-
International Journal of Nursing Studies Jan 2024Central venous catheters are commonly used in healthcare, but they come with a range of potential complications. Over the last 15 years, an influx of securement and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Central venous catheters are commonly used in healthcare, but they come with a range of potential complications. Over the last 15 years, an influx of securement and dressing products has been released, with unknown overall effectiveness to prevent these complications.
OBJECTIVE
To compare the effects of dressings and securement devices for central venous catheters on a range of common complications including catheter-related bloodstream infection, catheter tip colonisation, entry/exit-site infection, skin colonisation, skin irritation, failed catheter securement, dressing durability and mortality.
DESIGN
Systematic review with meta-analysis.
METHODS
Following standard Cochrane methods, a systematic search of Cochrane Wounds Trials Register, Cochrane Central Register of Controlled Trials, MEDLINE Ovid, Embase Ovid, EBSCO CINAHL, and multiple clinical trial registries was completed in November 2022. Randomised controlled trials evaluating the effectiveness of dressing and securement devices for all CVC types were included. A random-effects model was used during the meta-analysis. Results were expressed using risk ratio (RR), rate ratio, or mean difference (MD), with 95 % confidence intervals (CIs). Methodological quality and bias were assessed.
RESULTS
We included 46 studies involving 10,054 participants. All studies had either an unclear or high-performance bias. The blinding of outcome assessment was unclear in most studies. Chlorhexidine gluconate-impregnated dressings, compared with standard polyurethane dressings, may reduce the incidence (7 studies; N = 5816; RR 0.60, 95 % CI 0.44-0.83; low certainty evidence) and rate (4 studies; N = 4447; RR 0.51, 95 % CI 0.32-0.79; moderate certainty evidence) of catheter-related bloodstream infection and catheter tip colonisation (8 studies; N = 4788; RR 0.70, 95 % CI 0.52-0.95; very low certainty evidence). Medication-impregnated dressings may reduce the incidence of catheter-related bloodstream infection (6 studies; N = 5687; RR 0.60, 95 % CI 0.39-0.93; low certainty evidence) and catheter-tip colonisation (7 studies; N = 4769; RR 0.60, 95 % CI 0.47-0.76; low certainty evidence) relative to non-impregnated dressing types. Tissue adhesive may increase the risk of skin irritation or damage compared with integrated securement dressings (3 studies; N = 166; RR 1.88, 95 % CI 1.09-3.24; low certainty evidence) or sutureless securement devices (4 studies; N = 241; RR 1.64, 95 % CI 1.10-2.44; moderate certainty evidence). Tissue adhesive increased dressing durability compared with integrated securement dressings (MD 43.03 h, 95 % CI 4.88-81.18; moderate certainty evidence) and sutureless securement devices (MD 42.90 h, 4.64-81.16; moderate certainty evidence). Tissue adhesive increased failed catheter securement rate compared with suture (2 studies; N = 103; RR 9.33, 95 % CI 1.10-79.21; moderate certainty evidence).
CONCLUSIONS
The findings of the review provide insights and guidance for clinicians in selecting the appropriate dressings and securements for catheters. Findings should be interpreted with caution due to heterogeneity in catheters and patient types.
REGISTRATION
#CD010367.
TWEETABLE ABSTRACT
Time to implement chlorhexidine gluconate-impregnated dressings to prevent catheter-related bloodstream infections; a meta-analysis by @GraceNP and team.
Topics: Humans; Central Venous Catheters; Tissue Adhesives; Bandages; Sepsis
PubMed: 37879273
DOI: 10.1016/j.ijnurstu.2023.104620 -
Orthopaedic Journal of Sports Medicine Oct 2023Glenohumeral dislocations often lead to glenoid bone loss and recurrent instability, warranting bony augmentation. While numerous biomechanical studies have investigated... (Review)
Review
BACKGROUND
Glenohumeral dislocations often lead to glenoid bone loss and recurrent instability, warranting bony augmentation. While numerous biomechanical studies have investigated fixation methods to secure a graft to the glenoid, a review of available constructs has yet to be performed.
PURPOSE
To synthesize the literature and compare the biomechanics of screw and suture button constructs for anterior glenoid bony augmentation.
STUDY DESIGN
Systematic review.
METHODS
A systematic review was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. There were 2 independent reviewers who performed a literature search using the PubMed, Embase, and Google Scholar databases of studies published between 1950 and 2020. Studies were included that compared the biomechanical outcomes of fixation for the treatment of anterior shoulder instability with glenoid bone loss.
