Circulation. Arrhythmia and... Aug 2023The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described.
BACKGROUND
The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described.
METHODS
In a retrospective study of adult patients with congenital heart disease who underwent catheter ablation for atrial fibrillation between 2000 and 2020 at Mayo Clinic, procedural characteristics and outcomes were collected. The primary outcomes were atrial arrhythmia (AA) recurrence following a 3-month blanking period and repeat ablation. An arrhythmia clinical severity score was assessed pre- and post-ablation based on the duration of arrhythmia episodes, symptoms, cardioversion frequency, and antiarrhythmic drug use.
RESULTS
One hundred forty-five patients (age, 57±12 years; 28% female; 63% paroxysmal atrial fibrillation) underwent 198 ablations with a median follow-up of 26 months (interquartile range, 14-69). One hundred ten, 26, and 9 patients had simple, moderate, and complex congenital heart disease, respectively. All patients underwent pulmonary vein isolation, and non-pulmonary vein targets were ablated in 79 (54%). AA recurrence at 12 months was 37% (95% CI, 29%-45%). On univariate analysis, increasing left atrial volume index was associated with higher odds of AA recurrence (odds ratio, 1.03 [1.00-1.06] per 1 mL/m increment; =0.05). Noninducibility of atrial flutter was predictive of decreased odds of AA recurrence (odds ratio, 0.43 [0.21-0.90]; =0.03). A second ablation was performed in 43 patients after a median of 20 (interquartile range, 8-37) months. Arrhythmia clinical severity scores improved following ablation, reflecting a decrease in symptoms, cardioversions, and antiarrhythmic drugs.
CONCLUSIONS
Catheter ablation of atrial fibrillation is feasible and effective in patients with adult congenital heart disease and reduces symptoms. Recurrence of AA frequently requires repeat ablation.
Topics: Humans; Adult; Female; Middle Aged; Aged; Male; Atrial Fibrillation; Retrospective Studies; Treatment Outcome; Heart Defects, Congenital; Anti-Arrhythmia Agents; Pulmonary Veins; Catheter Ablation; Recurrence
PubMed: 37485717
DOI: 10.1161/CIRCEP.122.011392 -
Clinical Cardiology Jul 2023Limited data on the efficacy and safety of atrial fibrillation (AF) ablation using an ablation index (AI) for octogenarians is available. We aimed to compare the...
BACKGROUND
Limited data on the efficacy and safety of atrial fibrillation (AF) ablation using an ablation index (AI) for octogenarians is available. We aimed to compare the efficacy and safety of AI-guided AF ablation between AF patients aged ≥80 years (Group 1) and <80 (Group 2).
HYPOTHESIS
We hypothesized that AI-guided AF ablation could complete the procedure with comparable efficiency and safety in patients aged ≥80 years and <80.
METHODS
We retrospectively reviewed 2087 AF patients undergoing their first AI-guided AF ablation in our hospital. We compared the atrial tachyarrhythmia (AT) recurrence and procedure-related complication rate between Group 1 (n = 193) and Group 2 (n = 1894).
RESULTS
The mean age was 83.0 (interquartile range [IQR] 81.0, 84.0) years in Group 1 and 67.0 (IQR 60.0, 72.0) in Group 2. AF type was significantly different between the two groups: Of Group 1 patients, 120 (62.2%) had paroxysmal AF, 61 (31.6%) persistent AF, and 12 (6.2%) long-standing persistent AF, while of Group 2 patients, 1016 (53.6%) paroxysmal AF, 582 (30.7%) persistent AF, and 296 (15.6%) long-standing persistent AF (p = .001). Unadjusted AT recurrence-free survival curves showed similar AT recurrence-free survival between the two groups (p = .67 by log-rank test). After the adjustment for AF type, the survival curve was similar between them (hazard ratio, 1.24; 95% CI [0.92-1.65]; p = .15, Group 1 vs. Group 2). The rate of procedure-related complications was similar between the two groups (3.1% vs. 3.0%, respectively, p = .83).
