI: -17.96, 2.14; P = .12), The ratio between the deformation amplitude 2 mm away from apex and the apical deformation (MD, 0.01; 95% CI: -0.26, 0.27; P = .96).
CONCLUSION
A comprehensive assessment of the parameters of ocular response analyzer and corvis ST showed that SMILE is not superior to LASIK in corneal biomechanics 3 months post-surgery.
Topics: Humans; Keratomileusis, Laser In Situ; Biomechanical Phenomena; Myopia; Cornea; Prospective Studies; Surgical Wound; Corneal Stroma
PubMed: 37565903
DOI: 10.1097/MD.0000000000034580 -
Experimental Brain Research Sep 2023Ocular microtremor (OMT) is the smallest of three involuntary fixational micro eye movements, which has led to it being under researched in comparison. The link between...
Ocular microtremor (OMT) is the smallest of three involuntary fixational micro eye movements, which has led to it being under researched in comparison. The link between OMT and brain function generates a strong rationale for further study as there is potential for its use as a biomarker in populations with neurological injury and disease. This structured review focused on populations previously studied, instrumentation used for measurement, commonly reported OMT outcomes, and recommendations concerning protocol design and future studies. Current methods of quantifying OMT will be reviewed to analyze their efficacy and efficiency and guide potential development and understanding of novel techniques. Electronic databases were systematically searched and compared with predetermined inclusion criteria. 216 articles were identified in the search and screened by two reviewers. 16 articles were included for review. Findings showed that piezoelectric probe is the most common method of measuring OMT, with fewer studies involving non-invasive approaches, such as contact lenses and laser imaging. OMT frequency was seen to be reduced during general anesthesia at loss of consciousness and in neurologically impaired participants when compared to healthy adults. We identified the need for a non-invasive technique for measuring OMT and highlight its potential in clinical applications as an objective biomarker for neurological assessments. We highlight the need for further research on the clinical validation of OMT to establish its potential to identify or predict a meaningful clinical or functional state, specifically, regarding accuracy, precision, and reliability of OMT.
Topics: Adult; Humans; Consciousness; Eye; Face; Reproducibility of Results
PubMed: 37632535
DOI: 10.1007/s00221-023-06691-w