RESULTS
Overall, 13 of the 363 studies screened met the inclusion criteria. The included studies measured the biomechanical strength of screws or suture buttons on a cadaveric or synthetic Latarjet construct. Screws and suture buttons were biomechanically similar, as both constructs exhibited comparable loads at failure and final displacement. Screw type (diameter, threading, or composition) did not significantly affect construct strength, and double-screw fixation was superior to single-screw fixation. Additionally, 2 screws augmented with a small plate had a higher load at failure than screws that were not augmented. Unicortical double-screw fixation was inferior to bicortical double-screw fixation, although construct strength did not significantly decrease if 1 of these screws was unicortical. Further, 2 screws inserted at 15° off axis experienced significantly higher graft displacement and lower ultimate failure loads than those inserted at 0° parallel to the glenoid.
CONCLUSION
Suture buttons provided comparable strength to screws and offer an effective alternative to reduce screw-related complications. Augmentation with a small plate may clinically enhance construct strength and decrease complications through the dispersion of force loads over a greater surface area. Differences in screw type did not appear to alter construct strength, provided that screws were placed parallel to the articular surface and were bicortical.
PubMed: 37840899
DOI: 10.1177/23259671231186429 -
Acta Obstetricia Et Gynecologica... Dec 2023Iatrogenic bladder injury is a rare complication following obstetric and gynecologic surgery and only sparse information is available regarding length of transurethral... (Meta-Analysis)
Meta-Analysis Review
INTRODUCTION
Iatrogenic bladder injury is a rare complication following obstetric and gynecologic surgery and only sparse information is available regarding length of transurethral catheterization following injuries, suturing techniques including choice of suture, and complications. The primary aim of this systematic review was to evaluate length of transurethral catheterization in relation to complications following iatrogenic bladder injury. Second, we aimed to evaluate the number of complications following repair of iatrogenic bladder injuries and to describe suture technique and best choice of suture.
MATERIAL AND METHODS
A systematic review and meta-analysis was conducted, and the results were presented in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. PubMed, Embase, and Medline electronic databases were searched, and followed by screening from two independent reviewers. Studies published between January 2000 and March 2023 describing methods of bladder injury repair following obstetric or gynecologic benign surgery were included. Data extraction was done using Covidence. We performed a meta-analysis on complications after repair and explored this with a meta-regression analysis (Metafor package R) on length of catheterization to determine if length of catheterization influenced the risk of complication. A risk of bias tool from Cochrane was used to assess risk of bias and the study was registered in PROSPERO (CRD42021290586).
RESULTS
Out of 2175 articles, we included 21 retrospective studies, four prospective studies, and one case-control study. In total, 595 bladder injuries were included. Cesarean section was the most prominent surgery type, followed by laparoscopically assisted vaginal hysterectomy. We found no statistically significant association between length of transurethral catheterization and numbers of complications following repair of iatrogenic bladder injuries. More than 90% of injuries were recognized intraoperatively. Approximately 1% had complications following iatrogenic bladder injury repair (0.010, 95% confidence interval 0.0015-0.0189, 26 studies, 595 participants, I = 4%).
CONCLUSIONS
Our review did not identify conclusive evidence on the length of postoperative catheterization following bladder injury warranting further research. However, the rate of complications was low following iatrogenic bladder injury with a wide range of repair approaches.
Topics: Female; Humans; Pregnancy; Urinary Bladder; Cesarean Section; Retrospective Studies; Case-Control Studies; Prospective Studies; Urinary Bladder Diseases; Obstetric Surgical Procedures; Iatrogenic Disease
PubMed: 37552010
DOI: 10.1111/aogs.14641 -
Journal of Clinical Medicine Aug 2023True acromioclavicular joint (ACJ) injuries are rare in children and adolescents due to the strength of ligaments in this age group. However, a standardized management... (Review)
Review
True acromioclavicular joint (ACJ) injuries are rare in children and adolescents due to the strength of ligaments in this age group. However, a standardized management guideline for these injuries is currently lacking in the literature. This systematic review aims to provide an organized overview of associated injuries and propose a management algorithm for pediatric ACJ injuries. Using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, a systematic review was conducted. Two independent observers searched PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), and Scopus databases for ACJ injuries in children and adolescents. The extracted data were analyzed (due to the limited number of publications and inhomogeneity of data, no formal statistical analysis was conducted), and cases were categorized based on injury frequency and pattern, leading to the formulation of a treatment algorithm. The risk of bias was assessed using the Joanna Briggs Institute (JBI) critical appraisal checklist. A total of 77 articles were identified, and 16 articles (4 case series and 12 case reports) met the inclusion criteria. This study included 37 cases in 36 patients (32 males, 4 females) with a mean age of 13 years (9-17 years). Six injury categories were described. Surgical management was performed in 27 ACJ injuries (25 open, 2 arthroscopic). Various surgical implants were used including K wires, polydioxanone sutures (PDS), screws, hook plates, suture anchors, and suture button devices. Most cases achieved good to excellent outcomes, except for one case of voluntary atraumatic dislocation of the ACJ. This systematic review provides the first comprehensive analysis of ACJ injury management in adolescents with open physis. It categorizes injury patterns and presents a treatment algorithm to enhance the understanding of these injuries. The review's findings contribute valuable insights for clinicians dealing with pediatric ACJ injuries.