CONCLUSION
Catheter ablation guided by AI achieved similar AT recurrence and complication rates between elderly AF patients aged ≥80 years and patients <80 years.
Topics: Aged; Aged, 80 and over; Humans; Atrial Fibrillation; Retrospective Studies; Octogenarians; Treatment Outcome; Heart Atria; Catheter Ablation; Pulmonary Veins
PubMed: 37199002
DOI: 10.1002/clc.24031 -
Journal of the American Heart... Jul 2023Background Despite the high burden of atrial fibrillation in cardiac amyloidosis (CA), the safety of catheter ablation therapy in CA is not well established. We sought...
Background Despite the high burden of atrial fibrillation in cardiac amyloidosis (CA), the safety of catheter ablation therapy in CA is not well established. We sought to examine short-term safety outcomes following atrial fibrillation ablation in patients with CA compared with matched patients with dilated cardiomyopathy (DCM). Methods and Results Using data from the National Inpatient Sample, we identified all hospitalizations for atrial fibrillation ablation from the fourth quarter of 2015 through 2019. Admissions for CA and DCM were matched in a 1:5 ratio using propensity scores based on the following sociodemographics: age, sex, race or ethnicity, payor, median income, comorbidities, and hospital characteristics. We compared in-hospital outcomes between both cardiomyopathies. We identified 1395 unweighted hospitalizations (representing 6750 national hospitalizations) for atrial fibrillation ablation, out of which 45 (3.2%) were admissions for CA. Compared with DCM, patients with CA were older (72.9 versus 65.1 years), had a higher burden of prior stroke (20.0% versus 8.6%) and chronic kidney disease (53.3% versus 33.6%), and were less likely to have a prior implantable cardioverter-defibrillator (4.4% versus 23.0%). We successfully matched 42 CAs to 210 DCM hospitalizations. After matching, there was no difference in total complications (14.3% versus 10.5%, =0.60), length-of-stay (3.1 versus 2.1 days, =0.23), home disposition (97.6% versus 96.2%, =0.65), and total charges ($137 250 versus $133 910, =0.24). Conclusions In this nationally representative study of atrial fibrillation catheter ablation in CA, short-term safety outcomes and complication rates were similar to a propensity score-matched cohort of DCM. Further studies exploring long-term safety outcomes are needed.
Topics: Humans; Atrial Fibrillation; Treatment Outcome; Cardiomyopathies; Cardiomyopathy, Dilated; Catheter Ablation; Amyloidosis
PubMed: 37449569
DOI: 10.1161/JAHA.122.029339 -
Journal of the American Heart... Sep 2023
Topics: Humans; Atrial Fibrillation; Pulmonary Veins
PubMed: 37642025
DOI: 10.1161/JAHA.123.031258 -
Journal of Clinical Medicine Sep 2023Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients...
BACKGROUND
Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources.
OBJECTIVE
This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF.
METHODS
Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs.
RESULTS
In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62-95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort.
CONCLUSION
LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.
PubMed: 37834948
DOI: 10.3390/jcm12196304 -
Europace : European Pacing,... Aug 2023The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how...
The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power. Also, so-called single-shot devices were developed with balloons and arrays to create larger contiguous lesions, and energy sources changed from RF current to cryogenic ablation and more recently pulsed field ablation with electrical current. Although PV ablation has remained the basis for every AF ablation, it was soon recognized that this was not enough to cure all patients, especially those with non-paroxysmal AF. Standardized approaches for additional ablation targets have been used but have not been satisfactory in all patients so far. This led to highly technical mapping systems that are meant to unravel the drivers for the maintenance of AF. In the following sections, the development of energies, strategies, and tools is described with a focus on the contribution of Europace to publish the outcomes of studies that were done during the past 25 years.
