-
Cureus Jan 2024The virtual articulator (VA) is a technology that simulates the jaw relation in a computer-generated setting. Augmented and virtual reality have been utilized as digital... (Review)
Review
The virtual articulator (VA) is a technology that simulates the jaw relation in a computer-generated setting. Augmented and virtual reality have been utilized as digital technology, which aids in many areas of dentistry and dental education. Today, a practicing dentist must keep up with the newer technologies, but with technology evolving so quickly it becomes challenging. In dentistry, the possibilities for digitization and technological advancements are limitless. Virtual articulators (VAs) allow a complete occlusion analysis using dental models that replicate all mandibular motions in static and dynamic scenarios. VA when executed in addition to other software enhances treatment planning and patient education, allowing quicker and more precise individualized diagnoses. The main objective of this study was to describe and evaluate the study outcomes in the available research on VAs, assess their needs, and evaluate their advantages and limitations in various aspects. A PubMed Central search was made of dental journals, with the identification of 135 articles out of which 30 were finally selected. The investigations conducted to evaluate the VA's dependability provide good visualization of the quantity and location of the dynamic interactions. A precise instrument for fully analyzing occlusion in a real patient is the virtual articulator.
PubMed: 38371021
DOI: 10.7759/cureus.52554 -
Bioengineering (Basel, Switzerland) Oct 2023Dental articulation holds crucial and fundamental importance in the design of dental restorations and analysis of prosthetic or orthodontic occlusions. However, common...
Dental articulation holds crucial and fundamental importance in the design of dental restorations and analysis of prosthetic or orthodontic occlusions. However, common traditional and digital articulators are difficult and cumbersome in use to effectively translate the dental cast model to the articulator workspace when using traditional facebows. In this study, we have developed a personalized virtual dental articulator that directly utilizes computed tomography (CT) data to mathematically model the complex jaw movement, providing a more efficient and accurate way of analyzing and designing dental restorations. By utilizing CT data, Frankfurt's horizontal plane was established for the mathematical modeling of virtual articulation, eliminating tedious facebow transfers. After capturing the patients' CT images and tracking their jaw movements prior to dental treatment, the jaw-tracking information was incorporated into the articulation mathematical model. The validation and analysis of the personalized articulation approach were conducted by comparing the jaw movement between simulation data (virtual articulator) and real measurement data. As a result, the proposed virtual articulator achieves two important functions. Firstly, it replaces the traditional facebow transfer process by transferring the digital dental model to the virtual articulator through the anatomical relationship derived from the cranial CT data. Secondly, the jaw movement trajectory provided by optical tracking was incorporated into the mathematical articulation model to create a personalized virtual articulation with a small Fréchet distance of 1.7 mm. This virtual articulator provides a valuable tool that enables dentists to obtain diagnostic information about the temporomandibular joint (TMJ) and configure personalized settings of occlusal analysis for patients.
PubMed: 38002372
DOI: 10.3390/bioengineering10111248 -
Medicina (Kaunas, Lithuania) Jul 2023Learning to speak properly requires a fully formed brain, good eyesight, and a functioning auditory system. Defective phonation is the outcome of a failure in the... (Review)
Review
Learning to speak properly requires a fully formed brain, good eyesight, and a functioning auditory system. Defective phonation is the outcome of a failure in the development of any of the systems or components involved in speech production. Dentures with strong phonetic skills can be fabricated with the help of a dentist who has a firm grasp of speech production and phonetic characteristics. Every dentist strives to perfect their craft by perfecting the balance between the technical, cosmetic, and acoustic aspects of dentistry, or "phonetics". The ideal prosthesis for a patient is one that not only sounds good but also functions well mechanically and aesthetically. Words are spoken by using articulators that alter their size and form. : Therefore, a prosthesis should be made in such a way that it does not interfere with the ability to communicate. As a result, a prosthodontist has to have a solid grasp of how speech is made and the numerous parts that go into it.
Topics: Humans; Speech; Phonetics; Phonation; Learning; Brain
PubMed: 37512133
DOI: 10.3390/medicina59071322 -
Life (Basel, Switzerland) Jun 2023The condylar guidance value (CGV) measurement constitutes an important part of a holistic prosthodontic treatment plan, with horizontal CGVs (HCGVs) and lateral CGVs... (Review)
Review
The condylar guidance value (CGV) measurement constitutes an important part of a holistic prosthodontic treatment plan, with horizontal CGVs (HCGVs) and lateral CGVs (LCGVs) being two of the most prominently recognized. This systematic review aimed at evaluating the efficacy of two different types of CGV measurement protocols-articulators (both arcon and non-arcon) and panoramic radiographs. Additionally, it attempts to determine which of the mentioned methods performs better across several parameters. Several important web databases were searched using search terms derived from medical subject headings (MeSH), using keywords linked to "Arcon articulator", "Condylar guidance angle", "non-arcon articulator", "Panoramic x-ray" and "Radiographic examination", which constituted the first step in the study selection strategy. After completion, the search strategy which initially turned up to 831 papers, eventually ended up with 13 studies. The review and subsequent meta-analysis revealed that panoramic radiographs had noticeably greater efficacy in terms of the CGVs as compared to the articulators in the majority of the studies. Within the articulators, the arcon types recorded slightly higher CGVs than the non-arcon variety owing to the precision of jaw movement simulation in the former. However, further studies are required to validate these findings and establish more precise guidelines for the use of CGV measurement protocols in prosthodontic practice.