PubMed: 37685716
DOI: 10.3390/jcm12175650 -
Annals of Translational Medicine Aug 2023Suture button fixation of syndesmotic injuries allows for more physiologic motion of the ankle joint while maintaining adequate reduction and may avoid the need for...
BACKGROUND
Suture button fixation of syndesmotic injuries allows for more physiologic motion of the ankle joint while maintaining adequate reduction and may avoid the need for additional surgeries, given the lower risk of syndesmotic diastasis and implant failure. Few studies have examined the optimal number and configuration of suture buttons for syndesmotic disruption. The purpose of this systematic review and meta-analysis is to compare different suture button configurations from the cadaveric literature and to assess their relative effect on the stability of the syndesmotic reduction and functional movement of the ankle.
METHODS
A literature search in the databases MEDLINE via PubMed, Embase via Elsevier, Scopus via Elsevier, and SPORTDiscus via EBSCO were searched through December 2022 to identify studies related to cadaveric modeling of the syndesmosis. Only cadaveric studies with suture button fixation and studies in English were included. The quality of cadaveric studies was assessed using the Quality Assessment for Cadaveric Studies (QUACS) tool. Revman 5.3 software was used to perform the meta-analysis.
RESULTS
The meta-analysis included 5 studies and 86 limbs. The systematic review included 15 studies. When comparing single and double suture button configurations, no difference was found between groups with regard to fibular rotation (MD =-0.9; 95% CI: -2.09 to 0.27; I=79%; P=0.13) and both groups had similar rotational stability. The double suture button technique did demonstrate less sagittal fibular translation compared to the single suture button (MD =0.48; 95% CI: 0.02-0.94; I=66%; P=0.04). When comparing two suture buttons in parallel and divergent configurations, studies did not find any differences with regard to strength or stability.
CONCLUSIONS
There were no significant differences in biomechanical parameters when comparing single and double suture button constructs. While single button suture constructs result in minimal fibular rotation, double suture button constructs minimize fibular translation. This review may serve as a guide for clinicians when approaching these injuries.
PubMed: 37675292
DOI: 10.21037/atm-23-1527 -
Orthopaedic Journal of Sports Medicine Aug 2023Flexible ligamentous fixation has increased in popularity for the treatment of ligamentous Lisfranc injury, but the optimal fixation strategy is unclear. (Review)
Review
BACKGROUND
Flexible ligamentous fixation has increased in popularity for the treatment of ligamentous Lisfranc injury, but the optimal fixation strategy is unclear.
PURPOSE
To review the biomechanical, clinical, and radiographic results of ligamentous Lisfranc injuries treated with flexible fixation.
STUDY DESIGN
Systematic review; Level of evidence, 4.
METHODS
A systematic literature review was conducted according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The PubMed/Medline and Google Scholar literature databases were queried for clinical and biomechanical (cadaveric) studies relating to flexible fixation of ligamentous Lisfranc injury. Outcomes of interest included patient-reported outcome scores, clinical/biomechanical results, radiographic alignment, and return to activity. Where appropriate, meta-analysis of the postoperative outcomes was performed.