Topics: Humans; Atrial Fibrillation; Catheter Ablation; Catheters; Irreversible Electroporation Therapy
PubMed: 37622592
DOI: 10.1093/europace/euad244 -
Journal of the American Heart... Jan 2024The increasing prevalence of atrial fibrillation (AF) in adults with congenital heart disease raises significant questions regarding its management. The unique... (Review)
Review
The increasing prevalence of atrial fibrillation (AF) in adults with congenital heart disease raises significant questions regarding its management. The unique underlying anatomic and physiological background further adds to the difficulty in eliminating the AF burden in these patients. Herein, we provide an overview of the current knowledge on the pathophysiology and risk factors for AF in adult congenital heart disease, with a special focus on the existing challenges in AF ablation. Emerging imaging modalities and ablation techniques might have a role to play. Evidence regarding the safety and efficacy of AF ablation in adult congenital heart disease is summarized, especially for patients with an atrial septal defect, Ebstein anomaly of the tricuspid valve, tetralogy of Fallot, and Fontan circulation. Finally, any remaining gaps in knowledge and potential areas of future research are highlighted.
Topics: Humans; Adult; Heart Defects, Congenital; Atrial Fibrillation; Heart Septal Defects, Atrial; Catheter Ablation; Ebstein Anomaly
PubMed: 38193287
DOI: 10.1161/JAHA.123.032102 -
Europace : European Pacing,... Dec 2023Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary...
AIMS
Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients.
METHODS AND RESULTS
Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01).
CONCLUSION
Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.
Topics: Female; Humans; Middle Aged; Aged; Male; Atrial Fibrillation; Cryosurgery; Propensity Score; Treatment Outcome; Heart Atria; Pulmonary Veins; Catheter Ablation; Recurrence
PubMed: 38245007
DOI: 10.1093/europace/euae016 -
Heart (British Cardiac Society) Jan 2024Catheter ablation of atrial fibrillation effectively reduces symptomatic burden. However, its long-term effect on mortality and stroke is unclear. We investigated if...
OBJECTIVE
Catheter ablation of atrial fibrillation effectively reduces symptomatic burden. However, its long-term effect on mortality and stroke is unclear. We investigated if patients with atrial fibrillation who undergo catheter ablation have lower risk for all-cause mortality or stroke than patients who are managed medically.
METHODS
We retrospectively included 5628 consecutive patients who underwent first-time catheter ablation for atrial fibrillation between 2008 and 2018 at three major Swedish electrophysiology units. Control individuals with an atrial fibrillation diagnosis but without previous stroke were selected from the Swedish National Patient Register, resulting in a control group of 48 676 patients. Propensity score matching was performed to produce two cohorts of equal size (n=3955) with similar baseline characteristics. The primary endpoint was a composite of all-cause mortality or stroke.
RESULTS
Patients who underwent catheter ablation were healthier (mean CHADS-VASc score 1.4±1.4 vs 1.6±1.5, p<0.001), had a higher median income (288 vs 212 1000 Swedish krona [KSEK]/year, p<0.001) and had more frequently received university education (45.1% vs 28.9%, p<0.001). Mean follow-up was 4.5±2.8 years. After propensity score matching, catheter ablation was associated with lower risk for the combined primary endpoint (HR 0.58, 95% CI 0.48 to 0.69). The result was mainly driven by a decrease in all-cause mortality (HR 0.51, 95% CI 0.41 to 0.63), with stroke reduction showing a trend in favour of catheter ablation (HR 0.75, 95% CI 0.53 to 1.07).
CONCLUSIONS
Catheter ablation of atrial fibrillation was associated with a reduction in the primary endpoint of all-cause mortality or stroke. This result was driven by a marked reduction in all-cause mortality.
Topics: Humans; Atrial Fibrillation; Risk Factors; Risk Assessment; Retrospective Studies; Stroke; Catheter Ablation; Treatment Outcome
PubMed: 37657914
DOI: 10.1136/heartjnl-2023-322883 -
Europace : European Pacing,... Aug 2023Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM.
METHODS AND RESULTS
We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13-54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305-1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713-4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070-2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235-2.090; P < 0.001).
CONCLUSIONS
Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.
Topics: Humans; Atrial Fibrillation; Cardiomyopathy, Hypertrophic; Ablation Techniques; Cardiovascular Agents; Catheter Ablation
PubMed: 37595138
DOI: 10.1093/europace/euad256