PubMed: 37374135
DOI: 10.3390/life13061352 -
Scientific Data Dec 2023The use of real-time magnetic resonance imaging (rt-MRI) of speech is increasing in clinical practice and speech science research. Analysis of such images often...
The use of real-time magnetic resonance imaging (rt-MRI) of speech is increasing in clinical practice and speech science research. Analysis of such images often requires segmentation of articulators and the vocal tract, and the community is turning to deep-learning-based methods to perform this segmentation. While there are publicly available rt-MRI datasets of speech, these do not include ground-truth (GT) segmentations, a key requirement for the development of deep-learning-based segmentation methods. To begin to address this barrier, this work presents rt-MRI speech datasets of five healthy adult volunteers with corresponding GT segmentations and velopharyngeal closure patterns. The images were acquired using standard clinical MRI scanners, coils and sequences to facilitate acquisition of similar images in other centres. The datasets include manually created GT segmentations of six anatomical features including the tongue, soft palate and vocal tract. In addition, this work makes code and instructions to implement a current state-of-the-art deep-learning-based method to segment rt-MRI speech datasets publicly available, thus providing the community and others with a starting point for developing such methods.
Topics: Adult; Humans; Dental Articulators; Image Processing, Computer-Assisted; Magnetic Resonance Imaging; Speech
PubMed: 38042857
DOI: 10.1038/s41597-023-02766-z -
The Journal of Prosthetic Dentistry Sep 2023Although different digital occlusal analyzers have been marketed, comparative studies are lacking.
STATEMENT OF PROBLEM
Although different digital occlusal analyzers have been marketed, comparative studies are lacking.
PURPOSE
The purpose of this in vitro study was to compare the repeatability and reproducibility of 2 different digital occlusal analyzers (T-Scan and OccluSense) for measuring the right- and left-side balance of occlusal contact forces.
MATERIAL AND METHODS
The repeatability and reproducibility of the 2 digital occlusal analyzers for measuring the balance of occlusal contact forces were determined and compared by using the Gauge Repeatability and Reproducibility tests based on the International Organization for Standardization (ISO), ISO 5725-2 and ISO 5725-3 standards. Ten different dental casts were mounted in the maximum intercuspation position on a semi-adjustable articulator. Then, the balance of occlusal contact forces in each of the 10 articulated dental casts was measured 24 times with each of the 2 digital occlusal analyzers. In addition, as the OccluSense, unlike the T-Scan, does not have a centering support for the piezoelectric film sensor, measurements with it were performed without and with a custom-designed and manufactured centering support. Finally, the repeatability and reproducibility of both digital occlusal analyzers were determined and compared using the Gauge Repeatability and Reproducibility tests.
RESULTS
The repeatability and reproducibility tests revealed that only 0.8% of the variance of the measurements obtained with the T-Scan was due to repeatability and reproducibility (0.4% repeatability, 0.4% reproducibility). In contrast, 12% of the variance of the measurements obtained with the OccluSense was due to repeatability and reproducibility (2.2% repeatability, 9.8% reproducibility). However, when using OccluSense with the centering support, the variance decreased to 6.4% (2.8% repeatability, 3.6% reproducibility). According to the Automotive Industry Action Group classification, the repeatability and reproducibility of the T-Scan were good, those of the OccluSense poor, and those of the OccluSense with the centering support medium.
CONCLUSIONS
The repeatability and reproducibility of the T-Scan were significantly better than those of the OccluSense for measuring the balance of occlusal contact forces. Furthermore, the repeatability and reproducibility of the OccluSense were significantly improved when used with a device to center the piezoelectric film sensor between the incisors. Nevertheless, the repeatability and reproducibility of the T-Scan were better.
PubMed: 37661548
DOI: 10.1016/j.prosdent.2023.07.026 -
Annals of African Medicine 2023During complete denture fabrication making Interocclusal records plays an integral role to obtain the condylar guidance value. The study was conducted to compare the...
BACKGROUND AND PURPOSE
During complete denture fabrication making Interocclusal records plays an integral role to obtain the condylar guidance value. The study was conducted to compare the protrusive condylar guidance registration by two interocclusal recording materials-Quick setting plaster and Luxabite®(bisacrylic composite) in semi adjustable articulator for completely edentulous patients.
METHODOLOGY
Maxillary and Mandibular casts of the completely edentulous patients were mounted in Hanau®Wide Vue articulator. The Quick setting plaster and Luxabite®(bisacrylic composite) was used as interocclusal recording materials to program the protrusive condylar guidance angles in the articulators.