RESULTS
Of the 34 initial studies, 14 articles (243 feet) were included in the analysis. In the 11 clinical studies (216 patients), the mean postoperative American Orthopaedic Foot & Ankle Society score was 90.1 (n = 150; 6 studies) and the mean visual analog scale score was 1.5 (n = 137; 5 studies). The rate of return to activity was 100% (n = 35; 5 studies), and 100% of patients maintained radiographic alignment postoperatively (n = 62; 6 studies). No complications or subsequent hardware removals were reported. Of the 3 biomechanical studies (27 feet), 1 study found significantly greater change in diastasis under axial load between intact and postfixation ligaments with suture button versus screw fixation (+1.1 vs -0.1 mm; < .05), another found no difference in the decrease in diastasis under axial load between the injured state and screw or suture button fixation (1.2 vs 1.0 mm; = .5), and the third found no difference in displacement between intact and either screw or suture button fixation under either axial (intact vs screw: 1.0 vs 2.0 mm, = .1; intact vs suture button: 0.6 vs 1.8 mm, = .1) or abduction (intact vs screw: 1.5 vs 1.1 mm, = .5; intact vs suture button: 1.3 vs 2.1 mm, = .1) load.
CONCLUSION
Flexible fixation use in the treatment of ligamentous Lisfranc injury was found to have significant potential as a fixation option, as demonstrated by excellent clinical results. Biomechanical evidence was inconclusive but suggested a trend toward decreased diastasis in specimens fixed with screws compared with suture buttons.
PubMed: 37538534
DOI: 10.1177/23259671231186387 -
Cureus Jul 2023Ramp lesions are a common occurrence in patients with anterior cruciate ligament (ACL) tears. These lesions can be difficult to diagnose due to their concealed nature,... (Review)
Review
Ramp lesions are a common occurrence in patients with anterior cruciate ligament (ACL) tears. These lesions can be difficult to diagnose due to their concealed nature, and their treatment is crucial due to the stabilizing function of the medial meniscocapsular region. The optimal treatment option for ramp lesions varies depending on the size and stability of the lesion. The purpose of this study was to evaluate the best treatment option for ramp lesions based on the stability of the lesion, including no treatment, biological treatment, and arthroscopic repair. We hypothesize that stable lesions have a favorable prognosis with techniques that do not require the use of meniscal sutures. In contrast, unstable lesions require appropriate fixation, either through an anterior or posteromedial portal. This study is a systematic review and meta-analysis with a level of evidence IV. The study used Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for a systematic review of clinical studies reporting outcomes of ramp lesion treatment. The PubMed/MEDLINE database was searched using Mesh and non-Mesh terms related to ramp lesions, medial meniscus ramp lesions, and meniscocapsular injuries. The inclusion criteria encompassed clinical studies in English or Spanish that reported the treatment of ramp meniscal lesions, with a follow-up of at least six months and inclusion of functional results, clinical stability tests, radiological evaluation, or arthroscopic second look. The analysis included 13 studies with 1614 patients. Five studies distinguished between stable and unstable ramp lesions using different criteria (displacement or size) for assessment. Of the stable lesions, 90 cases received no treatment, 64 cases were treated biologically (debridement, edge-curettage, or trephination), and 728 lesions were repaired. There were 221 repaired unstable lesions. All different methods of repair were registered. In stable lesions, three studies were included in a network meta-analysis. The best-estimated treatment for stable lesions was biological (SUCRA 0.9), followed by repair (SUCRA 0.6), and no treatment (SUCRA 0). In unstable lesions, seven studies using International Knee Documentation Committee Subjective Knee Form (IKDC) and 10 studies using Lysholm for functional outcomes showed significant improvement from preoperative to postoperative scores after repair, with no differences between repairing methods. We recommend simplifying the classification of ramp lesions as stable or unstable to determine treatment. Biological treatment is preferred for stable lesions rather than leaving them in situ. Unstable lesions, on the other hand, require repair, which has been associated with excellent functional outcomes and healing rates.
PubMed: 37435014
DOI: 10.7759/cureus.41651 -
Journal of Clinical Medicine Aug 2023Women with bladder endometriosis often present with more advanced stages of endometriosis. Robotic surgery has emerged as a promising approach to the management of... (Review)
Review
INTRODUCTION
Women with bladder endometriosis often present with more advanced stages of endometriosis. Robotic surgery has emerged as a promising approach to the management of bladder endometriosis. This systematic review aims to analyze the current literature on robotic surgery for bladder endometriosis and describe our systematic approach to surgical treatment.
METHODS
This review followed the PRISMA guidelines, which ensured a comprehensive and transparent approach to selecting and evaluating relevant studies. We conducted a thorough literature search to identify studies that investigated the use of robotic surgery for bladder endometriosis. Relevant databases were searched, and inclusion and exclusion criteria were applied to select eligible studies. Data extraction and analysis were performed to assess the outcomes and effectiveness of robotic surgery for the treatment of bladder endometriosis.