RESULTS
The protrusive condylar guidance values registered in the articulator for the different interocclusal records were tabulated and statistically analyzed.. The mean protrusive condylar guidance values registered in the articulator was compared with two parameters obtained from the radiographic tracings -- the protrusive condylar path angle obtained with Quick setting plaster and Luxabite with the inclination of articular eminence to the Frankfort horizontal plane.
CONCLUSION
From the study it was concluded that the Luxabite®(bisacrylic composite) material demonstrated better reproducibility of protrusive condylar guidance registration.than the Quick setting plaster.
Topics: Humans; Mandibular Condyle; Jaw Relation Record; Reproducibility of Results; Mandible; Resin Cements
PubMed: 37417019
DOI: 10.4103/aam.aam_70_22 -
Dental Research Journal 2023Horizontal condylar guidance (HCG) is registered by protrusive interocclusal records but in nonarcon articulators, these records can affect the accuracy. The present...
BACKGROUND
Horizontal condylar guidance (HCG) is registered by protrusive interocclusal records but in nonarcon articulators, these records can affect the accuracy. The present study aimed to evaluate the effect of a novel rotation coordinating device (RCD) on condylar guidance setting with protrusive interocclusal records.
MATERIALS AND METHODS
The study was designed as a comparative investigation. Stone maxillary and mandibular casts were mounted on a fully adjustable instrument as the patient. Duplicate casts were mounted on an arcon and a nonarcon articulator with corresponding face bow records and in maximum intercuspation relation. Five different condylar guidance inclinations for both sides (20°, 30°, 40°, 50°, and 60°) were set on the fully adjustable instrument and 16 protrusive interocclusal records were established at each setting. HCG was set for arcon, nonarcon articulators, and nonarcon articulators with RCD. Data were analyzed using one-sample -test to compare with actual HCG and one-way analysis of variance ( =0.05).
RESULTS
Mean HCG for studied articulators was 35.40 for arcon, 30.31 for nonarcon without RCD, and 35.61 for nonarcon with RCD which were significantly different from actual HCG ( < 0.05). HCG of the nonarcon with RCD showed no significant difference with arcon articulator ( = 0.71) while both were significantly different from nonarcon without RCD ( < 0.001).
CONCLUSION
"The RCD" compensates the condylar guidance inclination difference between arcon and nonarcon articulators. The device precisely transfers the hinge movement of the upper member of the articulator to the condylar track.
PubMed: 38020259
DOI: No ID Found -
Hua Xi Kou Qiang Yi Xue Za Zhi = Huaxi... Feb 2024This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether...
OBJECTIVES
This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether differences existed between the left and right SCI values of the same participant, to provide a reference for clinical practice.
METHODS
Ten participants with good occlusal relationship and normal temporomandibular joint were recruited. Three methods were used to measure the SCI values of the participants, namely, A (mechanical facebow transferring and mechanical articulator-based measuring method with physical protrusive interocclusal registration), B (face scan-based virtual facebow and virtual articulator-based measuring method with digital protrusive interocclusal registration), and C (jaw motion tracking system-based measuring method). With the group subjected to methods A and C as the control, the SCI values obtained by the three methods were statistically analyzed. The left and right SCI values of the same participant were also compared.
RESULTS
The left and right SCI values measured by method A were 41.70°±7.09° and 42.80°±8.62°, those by method B were 35.09°±12.49° and 37.63°±12.10°, and those by method C were 39.43°±8.72° and 38.45°±6.91°. No significant difference existed among the SCI values measured by the three methods (>0.05). Meanwhile, no statistical difference existed between the SCI values on the left and right sides of the same participant (>0.05).
CONCLUSIONS
The accuracy of the virtual facebow and digital protrusive occlusal registration based SCI measuring method was the same as that of mechanical facebow based and jaw motion tracking system-based methods. The SCI values on the left and right sides of the same participant were similar. Clinically, an appropriate SCI measurement and setting strategy can be selected based on the actual situations.
Topics: Humans; Mandibular Condyle; Jaw Relation Record; Temporomandibular Joint; Dental Articulators; Extraoral Traction Appliances
PubMed: 38475953
DOI: 10.7518/hxkq.2024.2023242 -
The Journal of Prosthetic Dentistry Jul 2023This technique report describes a fully digital workflow to create a prosthetic articulator-based implant rehabilitation (PAIR) virtual patient for complete-arch or...
This technique report describes a fully digital workflow to create a prosthetic articulator-based implant rehabilitation (PAIR) virtual patient for complete-arch or complete-mouth implant rehabilitation. This workflow uses a custom gothic arch tracer during the cone beam computed tomography (CBCT) scan and a 3-dimensional virtual facebow when superimposing data. The PAIR virtual patient possesses reliable centric relation and vertical dimension of occlusion and is compatible with virtual articulators. Computer-aided implant planning and a digital prosthetic design can be seamlessly integrated by using this virtual patient.
Topics: Humans; Dental Implants; Dental Articulators; Computer-Aided Design; Image Processing, Computer-Assisted; Cone-Beam Computed Tomography; Imaging, Three-Dimensional
PubMed: 34756772
DOI: 10.1016/j.prosdent.2021.09.013