RESULTS
We did not find any randomized clinical trials with the use of robotics in the treatment of bladder endometriosis. We found only two retrospective studies comparing robotic surgery with laparoscopy, and another retrospective study comparing robotic surgery, laparoscopy, and laparotomy in the treatment of bladder endometriosis. All the other 12 studies were solely case reports. Despite the lack of robust evidence in the literature, the studies demonstrated that robotic surgery is feasible and is associated with reduced postoperative pain, shorter hospital stays, and faster recovery.
CONCLUSIONS
The utilization of robotic technology is a promising option for the surgical management of bladder endometriosis. We advocate a surgical systematic approach for the robotic treatment of bladder endometriosis. Robotic technology, with its 3D vision, instrumental degrees of freedom, and precision, particularly in suturing, may provide potential benefits over traditional laparoscopy.
PubMed: 37629459
DOI: 10.3390/jcm12165416 -
Arthroscopy, Sports Medicine, and... Oct 2023To review the Kerlan-Jobe Orthopaedic Clinic (KJOC) scores, return-to-play rates, and complications after ulnar collateral ligament (UCL) repair with suture augmentation. (Review)
Review
Elbow Ulnar Collateral Ligament Repair With Suture Augmentation Results in Good Clinical Results, a Return-to-Play Rate Between 67% and 93%, and a Postoperative Complication Rate Up to 11.9%: A Systematic Review.
PURPOSE
To review the Kerlan-Jobe Orthopaedic Clinic (KJOC) scores, return-to-play rates, and complications after ulnar collateral ligament (UCL) repair with suture augmentation.
METHODS
A literature search of the PubMed and Scopus databases was conducted on February 17, 2023, using the terms "ulnar collateral ligament," "repair," "internal brace," and "suture augmentation." The search strategy was based on the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) protocol and included 4 articles published from 2019 to 2022. The inclusion criteria included studies reporting outcomes, return-to-play rates, and/or complications after UCL repair with suture augmentation. The exclusion criteria consisted of non-English language studies, case reports, cadaveric studies, animal studies, letters to the editor, studies with overlapping cohorts, and review articles. The risk of bias was evaluated using the Methodological Index for Non-Randomized Studies (MINORS) criteria.
RESULTS
The final analysis included 4 studies with 510 patients (457 male and 53 female patients), ranging in age between 17.8 and 27.5 years, treated with repair and suture augmentation for UCL tears. In this review, we found a mean postoperative KJOC score ranging from 87.9 to 92.6. The overall rate of return to play at the preinjury level or at a higher level than the preinjury level ranged from 67% to 93%; the mean time to return to play ranged from 6.7 to 17.6 months. The postoperative complication rate in this review ranged from 0% to 11.9%. Among the complications, the most common were ulnar nerve paresthesia (range, 0%-8.2%) and postoperative medial elbow pain (range, 0%-3.1%). Overall, the reoperation rate ranged from 0% to 3.4%. No reruptures were reported.
CONCLUSIONS
UCL repair with the use of suture augmentation results in postoperative KJOC scores ranging from 87.9 to 92.6, a return-to-play rate between 67% and 93%, and a postoperative complication rate up to 11.9%.
LEVEL OF EVIDENCE
Level IV, systematic review of Level IV studies.
PubMed: 37546384
DOI: 10.1016/j.asmr.2023.100761 -
Eplasty 2023The objective of this study was to investigate the surgical repair techniques and the outcomes of sciatic nerve injuries in traumatic wounds. (Review)
Review
BACKGROUND
The objective of this study was to investigate the surgical repair techniques and the outcomes of sciatic nerve injuries in traumatic wounds.
METHODS
A literature search was conducted using the following keywords: and
RESULTS
In total, 715 studies were retrieved. After abstract review, 13 articles fit the criteria. A total of 2627 repairs were carried out, including nerve grafts (n = 953), suture (n = 482), and neurolysis (n = 1192). Six studies reported good motor outcome, and good sensory outcome was reported across 2 studies. The thigh region accounted for 81.5% of lesions. Sciatic, peroneal, and tibial nerves were all equally affected. Gunshot wounds were the most common mechanism of injury (22.6%).
CONCLUSIONS
The cumulative evidence demonstrates sciatic nerve injury repair has poor motor and sensory outcomes. This study shows there is a lack of standardized outcome measures, making comparisons very difficult. Graft lengths of <4 cm within the intermediate region yielded more successful outcomes. Further higher quality studies of nerve transfers in the lower limbs are needed to determine the optimal repair to restore sciatic nerve function.
PubMed: 37664809
DOI: No ID Found